Home

LABTOOL-T400 - Advantech Equipment Corp.

image

Contents

1. File Note Figure 4 4 Programming progress screen Verifying a device Menu Device Verify Hot key Alt V This function compares the contents of the active device with the contents of the memory buffer It will display an error message and the address if it finds an address where the data differs It will also abort the process when this happens 26 4E0403000003 LabTool T400 Turbo Flash Gang Program ner File Project Device Options Diagnosties View Help o alal soli lala al eam sl 101 Save Load 5 Verifying Verifying a n 00 01 07 29 Module 0 Module 2 Program com ID Checking Current Qty Erasing Blank Check Programming Verifying a Target Qty 00 01 12 28 1000 Program com ID Checking gt gt verifying a Module 1 3 Total Fail zi 1596 1596 o gt Device Max Fail Adapter Size Check Sum 3 File unt Note re z0 WM y Figure 4 5 Device verification screen Memory Protect Menu Device Memory Protect Hot key CTRL P This function is a device specific command it appears on the main menu only after chips having this capability are selected The function must be configured before use When properly configured it can be selected and will automatically set memory protection on the chips immedi
2. Updating the LABTOOL T400 Software We provide quarterly formal releases of the LABTOOL T400 software on our website Monthly temporary releases are also available on our website Please download releases from our website at www aec com tw 16 Command Hierarchy 17 LABTOOL T400 Command Hierarchy File ALT F Project ALT J Device ALT D Options ALT O Diagnostics ALT I Save Buffer Load File Exit Save Project Load Project Change Mass Produce Edit Read Blank Check Program Verify Memory Prot Prog Config Erase Configuration Operation Module Options Search Machine Statistic Self Test ALT S ALT L ALT X ALT FI ALT P2 ALT C ALT M ALT E ALT R ALT B ALT P ALT V Ctrl P Ctrl E Ctrl G F4 F5 F6 F7 F8 18 19 LED Display on Each Socket Each of 4 adapter modules in the LABTOOL T400 has a tri color LED display to indicate the status of the socket Read this section carefully to avoid damage to chips Warning Do not insert or remove a chip from a socket while the socket LED is yellow LED color key Blank the adapter module is not active Green the adapter module is active or the last operation result passed Yellow the adapter module is busy don t do anything until the LED turns Green or Red Red the last operation resulted in failure the socket is active and awaiting another operation Flashi
3. System A estore Il _ Automatic Updates E Remote General IL Computer Name Hardware Advanced Device Manager gt The Device Manager lists all the hardware devices installed on pour computer Use the Device Manager to change the properties of any device Device Manager Drivers Driver Signing lets you make sure that installed drivers are compatible with Windows windows Update lets you set up how Windows connects to Windows Update for drivers Driver Signing Windows Update Hardware Profiles Hardware profiles provide a way for you to set up and store 2 2281 different hardware configurations Hardware Profiles Fig3 2 The USB Device may be below Universal Serial Bus controllers or Other devices Device Manager File Action View Help mma gt Mice and other pointing devices Monitors BB Network adapters Other devices _Y Ports COM amp LPT 888 Processors Sound video and game controllers m System devices E 2 Universal Serial Bus controllers Intel R 82801 USB Universal Host Controller 2442 Intel R 82801BA BAM USB Universal Host Controller 2444 NEC PCI to USB Enhanced Host Controller B1 NEC PCI to LISB Open Host Controller NEC PCI to LISB Open Host Controller USB Device LISB Root Hub LISB Root Hub LISB Root Hub LISB Root Hub LISB Root Hub 54 Step4 Uninstall the USB Device Fig4 1 Press the
4. 3 Windows Messenger All Programs a Windows Movie Maker BB og or turn computer 848UXP fir LT T400 correct 202 Paint Fig8 2 After run the LabTool T400 software you will see your LabTool T40 serial number with USB interface amp AE0404000002 LabTool T400 Turbo Flash Gang Programmer File Project Device Options Diagnostics View Help gt gt Found LabTool T400 AEO0404000002 Device None Type None Adapter None Pin None n Size None VCC None Manufacture Code None Check Sum None Device Code None 1 3 File Current Count 0 25 4 la asa
5. and then press Next Found New Hardware Wizard This wizard helps you install software for AEC LabTool T400 Turbo Flash Gang Programmer If your hardware came with an installation CD Sp or floppy disk insert it now What do you want the wizard to do O Install from a list or specific location Advanced Click Next to continue 45 Fig2 3 Installing Found New Hardware Wizard Please wait while the wizard searches AEC LabTool T400 Turbo Flash Gang Programmer Cancel Fig2 4 Press Continue Anyway If you select the other button the O S will has a wrong USB Device in your PC Hardware Installation The software you are installing for this hardware AEC LabTool T400 Turbo Flash Gang Programmer has not passed Windows Logo testing to verify its compatibility with Windows XP Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyway STOP Installation 46 Fig2 5 Press Finish Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for 2 AEC LabT ool T 400 Turbo Flash Gang Programmer Click Fini
6. Address A selected address is to be read from the buffer fill in the address that will contain the first byte into this box Buffer Size The size of the buffer to be read Load File Menu File Load File Hot key Alt L This option loads a file from disk into the memory buffer The type of files that can be loaded for a device depends on the device type Select a file to load using the mouse or type the filename in the box provided You can also type in a file spec e g hex at the Name prompt This will display all the files of the specified type and you can then select the required file to load Auto Format Detected The software automatically detects the format of the file that is to be loaded If the desired format of the file differs from the format detected select the correct file format From File This option indicates which bytes must be read in the input file Select the required format To Buffer This option indicates where the byte previously read is to be written This enables you to build the memory buffer from several files From File Address If only a selected range is to be read from the input file fill in the address that will contain the first byte into this box and the size of the buffer to be read in Size To Buffer Address If the data read is to be copied into a specific area of the buffer fill in the starting address here Buffer Size This box contains the buffer size By default it is the sam
7. Options Diagnostics View Help Ea THREE Save Load Select Auto Edit Vector Read Blank Prog Verify Erase Prot Config Option gt gt Macronix MX29LV640B 48TS Module Options Master Active Module 0 Module 0 Module 1 Module 1 Module 2 Module 2 Module 3 Module 3 Device Macronix MX2 Adapter TM UNIV 48TS wem 2 Size 400080hX16 V Check Sum 7F80FF00h VPP 12 00 Device Code 22CBh 1 3 File Current Count 0 Note Flash 0 7fffff SecSi 800000 800064 Current Failure 0 Ready NUM 2 Figure 4 9 Master Module selection Active Module selection Search Machine Menu Options Search Machine Hot key F6 This option is used to search LABTOOL T400 in which USB port and software When you turn the LABTOOL T400 off and then on you have to use this option to search an unassigned LABTOOL T400 for controlled by present software 31 4E0403000003 LabTool T400 Turbo Flash Gang Programmer Bl x File Project Device Options Diagnostics View Help ea Er zs 85 en sel Save Load Select 211010 Edit Read Blank Prog Verify Erase Prot Config Option gt gt Found LabTool T400 0403000003 Device Macronix MX29LY640B 48TS Adapter TM UNIV 48TS Size 400080hX16 VCC 3 30Y Manufacture Code Check Sum 7F80FF00h VPP 12 00V Device Code 3
8. are programmed The insertion timer default time is 5 seconds 24 Editing the Buffer Menu Device Edit Hot key Alt E This function is used to edit the memory buffer The memory buffer contains the last file downloaded from disk into memory If no file has been downloaded from disk into memory since the LABTOOL T400 was switched on the memory buffer will contain garbage The screen that is displayed is dependent on the type of device that is currently active The purposes of the buttons displayed are as follows Radix This button controls the display of the memory address in Hex decimal format If the address is currently displayed in decimal format clicking this button will convert and display the address in Hex Fill This option is used to fill a block of memory with a specified value It needs the starting address the ending address and the value to be copied into this block of memory Copy This function copies a block in memory to a new address It requires the starting address the ending address and the address the block must be copied to Search This function searches for a specified search string It requires input of the search string to search for Undo As you make changes to the memory buffer the changes on the current page are highlighted If you choose this option it will reverse all changes made to the highlighted areas As soon as the changed memory positions move off the screen or get deselected b
9. be programmed and an allowable number of programming failures An alarm message option provides a message to the screen alerting the user to either the target quantity of chips being reached or the allowable number of failures being reached For a detailed explanation of the device operation options please refer to Chapters 3 and 4 General Information Introduction LABTOOL T400 Turbo Flash Gang Programmer is four sockets PC based gang programmer that works through PC s USB port USB1 1 USB2 0 It features four fully independent isolated modules extremely high speed in writing flash memory chip It supports 3 3V 2 7V 2 5V 2V 1 8V 1 5V and 1 2V chip in both VCC and I O without low voltage converter and handles the data bus 8 16 32 bits NOR and NAND flash chip in different package through adapter modules up to 128Gb flash chip can be support The LABTOOL T400 is an ideal programmer for customers in DV DVD MP3 GSM Panel 3G Mobile PDA Smart Phone Internet router and others Features Unbeatable speed through programming speed and throughput The LABTOOL T400 has built in Compact Flash Card CF on board that reduces the massive data transfer between the PC and LABTOOL T400 The LABTOOL T400 performance reaches the speed limitation of the chips in its specification No other gang programmer today and feature can beat the speed of the LABTOOL T400 LABTOOL T400 Performance PC with P4 1 3G 1024M RAM Following
10. chips being reached or the allowable number of failures being reached 11 LABTOOL T400 Profile Are LAB IOUL T400 E TURBO FLASH GANG PROGRAMMER TM 13340 80F TM 13340 80F _ l 1 H NhI mt Tm T_ O NANNA o TM 13340 80F TM 13340 80F amp amp x FO DC INPUT USB OFFION d SVITA de 5 12V 3A x Device support summary The latest software the software download and update from www aec com tw Flash memory NOR NAND EEPROM and other flash technology Device data width 8 16 and 32 bits Maximum flash density support flash 1G bit with 256M byte CF Card installed on board standard offer can be extend to 128G bit with exchange higher density CF Card on the system Please reference from AEC s website www aec com tw download LabTool T400_ALL pdf Specification Socket and pin driver 4 fully isolated adapter module with receptacle over 10 M ohm resistance between each adapter module Four DACs for Veco and Vpp gt with 8 bit resolution and Vcc range 0 V to 6 0 V resolution 25 mV maximum current 250 mA Vpp and Vpp range 2 5 V to 18 V resolution 80 mV maximum current Overcurrent protection on all voltage sources resolution 2mA and maximum 500mA per source Logic level 3 3 V to 1 2 V programmable by software Device Operation Read blank check insertion contact check verify check sum erase chip program memory protect edit buffer configuratio
11. right button of the mouse and select Uninstall E Device Manager File Action View Help e gt A Rg Keyboards 77 Mice and other pointing devices 3 Monitors B9 Network adapters Other devices Ports COM amp LPT FR Processors Sound video and game controllers System devices Universal Serial Bus controllers Intel R 82801BA BAM USB Universal Host Controller 2442 Intel R 82801BA BAM USB Universal Host Controller 2444 NEC PCI to USB Enhanced Host Controller 1 NEC PCI to USB Open Host Controller NEC PCI to USB Open Host Controller USB Device B LSBRoot Update Driver USB Root _ Disable USB Root H USB Root H 1 gt coto fotoo 31 18 Scan for hardware changes Uninstalls the driver for the PrODerHes Fig4 2 Press Confirm Device Removal gt USB Device Warning You are about to uninstall this device from your system Cancel 55 File Action View Help 2 4 8 E Mice and other pointing devices 3 Monitors 880 Network adapters Other devices 27 Ports COM amp LPT Processors Sound video and game controllers System devices Universal Serial Bus controllers Intel R 82801BA BAM USB Universal Host Controller 2442 Intel R 82801BA BAM USB Universal Host Controller 2444 NEC PCI to LISB Enhanced Host Controller B1 NEC PCI to USB Open Host Controller NEC PCI
12. to USB Open Host Controller USB Root Hub USB Root Hub USB Root Hub USB Root Hub USB Root Hub 56 Step5 Turn the LABTOOL T400 power off Step6 Turn the LABTOOL T400 power on and then the OS found out a new USB device from your USB interface Fig6 1 Select No not this time and press Next Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation or on the Windows Update Web site with your permission Read privacy policy Can Windows connect to Windows Update to search for software O Yes this time only O Yes now and every time connect a device Gi Click Next to continue Fig6 2 Select Install the software automatically Recommended and then press Next Found New Hardware Wizard This wizard helps you install software for SEC LabTool T400 Turbo Flash Gang Programmer If your hardware came with an installation CD 22 or floppy disk insert it now What do you want the wizard to do Click Next to continue 57 Fig6 3 Installing Found New Hardware Wizard Please wait while the wizard searches e AEC LabT ool T400 Turbo Flash Gang Programmer Cancel Fig6 4 Press Continue Anyway If you select the other button the O S will has a wrong USB Device in your PC Hardware Installation The software yo
13. Blank Check Program Verify Memory Prot Prog Conti Device Information Device Macronix MX29LY640B 48TS Adapter TM UNIV 48TS Pin 48 O 2 Size 400080hX16 3 30V Manufacture Code Check Sum 7F80FF00h VPP 12 00V Device Code 22CBh 1 3 Current Count Current Failure 0 Change current device Information Line Statistics 14 Installation 15 Minimum PC System Requirements O S Win 98 ME Win 2000 SP4 and Win XP SP1 SP2 CPU PII 750 and above RAM 64 MB minimum 512 MB recommended HD 16 MB of free hard disk space Interface USB 1 1 2 0 USB2 0 recommended Installing the LABTOOL T400 Software Insert the CD into the PC s CD ROM E Drive It will execute the autorun to install LT T400 software In the file manager you can select the E LTT400 EXE and hit Enter it will create a directory called WLTT400 on your computer s C Programm Files AEC path and will install the LABTOOL T400 software in this directory Following successful installation and then installing LABTOOL T400 Installing the LABTOOL T400 1 Switch the LABTOOL T400 off 2 Install the LABTOOL T400 software 3 Connect the power adapter to the LABTOOL T400 4 Connect the LABTOOL T400 to a USB port using the USB cable supplied 5 Switch the LABTOOL T400 on 6 The O S automatically search USB device and customer press Continue during installing
14. EQUIPMENT A ADVANTECH LABTOOL T400 Turbo Flash Gang Programmer User s Manual Copyright Notice This document is copyrighted 1998 2006 by Advantech Equipment Corp Ltd All rights are reserved Advantech Equipment Corp Ltd reserves the right to make improvements to the products described in this manual at any time without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of Advantech Equipment Corp Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Equipment Corp Ltd assumes no responsibility for its use nor for any infringements upon the rights of third parties which may result from its use Acknowledgments IBM PC AT and VGA are trademarks of International Business Machines Corporation MS Windows are trademarks of Microsoft Corporation How to use this manual Thank you for purchasing LABTOOL T400 Turbo Gang Programmer We designed this manual to help you quickly and easily set up and use your LABTOOL T400 You can use the manual in two ways Step by step The manual should be used in conjunction with the On line help contained in the LABTOOL T400 software Once you ve installed the LABTOOL T400 and the software you shouldn t need this manual again You can just press F1 in the program and context sensitive help will guide you through the processes Quic
15. Enhanced Host Controller B1 NEC PCI to USB Open Host Controller PCI to USB Open Host Controller USB Root Hub USB Root Hub USB Root Hub USB Root Hub USB Root Hub FA 48 Step4 Run the LABTOOL T400 software Fig4 1 Select Start gt All Programs gt Advantech LabTool gt LabTool Internet My Documents E Internet Explorer e 2 5 Set Program Access and Defaults 5 E mail Outlook Express windows Catalog Windows Update N Accessories tec ES LabTool T400 Same d E startup amp Internet Explorer msn e Tour Windows XP PORE ERS Remote Assistance ro Files and Settings Tr E windows Media Player DI Wizard 3 Windows Messenger All Programs a Windows Movie Maker 2 O rumor compa S46UXP 200601 4 software install 202 Fig4 2 After run the LabTool T400 software you will see your LabTool T40 serial number with USB interface amp AE0404000002 LabTool T400 Turbo Flash Gang Programmer File Project Device Options Diagnostics View Help gt gt Found LabTool T400 AE0404000002 Device None Type None Adapter None Pin None n Size None VCC None Manufacture Code None Check Sum None Device Code None 1 3 File Current Count 0 25 4 la asa Q2 The O S can t find the LT T400 after power on Ans Stepl Install the LABTOOL T400 software If you do not have the software and you can download it
16. File Current Count 0 Note Flash 0 7fffff SecSi 800000 8000ff Current Failure 0 Figure 4 10 After Search Machine selection Statistic LABTOOL T400 can keep track of chip programming failures The lower right hand corner of the Run Time Viewer screen contains two entries Current Quantity and Total Fail These quantities automatically increment for every chip LABTOOL T400 attempts to program and for every programming failure Failures counted include chips that fail device ID check blank check verify pass protect and unprotect The user can input a target quantity of chips to be programmed in a production run and an allowable number of failures An alarm feature can be set so that when the target quantity or the allowable failures is reached an alarm message is displayed on the screen to alert the operator Menu Options Statistic Hot key F7 This command controls the setting of the Statistic Option Select the command using the mouse or tab key or the hot key Alt T The screen shown below will appear Use the mouse or tab between screen entries Fill in the desired quantities for Target Quantity and Maximum Fail and indicate your choice for alarm enabling or disablement Select the OK button and press enter to confirm your selections Click the Reset button to set statistic parameters to default 32 4E0403000003 LabTool T400 Turbo Flash Gang Programmer loj x File Project Device Options Diag
17. XA27x 56pin FBGA Adapter for S71PL 032 064 84 pin FBGA adapter modules for Spansion S71PL 254 64pin FBGA ADP for Sharp LRSxxxx 107pin FBGA Adapter for SAMSUNG 007M 137 pin FBGA adapter modules for Samsung K5D5613HCM D090 48 pin FBGA adapter modules for Samsung K 9F5608U0C HCBO 48pin FBGA Adapter for SST39L F800A 48 pin FBGA adapter modules for ST NAND256W3A 60pin FBGA Adapter for TH50V PF5782 834A SB 44pin PSOP Universa Adapter 48pin DIP Universal Adapter 48pin TSOP Universa Adapter 56pin TSOP Universa Adapter 36 APPENDIX Error Messages 37 Error Messages This function is not supported in demo mode When the LABTOOL T400 is not activated some functions may be inhibited Illegal range of erase address setting Retry again The address range for an erase command must match the sector edge Time Out error The LABTOOL T400 does not respond when the system times out Cannot open XXXXXXXX The file was not found or a disk error occurred Device ID Code unmatched The current chip s ID will be displayed File write error Illegal file name or disk error The LABTOOL T400 detected an error when writing a file to disk Check that there is enough space on the disk to hold the file Also check that the disk is not write protected This might happen on a network if you are a user that does not have rights to the directory you want to save the file to Use another directory or disk F
18. able adapters to fit your needs Other adapters will become available after release of new chips We have a device list and adapter note please reference http www aec com tw download LabTool T400_ALL pdf Adapter TM A 160 48F TM A3208 56F TM A640 48F TM F2228 56F TM 1128 56VF 1128 64 TM I128W 56VF TM I256 64E TM 1256K 63VF TM 1256L 63VF TM 13204 64F TM 13340 80FC TM 14050 80F 14400 137 5 TM 14470 137FS TM 1640 56VF TM 16408 64F TM IPXA27 336FS TM S064 56F TM S254 84F TM SH1826 64F 5500 107 TM SS5613 137F TM SS5616 48F TM SST800 48F TM STO1G 48F TM T5782 60F TM UNIV 44PS TM UNIV 48DIP TM UNIV 48TS TM UNIV 56TS Description 48 FBGA adapter for AMD Arr 9L V 160B 56pin FBGA ADP for AMD 41 42DL 32 64xx 48Pin FBGA adapter for AMD 29DL640D 56pin FBGA Adapter for MB84VD22280F 56pin VFBGA ADP for Intel GE28F128K WxD 64 pin EBGA adapter modules for nte RC28F 128K 3 56 pin uBGA adapter modules for Intel 28F128W18 30 T B 64Pin EBGA ADP for INTEL 28F256 3C 79pin VFBGA ADP for Intel GE28F 256K 63pin VFBGA ADP for Intd GE28F256 L K 18 30 FBGA ADP for Intel 28F3204C3 80pin FBGA ADP for Intel RD38F20 22 30 33xx 80pin FBGA ADP for Intel RD38F4050L 0Y BYT 137 pin FSBGA ADP for Intd 512 Mbit LX x32 137 pin FSBGA pitch 0 65 adapter modules for Intel PF38F4470VVUB 56pin VFBGA ADP for Intel GE28F640 W K L 18 30 FBGA ADP for Intel 28F6408 336pin FSBGA ADP for Intel P
19. alling the LABTOOL T400 22 2 22 2 2 16 Upgrading the LABTOOL T400 Software 16 Chapter 3 Command Hierarchy sese 17 LABTOOL T400 Command Hierarchy 18 Chapter 4 Operation eese iii 19 LED Display on Each 1 1 1 20 LED Color einer 20 Bile Commands anna 20 Save Buffer a LR Enid 20 Pile tret ere tete Rt t eere 21 Exit to WindoWi AS 22 Project Commands 1 1 1 ee eese seen 22 Save Project ica eu ehe 22 Load Project ira na a 22 Device Commiands cinici 22 Change Device uctor 22 Mass production Mode 2 22 2 23 Editing the Buffer iii t spina 25 Blank Checking a device eee 25 Reading device satin senken ERR eene n 25 Programming a device i 25 Verilying a device ica Li reed Pe e D ER EE Dod 26 Memory Protect oit eter eter ere He deret dene 27 Erasing a device petita er re Fee ee a e 27 COonfIg ration ter tt een 27 uL 28 Device operation Options iii 28 Module options ede een 30 Search Machine eee es 31 SED 32 ME A ee eina nea eee NUS PE Coe Peine 33 Self Test A S OS EU EE as 33 Chapter 5 Using Adapt
20. and you can download it from our website www aec com tw If you have installed the software skip this step Step2 Turn the LABTOOL T400 power on Step3 Select Start gt Control Console gt System gt Hardware gt Device Manager and you will see the LabTool T400 Turbo Flash Gang Programmer Step4 Run the LABTOOL T400 software Note Recommended O S in your PC 1 Windows XP SP1 2 Windows XP SP2 3 Windows 2000 SP4 41 Step1 Install the LABTOOL T400 software If you do not have the software you can download it from our website www aec com tw If you have installed the software skip this step Fig1 1 Extracting amp WinRAR self extracting archive Extracting LTT400 EXE Destination folder EXDOCUMEINYUHDIN 1 CHAALOCALS TA TempiBa Installation progress Fig1 2 Starting InstallShield Wizard Starting InstallShield Wizard Fig1 3 Installing LabTool T400 Turbo Flash Gang Programmer InstallShield Wizard Setup Status LabTool T 400 Turbo Flash Gang Programmer Setup is performing the requested operations Installing C Program Files kAECWWLTT400 GADA___ rez InstallShield Cancel 42 Fig1 4 Press Next LabTool T400 Turbo Flash Gang Programmer InstallShield Wizard Welcome to the InstallShield Wizard for LabTool T400 Turbo Flash Gang Programmer The InstallShield Wizard will install LabT ool T 400 Turbo Flash Gang Program
21. ately after they have been programmed Erasing a device Menu Device Erase Hot key CTRL E This function is a device specific command it appears on the main menu only after electronically erasable chips have been selected The function can be used to erase a desired memory range from a chip Configuration Menu Device Configuration Hot key CTRL G This function is a device specific command for a single Flash chip with a software protect block an option register configure word and lock bit The function must be configured before use When used 27 the memory protect configuration data will be burned into the chip s memory and will protect specified memory blocks Configuration ID Checking Erasing Blank Checking Programming Verifying at 3 31 00 01 12 26 Program completec ID Checking Verifying at 3 31 00 00 03 26 gt gt Verify completed immmm mmmm Figure 4 6 Example of device specific configuration screen Options Device operation options Menu Options Operation options Hot key F4 28 amp 4E0403000003 Lab Tool Te File Project Device Optio Save Load Select Aut Number Settings gt gt Macronix MX29LV64 Start Address End Address Start Erase 9 End Erase seri Tiner General Option Insertion Test v Device ID Check Program Option Auto Ersse OvrWr v Bla
22. can be set to either of two modes standard mode or concurrent mode In standard mode LABTOOL T400 programs the devices in all 4 adapter sockets at one time Note The insertion test must be enabled to use mass production mode 450403000003 LabTool T400 Turbo Flash Gang Programmer x File Project Device Options Diagnostics View Help Ea ss xg Save Load Select amp utolD Edit Read Blank Prog Verify Erase Prot Config Option gt gt Macronix MX29LV640B 48 5 St ass Pro Module 0 Module 2 Insert Pls Insert Pls Current Qty Tartget Qty 1000 Total Fail Module 3 Devi Module 1 LI evice Adapter 1 Insert Pls Insert Pls Size 2 Check Sum Ins Timer File Note Figure 4 2 Standard mass production mode screen An insertion timer is included for use with the insertion test When a chip fails an insertion test and the insertion timer is disabled the LABTOOL T400 will alert the operator to the failure and require either that the problem be corrected or that the operator acknowledge the failure before continuing with programming When a chip fails and the insertion timer is enabled the LABTOOL T400 waits the amount of time set into the insertion timer This is to give the operator time to correct the error If the error is not corrected in time the error socket shuts down and all the devices in good sockets
23. e InstallShield Wizard which will quide you through the rest of the setup process Please wait 8 0 L 51 Fig1 4 Press Next LabTool T400 Turbo Flash Gang Programmer InstallShield Wizard Welcome to the InstallShield Wizard for LabTool T400 Turbo Flash Gang Programmer The InstallShield Wizard will install LabT ool T 400 Turbo Flash Gang Programmer on your computer To continue click Next Fig1 5 Press Install Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard InstallShield 52 Fig1 6 Installing Setup Status LabTool T400 Turbo Flash Gang Programmer Setup is performing the requested operations Installing C Program Files AECWWLTT400 GADA___ rez InstallShield Fig1 7 Press Finish LabTool T400 Turbo Flash Gang Programmer InstallShield Wizard InstallShield Wizard Complete The InstallShield Wizard has successfully installed LabT ool T 400 Turbo Flash Gang Programmer Click Finish to exit the wizard Finish Cancel 53 Step2 Turn the LABTOOL T400 power on Step3 Select Start gt Control Console gt System gt Hardware gt Device Manager You will see the USB Device in your PC Fig3 1 Press Device Manager System Properties
24. e size as the device size If you want to download a file into memory that is bigger than the active device insert the size here or in Options Operation Options Clear Buffer Before Loading the file Four options are available during memory buffer data loading The default option is to clear the buffer to its blank state prior to data loading Disable 21 This option leaves the original buffer data unchanged but then overwrites it with the contents of the newly loaded file Clear buffer with blank state This option clears the buffer to the device blank state using command 00 or FF depending on device selection then overwrites the buffer during file loading Clear buffer with zeros 0x00 First clears the buffer of its contents using command 00 then overwrites the buffer with the new file contents Clear buffer with ones OxFF First clears the buffer of its contents using command FF then overwrites the buffer with the new file contents Exit to Windows Menu File Exit Hot key Alt X Quit the LABTOOL T400 program and exit Project Commands Save Project Menu Project Save Project Hot key Alt F1 This option saves the current setup of the LABTOOL T400 software into a project file The file includes devices selected buffer data operation options setup and device configuration setup You can also attach a footnote to this project file The project file acts as a macro eliminating the need to go through each pr
25. ers 244 4 4 8 110 35 Adapter 36 Appendix Error 37 Error Messages u ana a ae 38 Appendix B Troubleshooting seen 40 Q1 How to install the LABTOOL T400 software 41 Q2 The OS can t find the LT T400 after power on 50 Quick Start Quick Start 0 1 2 3 4 5 6 7 8 9 10 11 We have a detail installing processes in Q1 of Q amp A in Appendix B page 41 The LABTOOL T400 must be turned off before you install its software Install LABTOOL T400 s software Turn on your LABTOOL T400 and then the O S will detect the USB device and press Continue Anyway to finish the installation Run the LABTOOL T400 software Select the chip type to be programmed first Use the Hot key ALT C and then type the complete part number of the chips to be programmed or use the mouse to select the correct part number Load the design file into the buffer Use the Hot key ALT L then specify the origin of the file and load Alternatively you can read a master chip into the buffer instead of a design file The default master module is Module 0 By putting a chip into Module 0 and performing the Read operation Hot key ALT R you can transfer the chip s content
26. from our website www aec com tw If you have installed the software skip this step Step2 Turn the LABTOOL T400 power on Step3 Select Start gt Control Console gt System gt Hardware gt Device Manager You will see an USB Device in your PC Step4 Uninstall the USB Device Step5 Turn the LABTOOL T400 power off Step6 Turn the LABTOOL T400 power on and then the OS found out a new USB device from your USB interface Step7 Select Start gt Control Console gt System gt Hardware gt Device Manager and you will see the AEC LabTool T400 Turbo Flash Gang Programmer Step8 Run the LABTOOL T400 software Note Recommended O S in your PC 4 Windows XP SP1 5 Windows XP SP2 6 Windows 2000 SP4 50 Step1 Install the LABTOOL T400 software If you do not have the software and you can download it from our website www aec com tw If you have installed the software skip this step Fig1 1 Extrating gt WinRAR self extracting archive Extracting LT T 400 EXE Destination folder EC NDOCLUME 1NYUHDIN 1 CHASLOCALS 1NTempsRa Installation progress Fig1 2 Starting InstallShield Wizard Starting InstallShield Wizard Fig1 3 Preparing LabTool T400 Turbo Flash Gang Programmer InstallShield Wizard Preparing Setup Please wait while the InstallShield Wizard prepares the setup LabTool T 400 Turbo Flash Gang Programmer Setup is preparing th
27. ile read incomplete The user break file format was unmatched or a disk error occurred during file reading LABTOOL T400 not found Do you want to retry The LABTOOL T400 software does not detect the LABTOOL T400 on one of the USB ports Press enter to retry or press F6 to search machine Press Esc to enter demo mode Make sure the power on the LABTOOL T400 is on Also check the parallel connection between the PC and the LABTOOL T400 If the LABTOOL T400 shares the USB port with another device remove the other device or move the LABTOOL T400 to its own port 38 LABTOOL T400 power off or disconnected from The LABTOOL T400 software does not detect LABTOOL T400 on one of the USB ports Make sure the power on the LABTOOL T400 is on Also check the USB connection between the PC and the LABTOOL T400 and between the PC and the USB port If the LABTOOL T400 shares the USB port with another device remove the other device or move the LABTOOL T400 to its own port Other Error Messages The following list of error messages uses the code XXXX where XXXX can be Read Verify Blank Check Program Erase or Memory Protect Aborted has the same meaning as user break XXXX Aborted XXXXX error found XXXX error on Module X Address 39 APPENDIX Troubleshooting 40 amp Q1 How to install the LABTOOL T400 software Ans Stepl Install the LABTOOL T400 software If you do not have the software
28. is the programming speed of LABTOOL T400 with different algorithm implement Device Chip Size Blank Programming Verifying Total Blank Check check Programming Verifying STM28W640W 64M bit 1 65s 11 58 1 3 25 16 355 GE28F640W30B 64M bit 1 655 16 65 2 3 28 21 455 GE28F128W30 128M bit 3 3s 33 25 2 6 4s 42 95 Am29DL640G 64M bit 1 655 29 55 3 3 28 34 555 NAND512W3A 512M bit 355 95s 60 255 190 255 6 4 K9F2G08U0M 2G bit 131s 357 48s 200 95s 689 43s 6 5 1 STM 4 word algorithm 2 Intel EFP algorithm 3 SPANSION word algorithm 4 Small page NAND flash 5 Large page NAND flash 6 Programming the maximum memory size of that chip There are many NAND flash options in LABTOOL T400 please reference NAND flash programming in LT T400 3 3V to 1 2V chip in VCC and I O support The LABTOOL T400 use the 90nm FPGA chip in the hardware design it can handle the chip from 3 3V to 1 2V in both VCC and I O without special low voltage converter circuit This new technology fulfils customer s need and makes customer s investment fully protected 10 High density chip support LABTOOL T400 has reserved the growth potential in chip s density It covers 8 16 bit flash today and 32 bit flash chip in the future Its I O pin driver can cover flash with maximum 128G bit in density This growth potential protected customer s investment withou
29. isable When the insertion timer is disabled and an error is detected during insertion testing the LABTOOL T400 waits for the operator to either correct the error condition or to acknowledge and bypass the error 29 When the insertion timer is enabled the LABTOOL T400 waits a specified period for the operator to correct the condition and if no correction is made shuts down the socket s reporting the error and completes programming of the remaining sockets Insertion Timer This option sets the time out interval for the insertion test When the insertion timer is enabled and an insertion error is detected if the operator fails to correct the problem within the interval set the LABTOOL T400 will automatically shutdown the error socket and complete programming of the remaining sockets If multiple errors exist in different sockets and the operator corrects one of the sockets the timer resets and waits the specified time for each succeeding error Time out intervals can be set from 1 to 999 seconds The default value is 5 seconds Insertion Test This option performs the device insertion check of the chips in the sockets The insertion check includes poor pin contact pin count mismatch the pin count of the chip designated in the software does not match the pin count of the actual chip in the socket device in wrong position device upside down short circuit between pins and chip damage Results are displayed at each socket s LED De
30. k Start Our special Quick Start section gives experienced users the information they need to setup the LABTOOL T400 and software and basic guidelines on using the LABTOOL T400 If you need more information you can refer to the rest of the manual If you have any problems you can work through the manual step by step for easy troubleshooting If you have any questions feel free to call your local distributor or sales representative Software update Please visit our website at_www aec com tw to update the software Device List with Adapter Note Please visit our website at www aec com tw download LabTool T400_ALL pdf to search supported chip and a compatible adapter Packing list Before you begin installing your LABTOOL T400 please make sure that the following materials have been shipped 1 LABTOOL T400 turbo gang programmer Power cord e 1 Power Adapter USB cable CD ROM containing the Windows software Contents Chapter 0 Quick Start eese 7 Quick Start a as 8 Chapter 1 General Information eene 9 Introduction az eee in nenn 10 Features er sn OE 10 Using the LABTOOL T400 Software 13 Chapter 2 Installation sese 15 Minimum PC System Requirements esee 16 Installing the LABTOOL T400 Software 16 Inst
31. lashing in the Type box Use the up and down arrows to go to the appropriate type Press the space bar to select the type 2 Enter the part number the manufacturer number or parts of both in the Search box Mouse Click on Search Type in the characters Keyboard Press TAB until the cursor flashes in the Search box Type in the known characters All the devices that satisfy this partial information will be displayed Use the mouse to select a device and click OK If you are not using a mouse use the TAB key to skip between the various screens and use the arrow keys to move around in each screen Mass production Mode Menu Device Mass Produce Hot key Alt M 23 The LABTOOL T400 is a mass production programmer for manufacturing When placed in mass production mode all keyboard and mouse functions are disabled and the operator needs only to insert the chips into the sockets wait until the green LED next to each socket lights up remove the programmed chips and insert new chips Anyone can do the job well without special training or skills Since all keyboard and mouse functions are disabled the possibility of errors being caused by pressing the wrong keys or changing the buffer s contents are eliminated In mass production mode the LABTOOL T400 first performs an insertion test and an ID check on newly inserted chips It then automatically programs the chip In mass production the LABTOOL T400
32. mer on your computer To continue click Next Fig1 5 Press Install Ready to Install the Program The wizard is ready to begin installation Click Install to begin the installation If you want to review or change any of your installation settings click Back Click Cancel to exit the wizard InstallShield 43 Fig1 6 Installing Setup Status LabTool T400 Turbo Flash Gang Programmer Setup is performing the requested operations Installing C Program Files AECWWLTT400 GADA___ rez InstallShield Fig1 7 Press Finish LabTool T400 Turbo Flash Gang Programmer InstallShield Wizard InstallShield Wizard Complete The InstallShield Wizard has successfully installed LabT ool T 400 Turbo Flash Gang Programmer Click Finish to exit the wizard Finish Cancel 44 Step2 Turn the LABTOOL T400 power on You will see the messages Fig2 1 Select No not this time and then press Next Found New Hardware Wizard Welcome to the Found New Hardware Wizard Windows will search for current and updated software by looking on your computer on the hardware installation CD or on the Windows Update Web site with your permission Read our privacy policy Can Windows connect to Windows Update to search for software O Yes this time only O Yes now and every time connect a device Click Next to continue Fig2 2 Select Install the software automatically Recommended
33. n load file save file project file load save File format Binary Intel HEX Intel extend HEX Motorola S HP64000A BS HEX straight Hex General Power adapter 65W 100 V AC to 240V 47 63 Hz auto switch Output DC 12V 3A DC5V 7A Operation temperature 5 to 45 41 to 113 F Safety CE amp LVD certified Shipment Weight 5 0 Kg without module adapter Using the LABTOOL T400 Software Menus Accessing the menus can be done in two ways Use the mouse and click on the menu option displayed at the top of the screen A pull down menu will appear and you can select the option you desire by clicking on that option If you do not have a mouse available you can also use the keyboard to access the menus Press F10 to activate the main menu bar Select the sub menu that you want to use with the left and right arrow keys and press ENTER to activate the sub menu Use the up and down arrows to select an option to execute Press ENTER to execute the command Hot keys Most of the options available on the menus can also be executed by pressing the hot key associated with that option To see what the hot key is for a certain option look on the menu where the option is located If a hot key is available it will be displayed next to the option name 13 Editor s Note See Diagram in original manual En Change oa Mass Production Mode Edit Sub Menu Read
34. ng LED 5 Hz frequency This mode only applies to insertion and contact checks of the chips in the socket Flashing Green the chip passed the continuity check Flashing Yellow the adapter module is active and waiting for a chip to be inserted Flashing Red the chip failed the insertion continuity check due to poor contact incorrect chip positioning pin count mismatch chip upside down pin short circuit or chip damage File Commands Save Buffer Menu File Save Buffer Hot key Alt S This option is used to save the memory buffer to a file on the hard disk Select a file to overwrite using the mouse or type the file name in the box provided You can also type in a file spec e g hex bin at the Name prompt This will display all the files of the specified type and you can then select the required file to overwrite File Format Select the file format of the output file Buffer Mode This mode functions as follows Normal Every byte is written to the output file Even 1 of 2 Every Even byte is written to the output file odd 2 2 Every Odd byte is written to the output file 20 lst byte of 4 This writes the bytes 1 5 9 13 into the output file 2nd byte of 4 This writes the bytes 2 6 10 14 into the output file 3rd byte of 4 This writes the bytes 3 7 11 15 into the output file 4th byte of 4 This writes the bytes 4 8 12 16 into the output file From Buffer
35. nk Check IV Program IV Verify Pass MemProtProgConf Erase after Program Erase Option JV Device ID Check UnProtect Device Macror v Blank Check Adapter TM UN Verify Option Insertion Timer Size 40008 C Twice VCC 51 Disable Check Sum 7F80FF C Twice VCC 101 Enable Once File Note Flash Figure 4 8 Example screen Device specific operation options The following options can be set Start address End address This is the start and the end address of the edit buffer If you want to program a certain area of a device you can change the start and end addresses accordingly This option is only displayed when the device can be programmed in this way When the end address is calculated it divides the buffer size by device bits 8 bits A 16 bit device of which the buffer size is 80 Hex will therefore have an end address of 3F When selecting a start or an end address you should align the buffer on the right boundary single word for 8 bit devices double word for 16 bit devices etc Erase start end address This option is for electronically erasable Flash chips only The default setting of this option will erase the entire chip However a user can specify ranges of blocks to be erased data in the remaining blocks will be unchanged A user should reference the chip data book or configuration menu when setting the ranges of blocks to be erased Insertion Timer Enable D
36. nostics View Help 4 B Load EE Edit Ea Read 21 s Prog al Prot Els gt gt Found LabTool T400 AEO0403000003 Statistic Configuration Current Count o E Target Count 1000 Current Failure o 3 Max Failure 5 Device Macronix Statistic Alarm Adapter TM UNIV 487 Disable Size 400080hx16 Enable Check Sum 7F80FF00h File Note Flash 0 7iffff SecSi 800000 8000ff 1 3 Current Count Current Failure 0 Ready NUM Figure 11 Statistic option selection screen Diagnostics Commands Self Test Menu Diagnostics Self Test Hot key F8 This option is used to self test LABTOOL T400 Remove all devices from the modules and then press Enter to start self test function In the C Program Files AEC WLTT400 folder there is a serial number text file of the LABTOOL T400 e g AE0403000003 txt after the self test function The file includes system information and hardware tested result If you need to update or upgrade or repair the LABTOOL T400 please send the text file e g AE0403000003 txt to us We will do our best service for you 33 Using Adapters 35 Adapter requirements The LABTOOL T400 supports 48 TSOP 56 pin TSOP uFBGA uVFGBA uBGA BGA ect packages You will need to order an adapter for your chip package You can order the following avail
37. ocedure during future programming sessions Load Project Menu Project Load Project File Hot key Alt F2 This option loads the desired project file After the project file has been loaded you can immediately program the chip using the data and setup functions selected Device Commands Change Device Menu Device Change Hot key Alt C This option is used to select a new device as the active device It is important to select the correct device as the algorithms used to program devices are device specific The following screen will appear 22 45040300000 3 LabTool T400 Turbo Flash Gang Programmer File Project Device Options Diagnostics View Help Save Loac Check Sum 7F80FF00h 12 00V Device Code 22CBh Change current device Change F Mass Production AlttM Config Option Edit Read AlttR Blank Check Alt B Program AlHP Verify Alv Memory Prot Prog Config Alte Y Erase Device Macronix MX29LY640B 48TS Adapter TM UNIV 48TS Pin 48 n 2 Size 400080hX16 VCC 3 30V Manufacture Code 1 3 Current Count 0 Current Failure 0 File Note Flash 0 7f fff 5ecSi 800000 8000ff Figure 4 1 Screen for selecting Change Device 1 Select the type of device that will be the active device Mouse Click on EPROM Flash Keyboard Press TAB until the cursor is f
38. ows Update for drivers Hardware Profiles E Hardware profiles provide a way for you to set up and store ze different hardware configurations Hardware Profiles Fig7 2 You will see the AEC LabTool T400 Turbo Flash Gang Programmer below your Universal Bus controllers E Device Manager File Action Help E BE Network adapters e Other devices 2 e Multimedia Audio Controller Ports COM amp LPT FR Processors o Sound video and game controllers JB System devices Universal Serial Bus controllers AEC LabTool T400 Turbo Flash Gang Programmer Intel R 82801BA BAM USB Universal Host Controller 2442 Intel R 82801BA BAM USB Universal Host Controller 2444 NEC PCI to USB Enhanced Host Controller B1 NEC PCI to USB Open Host Controller NEC PCI to LISB Open Host Controller LISB Root Hub LISB Root Hub LISB Root Hub LISB Root Hub LISB Root Hub 60 Step8 Run the LABTOOL T400 software Fig8 1 Select Start gt All Programs gt Advantech LabTool gt LabTool Internet lt 2 Documents E Internet Explorer e 2 5 Set Program Access and Defaults 5 E mail Outlook Express windows Catalog Windows Update Accessories LabTool T400 Games E startup amp Internet Explorer 7 msn e Tour Windows XP DM cune Exe Remote Assistance ro Files and Settings Tr E windows Media Player DI Wizard
39. re and software After entering the Mass production Mode the production line operator inserts a chip in to the adapter module the LED on the LABTOOL T400 indicates the chip is busy or good or error the operator follow the LED and take necessary action to remove or insert the chip No formal training is needed In addition the LABTOOL T400 s auto sensing feature ensures the chip inserted correctly and automatically programs the chip without press any key Furthermore in the Mass production mode the system module the system keyboard is automatically disabled to prevent any inadvertent mistakes Project file Save and Load You can save the program configuration project file which contains the device selection the buffer data and all of the program setup options This file can be recalled at any time for future use without having to go through the setup procedure again This allows you to pass your design file to the production department without mistakes You can also read the data from a chip into the buffer from any of 4 adapter modules according to your specification Target quantity and maximum failure rate alarm The LabtTool T400 automatically keeps a running total of all production pieces attempted and all production pieces failed Users can input a target quantity of chips to be programmed and an allowable number of failures An alarm function can be enabled to send a message to the screen alerting the user to either the target quantity of
40. s into the buffer You can also select any module as the master module Go to the main menu select the module options Hot key F5 then set the master module insert a master chip into the master module and perform Read Insert 4 chips of the same type into 4 sockets set the device operation option Hot key F4 then perform Program Hot key ALT P You can now program the 4 chips simultaneously To speed up throughput a user can change the mode to Mass production mode Hot Key Alt M After entering this mode the LABTOOL T400 will program chips automatically after they are properly inserted into the socket of module LABTOOL T400 only has a standard mass production mode Standard mode allows the LABTOOL T400 to program 4 devices at the same time A user can enable the insertion timer and adjust the timer Enabling the timer will allow LABTOOL T400 to automatically shutdown a poor contact socket upon timeout of a user set timer period LABTOOL T400 then automatically programs the chips in the remaining good sockets The insertion timer default setting is 5 seconds When the insertion timer is disabled the user will have to either correct the insertion error or press the ignore key to continue programming after a poor contact socket is discovered LABTOOL T400 also automatically keeps a running total of all chips that have been through programming and all chips encountering programming failures A user can input a target quantity of chips to
41. sh to close the wizard Cancel 47 Step3 Select Start gt Control Console gt System gt Hardware gt Device Manager and you will see the LabTool T400 Turbo Flash Gang Programmer Fig3 1 Press Device Manager System Properties _ System Restore Il Automatic Updates Remote 1 General Computer Name Hardware Advanced Device Manager IT The Device Manager lists all the hardware devices installed on your computer Use the Device Manager to change the properties of any device Device Manager Drivers p Driver Signing lets vou make sure that installed drivers are compatible with Windows Windows Update lets you set up how Windows connects to Windows Update for drivers Windows Update Hardware Profiles Hardware profiles provide a way for you to set up and store different hardware configurations Hardware Profiles Fig3 2 You will see the AEC LabTool T400 Turbo Flash Gang Programmer below your Universal Bus controllers Device Manager File Action Help R zag 72 Monitors BB Network adapters Other devices 27 Ports COM amp LPT MB Processors e Sound video and game controllers J W System devices Universal Serial Bus controllers LabTool T400 Turbo Flash Gang Programmer Intel R 82801BA BAM USB Universal Host Controller 2442 Intel R 82801BA BAM USB Universal Host Controller 2444 NEC PCI to USB
42. t purchasing a new generation programmer over a decade in future Expansion through USB Hub and configure as a multi station asynchronous gang programmer The LABTOOL T400 interface with PC through USB interface which support USB1 1 and USB2 0 If customer needs more units in production just purchase extra LABTOOL T400 and connect those LABTOOL T400 through USB Hub up to 127 LABTOOL T400 can be attached to one PC Recommend with 4 16 units LABTOOL T400 control by one PC to avoid performance decrease Such configuration has significantly reduced the cost per station with low initial purchase cost and growth potential in future Adapter modules with ID The LABTOOL T400 adapter module has independent ID After inserting the module in LABTOOL T400 system will detect the ID of module and compare the corresponding adapter modules with the chip select in software This feature prevents the wrong adapter module insert or wrong chip selection in operation Device insertion and continuity checks No mistakes The LABTOOL T400 performs device insertion and continuity checks before programming each device It can detect poor pin contact upside down device insertion incorrect position and pin number mismatch This function protects your pocketbook by preventing expensive chip damage caused by operator error Auto sensing and self programming To meet mass production requirements the LABTOOL T400 has implemented patented technology in both its hardwa
43. u are installing for this hardware AEC LabTool T 400 Turbo Flash Gang Programmer has not passed Windows Logo testing to verify its compatibility with Windows Tell me why this testing is important Continuing your installation of this software may impair or destabilize the correct operation of your system either immediately or in the future Microsoft strongly recommends that you stop this installation now and contact the hardware vendor for software that has passed Windows Logo testing Continue Anyay STOP Installation 58 Fig6 5 Press Finish Found New Hardware Wizard Completing the Found New Hardware Wizard The wizard has finished installing the software for 2 AEC LabT ool T 400 Turbo Flash Gang Programmer Click Finish to close the wizard Cancel 59 Step7 Select Start gt Control Console gt System gt Hardware gt Device Manager and you will see the AEC LabTool T400 Turbo Flash Gang Programmer Fig7 1 Press Device Manager System Properties System Restore Automatic Updates Remote 1 General Computer Name Hardware Advanced Device Manager The Device Manager lists all the hardware devices installed onyour computer Use the Device Manager to change the properties of any device Drivers Driver Sianing lets vou make sure that installed drivers are compatible with Windows Windows Update lets you set up how Windows connects to Wind
44. vice ID Check This option performs a device signature and manufacturer match test With the chip selected and plugged into a socket LABTOOL T400 checks the device ID and displays the results of each check on the LED display Verify Passes Checking this option will instruct the LABTOOL T400 to perform device verification with the buffer data when programming is complete When verify passes is enabled one of the three verify options as described below must be set Verifying Options The following three options are available for verification of data retention following programming verify twice with 5 V c verify twice with 10 V and verify once with V c These options will only be enabled if the Verify passes option see above is enabled e Twice V 5 5 When this option is selected the LABTOOL T400 will do two verify passes on the device one using Voc 5 the other V 5 Example IF Vis 3 3 V the LABTOOL T400 will do one verify pass using a V of 3 465 V and one using a V of 3 135 V e Twice V 10 When this option is selected the LABTOOL T400 will do two verify passes on the device one using Vcc 10 the other 10 Module options Menu Options Module options Hot key F5 30 This option is used to select the master module location default module 0 and enable disable the module 4E0403000003 LabTool T400 Turbo Flash Gang Programmer E loj File Project Device
45. y another command the Undo command will not undo the changes Blank checking a device Menu Device Blank Check Hot key Alt B This option checks if the active device is in its erased state It will return a message stating Device not blank at the first occurrence of data in the device The address where the data is found will also be displayed Reading a device Menu Device Read Hot key Alt R This option reads a master chip into the memory buffer for duplication of the master chip Prior to executing this command a master socket must be designated and the master chip inserted into the master socket The default master socket is socket 0 Programming a device Menu Device Program Auto Hot key Alt P 25 This option programs the active device with the contents of the memory buffer When the programming is complete verification will take place The type of verification depends on the verification options set in the Options Operation options menu inl x File Options Diagnostics View Help lol alma eel lalalala selon ne acronix ID checking Module 0 Module 2 Erasing 28 28 Blank Check Current Qty Programming A Verifying a 00 01 07 29 Program com Target Qty ID Checking 1000 Erasing Blank Check 1 gt gt Programming Module 1 Module 3 Total Fail 2896 2896 0 Device Max Fail Adapter 5 Size Check Sum

Download Pdf Manuals

image

Related Search

Related Contents

Manual de instalación Módem Starbridge  MANUAL DE USUARIO MODULO DE ESTUDIANTES WEB  Bluworld of Water WWLVCJ-BL Instructions / Assembly  IPower Control 4 DIN s www.lindy.com  Descargar MANUAL TECNICO MOTOR LINCE  Toshiba Satellite Pro C650-EZ1523D  aviso - The Pool Factory  Ingenuity Variant Analysis Plugin  Philips DS1200  Dossier Biodiversité P 8 - La Communauté de Communes Nord du  

Copyright © All rights reserved.
Failed to retrieve file