Home

SPDU-108L PDU Installation Manual

image

Contents

1. control the PDU through user friendly web interface The web interface uses AJAX for providing near real time update on power consumption for each outlet total power and many other parameters Before using web interface make sure you have the latest Java Runtime Environment on PC from where you access the PDU Ip _ gt echolasys1 ECHOLA Power Systems Host ECHOLASYS51 Control Monitor Device Info Setup Automation Reports Volt Hz 122 5 60 0 Copyright Echola Systems LLC All rights reserved To access GUI from any smart phone mobile devices just use letter m after the ipaddress or the hostname like http 192 168 2 21 m For more details on web interface please refer to User s Manual at http www echola com power Support html Echola Systems L L C amp E L g LA 1161 Ringwood Ct Ste 100 San Jose CA 95131 AAA ENEAN A Phone 408 321 9663 http www echola com power Automation You can either use Tcl scripting language refer to separate document for automation using Tcl or Perl for automation Here is an example how to use Perl script which uses api xml file from the PDU to parse certain outputs If you are on windows you can use strawberry perl HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH Command Syntax perl xmlget pl http lt ipaddress gt H HHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHHH use LWP UserAgent use XML Simple S
2. IPADDR shift create objects Sxml new XML Simple Sua LWP UserAgent gt new send request for api xml SREQUEST SIPADDR api xml Sreq HTTP Request gt new GET gt SREQUEST Sreq gt header Cookie gt test quest Sres Sua gt request Sreq Sdata Sxml gt XMLin Sres gt content print them print Outlet1 Power Sdata gt pow1 print Outlet2 Power Sdata gt pow2 print Outlet3 Power Sdata gt pow3 print Outlet4 Power Sdata gt pow4 print OutletS Power Sdata gt pow5 print Outlet6 Power Sdata gt pow6 print Outlet7 Power Sdata gt pow7 print Outlet8 Power Sdata gt pow8 print Voltage Frequency Sdata gt volt print Temperature Sdata gt temp Echola Systems L L C E C O LA 1161 Ringwood Ct Ste 100 San Jose CA 95131 autem Phone 408 321 9663 http www echola com power Troubleshooting If you get connection lost messages when you are on any GUI page telnet or snmp might still work you will have to make sure you are running latest version of JAVA on the PC where you run the browser to log into the smart PDU The older versions of java ver lt 5 or early 6 versions doesn t work well with the AJAX calls that we use for real time updates You can check whether you have latest java by clicking on following link http java com en download testjava jsp and do an update to avoid this intermittent problem Also check
3. Smart Switched PDU Installation Model SPDU 108L Important Safety Instruction There are no user serviceable parts inside Do not attempt to open any part of PDU Doing so may expose you to possible shock hazard and voids your product warranty The PDU does not provide short circuit protection Therefore Echola Systems does not recommend plugging the unit directly into any unprotected power source such as a wall outlet Always connect to an appropriately rated branch circuit s outlet which provides short circuit protection using standard Circuit Breakers or Fuses Always maintain reliable earthing of the PDU Do not connect the PDU to an ungrounded outlet or adapters or extension cords that doesn t have ground connection The power requirement of each equipment connected to the PDU s outlet should not exceed individual outlet s rated maximum capacity refer to specification of appropriate model for ratings The aggregate power requirements of equipment connected to all outlets at any time should not exceed the maximum input capacity of PDU refer to specification of appropriate model for ratings Install the PDU where it may be easily disconnected for service The PDU is designed for indoor use only Avoid exposing to extreme ambient temperatures g Echola Systems L L C a i g LA 1161 Ringwood Ct Ste 100 San Jose CA 95131 BHSsemsS Phone 408 321 9663 http www echola com power SPDU 108L Specific
4. ation aoe Input voltage range 100 120V AC eee 120V AC Output Output voltage Output receptacle type NEMA 5 15R ISA 12A Agency derated Note The aggregate current drawn by all outlets at any time can t exceed Max Input current Number of Outlets Outlet Current Monitoring Accuracy Operating Environment __ 2 113 F Operating Relative Humidity 095 Operating Elevation 0 10000 feet Maximum Output current outlet Physical Desktop WallMount Net weight 4 Ibs Dimensions Max HxWxD 2 x 14 5 x 4 inches Color White ABS plastic UL60950 1 USA CSA C22 2 No ge 1 1 2 E DE Certifications 60950 Canada 2nd dition E WE Information Technology Equipment Safety MET Listing ID E113398 g Echola Systems L L C E ik m g LA 1161 Ringwood Ct Ste 100 San Jose CA 95131 AAA ENEAN A Phone 408 321 9663 http www echola com power TaReleiiela The smart PDU has 8 outlets sockets numbered as shown above First connect the equipment you want to control amp monitor to these outlets sockets Connect network cable between a router hub amp the PDU and then connect input power cord to the power source Now you should be able see IP Address Hostname displayed on the LCD screen Proceed to next step the Network configuration Initial Network Configuration If your network has a DHCP server then you may want to skip this section a
5. er is always the previlaged user who can access any web page You can also create a different user who can access to main Control Monitor page but is not allowed to access Setup page This user is by default called guest but name can be changed using Setup gt User tab and default password is guest as well If the authentication fails Authentication Required message will be displayed The authentication can optionally be disabled for Control Monitor web page the home page on the main menu by using Setup gt User setting so that admin or guest user can access main page without login but the Setup web page will still require login User Interfaces Front Panel LCD LCD moving character display on the front panel displays following important information This is useful when you are near the device to setup or monitor 1 Hostname 2 IP Address 3 Outlet Status 4 Total Current Consumption in Amps The outlet status shows the status of all 8 outlets and it could be one of the following 1 o Empty circle means corresponding outlet is switched OFF 2 e Filled circle means corresponding outlet is switched ON 3 x Cross means corresponding outlet has been shut off due to overload Individual port overload protection feature Echola Systems L L C E ik O LA 1161 Ringwood Ct Ste 100 San Jose CA 95131 autem Phone 408 321 9663 http www echola com power Web Interface User can configure monitor and
6. for any malware anti virus firewall software which might block the http connection to PDU We don t support router behind router or router hacked to work in bridge mode configurations If you have such configuration you may want to connect the PDU to the primary router router that acts as gateway or dhcp server For any technical questions email to support echola com Echola Systems L L C E ik O LA 1161 Ringwood Ct Ste 100 San Jose CA 95131 Phone 408 321 9663 http www echola com power Systems
7. nd connect PDU Ethernet port to their network s switch router and the IP address will be assigned automatically by your DHCP server The assigned IP address will be shown on the LCD panel Use that IP to login into PDU and manage it If you don t have a DHCP server running on your network then you may want to configure Static IP there are three ways you could do this 1 Using NBNS NetBIOS Name Service of PDU 2 Using built in DHCP server of PDU 3 Using Static IP configuration of your PC Laptop Echola Systems L L C E C O LA 1161 Ringwood Ct Ste 100 San Jose CA 95131 Systeme Phone 408 321 9663 http www echola com power Using NBNS NetBIOS Name Service You would need a Windows based Laptop or a PC to configure PDU using this method for the first time You may also need a ethernet crossover cable to connect PDU to a PC ora Laptop but most of the modern PC Laptops would work with either type of cable straight or crossover Make sure the PC Laptop IP option Obtain IP address automatically is checked in the Internet Protcol Properties of the ethernet interface Now launch the internet browser and type http echolasys in the address bar and press Enter key Now you will be prompted with a PDU s login dialog If this is first time then use default username and password After login you will see the main menu page of the PDU Now click on the Setup tab of the menu to bring the Network Config menu From here you can as
8. sign static IP subnet mask and gateway and save your configuration Thats it now you are set to connect PDU to your network switch router and access it from remote e Default Username admin e Default Password admin Using built in DHCP server The procedure is same as above NBNS except that instead of using hostname echolasys in your browser you will have to use the IP address like http 192 168 2 222 displayed on the LCD panel This method works for non windows PC Laptop as well Using Static IP configuration Configure your PC Laptop ethernet port s IP address to match the network portion of default IP adress of PDU e Default IP Address of PDU 192 168 2 222 e Default Gateway of PDU 192 168 2 222 e Default Subnet mask of PDU 255 255 255 0 For example you can configure your PC Laptops IP address as 192 168 2 222 and access the main menu of PDU After configuring the PC Laptop ethernet address just use any internet browser to access PDU with new configure IP address Now you will be prompted with PDU s login dialog If this is first time then use default username and password Now the default network settings of IP subnet mask and gateway can be changed to match your network setting through Setup tab e Default Username admin e Default Password admin User Authentication Echola Systems L L C E CHOLA ferningwocd Co Sieni San Jose CA 95131 Systems Phone 408 321 9663 http www echola com power Admin us

Download Pdf Manuals

image

Related Search

Related Contents

CleanAll DNA/RNA Clean-Up and Concentration Micro Kit  Bedienungsanleitung Powador-piccoLOG_de  LCD2110TM    Télécharger l`article en PDF  Samsung WD0804W8E washer dryer  Combinés centrales de pêche à lecteur  静電容量式レベルメータ 可動部がないため  PROFESSIONAL DISHWASHER  Max 5 bar pump pressure Steam generator iron  

Copyright © All rights reserved.
Failed to retrieve file