Home
User Manual - J.P. Leisure
Contents
1. To access this mode plug the fixture in and put dipswitch 9 and 10 in the ON position The fixture will now chase through the colours To adjust the speed put the dipswitches 1 to 7 in the ON position 1 being the slowest 7 being the fastest To exit this mode put the dipswitches in the OFF position RGB mode To access this mode plug the fixture in and put dipswitch 8 9 and 10 in the ON position Dipswitch 1 placed in the ON position will project red at 25 intensity whilst dipswitch 2 will project at 50 intensity Combining both dipswitches 1 and 2 will project red at 100 intensity Dipswitch 3 placed in the ON position will project green at 25 intensity whilst dipswitch 4 will project at 50 intensity Combining both dipswitches 3 and 4 will project green at 100 intensity Dipswitch 5 placed in the ON position will project blue at 25 intensity whilst dipswitch 7 will project at 50 intensity Combining both dipswitches 5 and 6 will project blue at 100 intensity To exit this mode put the dipswitches in the OFF position www prolight co uk Party Par User Manual 5 EQUIN XX DMX setup Setting the DMX address The DMX mode enables the use of a universal DMX controller Each fixture requires a start address from 1 511 A fixture requiring one or more channels for control begins to read the data on the channel indicated by the start address For example a fix
2. Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recycling Business users should contact their supplier and check the terms and conditions of the purchase contract This product should not be mixed with other commercial wastes for disposal CE fe www prolight co uk Party Par User Manual 8
3. short circuit burns and electric shocks etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and or property www prolight co uk Party Par User Manual 2 EQUIN XX Party Par Product overview amp technical specifications Featuring 177 5mm RGB LEDs the Equinox Party Par outputs spots of colour that produce stunning shows for performances of all sizes The units operate in several modes including DMX and stand alone e 177 x 5mm LEDs R 60 G 61 B 56 e Beam angle 30 e DMX channels 6 e Auto sound active and RGB modes e 0 100 dimming e Captive power connection e 3 pin XLR in out socket e Fan cooled e Supplied with hanging bracket Specifications Party Par Power consumption 89W Power supply 120 240V 50 60Hz Dimensions 195 x 205 x 240mm Weight 1 1kg Order code EQLED81 195mm O 240mm 205mm E www prolight co uk DMX OUT DMX IN PARTY EOUINEX O www prolight co uk CER 100 240V 50 60Hz 01 Captive power connection 02 DMX out 03 DMX in 04 Status indicator 05 Dipswitches 06 Sound sensitivity adjustment knob In the box 1 x fixture 1 x power cable hanging bracket amp 1 x user manual Party Par User Manual 3 EQUIN KX Operating instructions DMX channel selection Operating in a DMX c
4. EQUIN XX Party Par User Manual Order code EQLEDO15 EQU fl KX Safety advice WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP e Before your initial start up please make sure that there is no damage caused during transportation e Should there be any damage consult your dealer and do not use the equipment e To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual e Please note that damages caused by user modifications to this equipment are not subject to warranty TAKE CARE USING KEEP THIS EQUIPMENT THIS EQUIPMENT AWAY FROM RAIN MOISTURE AND LIQUIDS HIGH VOLTAGE RISK OF ELECTRIC SHOCK IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other If the equipment is dropped or damaged disconnect the cables Handle the power cable and all mains voltage mains power supply immediately and have a qualified connections with particular caution engineer inspect the equipment before operating again e Never remove warning or informative labels from the unit If the equipment has been exposed to drastic Do not open the equipment and do not modify the unit temperature f
5. lities of erratic behaviour 3 pin Order ref CABL9O 5 pin Order ref CABL89 5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion F B A E 5 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR socket Pin 1 GND screen Pin 2 Signal Pin 3 Signal 5 pin XLR socket 3 pin XLR socket Pin 1 GND screen Pin 1 GND screen 8 Pin 2 Signal Pin 2 Signal Pin 3 Signal Pin 3 Signal Pin 4 N C Pin 5 N C www prolight co uk Party Par User Manual 7 EQUIN X WEEE notice Correct Disposal of this Product Waste Electrical amp Electronic Equipment Applicable in the European Union and other European countries SS with separate collection systems This marking shown on the product or its literature indicates that it should not be disposed of with other household wastes at the end of its working life To prevent possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources
6. luctuation e g after transportation do not connect power or switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors If your product fails to function correctly stop use e Do not expose to flammable sources liquids or gases immediately Pack the unit securely preferably in the e Always disconnect the power from the mains when original packing material and return it to your Pro Light equipment is not in use or before cleaning Only handle dealer for service the power cable by the plug Never pull out the plug by pulling the power cable Only use fuses of same type and rating Repairs servicing and power connection must only be e Make sure that the available voltage is between carried out by a qualified technician THIS UNIT CONTAINS 100 240V 50 60Hz NO USER SERVICEABLE PARTS e Make sure that the power cable is never crimped or WARRANTY One year from date of purchase damaged Check the equipment and the power cable periodically OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g
7. ontrol mode environment gives the user the greatest flexibility when it comes to customising or creating a show In this mode you will be able to control each individual trait of the fixture and each fixture independently To access the DMX channel mode plug in the fixture via the XLR connections to a DMX controller Set your desired DMX address following the set up specifications that come with your DMX controller 6 channel mode Value 1 0 255 Red 0 low brightness 255 high brightness 0 255 Green 0 low brightness 255 high brightness 3 i i a t O ps 0 255 ENR 0 7 8 255 s 0 15 16 255 0 31 32 63 96 127 Dimming 96 dim 112 bright 127 dim 128 159 160 191 192 223 224 255 Sound active sensitivity adjustment knob Channel 1 2 and 3 will not work when channel 4 is being used When the units are daisy chained together in DMX mode channel 1 2 and 3 must be OFF for units to sync together when using channel 4 When the value of channel 6 is between 32 and 127 you must be using either channel 1 2 or 3 or all three combined When using channel 6 channel 5 will control the speed of the colour changing www prolight co uk Party Par User Manual 4 EQUIN KX Operating instructions Sound active mode To access this mode plug the fixture in and put dipswitch 10 in the ON position The fixture will now react to sound To exit this mode put the dipswitch in the OFF position Auto mode
8. or DMX operation This fixture can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output see image below Further DMX cables can be purchased from all good sound and lighting suppliers or Pro Light Concepts dealers Please quote CABL10 2m CABL11 5m CABL12 10m Note DMX cable must be daisy chained and cannot be split www prolight co uk Party Par User Manual 6 EQUIN XX DMX setup Notice Be sure to follow the diagrams below when making your own cables Do not connect the cables shield conductor to the ground lug or allow the shield conductor to come in contact with the XLRs outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR e OO RAN SORES OMT RE OO XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Q Pin 2 Negative 3Hot 3Hot Pin 3 Postive Special note Line termination When longer runs of cable are used Termination reduces signal transmission you may need to use a terminator on problems and interference It is always the last unit to avoid erratic behaviour advisable to connect a DMX terminal resistance 120 Ohm 1 4 W between pin 2 Using a cable terminator will decrease DMX and pin 3 DMX of the last fixture the possibi
9. ture that occupies or uses 7 channels of DMX and was addressed to start on DMX channel 100 would read data from channels 100 101 102 103 104 105 and 106 Choose a start address so that the channels used do not overlap E g the next unit in the chain starts at 107 DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX linking DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA cable DMX cable requirements f