1. Correctly set load monitor if installed Low hot water temperature or a lack of hot water This part of the fault tracing chapter only applies if the water heater is in stalled in the system Closed or choked filling valve for the hot water heater Open the valve Mixing valve if there is one installed set too low Adjust the mixer valve Control module in incorrect operating mode a If mode manual is selected select addition Large hot water consumption m Wait until the hot water has heated up Temporarily increased hot water capacity temporary lux can be activated in menu 2 1 Too low hot water setting m Enter menu 2 2 and select a higher comfort mode Too low or no operating prioritisation of hot water Enter menu 4 9 1 and increase the time for when hot water is to be prioritised Low room temperature Closed thermostats in several rooms Set the thermostats to max in as many rooms as possible Adjust the room temperature via menu 1 1 instead of choking the thermostats Chapter 4 Control module in incorrect operating mode Enter menu 4 2 If mode auto is selected select a higher value on stop heating in menu 4 9 2 If mode manual is selected select heating If this is not enough select addition Too low set value on the automatic heating control m Enter menu 1 1 temperature and adjust the offset of the heating curve If the room temperature is only low
2. NOTE Too high a set value for factor system can depending on your climate system produce an unstable room temperature If several climate systems are installed the above settings can be made for the relevant systems Own curve supply temperature Setting range 0 80 C flow line temp at 30 C flow line temp at 20 C flow line temp at 10 C flow line temp at 0 C flow line temp at 10 C flow line temp at 20 C You can create your own heating curve here if there are special require ments by setting the desired supply temperatures for different outdoor temperatures Caution Curve 0 in menu 1 9 1 must be selected for this curve to apply point offset outdoor temp point Setting range 40 30 C Default value 0 C outdoor temp point change in curve change in curve Setting range 10 10 C Default value 0 C flow temperature C outdoor temp C Chapter 3 Select a change in the heating curve at a certain outdoor temperature here One step is usually enough to change the room temperature by one degree but in some cases several steps may be required The heat curve is affected at 5 C from set outdoor temp point It is important that the correct heating curve is selected so that the room temperature is experienced as even TIP If it is cold in the house at for example 2 C outdoor temp point is set to 2 and change in curve is i
3. activated N stop temperature start temp e Setting range 5 0 80 0 C stop temperature EK Default value 24 0 C 365 SS e Select whether the pool control is to be activated within what temperat ures start and stop temperature pool heating must occur and how many compressors may work against the pool at the same time When the pool temperature drops below the set start temperature and there is no hot water or heating requirement SMO 40 starts pool heating Untick activated to switch off the pool heating CP Caution The start temperature cannot be set to a value that is higher than the stop temperature Menu internet 4 1 3 Here you make settings for connecting BEES SMO 40 to the internet A NOTE For these functions to work the net work cable must be connected nibe uplink aN tcp ip settings proxy settings Chapter 3 41 Menu Ao Menu 4 1 3 8 42 nibe uplink Here you can manage the installa SO tion s connection to NIBE Uplink http www nibeuplink com and see the number of users connected to the installation via the internet number OT serial number 13450012345678 connection string A connected user has a user account ET Eu in NIBE Uplink which have been given permission to control and or monitor your installation switch off all users Request new connection string To connect a user account on NIBE Uplink to your installation you must request
4. ation in menu 3 1 that you should note These two symbols indicate whether the compressor in the outdoor unit or additional heat in the installation is blocked via SMO 40 These can for example be blocked depending on which op erating mode is selected in menu 4 2 if blocking is scheduled in menu 4 9 5 or if an alarm has occurred that blocks one of them VI Blocking the compressor SS Blocking additional heat This symbol appears if lux mode for the hot water is activated This symbol indicates whether SMO 40 has contact with NIBE Uplink This symbol indicates whether solar heating is active Accessory needed This symbol indicates whether holiday setting is activated in menu 4 7 Chapter 2 The control module the heart of the house NIBE SMO 40 13 14 Menu number marked sub menu Name and menu number main menu Symbol main menu INDOOR CLIMATE HOT WATER INDOOR CLIMATE 1 temperature scheduling advanced MY SYSTEM Marked main menu Symbols sub menus Name sub menus Status information sub menus Operation To move the cursor turn the control knob to the left or the right The marked position is brighter and or has a turned up tab Selecting menu To advance in the menu system select a main menu by marking it and then pressing the OK button A new window then opens with sub menus Select one of the sub menus by marking it and then pressi
5. NIBE User manual NIBE SMO 40 Control module UHB GB 1345 1 231761 Navigation 5 e Ok button confirm select Back button back undo exit Control knob move increase reduce A detailed explanation of the button functions can be found on page 10 How to scroll through menus and make different settings is described on page 14 Set the indoor climate The mode for setting the indoor temperature is reached when in the start mode in the main menu by pressing the OK button twice Read more about the settings on page 21 Increase hot water volume 1 x INDOOR CLIMATE HOT WATER e 6 Ke e e L e To temporarily increase the amount of hot water if a hot water heater is installed to your SMO 40 first turn the control knob to mark menu 2 water droplet and then press the OK button twice Read more about the settings on page 32 In event of disturbances in comfort If a disturbance in comfort of any type occurs there are some measures that can be taken before you need to contact your installer See page 56 for instructions Table of Contents 1 Uu Important information Installation data Safety information Serial number Contact information SMO 40 An excellent choice The control module the heart of the house Control module s function Contact with SMO 40 Maintenance of SMO 40 SMO 40 at your service Set the indoor climate Set the
6. 14 days Setting range 00 00 23 00 start time 0200 Default value 00 00 Next periodic increase 20 To prevent bacterial growth in the water heater the heat pump and any additional heat can increase the hot water temperature for a short time at regular intervals The length of time between increases can be selected here The time can be set between 1 and 90 days Factory setting is 14 days Untick activated to switch off the function Chapter 3 35 Menu 2 92 36 hot water recirc accessory required operating time Setting range 1 60 min Default value 60 min downtime Setting range 0 60 min Default value O min operating time min downtime 12 fmin period 1 OD DF UJEL period 2 period 3 Set the hot water circulation for up to three periods per day here During the set periods the hot water circulation pump will run according to the settings above operating time decide how long the hot water circulation pump must run per operating instance downtime decide how long the hot water circulation pump must be stationary between operating instances Chapter 3 Menu 5 1 Get information Overview Sub menus For the menu Ngee there are several sub menus No settings can be made in these menus they just display in formation Status information for the relevant menu can be found on the display to the right of the menus shows temperature levels and settings in the i
7. 3 45 d d Menu 4 3 46 Operating mode manual In this operating mode you can select what functions are permitted You cannot deselect compressor in manual mode Operating mode add heat only In this operating mode the compressor is not active and only additional heating is used Caution If you choose mode add heat only the compressor is deselected and there is a higher operating cost Caution You cannot change from only additional heat if you do not have a heat pump connected see menu 5 2 2 Functions compressor is that which produces heating and hot water for the ac commodation If compressor is deselected a symbol is displayed in the main menu on the symbol for the control module You cannot deselect compressor in manual mode addition is what helps the compressor to heat the accommodation and or the hot water when it cannot manage the whole requirement alone heating means that you get heat in the accommodation You can deselect the function when you do not wish to have heating running my icons You can select what icon should be dees visible when the door to SMO 40 is closed You can select up to 3 icons If you select more the ones you selected first will disappear The icons are dis played in the order you selected them WELL cc b i outdoor indoor temperature DN hot water temperature _ analog clock Chapter 3 Menu 4 6 Menu 4 7 time amp date
8. Set time and date display mode and time amp date4 4 time zone here Mn ime 2 2 Ti 09 IH 04 4 24 hrs TIP Ge Time and date are set automatically CYMREIG if the heat pump is connected to NIBE 06 month Uplink To obtain the correct time B year E Stockholm the time zone must be set language Choose the language that you want language 4 6 the information to be displayed in here holiday setting To reduce energy consumption during SSES a holiday you can schedule a reduc tion in heating and hot water temper WW WYF ature Pool and solar panel cooling start date Ol Ol E 8 can also be scheduled if the functions 8 Ol Ol 2010 are connected heating 0 hot water comfort economy If a room sensor is installed and activ E a ated the desired room temperature C is set during the time period This setting applies to all climate systems with room sensors If a room sensor is not activated the desired offset of the heating curve is set This setting applies to all climate systems without room sensors One step is usually enough to change the room temperature by one degree but in some cases several steps may be reguired Vacation scheduling starts at 00 00 on the start date and stops at 23 59 on the stop date Chapter 3 47 Menu 4 9 48 TIP Complete holiday setting about a day before your return so that room temperature and hot water have time to r
9. change page in multiple page instructions for example help text and service info Switch The switch assumes three positions On I Standby Emergency mode AN Emergency mode must only be used in the event of a fault on the control module In this mode the compressor in the heat pump switches off and the immersion heater engages The control module display is not illuminated and the status lamp illuminates yellow Chapter 2 11 Menu 1 Menu 2 Menu 3 Menu 4 12 Menu system When the door to the control module is opened the menu system s four main menus are shown in the display as well as certain basic information Outdoor temperature Indoor temperature if room sensors are installed HOT WATER Hot water temp Information about operation MY SYSTEM Temporary lux if Estimated amount of activated hot water INDOOR CLIMATE Setting and scheduling the indoor climate See page 21 HOT WATER Setting and scheduling hot water production See page 32 This menu only appears if a water heater is installed in the system INFO Display of temperature and other operating information and access to the alarm log See page 37 MY SYSTEM Setting time date language display operating mode etc See page 40 Chapter 2 Symbols in the display The following symbols can appear in the display during operation Description This symbol appears by the information sign if there is inform
10. change the room temperature by one degree but in some cases several steps may be re quired Activated Schedule System TEDULING HEATING 1 3 1 schedule 2 schedule 3 system 21 30 06 00 20 5 Conflict Day Time period Adjusting Schedule The schedule to be changed is selected here Activated Scheduling for the selected period is activated here Set times are not affected at deactivation System Which climate system the schedule is for is selected here This alternative is only displayed if more than one climate system is present Chapter 3 23 ei Menu 1 9 24 Day Select which day or days of the week the schedule is to apply to here To remove the scheduling for a particular day the time for that day must be reset by setting the start time to the same as the stop time If the line all is used all days in the period are set for these times Time period The start and stop time for the selected day for scheduling are selected here Adjusting How much the heating curve is to be offset in relation to menu 1 1 during scheduling is set here If the rooms sensor is installed the desired room temperature is set in C Conflict H two settings conflict with each other a red exclamation mark is displayed TIP If you wish to set similar scheduling for every day of the week start by filling in all and then changing the desired days TIP Set the stop time earlier than the start time
11. changes at different outdoor temperatures here Supply temperature Curve coefficient C Steeper curve slope _ The slope of the heating curve indic Kg ates how many degrees the supply temperature is to be increased re duced when the outdoor temperat ure drops increases A steeper slope means a higher supply temperature at a certain outdoor temperature 10 0 10 20 30 40 C Outdoor temperature The optimum slope depends on the climate conditions in your location if the house has radiators or under floor heating and how well insulated the house is The heating curve is set when the heating installation is installed but may need adjusting later Thereafter the heating curve should not need further adjustment Chapter 3 25 26 Caution In the event of making fine adjustments for the indoor temperature the heat curve must be offset up or down instead this is done in menu 1 1 temperature Supply temperature Curve offset C 70 Offset heating curve An offset of the heating curve al means that the supply temperature changes as much for all the outdoor temperatures e g that a curve off set of 2 steps increases the supply temperature by 5 C at all outdoor temperatures 10 0 10 20 30 40 C Outdoor temperature Supply temperature Flow line temperature maxim C P a um and minimum values Because the flow line temperature Maximum value cannot be calculated higher
12. hot water capacity Get information Adjust the heat pump Disturbances in comfort Manage alarm Troubleshooting Additional heating only Technical data Glossary Item register Table of Contents o o O oo ou N NN m o uw UI SS Do N Q d 1 Important information Installation data Product Serial number Installation date Installer Type of docking Accumulator hot water heater Heat pump output size Add heat type power fault set tings heating curve offset curve slope oni oo Serial number must always be given Certification that the installation is carried out according to instructions in NIBE s installer manual and applicable regulations Date Signed Chapter 1 Important information NIBE SMO 40 gt be Safety information This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a sate way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Rights to make any design or technical modifications are reserved ONIBE 2013 NOTE SMO 40 must be installed via an isolator switch with a minimum breakin
13. in cold weather the curve slope in menu 1 9 1 heating curve needs adjusting up Too low or no operating prioritisation of heat m Enter menu 4 9 1 and increase the time for when heating is to be pri oritised Holiday mode activated in menu 4 7 m Enter menu 4 7 and select Off External switch for changing the room heating activated m Check any external switches Air in the climate system Vent the climate system Closed valves to the climate system Open the valves contact your installer for assistance in finding them High room temperature Too high set value on the automatic heating control Enter menu 1 1 temperature and adjust the heat curve offset downwards If the room temperature is only high in cold weather the curve slope in menu 1 9 1 heating curve needs to be adjusted down External switch for changing the room heating activated m Check any external switches Low system pressure Not enough water in the climate system Top up the water in the climate system The compressor does not start There is no heating requirement The heat pump does not call on heating nor hot water Temperature conditions tripped m Wait until the temperature condition has been reset Minimum time between compressor starts has not been reached Wait 30 minutes and check if the compressor has started Alarm tripped Chapter 4 57 d 58 Follow the display instructions Ad
14. so that the period extends beyond midnight Scheduling then stops at the set stop time the day after Scheduling always starts on the date that the start time is set for Caution Changes of temperature in accommodation take time For example short time periods in combination with underfloor heating will not give a no ticeable difference in room temperature advanced Menu has orange text and is intended for the advanced user This menu has several sub menus eic ia each Setting the heating curve slope Setting the heat curve Offset when the external contact is connected ae Aa Setting minim um permitted flow line temperature Settings regarding the room sensor Setting own heat curve Chapter 3 Menu 1 9 1 eol Setting the offset of the heating curve at a specific outdoor temperature heating curve heating curve Settingrange 0 15 system W 2 3 4 Default value 9 flow temperature C ON 41 In the menu the presecribed heating curve for your house can be viewed Ihe task of the heating curve is to give an even indoor temperature regardless of the outdoor temperature and thereby energy efficient operation It is from this heating curve that the control modules control computer determines the temperature of the water to the heating system supply temperature and therefore the indoor temperature You can select heating curve and read off how the supply temperature
15. water one showers in for example DUT dimensioned outdoor temperature The dimensioned outdoor temperature differs depending on where you live The lower the dimensioned outdoor temperature the lower the value should be selected on selecting a heat curve Efficiency A measurement of how effective the heat pump is The higher the value is the better it is Electrical addition This is electricity that for example an immersion heater uses as addition during the coldest days of the year to cover the heating demand that the heat pump cannot manage Filtering time Enter the time the average outdoor temperature is calculated on Flow pipe The line in which the heated water is transported from the heat pump out to the house heating system radiators heating coils Heat exchanger Device that transfers heat energy from one medium to another without mixing mediums Examples of different heat exchangers are evaporators and condensers Heat factor Measurement of how much heat energy the heat pump gives off in relation to the electric energy it needs to operate Another term for this is COP Heating curve The heating curve determines which heat the heat pump is to produce depending on the temperature outdoors If a high value is selected this tells the heat pump that it must produce a lot of heat when it is cold out doors in order to achieve a warm indoor temperature Chapter 6 61 62 Heating medium Hot liquid usuall
16. The new value is shown on the right hand side of the symbol in the display Caution An increase in the room temperature can be slowed by the thermostats tor the radiators or under floor heating Therefore open the thermostats Tully except in those rooms where a cooler temperature is required e g bedrooms TIP Wait 24 hours before making anew setting so that the room temperature has time to stabilise If it is cold outdoors and the room temperature is too low increase the curve slope in menu 1 9 1 by one increment If it is cold outdoors and the room temperature is too high lower the curve slope menu 1 9 1 by one increment If it is warm outdoors and the room temperature is too low increase the value in menu 1 1 by one increment If it is warm outdoors and the room temperature is too high reduce the value in menu 1 1 by one increment Chapter 3 Menu 1 3 Menu scheduling In the menu SH indoor cli scheduling1 3 mate heating is scheduled for each weekday You can also schedule a longer period during a selected period vacation in menu 4 7 heal heating Increases or decreases in the accommodation temperature can be sched uled here for up to three time periods per day If aroom sensor is installed and activated the desired room temperature C is set during the time period Without an activated room sensor the desired change is set of setting in menu 1 1 One step is usually enough to
17. a unique connection string 1 Mark request new connection string and press the OK button 2 The installation now communicates with NIBE Uplink to create a connection string 3 When a connection string has been received it is shown in this menu at connection string and is valid for 60 minutes Disconnect all users 1 Mark switch off all users and press the OK button 2 Theinstallation now communicates with NIBE Uplink to release your installation from all connected users via the internet NOTE After disconnecting all users none of them can monitor or control your installation via NIBE Uplink without requesting a new connection string tcp ip settings You can set TCP IP settings for your EES installation here Automatic setting DHCP a g 1 Tick automatic The installation Mmm 0000 now receives the TCP IP settings REDER 0000 using DHCP dns 20867222222 2 Mark confirm and press the OK button confirm reset 4 Manual setting 1 Untick automatic you now have access to several setting options 2 Mark ip address and press the OK button Chapter 3 o Menu 4 1 3 9 3 Enter the correct details via the virtual keypad 4 Mark OK and press the OK button 5 Repeat 1 3 for net mask gateway and dns 6 Mark confirm and press the OK button Caution The installation cannot connect to the internet without the correct TCP IP settings If unsure abou
18. action Here you can read what the alarm means and receive tips on what you can do to correct the problem that caused the alarm reset alarm In most cases it is enough to select reset alarm to correct the problem that caused the alarm If a green lightilluminates after select ing reset alarm the alarm has been remedied If a red light is still visible and a menu called alarm is visible in the display the problem that caused the alarm remains If the alarm disappears and then returns contact your installer aid mode aid mode is a type of emergency mode This means that the installation produces heat and or hot water despite there being some kind of problem This can mean that the heat pump s compressor is not running In this case any electrical addition produces heat and or hot water Caution Selecting aid mode is notthe same as correcting the problem that caused the alarm The status lamp will therefore continue to be red Chapter 4 55 56 If the alarm does not reset contact your installer for suitable remedial ac tion NOTE Always communicate the product s serial number 14 digits when report ing a fault Troubleshooting If the operational interference is not shown in the display the following tips can be used Basic actions Start by checking the following possible fault sources The switch s position Group and main fuses of the accommodation The property s earth circuit breaker
19. ated Schedule EDULING HOT WATER 2 3 schedule 2 b i activated all Conflict Day Time period Adjusting Schedule The schedule to be changed is selected here Activated Scheduling for the selected period is activated here Set times are not affected at deactivation Day Select which day or days of the week the schedule is to apply to here To remove the scheduling for a particular day the time for that day must be reset by setting the start time to the same as the stop time If the line all is used all days in the period are set for these times Time period The start and stop time for the selected day for scheduling are selected here Adjusting Set the hot water comfort that is to apply during scheduling here Conflict If tvvo settings conflict with each other a red exclamation mark is displayed TIP If you wish to set similar scheduling for every day of the week start by filling in all and then changing the desired days TIP Set the stop time earlier than the start time so that the period extends beyond midnight Scheduling then stops at the set stop time the day after Scheduling always starts on the date that the start time is set for Chapter 3 Mera advanced 2 9 Menu has orange text and is intended for the advanced user This menu has several sub menus Menu periodic increases 2 9 1 period Setting range 1 90 days Default value 14 days activat 6 start time period
20. ault values here Do you want to reset all user settings to Caution factory settings After factory setting personal set tings such as heating curves must be reset schedule blocking The additional heat can be scheduled to be blocked for up to two different time periods here When scheduling is active the relevant blocking symbol is shown in the main menu on the symbol for the control module Activated Schedule chedule 1 schedule 2 gj activated all mon tues we thur on 1680 fri sat sun Conflict Day Time period Blocking Schedule The period to be changed is selected here Activated Scheduling for the selected period is activated here Set times are not affected at deactivation Day Select which day or days of the week the schedule is to apply to here To remove the scheduling for a particular day the time for that day must be reset by setting the start time to the same as the stop time If the line all is used all days in the period are set for these times Time period The start and stop time for the selected day for scheduling are selected here Chapter 3 51 ei Menu 4 9 6 52 Blocking The desired blocking is selected here Conflict H two settings conflict with each other a red exclamation mark is displayed EH Blocking the compressor in the outdoor unit EA Blocking additional heat TIP If you wish to set similar scheduling for every day of the
21. ay Washing machine Operation 1 time day 2000 Engine block heater Operation 1 h day 4 400 months a year Passenger compartment heater Operation 800 1 h day 4 months a year These values are approximate example values Example A family with 2 children live in a house with 1 flat screen TV 1 digital box 1 DVD player 1 TV games console 2 computers 3 stereos 2 bulbs in the WC 2 bulbs in the bathroom 4 bulbs in the kitchen 3 bulbs outside a washing machine tumble drier fridge freezer oven vacuum cleaner engine block heater 6240 kWh domestic electricity year Energy meter Check the accommodation s energy meter regularly preferably once a month This will indicate any changes in power consumption Chapter 2 The control module the heart of the house NIBE SMO 40 Menu e SMO 40 at your service Set the indoor climate Overview Sub menus For the menu INDO 0 Sem VN 4 there are several sub menus Status information for the relevant menu can be found on the display to the right of the menus Setting the temperature geff or the climate system The status in advanced formation shows the set values for the climate system rome Scheduling heating tatus Information set is displayed if you set a schedule but it is not active at the moment holiday setting is displayed if the vacation schedule is active at the same time as the schedule the vacation function is pr
22. curve and out to the left to read off the value for the supply temperature at the selected outdoor temperature You can now select to take read outs for different outdoor temperat ures by turning the control knob to the right or left and read off the corresponding flow temperature Press the OK or Back button to exit read off mode Chapter 3 27 Menu 1 9 2 28 TIP Wait 24 hours before making a new setting so that the room temperature has time to stabilise If it is cold outdoors and the room temperature is too low increase the curve slope by one increment If it is cold outdoors and the room temperature is too high lower the curve slope by one increment If it is warm outdoors and the room temperature is too low increase the curve offset by one increment If it is warm outdoors and the room temperature is too high lower the curve offset by one increment external adjustment climate system Setting range 10 to 10 or desired room temperature if the room sensor is installed climate system 1 Default value 0 climate system 2 climate system 3 climate system 4 Connecting an external contact for example a room thermostat or a timer allows you to temporarily or periodically raise or lower the room temper ature When the contact is on the heat curve offset is changed by the number of steps selected in the menu If a room sensor is installed and activated the desired room temperature C is
23. d on page 55 Display unit A Display B Status lamp C OK button D Back button Control knob Switch There is a display unit behind the control module door which is used to communicate with SMO 40 Here you switch on switch off or set the installation to emergency mode set the indoor climate and hot water as well as adjust the installation to your needs receive information about settings status and events see different types of alarms and receive instructions about how they are to be rectified A Display Instructions settings and operational information are shown on the display The easy to read display and menu system facilitates navigation between the different menus and options to set the comfort or obtain the information you require B Status lamp The status lamp indicates the status of the control module It lights green during normal operation lights yellow in emergency mode lights red in the event of a deployed alarm 10 Chapter 2 OK button The OK button is used to confirm selections of sub menus options set values page in the start guide Back button The back button is used to go back to the previous menu change a setting that has not been confirmed Control knob The control knob can be turned to the right or left You can scroll in menus and between options increase and decrease the values
24. d stop of additional heat and heat production is permitted dependent on the average outdoor temperature Select the average outdoor temperatures in this menu You can also set the time over which filtering time the average temper ature is calculated If you select 0 the present outdoor temperature is used Chapter 3 49 CP Caution It cannot be set stop additional heat higher than stop heating Menu degree minute setting 4 9 3 current value Setting range 3000 3000 start compressor current Ml 100 Dm Setting range 1000 30 start compressor 60 DM Default value 60 step difference compressors 60 DM start diff additional heat f 400 DM step difference compressors Setting range 10 2000 Default value 60 diff between additional steps 100 DM start diff additional heat Setting range 100 1000 Default value 400 diff between additional steps Setting range 0 1000 Default value 30 Degree minutes are a measurement of the current heating reguirement in the house and determine when the compressor respectively additional heat will start stop CP Caution Higher value on start compressor gives more compressor starts which increases wear in the compressor Too low value can give uneven indoor temperatures 50 Chapter 3 Menu 4 9 4 Menu 49 5 factory setting user All settings that are available to the user including advanced menus can be reset to def
25. ditional heating only If you are unsuccessful in rectifying the fault and are unable to heat the house you can whilst waiting for assistance continue running the heat pump in add heat only This means that additional heating only is used to heat the house Set the installation to additional heat mode 1 Go to menu 4 2 op mode 2 Mark add heat only using the control knob and then press the OK button 3 Return to the main menus by pressing the Back button NOTE If a heat pump is not connected by pipes to the system the flow must be shut off the pipe ends connected to each other where the heat pump should have been installed Caution When commissioning without NIBE air water heat pump an alarm com munication error may appear in the display The alarm is reset if the relevant heat pump is deactivated in menu 5 2 2 installed slaves Chapter 4 5 Technical datz Detailed technical specifications for this product can be found in the in stallation manual www nibe eu Chapter 5 59 60 Glossary Additional heat The additional heat is the heat produced in addition to the heat supplied by the compressor in your heat pump Additional heaters can be for ex ample immersion heater electric heater solar power system gas oil pellet wood burner or district heating Calculated flow line temperature The temperature that the heat pump calculates that the heating system requires for an opti
26. dy the hot water is set to luxury immersion heater permitted affect pool temperature accessories required Here you set whether pool temperature should be affected when activating SG Ready With low price mode of SG Ready the desired pool temperature start and stop temperature is increased by 1 C With over capacity mode of SG Ready the desired pool temperature start and stop temperature is increased by 2 C NOTE The function must be connected and activated in your SMO 40 op mode op mode op mode 4 2 i Setting range auto manual add heat only Default value auto auto _ manual functions i add heat onl Setting range compressor addi _ add heat only tion heating The control module operating mode is usually set to auto It is also pos sible to set the control module to add heat only when only additional heat is used or manual and then select what functions are to be permit ted Change the operating mode by marking the desired mode and pressing the OK button When an operating mode is selected it shows whatin the control module is permitted crossed out not permitted and selectable alternatives to the right To select selectable functions that are permitted or not you mark the function using the control knob and press the OK button Operating mode auto In this operating mode the control module automatically selects what functions are permitted Chapter
27. e 55 Saving tips Your heat pump installation produces heat and hot water This occurs via the control settings you made Factors that affect the energy consumption are for example indoor tem perature hot water consumption the insulation level of the house and whether the house has many large window surfaces The position of the house e g wind exposure is also an affecting factor If you activate Hot water Economy less energy is used Power consumption Increasing the indoortemperature one degree increases power consump tion by approx 5 Domestic electricity In the past it has been calculated that an average Swedish household has an approximate annual consumption of 5000 kWh domestic electri city year In today s society it is usually between 6000 12 000 kWh year Eguipment Normal Output Approx W imate annual con sump tion kWh Standby Flat screen Operation 5 h day Standby 19 h day Digital box Operation 5 h day Standby 19 h day DVD Operation 2 h week Chapter 2 The control module the heart of the house NIBE SMO A0 19 Equipment Normal Output Approx W imate annual con sump tion TV games console Operation 6 h week 160 2 Radio stereo Operation 3 h day Computer incl screen Operation 3 h day 100 standby 21 h day Bulb Operation 8 h day 60 pot light Halogen Operation 8 h day Dishwasher cold water connection Opera 2000 tion 1 time d
28. egain usual levels TIP Set the vacation setting in advance and activate just before departure in order to maintain the comfort Caution If you choose to switch off hot water production during the vacation periodic increases preventing bacterial growth are blocked during this time periodic increases started in conjunction with the vacation setting being completed advanced Menu 665 has orange text and is intended for the advanced user This menu has several sub menus Chapter 3 Menu 4 9 1 Menu 4 9 2 op prioritisation op prioritisation Setting range 0 to 180 min Default value 30 min hot water 30 1 heating E min pool min Fa Choose here how long the installation should work with each requirement if there are several requirements at the same time If there is only one re quirement the installation only works with that requirement The indicator marks where in the cycle the installation is If O minutes is selected it means that requirement is not prioritised but will only be activated when there is no other requirement auto mode setting stop heating Setting range 20 40 C Default values 20 stop additional heat stop heating EN C Setting range 25 40 C stop additional heat Gk Default values 15 filtering time filtering time Setting range 0 48 Default value 24 h when the operating mode is set to auto the control module selects when start an
29. g gap of 3 mm NOTE If the supply cable is damaged only NIBE its service representative or similar authorised person may re place it to prevent any danger and damage Symbols NOTE This symbol indicates danger to machine or person Caution This symbol indicates important information about what you should ob serve when maintaining your installation TIP This symbol indicates tips on how to facilitate using the product Chapter 1 Marking SMO 40 is CE marked and fulfils IP21 The CE marking means that NIBE ensures that the product meets all regu lations that are placed on it based on relevant EU directives The CE mark is obligatory for most products sold in the EU regardless where they are made IP21 means that the product can be touched by hand that objects with a diameter larger than or equivalent to 12 5 mm cannot penetrate and cause damage and that the product is protected against vertically falling drops Chapter 1 Serial number The serial number can be found on the upper side of the cover on the control module Serial number Caution Always give the product s serial number when reporting a fault Chapter 1 Important information NIBE SMO 40 5 Contact information AT CH CZ DE DK 2 FR GB NL NO PL RU KNV Energietechnik GmbH Gahberggasse 11 4861 Sch rfling Tel 43 0 7662 8963 0 Fax 43 0 7662 8963 44 E mail mail knv at www knv at NIBE Warme
30. haracter table press the Back button If a menu only has one character set the keyboard is displayed directly When you have finished writing mark OK and press the OK button Chapter 2 17 18 Scroll through the windows A menu can consist of several windows Turn the control knob to scroll between the windows Current menu Number of windows window in the menu Scroll through the windowvs in the start guide Arrows to scroll through window in start guide 1 Turn the control knob until one of the arrows in the top left corner at the page number has been marked 2 Press the OK button to skip between the steps in the start guide Help menu wee In many menus there is a symbol that indicates that extra help is available A ei To access the help text 1 Use the control knob to select the help symbol 2 Press the OK button The help text often consists of several windows that you can scroll between using the control knob Chapter 2 Maintenance of SMO 40 Regular checks Your heat pump requires minimal maintenance after commissioning On the other hand it is recommended that you check your installation regu larly For more information regarding the maintenance of heat pumps and or accumulator tanks water heaters refer to the relevant manual If something unusual occurs messages about the malfunction appear in the display in the form of different alarm texts See alarm management on pag
31. if the pressure is too high Shuttle valve A valve that can send liquid in two directions A shuttle valve that enables liquid to be sent to the climate system when the heat pump produces heating for the house and to the hot water heater when the heat pump produces hot water Supply temperature The temperature of the heated water that the heat pump sends out to the heating system The colder the outdoor temperature the higher the supply line temperature becomes Chapter 6 63 64 Item register A Adjust the installation 40 Alarm 55 B Back button 11 C Contact information 6 Contact with SMO 40 9 Display unit 10 External information 9 Menu system 12 Control knob 11 Control module s function 9 D Display 10 Display unit 10 Back button 11 Control knob 11 Display 10 OK button 11 Status lamp 10 Switch 11 Disturbances in comfort 55 Alarm 55 Manage alarm 55 Only additional heat 58 Troubleshooting 56 E External information 9 Information window 9 Status lamp 9 G Get information 37 Glossary 60 H Help menu 18 Important information 2 Contact information 6 Installation data 2 Serial number 5 SMO 40 An excellent choice 8 Information window 9 Chapter 7 Installation data 2 M Maintenance of SMO 40 19 Regular checks 19 Saving tips 19 Manage alarm 55 Menu system 12 Help menu 18 Operation 14 Scroll through the windows 18 Selecting men
32. ioritised active displays if any part of the schedule is active otherwise it displays off Setting of heat curve adjusting with external contact minimum value for supply temperature own curve and point offset temperature temperature If the house has several climate sys tems this is indicated on the display by a thermometer for each system temperature 1 1 Set the temperature with room sensors installed and activated Setting range 5 30 C Default value 20 The value in the display appears as a temperature in C if the heating system is controlled by a room sensor To change the room temperature use the control knob to set the desired temperature in the display Confirm the new setting by pressing the OK button The new temperature is shown on the right hand side of the symbol in the display Chapter 3 21 22 Setting the temperature without room sensors activated Setting range 10 to 10 Default value O The display shows the set values for heating curve offset To increase or reduce the indoor temperature increase or reduce the value on the display Use the control knob to set a new value Confirm the new setting by pressing the OK button The number of steps the value has to be changed to achieve a degree change of the indoor temperature depends on the heating installation One step is usually enough but in some cases several steps may be required Setting the desired value
33. it read off mode Chapter 3 39 Menu 4 1 40 Adjust the heat pump Overview Sub menus For the menu ES there are res fi several sub menus Status Information plus functions x for the relevant menu can be found on the display to the right of the op mode menus L E my icons Rese Settings applying to a any Installed extra functions in the ng heating system language language UTE Activation of manual or holiday setting automatic operating mode The status information shows the selected oper ating mode KEES Settings regarding which icons in the control module s user in terface that are to appear on the hatch when the door is closed le EH Setting current time and date ERERERE Select the language for the display here The status information shows the selected language Vacation scheduling heating and hot water comfort tatus information set is displayed if you set a vacation schedule but it is not active at the moment active is displayed if any part of the vacation schedule is active otherwise it displays off Settings of control module work mode plus functions Settings for any additional functions installed in SMO 40 can be made in the sub menus pool plus functions4 1 j _ pool 2 internet sms Chapter 3 Menu pool 1 pool 2 accessory is required See SE 4 1 2 pool4 1 1 Setting range 5 0 80 0 C Default value 22 0 C
34. kiy Nizhny Novgorod Tel fax 7 831 419 57 06 E mail info evan ru www nibe evan ru Chapter 1 SE NIBE AB Sweden Box 14 Hannabadsvagen 5 SE 285 21 Markaryd Tel 46 0 433 73 000 Fax 46 0 433 73 190 E mail infoQnibe se www nibe se For countries not mention in this list please contact Nibe Sweden or check www nibe eu for more information Chapter 1 SMO 40 An excellent choice SMO 40 is an electric control module which has been introduced to supply your home with inexpensive and environmentally friendly heating Heat production is reliable and economical with a NIBE air water heat pump and accumulator water heater An additional heater for example electric oil gas boiler can engage automatically if something unexpected should occur or as reserve opera tion Excellent properties for SMO 40 Easy to read display The control module has an easy to read colour display with easy to un derstand menus that facilitate setting a comfortable indoor climate Easy to install SMO 40 is easy to install together with a compatible NIBE air water heat pump When installing together with these the control module is con nected to the heat pump which enables you to see any heat pump alarms in SMO 40 The size of the control module means that it can be installed on walls indoors for easy access to control your installation Chapter 1 The control module the heart of the house Control module s function SMO 40 i
35. mum accommodation temperature The colder the outdoor temperature the higher the calculated supply temperature Circulation pump Pump that circulates liquid in a pipe system Climate system Climate systems can also be called heating systems The building is heated using radiators under floor coils or convector fans Compressor Compresses the gas state refrigerant When the refrigerant is compressed the pressure and the temperature increase Condenser Heat exchanger where the hot gas state refrigerant condenses cooled and becomes a liquid and releases heat energy to the house heating and hot water systems COP If it is stated that a heat pump has COP 4 this means in principle that if you insert 10 pence you will get 40 pence worth of heat It is the efficiency of the heat pump This is measured at different measurement values e g 7 45 where 7 stands for the outdoor temperature and 45 for how many degrees the supply temperature is Disturbances in comfort Disturbances in comfort are undesirable changes to the hot water indoor Comfort for example when the temperature of the hot water is too low or if the indoor temperature is not at the desired level A malfunction in the heat pump can sometimes be noticed in the form of a disturbance in comfort Chapter 6 In most cases the heat pump notes operational interference and indicates this with alarms and shows instructions in the display Domestic hot water The
36. ncreased until the desired room temper ature is maintained Caution Wait 24 hours before making a new setting so that the room temperature has time to stabilise Chapter 3 31 Menu 2 1 32 Set the hot water capacity Overview Sub menus HOT WATER 2 This menu only appears if a water heater is docked to the heat pump For the menu EAEN there are temporary lux off several sub menus Status information H for the relevant menu can be found comfort mode economy on the display to the right of the menus scheduling active Activation of tempor ary increase in the hot water temper ature Status information displays off or what length of time of the temporary temperature increase remains Setting hot water comfort The status information displays what mode Is selected economy normal or luxury SC Scheduling hot water comfort The status information set appears IT you have set scheduling but it is not currently active holiday setting appears if holiday setting is active at the same time as scheduling when the holiday function is prioritised active appears if any part of scheduling is active otherwise off appears Setting periodic increase in the hot water temperature temporary lux Setting range 3 6 and 12 hours temporary lux 2 1 and mode off Default value off When hot water requirement has temporarily increased this menu can be used to select an increa
37. ng the OK button Chapter 2 Selecting options comfort mode 2 2 gj economy L normal _ luxu Alternative In an options menu the current selected option is indicated by a green A tick To select another option 1 Mark the applicable option One of the options is pre selected white 2 Press the OK button to confirm the selected option The selected 6 option has 8 green tick hd kd Chapter 2 15 16 Setting a value time amp date4 4 time ENK 2A hrs JE date 14 day O 14 06 2088 06 month W 2013 06 14 Values to be changed To set a value d Ss a Mark the value you want to set using the control knob at al Press the OK button The background of the value becomes green which means that you have 86665560 the setting mode CH Turn the control knob to the right to increase the value and to 3 the left to reduce the value L Press the OK button to confirm the value you have set To change na and return to the original value press the Back button et A Chapter 2 Use the virtual keyboard Different keyboards In some menus where text may require entering a virtual keyboard is available 6 s e P G 2 5 T Ll V vv A Depending on the menu you can gain access to different character sets which you can select using the control knob To change c
38. nstallation shows operating times number of starts etc for the compressor in the heat pump times etc shows the latest alarms service info compressor info add heat info alarm log t indoor temp log displays information about the additional heat s operating OAA the average temperature indoors week by week during the past year service info Information about the actual operat ing status of the installation e g cur rent temperatures etc can be ob tained here No changes can be made The information is on several pages Turn the control knob to scroll between the pages Symbols in this menu Com a pressor Addition Hot wa ter e Heating medium pump orange Heating Chapter 3 status op prioritisation hot water charging hot water top calculated flow temp degree minutes outdoor temp ext heat med pump charge pump speed i service info 3 1 AA25 hot water 49 0 C 52 0 C 5 8 C 700 5 6 C runs 57 37 Menu 3 2 Menu 3 3 38 compressor info Information about the compressor s operating status and statistics can be obtained here No changes can be made The information is on several pages Turn the control knob to scroll between the pages add heat info Information about the additional heat s settings operating status and statistics can be obtained here No changes can be made The informati
39. o change and receive 6000 e status information from the control module Mobile numbers must include country code e g 46 XXXXXXXX If you want to receive an SMS mes sage in the event of the alarm mark the box to the right of the telephone number N NOTE Telephone numbers provided must be able to receive SMS messages Menu SG Ready 4 1 5 This function can only be used in mains networks that support the SG Ready standard Germany Make settings for the function SG affect room temperature 6 Ready here affect hot water V SG Ready 4 1 5 affect pool temperature affect room temperature Here you set whether room temperat ure should be affected when activat ing SG Ready With low price mode of SG Ready the parallel offset of the indoor tem perature is increased by 1 If a room sensor is installed and activated the desired room temperature increases by 1 C With over capacity mode of SG Ready the parallel offset for the indoor temperature is increased by 2 If a room sensor is installed and activated the desired room temperature increases by 2 C affect hot water Here you set whether the temperature of the hot water should be affected when activating SG Ready 44 Chapter 3 Menu 4 2 With low price mode on SG Ready the stop temperature of the hot water is set as high as possible at only compressor operation immersion heater not permitted With over capacity mode of SG Rea
40. on is on several pages Turn the control knob to scroll between the pages Chapter 3 compressor info 3 2 status number of starts total operating time of which hot water add heat info 3 3 status time factor Menu alarm log 3 4 To facilitate fault finding the installa alarm log 3 4 tion s operating status at alarm alerts Mo is stored here You can see informa tion for the 10 most recent alarms To view the run status in the event of an alarm mark the alarm and press the OK button alarm log 3 4 outdoor temp condenser return condenser out addition hot water charging heat medium flow evaporator operating time op mode Information about an alarm Menu indoor temp log 3 5 Here you can see the average temper MEL ature indoors week by week during el the pastyear The dotted line indicates the annual average temperature The average outdoor temperature is only shown if a room temperature sensor room unit is installed To read off an average temperature 1 Turn the control knob so that the ring on the shaft with the week number is marked 2 Press the OK button 3 Follow the grey line up to the graph and out to the left to read off the average indoor temperature at the selected week 4 You can now select to take read outs for different weeks by turning the control knob to the right or left and read off the average temper ature 5 Press the OK or Back button to ex
41. s a simple electrical control module which together with NIBE air water heat pump accumulator water heater and additional heater e g electric oil gas boiler creates a complete installation Among other things it controls the heat pump circulation pumps reversing valves and additional heat to supply your home with inexpensive and environmentally friendly heating in the most efficient way Contact with SMO 40 External information When the control module door is closed information can be received via an information window and a status lamp Information window Status lamp Information window The information window shows part of the display that is on the display unit located behind the door to the control module The information window can display different types of information e g temperatures clock status etc You determine what is to be displayed in the information window Your own combination of information is entered using the display unit This information is specific to the information window and disappears when the front hatch of the control module is opened Instructions on how to set the information window can be found on page 46 Status lamp The status lamp indicates the status of the control module continuous green light during normal function continuous yellow light during activ ated emergency mode or continuous red light in the event of a deployed alarm Chapter 2 Alarm management is describe
42. se in the hot water temperature to lux mode for a selectable time Chapter 3 Menu 2 2 Menu 2 3 Caution If comfort mode luxury is selected in menu 2 2 no further increase can be carried out The function is activated immediately when a time period is selected and confirmed using the OK button The remaining time for the selected setting is shown to the right When the time has run out SMO 40 returns to the mode set in menu 2 2 Select off to switch off SA d comfort mode Setting range economy normal comfort mode 2 2 luxury Default value normal b i economy JR _ normal luxury The difference between the selectable modes is the temperature of the hot tap water Higher temperature means that the hot water lasts longer economy This mode gives less hot water than the other but is more economical This mode can be used in smaller households with a small hot water reguirement normal Normal mode gives a larger amount of hot water and is suitable for most households luxury Lux mode gives the greatest possible amount of hot water In this mode the immersion heater as well as the compressor is used to heat hot water which may increase operating costs scheduling Two different periods of hot water comfort per day can be scheduled here Scheduling is activated deactivated by ticking unticking activated Set times are not affected at deactivation Chapter 3 33 34 Activ
43. set If there is more than one climate system the setting can be made separately for each system Chapter 3 Menu 1 93 Menu 1 9 4 min flow line temp climate system Setting range 5 70 C Default value 20 C climate system 1 climate system 2 climate system 3 climate system 4 Set the minimum temperature on the supply temperature to the climate system This means that SMO 40 never calculates a temperature lower than that set here If there is more than one climate system the setting can be made separately for each system TIP The value can be increased if you have for example a cellar that you al ways want to heat even in summer You may also need to increase the value in stop heating menu 4 9 2 auto mode setting room sensor settings factor system Setting range 0 0 6 0 Default value 2 0 control room sensor syst 1 factor system 1 control room sensor syst 2 control room sensor syst 3 factor system 3 control room sensor syst 4 Room sensors to control the room temperature can be activated here Here you can set a factor a numerical value that determines how much an over or sub normal temperature the difference between the desired and actual room temperature in the room is to affect the supply temper Chapter 3 29 Menu 1 9 7 Menu 1 9 8 30 ature to the climate system A higher value gives a greater and faster change of the heating curve s set offset
44. similar scheduling for every day of the week start by filling in all and then changing the desired days TIP Set the stop time earlier than the start time so that the period extends beyond midnight Scheduling then stops atthe setstop time the day after Scheduling always starts on the date that the start time is set for Chapter 3 53 CP Caution Long term scheduling of quiet mode can cause reduced comfort and operating economy 54 Chapter 3 4 Disturbances in comfort IN most cases the control module notes a malfunction and indicates this with alarms and shows instructions to rectify it in the display See Manage alarm for information about managing alarms If the malfunction does not appear in the display or if the display is not lit the following troubleshooting guide can be used Manage alarm In the event of an alarm some kind of Fam malfunction has occurred which is Low pressure alarm indicated by the status lamp changing trom green continuously to red con tinuously In addition an alarm bell appears in the information window info action Alarm reset alarm In the event of an alarm with a red C aid mode status lamp a malfunction has oc curred that the heat pump and or control module cannot remedy itself In the display by turning the control knob and pressing the OK button you can see the type of alarm it is and reset it You can also choose to set the installation to aid mode info
45. t applicable settings use the automatic mode or contact your network administrator or similar for further information TIP All settings made since opening the menu can be reset by marking reset and pressing the OK button proxy settings You can set proxy settings for your proxy settings 4 1 3 9 installation here Proxy settings are used to give connec BK Adu tion information to a intermediate server server proxy server between the in ER stallation and Internet These settings Ms are primarily used when the installa Gi tion connects to the Internet via a company network The installation supports proxy authentication of thec LL mm HTTP Basic and HTTP Digest type If unsure about applicable settings use the preset settings or contact your network administrator or similar for further information fe Setting Tick use proxy if you do not want to use a proxy Mark server and press the OK button Enter the correct details via the virtual keypad Mark OK and press the OK button Repeat 1 3 for port user name and password Mark confirm and press the OK button GY a Ek ee Chapter 3 43 AL TIP Y All settings made since opening the menu can be reset by marking reset and pressing the OK button Menu sms accessory is required 4 1 4 Make settings for the accessory SMS e sms 4 1 4 40 bere Add the mobile numbers that are to MEL alarm receiver have access t
46. technik AG Winterthurerstrasse 710 CH 8247 Flurlingen Tel 52 647 00 30 Fax 52 647 00 31 E mail info nibe ch www nibe ch Druzstevni zavody Drazice s r o Drazice 69 CZ 294 71 Benatky nad Jizerou Tel 420 326 373 801 Fax 420 326 373 803 E mail nibe nibe cz www nibe cz NIBE Systemtechnik GmbH Am Reiherpfahl 3 29223 Celle Tel 05141 7546 0 Fax 05141 7546 99 E mail infoQnibe de www nibe de V lund Varmeteknik A S Member of the Nibe Group Brogardsvej 7 6920 Videb k Tel 97 17 20 33 Fax 97 17 29 33 E mail info volundvt dk www volun dvt dk NIBE Energy Systems OY Juurakkotie 3 01510 Vantaa Puh 09 274 697 O Fax 09 274 697 40 E mail info nibe fi www nibe fi AIT France 10 rue des Moines 67000 Haguenau Tel 03 88 06 24 10 Fax 03 88 06 90 15 E mail info nibe fr www nibe fr NIBE Energy Systems Ltd 3C Broom Business Park Bridge Way Chesterfield S41 9QG Tel 0845 095 1200 Fax 0845 095 1201 E mail info nibe co uk www nibe co uk NIBE Energietechniek B V Postbus 634 NL 4900 AP Oosterhout Tel 0168 477722 Fax 0168 476998 E mail info nibenl n l www nibenl nl ABK AS Brobekkveien 80 0582 Oslo Postadresse Postboks 64 Vollebekk 0516 Oslo Tel sentralbord 47 23 17 05 20 E mail post abkklima no www nibeen ergysystems no NIBE BIAWAR Sp 2 o o Aleja Jana Pawla ll 57 15 703 BIALYSTOK Tel 085 662 84 90 Fax 085 662 84 14 E mail sekretariat biawar com pl www biawar com pl EVAN 17 per Boynovs
47. than the set maximum value or lower than the set minimum value the N heating curve flattens out at these temperatures 10 0 10 20 30 40 C Outdoor temperature Caution Underfloor heating systems are normally aab ile set between 35 and 45 C Check the max temperature for your floor with your installer tloor supplier The figure at the end of the curve indicates the curve slope The figure beside the thermometer gives the curve offset Use the control knob to set a new value Confirm the new setting by pressing the OK button Curve 0 is an own heating curve created in menu 1 9 7 Chapter 3 To select another heat curve slope NOTE If you only have one heating system the number of the curve is already marked when the menu window opens 1 5 Select the system if more than one for which the heat curve is to be changed When the system selection has been confirmed the heat curve number is marked Press the OK button to access the setting mode Select a new heating curve The heat curves are numbered from 0 to 15 the greater the number the steeper the slope and the areater the supply temperature Heating curve 0 means that menu 1 9 7 is used Press the OK button to exit the setting To read off a heating curve 1 2 3 Turn the control knob so that the ring on the shaft with the outdoor temperature is marked Press the OK button Follow the grey line up to the heat
48. u 14 Selecting options 15 Setting a value 16 Use the virtual keyboard 17 0 06 button 1 Only additional heat 8 Operation 14 P Power consumption 19 R Regular checks 19 5 Saving tips 9 Power consumption 19 Scroll through the windows 18 Selecting menu 14 Selecting options 15 Serial number 5 Set the hot water capacity 32 Set the indoor climate 21 Setting a value 16 SMO 40 An excellent choice 8 SMO 40 at your service 21 Adjust the installation 40 Get information 37 Set the hot water capacity 32 Set the indoor climate 21 Status lamp 9 10 Switch 11 T Technical data 59 The control module the heart of the house 9 Troubleshooting 56 U Use the virtual keyboard 17 Chapter 7 65 66 Chapter 7 NIBE SMO 40 Chapter 7 NIBE SMO 40 67 68 Chapter 7 NIBE SMO 40 NIBE AB Sweden Hannabadsv gen 5 Box 14 SE 285 21 Markaryd info nibe se www nibe eu 231761
49. week start by filling in all and then changing the desired days TIP Set the stop time earlier than the start time so that the period extends beyond midnight Scheduling then stops at the set stop time the day after Scheduling always starts on the date that the start time is set for Caution Long term blocking can cause reduced comfort and operating economy schedule silent mode The compressor can be scheduled to be set to quiet mode the heat pump must support this for up to two different time periods here When scheduling is active the quiet mode symbol is shown in the main menu on the symbol for the control module Chapter 3 Activated Schedule chedule 1 schedule 2 E activated all mon tues we thur 4400 1620 Conflict Day Time period Schedule The period to be changed is selected here Activated Scheduling for the selected period is activated here Set times are not affected at deactivation Day Select which day or days of the week the schedule is to apply to here To remove the scheduling for a particular day the time for that day must be reset by setting the start time to the same as the stop time If the line all is used all days in the period are set for these times Time period The start and stop time for the selected day for scheduling are selected here Conflict H two settings conflict with each other a red exclamation mark is displayed TIP If you wish to set
50. y normal water which is sent from the heat pump to the house climate system and makes the accommodation warm The heating medium also heats the hot water through the double jacketed tank or coil tank Heating medium side Pipes to the house s climate system and condenser make up the heating medium side Hot water heater Container where domestic water is heated Is located somewhere outside the heat pump Mixing valve A valve that mixes the cold water with the hot water leaving the heater Outside sensor A sensor that is located outdoors This sensor tells the heat pump how hot it is outdoors Pressostat Pressure switch that triggers an alarm and or stops the compressor if non permitted pressures occur in the system A high pressure pressostat trips if the condensing pressure is too great A low pressure pressostat trips if the evaporation pressure is too low Radiator Another word for heating element They must be filled with water in order to be used with SMO 40 Return pipe The line in which the water is transported back to the heat pump from the house heating system radiators heating coils Return temp The temperature of the water that returns to the heat pump after releasing the heat energy to the radiators heating coils Room sensor A sensor that is located indoors This sensor tells the heat pump how hot it is indoors Chapter 6 Safety valve A valve that opens and releases a small amount of liquid
Download Pdf Manuals
Related Search
Related Contents
適用申請書 - 地域型住宅ブランド化事業 Behmor Brazen Coffee Brewer User`s Manual Microprocesador M52 - ClimateWorx International 03- 421944012421 Lirika_PL-DE-00.indd REFERENCE AMPLIFIER A500 Manual de instrucciones para la batidora Globe Modelo SP8 Römer Kid Plus Enjoy it. - BLAUPUNKT 取扱説明書 - OS Engines ※仕様および外観は改善のため予告なく 変更する場合があります。 Copyright © All rights reserved.