1. BLACK ARROW Information Technology 1lPage I Introduction This guide describes the features and the user instructions for X 1 Prospero Control Board Original Design Miner The X 1 Prospero Miner has inside one powerful MINION chip which can reach 100Ghash s hash rate 10 and has a very low power consumption X 1 is contains a Control Board and is very easy to control NO Parameter_ Value 1 I Hashing rate 100Ghash s 10 2 100Watts whole system 3 Power supply 110V 220V II Connecting your Prospero STEP 1 Plug the power cable into the power port STEP 2 Plug the Internet cable into the Ethernet port 2lPage III Web Configuration Obtaining the IP address The Prospero is shipped with DHCP enabled for an automatic IP address To set it manually you need an LCD model or first connect it to a network that supports DHCP LCD Model The IP address will be displayed on the screen Open a web browser to https lt ip address gt With or Without LCD Open a web browser to http prospero blackarrowsoftware com your browser must be on the same internal network for this to work your Prospero s should be listed Click to connect Login details default USER user PASSWORD blackarrow Network Control Panel ICH Bm m Disconnected Overview y E Dashboard Graphs Pools Dashboard E Prospero 110 4 gts basc 440095 102 168 0 00 i Actwe CONNECTE
2. address to 192 168 0 XXX where XXX is the desired static IP After the new IP address is setup user must press the SAVE button and the miner will restart automatically Pool Settings cgminer Cgminer Configuration stratum tcp uk1 ghash i0 3333 password stratum icp us 1 ghash i0 3333 worker1 password2 worker3 password3 Over Clock 1200Hz Click on the CGMINER button in the top right corner on the main page In the cgminer configuration input the pool address username and password The user has the choice to change the overclock selection as well There are four options 800Hz s 1000Hz s 1100Hz s and 1200Hz s After choosing the configuration click SAVE button in the top right corner to save the cgminer will restart User can Insert Pool Information as stated in the pool general information stratum tcp POOLADDRESS PORT This information can be copied from the pool s web page or How to FAQ section Note User can setup up 3 different pool addresses Once the setup is completed the pool address will be switched automatically if any of them is unreachable CANCEL situated in the top LEFT corner this button cancels the changes and brings the user to the main screen SAVE clicking this button will save any changes and will restart the miner NOTE User should allow some time for miner to restart and if it does not happen user should wait for few minutes longer If miner is still not runni
3. Alive http192 160 0 242 33434 ad basc00 4001b 192 763 043 Showing 1 to 1 of 1 entries Active CONNECTED Sync Network Want to use the same pool settings on all connected Prosperos Just click Sync Network and your configuration will be sent to all your devices IV LCD Status Configuration where fitted Login details default USER user PASSWORD blackarrow 4lPage 8 SPEED ANALYSIS CHART 9 TEMPERATURE STATUS ANALYSIS CHART TEMPERATURE STATUS ANALYSIS CHART Configuring parameters NETWORK setup button gives access to the network configuration window The button is positioned in the top left corner of the screen The user can configure here IP address net mask gateway and DNS default is 192 168 0 180 After changing the configuration user must click the SAVE button in the top right corner to save the configuration CGMINER button gives access to the CGMINER configuration window The button can be find in the right top corner of the screen SPEED this field registers the miner s average speed RUNNING STATUS Active BLUE confirms the miner is configured properly and is functioning to optimal status Stopped RED confirms the miner is in standby position and is not functioning properly Temperature registers the chip s average internal temperature NORMAL BLUE confirms the chip is performing OK and is running below the critical temperature HOT RED c
4. D Hash Watts Temp E Prosperoj110 7 gws 87 08 0 00 60 00 hand 147 162 040 Are I CONNECTED EF Prosperot ghs bestand 182 te ai Acne CORMEC TES 135 Ghs OW 3000 VW 0 C Prospero 171 0 gts baned344002n 192 168 0 87 ASICAD Status a Freq a Ghis Pr Zr ETE aabbesddeata O0 Alive 1200 87 08 1200 57 08 showing 1 to 1 of 1 entries 3lPage Overview If you have purchased multiple Prosperos and you gt Prospero 110 4 ghis have connected them all to the network your network baacl8440025 192 168 0 60 control panel will look something like this Active CONNECTED The first Prospero in the list is always the unit you that gt Prospero 110 7 ghs you are connected to Additional units you may have baac0844001b 192 166 043 are listed below There is no need to connect to all ALETA your other Prosperos individually MW 2 Prospero o ghs napa pe You can control everything from here The selected Active CONNECTED Prospero highlighted in yellow is the device that you are controlling y EP Prospero 121 0 gws baac08440023 192 168 0 57 Actve CONNECTED Setting up the Pool The first thing you will want to do is add a pool Select a Prospero Select the Pool tab and Add Pool Overview Dashboard Graohs Pools Add Pool Fallower Load Balance Aclive CONNECTED Status ae UR O OOo Le syne Network Prospero 110 4 ghs hasec0R440025 162 162 0 80 Prospero 110 7 ghisi
5. ng plug out the power cord wait for minimum 15 seconds then plug it back in OVER CLOCKING User can use this option to overclock or under clock the chip Please note that a stable performance is not guaranteed at any other frequency above the default 1000Hz User can select a frequency from the drop down menu To save the change the SAVE button should be clicked on IMPORTANT Please note that any custom overclocking disassembling the device replacing default parts with custom ones can damage or prevent the device from working Do not remove power supply from miner when power is on Make sure that device is shut down completely before removing power supply Do not apply excessive force when inserting power supply in to device Please avoid water from entering any part of the device If water has been spilled on the device turn it off immediately and dry it well with hair drier let it dry for a few days before attempting to power the device on Please do not insert any items in the airflow openings on the case doing so may cause device to stop working and a short circuit which will disable the device and void the warranty Avoid touching working miner or any of the parts such as power supply without proper antistatic protection Gloves bracelet Note that mechanical damage disassembling the device any customization or modifications will void the device s warranty Miner s default position and airflow Note that device i
6. onfirms the chip is overheating and running above the normal temperature Pool Status there are 3 pools listed automatically ON Pools are available OFF Pools are currently unreachable or pools addresses have not been set properly Page 7 Chip Status can list any number between 1 and 99 BLUE Chip is OK and is running RED Chip on the standby or is overheated or other the existence of other issues are preventing the chip from starting up properly 8 SPEED ANALYSIS CHART A chart is automatically displayed to capture the miner s average speed 9 TEMPERATURE STATUS ANALYSIS CHART A chart is automatically displayed to capture the miner s average temperature To change assigned static IP for your device the user must click on the NETWORK button situated in the top left corner of the miner status screen BlackArrow CGMINER Speed Running Status 126 4 9 0d 0h 48m A zz Active Temperature C Pool Status 0 S On Chip Status SPEED ANALYSIS CHART The user should be able to access the network configuration window The user can the miner s network details according to current network setup 6lPage Network Configuration 192 168 0 181 neimask 255 255 255 0 gateway 192 168 0 1 192 168 0 1 Please note that if the network default IP mask is different from static IP set on the miner therefore user will need to change its router or computer s IP
7. s designed to be placed on the side vertically Blocking the airflow vents may cause device to overheat and prevent it from working properly 8lPage Network security If your running on an untrusted Local Area Network e g public places shared accommodation unsecured network open WiFi etc your Prospero as default is not secure Steps are need to be taken such as changing root passwords and software settings to lock it down Check the online help or contact support for help Note that the web interface is secure by design and you can open it up to outside access on port 443 9lPage