Home

Line Seiki

image

Contents

1. MIERUzzO DK 5000 Series Electronic Tally Device MIERUZZO SOFTWARE USER S MANUAL DK 5005A DK 5010A DK 5030A DK 5005B DK 5010B DK 5030B DK 5005C DK 5010C DK 5030C This manual was last revised March 17 2015 Contents are subject to change even without prior notice All Rights Reserved Copyright 2015 LINE SEIKI CO LTD DK 5000 Series Mieruzzo Software User s Manual TABLE OF CONTENTS SECTION 1 System Requirements 0 System Requirements 1 SECTION 2 Usage Instructions 1 Installing DK 5000 Mieruzzo Software and Driver 2 1 1 DK 5000 Mieruzzo Software Installation 1 2 DK 5000 Device Driver 2 Connecting Disconnecting a DK 5000 Device 8 2 1 Connect a DK 5000 Device 8 2 2 Disconnect a DK 5000 Device 11 3 Data Communication with DK 5000 Device 12 3 1 A Auto Acquire Present Data 12 3 2 Acquire Present Data 14 3 3 Acquire All Records 15 3 4 Delete a Specific Record 18 3 5 Clear All Records 20 4 Exporting Records to a File 22 4 1 Export a Specific Record 22 4 2 Export All Records 23 5 Changing Device Settings 25 5 1 Set Device ID 25 5 2 Synchronize DK 5000 Device Time with System Time 26 6 Miscellaneous Functions 27 6 1 View Device Firmware Version 27 6 2 Check for Software Updates 27 6 3 View Software Instruction Manual 28 6 4 View Software Version 28 SECTION 3 Frequently Asked Questions 7 Frequently Asked Questions 29 WE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual
2. Timestamp Total Counter Counter2 Counter3 Counter4 Counter 5 1 2014 11 30 08 02 04 75 6 11 28 29 2 3 2014 11 30 19 27 26 22 4 2014 11 30 08 44 52 24 3 7 6 lt 08 Delete Record Model DK 5005A Device ID 000 Records 4 18 QE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual To delete a Record in Type B or Type C devices right click on the Tab Title of the Record to be deleted and then select Delete Record File Device Help Auto Acquire jj Acquire All Records IA Export All Records I 2014 11 30 Delete Record 1 2014 11 30 08 20 40 2014 11 30 08 21 24 2014 11 30 08 21 39 Timestamp Total Input 1 Input 2 Input 3 Input 4 Input 5 Timestamp Total Input 1 Input 2 Input 3 Input 4 Input 5 mo EN E sr ane 22 AA Aa sa 2 2014 11 30 08 12 39 1 0 0 0 1 0 3 2014 11 30 08 12 39 2 0 0 1 1 0 4 2014 11 30 08 12 39 3 0 1 1 1 0 5 2014 11 30 08 12 39 4 0 2 1 1 0 6 2014 11 30 08 12 39 5 1 2 1 1 0 7 2014 11 30 08 12 39 6 1 3 1 1 0 8 2014 11 30 08 12 39 7 2 3 1 1 0 9 2014 11 30 08 12 39 8 2 3 2 1 0 10 2014 11 30 08 12 39 9 2 2 1 0 11 2014 11 30 08 12 40 10 3 B 2 1 0 12 2014 11 30 08 12 40 11 3 lt 2 2 0 13 2014 11 30 08 12 41 13 3 lt 3 2 1 14 2014 11 30 08 12 41 14 3 2 1 15 2014 11 30 08 12 41 15 3 B lt 2 2 4 Start Time 2014 11 30 08 12 36 End Time 2014 11 30 08 13 1
3. GWE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 0 SYSTEM REQUIREMENTS Below are the minimum system requirements to install and run the DK 5000 Mieruzzo Software Operating System Windows 7 8 8 1 Disk Space Application 50MB d Java Runtime Environment 160MB NE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual INSTALLING DK 5000 MIERUZZO SOFTWARE AND DRIVER 1 4 DK 5000 MIERUZZO SOFTWARE INSTALLATION 1 1 1 Double click or run the software installer DK 5000MieruzzoSoftwareS sionl OBuild 3_200215 exe GAA DK 5000 Mieruzzo Software Setup tupVer 1 1 3 The DK 5000 Mieruzzo Software Setup Wizard will start Click Next to continue with the software installation Welcome to the DK 5000 Mieruzzo Software Setup Wizard This will install DK 5000 Mieruzzo Software version 1 0 on your It is recommended that you dose all other applications before Click Mext to continue or Cancel to exit Setup NE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 1 1 4 Select the default installation folder or browse for a new location Click Next to continue with the software installation il Setup DK 5000 Mieruzzo Software Select Destination Location Where should DK 5000 Mieruzzo Software be installed A Setup will install DK 5000 Mieruzzo Software into the following folder To continue dick Next If you would like
4. Timestamp Total Input 1 Input 2 Input 3 Input 4 Input 5 1 2014 11 30 08 12 36 0 0 0 0 0 0 1 2 2014 11 30 08 12 39 1 0 0 0 1 0 3 2014 11 30 08 12 39 2 0 0 1 1 0 4 2014 11 30 08 12 39 3 0 1 1 1 0 5 2014 11 30 08 12 39 4 0 2 1 1 0 6 2014 11 30 08 12 39 5 1 2 1 1 0 7 2014 11 30 08 12 39 6 1 3 1 1 0 8 2014 11 30 08 12 39 7 2 3 1 1 0 9 2014 11 30 08 12 39 8 2 3 2 1 0 10 2014 11 30 08 12 39 9 2 4 2 1 0 11 2014 11 30 08 12 40 10 3 4 2 1 0 12 2014 11 30 08 12 40 11 3 4 2 2 0 13 2014 11 30 08 12 41 13 3 4 3 2 1 14 2014 11 30 08 12 41 14 3 4 4 2 1 15 2014 11 30 08 12 41 15 3 4 4 2 2 Sa lau Bema 1 Start Time 2014 11 30 08 12 36 End Time 2014 11 30 08 13 11 Export Record Number of Logs 170 QE LINE SEIKI ie DK 5000 Series Mieruzzo Software User s Manual 3 3 3 The software will display messages for three 3 conditions that indicate the status of available memory on the device 3 3 4 1 No Records In Memory A warning message will be displayed to indicate that Acquire All Records is attempted but there are no Records saved in the device memory Warning i Mo record found 7 Warning Code 4 3 3 4 2 Device Memory Low Memory Low message will be displayed if device memory usage is between 80 100 en E Information Device memory is LOW 3 3 4 3 Device Memory Full Memory Full message will be displayed if 10096 of device memory is used This ser
5. Why can t I sync the time on my DK 5000 device to the PC time It is possible that your device is in Recording or Count Mode There are restrictions to setting the time when the device is not on Standby Mode for Type B and C devices Make sure you go to Standby Mode first before syncing the time 4 Why can t I change the time on my DK 5000 device It is possible that your device is in Recording or Count Mode There are restrictions to setting the time when the device is not on standby mode for Type A and B Make sure you go to standby mode first before setting the time 5 Whycan tl change the Device ID on my DK 5000 device You cannot change the Device ID on your DK 5000 device if it is connected to the DK 5000 Mieruzzo Software Use the Set Device ID function of the software to change the Device ID NE LINE SEIKI D DK 5000 Series Mieruzzo Software User s Manual 6 lalready disconnected the device from the software why can t I change the Device ID on my DK 5000 device It is possible that your device is in Recording or Count Mode There are restrictions to editing the Device ID when the device is not on Standby Mode for Type B and C devices Make sure you go to Standby Mode first before changing the Device ID 7 Why are my old records missing in the device memory Your DK 5000 has limited memory and will erase the earliest record to free up space for new ones To avoid this please refer to the manual and save your
6. displayed on the DK 5000 device Click File in the menu bar and then select Acquire Present Data File gt Acquire Present Data Device Help Acquire Present Data Ctrl G Acquire All Records Ctrl D Export All Records Ctrl K Exit Ctrl X or click Acquire Present Data button File Device Help Acquire Present Data Acquire All Records ig Connection Export All Records A successful Acquire Present Data command will show the present data displayed on the DK 5000 device Additionally it will update the number of Records shown in the device details File Device Help Acquire Present Data Ut Acquire All Records Export All Records Present Last Update Time 2014 12 19 09 50 23 CENE EEE Rar RESI n Model DK 5005C Device ID 000 Records 0 14 QE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 3 2 3 This function can be executed only when device is in Count Mode If Acquire Present was Device is in Standby Mode Cannot display present data Error Code 1 3 3 ACQUIRE ALL RECORDS This function enables the software to show all the records saved in the memory of DK 5000 devices All Record details can be viewed and there is also an option to export Records to a spreadsheet or delete a specific Record 3 3 1 Click File in the menu bar and then select Acquire All Records File gt Acquir
7. records using our DK 5000 Mieruzzo Software before clearing the device memory 8 Why don t I get back to the default folder DK 5000 when I export my records We have an initial folder DK 5000 but the software remembers the last folder where the user saved last export You may choose not to use the DK 5000 folder But you should be able to find it again under your Documents folder For more information please visit www lineseiki com This manual was last revised March 17 2015 Contents are subject to change even without prior notice All Rights Reserved Copyright 2015 LINE SEIKI CO LTD NE LINE SEIKI 20 ve LINE SEIKI LINE SEIKI CO LTD Head Office 37 7 Chuo cho 2 Chome Meguro ku Tokyo JAPAN 152 0001 Contact TEL 03 3716 5151 FAX 03 3710 4552 E mail webtrade line co jp URL http www lineseiki com
8. to select a different folder click Browse rogram Files x86 W ine SeikiWMieruzzoWK 5000 Mieruzzo Software At least 153 8 MB of free disk space is required 1 1 5 Select the default location of program s shortcut or browse for a new location Click Next to continue with the software installation Bl Setup DK 5000 Mieruzzo Software Select Start Menu Folder Where should Setup place the program s shortcuts i Setup will create the program s shortcuts in the folowing Start Menu folder To continue dick Next If you would like to select a different folder dick Browse DK 5000 Mieruzzo Software QE LINE SEIKI 3 DK 5000 Series Mieruzzo Software User s Manual 1 1 6 Select whether to create or not to create a desktop icon for the software via the checkbox Click Next to continue with the software installation Bl Setup DK 5000 Mieruzzo Software Select Additional Tasks Which additional tasks should be performed Select the additional tasks you would like Setup to perform while installing DK 5000 Mieruzzo Software then dick Next Additional icons Create a desktop icon 1 1 7 Click Install to continue with the software installation io Setup DK 5000 Series DataLink Software Ready to Install Setup is now ready to begin installing DK 5000 Series DataLink Software on your computer Click Install to continue with the ins
9. 1 3 Export Record Number of Logs 170 Model DK 5005B Device ID 123 Records 5 3 4 2 A dialog will appear to confirm the requested command Cancel 3 4 3 Click OK to delete selected record The following message will appear to confirm that the Record was successfully deleted QE LINE SEIKI d DK 5000 Series Mieruzzo Software User s Manual 3 4 4 Delete Record will not proceed if the Records in the device do not match the Records on 3 5 3 5 1 display A dialog will appear to confirm if the display will be updated by an automatic Acquire All Records command d Cannot Delete Record There are changes to the device records Do you wish to update Select Yes to update display by acquiring all Records in the device memory Select No to abort Delete Record command CLEAR ALL DATA IN DK 5000 DEVICE Click Device in the menu bar select Device Settings and then select Clear All Data Device gt Device Settings gt Clear All Data 3 Device Settings t tf Clear All Data Ctrl L zr Connection Ctl O mi Set Device ID Ctrl I 7 p Disconnect Ctrl Shift C ir Sync Time Ctil T Firmware Version Cancel QE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 3 5 3 Click OK to clear all Records in the device 9 2 1 All the Records in the device will be deleted and the records displayed in the software will also be cleared Note The DK
10. 2014 11 30 08 12 39 6 8 2014 11 30 08 12 39 7 9 2014 11 30 08 12 39 8 10 2014 11 30 08 12 39 9 11 2014 11 3008 12 40 10 12 2014 11 30 08 12 40 11 13 2014 11 30 08 12 41 13 14 2014 11 30 08 12 41 14 15 2014 11 30 08 12 41 15 an 22 A nanan ae ArwwWwwwWWNNN FF OO CO Oo oo od od 4 UJ U U NM M o H O oO eO OU hJ hJ N NRF RP RP RP RR O N NM N N HP RP RP RP RP H H HH HB HB 8IN m Iloclololoiloiloeileioelele ie Tm d Start Time 2014 11 30 08 12 36 End Time 2014 11 30 08 13 11 gt Export Record Number of Logs 170 Model DK 5005B Device ID 123 Records 5 QE LINE SEIKI i DK 5000 Series Mieruzzo Software User s Manual 4 1 2 You can choose to save the record as an MS Excel Workbook XLS or a comma separated value CSV file Js Es k Libraries Documents Organize New folder E XY Favorites Documents library NE Desktop Includes 2 locations Downloads B A Arrange by Folder El Recent Pla H Recent Places PE Wc Libraries B D Eg Documents B E al Music Pictures BE Videos File name MAU a aT CALO ERO DOCU DR ES ma Separated Value csv Excel Workbook xl Hide Folders The default filename to be used follow the format below Device ID start timestamp end timestamp xls Device ID start timestamp end timestamp csv 4 2 EXPORT ALL RECORDS 4 2 1 To export all records displayed click File in the menu bar and then select Export A
11. 5000 device will proceed to Memory Recall Mode displaying no data to indicate that the memory is cleared of all data For Type B and Type C devices the Clear All Data feature cannot be used when device is in Recording or Count Mode respectively If Clear All Data is attempted during Recording or Count Mode an error message will be shown Device is in Recording Mode Cannot process your request Error Code 5 21 NE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual EXPORTING RECORDS TO A FILE 4 1 EXPORT A SPECIFIC RECORD This function enables saving a copy of selected Record to a spreadsheet This function is available in Type B and Type C DK 5000 devices only For Type A devices please use the Export All Records function 4 1 1 To export a specific individual Record right click on the page to be exported and then select Export Record or click the Export Record button which is found on the lower right corner of the page File Device Help Auto Acquire it Acquire All Records ij Export All Records 2014 11 30 08 13 11 2014 11 30 08 20 17 2014 11 30 08 20 40 2014 11 30 08 21 24 2014 11 30 08 21 39 Timestamp Total Input 1 Input 2 Input 3 Input 4 Input 5 4 IL Timestamp Total Input 1 Input 2 Input 3 Input 4 Input 5 i 1 eee 2 2014 Export Record 3 2014 11 30 08 12 39 2 4 2014 11 30 08 12 39 3 5 2014 11 30 08 12 39 4 6 2014 11 30 08 12 39 5 7
12. T A DK 5000 DEVICE When a DK 5000 device is physically connected to the computer via a USB cable click Device in the menu bar then select Connection Device gt Connection Device Settings Connection Ctrl O Disconnect Ctrl Shitt C Sync Time Ctrl T Firmware Version or click Connection button File Device Help f Acquire Present Data dj Acquire All Records Export All Records The drop down button will list all DK 5000 devices available with their corresponding Device ID and COM Port Connection If there are multiple items in the list select the device you want to connect Please select available DE 5000 device from the list K 5 105 5000 COMO DK 5005A 000 COMOL QE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 2 1 3 Click OK to connect to the selected DK 5000 device When the software successfully connects to the selected device the Title Bar will display the Device ID and COM Port Connection as shown below The device details will also be shown in the lower left corner which will show the device model Device ID and the number of Records available in the device memory DK 5000 Mieruzzo Software DK 5005A 000 COMO1 File Device Help ll Auto Acquire lf Acquire All Records Successful connection to a Type A or Type B device will show the Auto Acquire page File Device Help Auto Acquire j Acquire All Rec
13. e All Records File Device Help dE Acquire All Records Ctrl D Auto Acquire Ctrl G A Export All Records Ctrl K A bit Ctrl X Or click Acquire All Records button File Device Help Acquire Present Data Acquire All Records F Connection A Export All Records 3 3 2 A successful Acquire All Records command will show all the records saved in the memory of the DK 5000 device Additionally it will update the number of Records shown in the displayed device details 15 NE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual For a Type A device all Records are listed in a single table File Device Help Auto Acquire i Acquire All Records IA Export All Records Timestamp Total Counter Counter2 Counter3 Counter4 Counter 5 2014 11 30 08 02 04 75 1 6 2014 11 30 08 02 30 120 22 29 24 2014 11 30 08 44 43 114 20 19 26 2014 11 30 08 44 52 24 4 3 Model DK 5005A Device ID 000 Records 4 For Type B and Type C devices each Record is shown as a separate table Each table shows a list of all the logs inside that Record File Device Help Auto Acquire j Acquire All Records IA Export All Records 2014 11 30 08 13 11 2014 11 30 08 20 17 2014 11 30 08 20 40 2014 11 30 08 21 24 2014 11 30 08 21 39 Timestamp Total Input 1 Input 2 Input 3 Input 4 Input 5 2014 11 30 08 13 11 E SESE 170 mo aS aa l
14. e software installation If Launch DK 5000 Mieruzzo Software is checked the software will automatically launch if Setup DK 5000 Mieruzzo Software Completing the DK 5000 Mieruzzo Software Setup Wizard Setup has finished installing DK 5000 Mieruzzo Software on your computer The application may be launched by selecting the installed icons Click Finish to exit Setup Launch DK 5000 Mieruzzo Software NE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 1 1 11 See below image for the default view of the DK 5000 Mieruzzo Software 1 2 1 2 1 2 DK 5000 Mieruzzo Software File Device Help Auto Acquire Acquire All Records Export All Records DK 5000 DEVICE DRIVER The correct DK 5000 Device Driver is installed together with the DK 5000 Mieruzzo Software In case there is a need to re install the device driver it can be found by selecting the correct driver located in the installation directory of the software The following message will be shown upon successful installation or update of the device driver k Update Driver Software DK 5000 Series Tally Counter COM23 Windows has successtully updated your driver software Windows has finished installing the driver software for this device DK 5000 Series Tally Counter S LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual CONNECTING AND DISCONNECTING A DK 5000 DEVICE 2 1 2 1 1 CONNEC
15. ll Records File gt Export All Records Device Help Acquire All Records Ctrl D Auto Acquire Ctri G Export All Records Ctrl K Exit Ctri X QE LINE SEIKI 2 DK 5000 Series Mieruzzo Software User s Manual Or click Export All Records button File Device Help Acquire Present Data Uf Acquire All Records ig Connection Export All Records 4 2 2 You can choose to save the Records as an MS Excel Workbook XLS or a comma separated value CSV file 4 Save As COCA B k Libraries Documents Organize New folder a Fr Favorites r4 Documents library Desktop Includes 2 locations Downloads di A E Recent Places d B wc Arrange by Folder Libraries ES Documents al Music Pictures BE Videos The default filename to be used follow the format below Device ID date amp time of export xls Device ID date amp time of export csv If exported to Excel each Record will be on a different sheet in one Excel file while if exported in CSV each Record will be stored as individual CSV files QE LINE SEIKI i DK 5000 Series Mieruzzo Software User s Manual CHANGING DEVICE SETTINGS 5 1 SET DEVICE ID The software can be used to change the Device ID of the connected DK 5000 device The Device ID is a 3 digit user programmable number which is used to identify different DK 5000 devices 5 1 1 Click Device in the menu bar select Device Settings and then select Set De
16. n the menu bar and then select Disconnect Device Disconnect Device Settings Connection Ctri O Disconnect Ctrl Shift C Sync Time Ctrl T Firmware Version A message will appear to confirm disconnection The DK 5000 can now be physically disconnected from the computer PED safe to Remove Hardware Device can now be safely removed from your system Warning Do not physically disconnect the DK 5000 device from the computer without a Disconnect command and confirmation that the device can be safely removed This will introduce a huge risk of the software not being able to detect re connection of the DK 5000 device or new connections of new DK 5000 devices 11 NE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual DATA COMMUNICATION WITH DK 5000 DEVICE 3 1 AUTO ACQUIRE PRESENT DATA This function is available in Type A and Type B DK 5000 devices only Software will show the present data displayed on the DK 5000 device and will automatically refresh every 1 second 3 1 1 Click File in the menu bar and then select Auto Acquire File gt Auto Acquire Device Help dE Acquire All Records Ctrl D Auto Acquire Ctrl G A Export All Records Ctri K A bit Ctrl X Or click Auto Acquire button File Device Help Auto Acquire i Acquire All Records ig Connection ij Export All Records A successful Auto Acquire command will show the present data displayed
17. on the DK 5000 device and the display will be automatically updated every 1 second The Last Update Time of the display is also shown There are two display formats available Click the corresponding radio button to select the preferred display format 12 NE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual Format 1 shows the individual values of each Counters or Inputs on the left side and the total of all Counters or Inputs on the right side File Device Help J Auto Acquire E Acquire All Records l Export All Records Auto Acquire Format1 Format2 Last Update Time 2014 12 19 09 50 23 aes es ee Model DK 5005A Device ID 000 Records 4 Format 2 shows the value of Counter 1 or Input 1 on the left side total and individual values of other Counters or Inputs in the middle and total of all Counter or Inputs on the right side File Device Help Auto Acquire Acquire All Records ij Export All Records Auto Acquire Format1 Format 2 Last Update Time 2014 12 19 09 50 23 Model DK 5005B Device ID 101 Records 2 S LINE SEIKI B 3 2 3 2 1 3 2 2 DK 5000 Series Mieruzzo Software User s Manual ACQUIRE PRESENT DATA This function is available in Type C DK 5000 devices only Software will show the present data
18. ords IA Export All Records Auto Acquire Format1 Format 2 Last Update Time 2014 12 19 09 50 23 SS Model DK 5005A Device ID 000 Records 4 QE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual Successful connection to a Type C device will show the Acquire Present page File Device Help Acquire Present Data Ut Acquire All Records IA Export All Records Present Last Update Time 2014 12 19 09 50 23 a A EA Model DK 5005C Device ID 000 Records 0 2 1 4 f attempting to connect a new device while there are Records from a different device on display a dialog will appear to confirm if Records will be saved before connecting to the new device nd Connect New Device Your record will be cleared if you connect to a new device WU Do you wish to save before you proceed Select Yes to save the displayed Records oelect No to discard the Records on display and continue connecting to the new device Select Cancel to abort connection to the new device QE LINE SEIKI a 2 1 5 2 2 2 2 1 DK 5000 Series Mieruzzo Software User s Manual In cases where no DK 5000 device is detected an error message will be shown Unable to detect a DK 5000 device Please check device connection Error Code 30 DISCONNECT A DK 5000 DEVICE Click Device i
19. rding Mode Cannot process your request i Error Code 5 QE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual MISCELLANEOUS FUNCTIONS 6 1 VIEW DEVICE FIRMWARE VERSION 6 1 1 Click Device in the menu bar and then select Firmware Version Device gt Firmware Version It will show the firmware version of the connected device EET de ey Firmware Version DK 5000 firmware v 4 0 6 2 CHECK FOR SOFTWARE UPDATES 6 2 1 Click Help in the menu bar and then select Check for Updates Help gt Check for Updates lt will automatically search for available software updates Contacting Software Sites Details gt gt 27 NE LINE SEIKI 6 2 2 6 3 6 3 1 6 4 6 4 1 DK 5000 Series Mieruzzo Software User s Manual If there is no internet connection or if the software cannot connect to the update server an error message will appear Problem Occurred Contacting Software Sites has encountered a problem Unknewn Host http software line com ph dk5000 release repository content xml VIEW SOFTWARE INSTRUCTION MANUAL Click Help in the menu bar and then select Manual Help Manual It will open a copy of the DK 5000 Mieruzzo Software User s Manual VIEW SOFTWARE VERSION AND INSTALLATION DETAILS Click Help in the menu bar and then select About DK 5000 Mieruzzo Software Help About DK 5000 Mieruzzo Software It will show
20. tallation or cick Back if you want to review or change any settings Destination location C Program Files x86 DK 5000 Series DataLink Software Start Menu folder DK 5000 Series DataLink Software Additional tasks Additional icons Create a desktop icon WE LINE SEIKI i DK 5000 Series Mieruzzo Software User s Manual A progress bar will show the installation progress Setup DK 5000 Mieruzzo Software Installing C Mieruzzo DK 5000 Mieruzzo Software plugins com ibm icu_4 4 2 v20110823 jar s eee 1 1 8 DK 5000 Series Device Driver Updater will open for the installation of necessary device driver Click Next to continue DK 5000 Series Device Driver Updater Welcome to device installer This wizard will walk you through updating the drivers for your device To continue click Next S LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 1 1 9 The following window will appear upon successful installation of the DK 5000 Series Device Driver Click Finish to continue DK 5000 Series Device Driver Updater Congratulations You finished installing your DK 5000 device drivers The drivers were successfully installed on this computer You can now connect your device to this computer IF your device came with instructions please read them first Driver Name Status w Line Seiki Co Ltd www Ready to use 1 1 10 Click Finish to complete th
21. the following window which tells the software build version and an option to see the software installation details About DK 5000 Mieruzzo Software DK 5000 Mieruzzo Software v 10 9 e Build 773 Line Seiki Co Ltd c 2014 http www mieruzzo com DK5000 28 WE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 7 FREQUENTLY ASKED QUESTIONS 1 Why do get a no DK 5000 device detected message when click Connection even when my device is visibly connected These are common reasons for not detecting a DK 5000 device and possible solutions e Make sure your device is connected and turned ON You cannot connect if the device is turned off e Make sure that the PC recognizes your device If this is the first time you connected a DK 5000 device it ll take some time for windows to install the appropriate driver Please note that our software installation contains the drivers necessary for your DK 5000 e We received reports that changing the USB port to connect to help with the OS recognizing the device 2 Why do I get an unknown device error when I connect the DK 5000 device to my PC These are 2 possible reasons for unknown device error e Driver installation Make sure that you ve properly followed the software and driver installation e Windows USB Stack issue This is an issue with Windows USB stack Try disconnecting then reconnecting the device or restarting your PC 3
22. ves as a warning to backup data by exporting to an XLS or CSV file and free up device memory by deleting old Records When memory is full the device will automatically delete the oldest Record to free up memory when additional memory for new Records is needed Information Device memory is FULL 17 NE LINE SEIKI 3 3 4 3 4 3 4 1 DK 5000 Series Mieruzzo Software User s Manual If Acquire All Records is pressed while the Records in the device are already on display because of a prior Acquire All Records command the software will check if there are new Records or if there are changes in the device If the Records in the device do not match the Records on display a dialog will appear to confirm if Records will be saved before acquiring Records Update Record There are changes made in the device and you may lose some records if you update Do you wish to save before you proceed oelect Yes to save the displayed Records Follow the export procedure Select No to discard the Records on display and continue acquiring new Records oelect Cancel to abort acquiring all Records DELETE A SPECIFIC RECORD IN DK 5000 DEVICE To delete a specific record in a Type A device right click on the Record to be deleted and then select Delete Record File Device Help Auto Acquire i Acquire All Records 9 Connection IA Export All Records Auto Acquire Records
23. vice ID Device gt Device Settings gt Set Device ID Device Settings t H Clear All Data Ctrl L g Connection Ctri O a Set Device ID Ctrl I g Disconnect Ctrl Shift c gg Sync Time Ctrl T Firmware Version 5 1 2 Type the desired 3 digit Device ID Set Device ID Please enter the device ID 5 1 3 Click OK to save selected Device ID 5 1 4 For Type B and Type C devices this feature cannot be used when in Recording or Count Mode respectively If the Device ID is attempted to be changed during Recording or Count Mode an error message will be shown Device is in Recording Mode Cannot process your request Error Code 5 25 NE LINE SEIKI DK 5000 Series Mieruzzo Software User s Manual 5 2 SYNCHRONIZE DK 5000 DEVICE TIME WITH SYSTEM TIME 5 2 1 Click Device in the menu bar and then select Sync Time Device gt Sync Time Device Settings Connection Ctrl O Disconnect Ctrl Shift C Sync Time Ctrl T Firmware Version Time on device will be synced with time on computer 2014 12 19 09 56 04 5 2 3 Click OK to sync the time of DK 5000 device to system time 5 2 4 For Type B and Type C devices this feature cannot be used when in Recording or Count Mode respectively If time is attempted to be synced during Recording or Count Mode an error message will be shown Device is in Reco

Download Pdf Manuals

image

Related Search

Related Contents

University of Illinois at Urbana    Nobo Liquid Ink Drywipe Markers Assorted Blister (6)  Istruzioni d`uso e di montaggio Weishaupt Pompa di calore aria  「テレビ/モニターの転倒・落下防止対策」に関するお願い  JVC TH-A9R User's Manual  WACOM GRAPHIRE CTE-630BT User's Manual  Samsung SF-565P Manuel de l'utilisateur  FOXY CAR 1:10 Brushless  BENNING CFlex 1 - CONRAD Produktinfo.  