1. User Manual Bitalino PILK WIRELESS BIOSIGNALS S r open Title OpenSignals User Manual Bitalino Author Plux Wireless Biosignals S A Last edited May 2014 OpenSignals version 1 4 1 PIL WIRELESS BIOSIGNALS S A OpenSignals Manual Plux Wireless Biosignals Index OpenSignals Manual Plux Wireless Biosignals 1 Introduction Plux Wireless Biosignals S A creates innovative products for Physiotherapists and Researchers by developing advanced biosignal monitoring platforms that integrate wearable body sensors such as electromyography EMG and electrocardiography ECG combined with wireless connectivity and software applications to deliver real value recognized by its target markets OpenSignals is then the software responsible for the handle of all the data acquisition visualization and processing while using Plux s biosignal platforms The purpose of this manual is to introduce the reader on how to fully work with OpenSignals exploring all its features and options This version of the manual covers the OpenSignals version release for Bitalino OpenSignals Manual Plux Wireless Biosignals 2 Installation 2 1 Requirements Operating System Windows x86 32 bit Windows x86 64 bit 2 2 Installing OpenSignals OpenSignals may be found online under the following Link OpenSignals 1 3 1 Core http downloads plux info OpenSignalsBlT OpenSignalsSetup1 3 1 0 exe Download the file run
2. so you dont need to worry about reconfiguring a device s channels after you de select and re select it Figure 4 10 Configuration page for acquisition Section for channel configuration BlTalino devices have 6 analog channels that may be used to acquire biosignals select which ones you would like to acquire from Set the labels the channel s name tag in the input boxes and set the sensors using each channel s respective combo box As a sensor it is possible to select one of the following CUSTOM ECG EMG EDA ACC LUX and ABAT By selecting each one except CUSTOM the respective conversion formula will be applied to the signal CUSTOM allows you to configure the conversion formula by clicking and defining the formula s offset gain and unit Figure 4 11 The conversion parameters are saved for each channel of each device so there is no need in redefining them 14 OpenSignals Manual Plux Wireless Biosignals Edit parameters for device 1 channel 5 offset Figure 4 11 Configuration page for acquisition Section for channel configuration Pop up for customizing a channel s conversion formula BlTalino has 4 digital outputs that may be defined by toggling it on off while in the configuration page It is also possible to toggle each one of them in real time while in Acquisition mode 15 OpenSignals Manual Plux Wireless Biosignals 5 Visualization The Visualization page allows
3. axis range Shortcut Up Arrow X axis compress button Reduces de X axis range Shortcut Left Arrow X axis expand button Extends de Y axis range Shortcut Right Arrow OO Start Stop button Starts Stops the acquisition Whenever you stop the acquisition a pop up will spawn with the options to save you file The generated filename will be composed by the File Prefix Tag and Timestamp File Prefix Tag Timestamp h5 See Figure 4 2 The file will be saved under the File Path directory Both the Tag list and the File Path may be previously configured in the configuration page See 4 2 Acquisition Configuration Page Do you want to save the data This is a point of no return File Prefix Individuali Tag ExerciseA Filename Individual1_ExerciseA_ timestamp h5 File Path C Users Figure 4 2 Data save pop up 4 2 Acquisition Configuration Page This page is separated in 4 sub sections Figure 4 3 Device identification Contains the list of all devices added to OpenSignals and which of these devices is going to acquire once in the Acquisition mode Save to The path on where the created files are being saved to Additionally it allows you to predefine a list of tags to better identity your files define the file type and write comments to file Acquisition configuration Acquisition properties 10 OpenSignals Manual Plux Wireless Biosignals Channel configuration You can configure
4. it and follow the instructions to automatically install the software on your computer 2 5 Updating OpenSignals OpenSignals is separated in two parts Core OpenSignals environment with all the required libraries and secondary software such as python and google chrome OpenSignals Core is rarely changed and represents around 95 of the software size Source OpenSignals behavior with the visuals and instructions OpenSignals Source may be changed often In terms of size it represents the remaining 5 of the software Such separation allows us to automatically update OpenSignals after installed on your computer without disturbing your workflow or wasting your precious time We do this by automatically downloading the last Source on software startup due to its relatively small size 5 of software you won t even notice it After downloading and installing the Core mentioned before See 2 2 Installing OpenSignals an Internet connection is still required to download the last Source Whenever the OpenSignals Core is changed it is up to you to decide when and if the new Core should be downloaded and installed See Figure 2 1 this is because it may take some time to complete If you decide to install the new Core wait until the download completes When the download is completed the setup is started for you just follow the OpenSignals Manual Plux Wireless Biosignals installation instructions to automatically inst
5. sampling frequency sampling resolution and time date the device mac address and device type and of course the biometric data OpenSignals Manual Plux Wireless Biosignals HDF5 file format h5 extension Holds additional metadata like device events digital output changes and channel settings sensors gains offsets units and labels OpenSignals Manual Plux Wireless Biosignals 4 Acquisition 4 1 Real Time Acquisition Page Vp OPE aD signals 009000 OO BE Digital Input Digital Output E A Figure 4 1 Acquisition page for OpenSignals Accessing this page will open a connection with your Bitalino device and start retrieving the data in real time The channels that are being acquired its labels and conversion formulas may be configured in the O configuration page See 4 2 Acquisition Configuration Page The bottom of the page displays the 4 digital inputs that are being received and allows you to change the 4 digital outputs by toggling the respective radio box Additionally it is possible to hide show a channel by pressing its respective number on the keyboard or expand a single channel by double clicking it Button Description O Home button Redirects to the main page Configuration button Redirects to the configuration page for acquisition OpenSignals Manual Plux Wireless Biosignals Y axis compress button Reduces de Y axis range Shortcut Down Arrow Y axis expand button Extends de Y
6. you to view a previously acquired signal by opening its respective file created during acquisition To change which file is being open change it in the configurations See 5 2 Visualization Configuration 5 1 Visualization Page Oop en Saral Figure 5 1 Visualization page The key mapped shortcuts and page buttons are explained below Double click channel Vertically expands the channel Keyboard Zooms in all channels Keyboard Zooms out all channels Keyboard 1 8 Fades in out channel 1 8 Button Description Home button Redirects to the main page Configuration button Redirects to configuration page for visualization 16 OpenSignals Manual Plux Wireless Biosignals 5 2 Visualization ConfigurationPage This page allows you to select a file from your local file system Files under the HDF5 format h5 extension are ready to open Simply select which channels are to be displayed and open the file You will be redirected to the Visualization Mode using the selected file Figure 5 2 channels configuration active channels label HANDGRIP CUSTOM Figure 5 2 Channel selection for visualization of a previous acquisition file txt Files under the Text format txt extension must undergo a small conversion step into HDF5 format The new h5 file is created under the same directory but it has no additional metadata regarding channel sett
7. all the software on your computer Again an Internet connection is required to download the new Source for the new Core C plux sun code NOpenSignals gt chdir C plux sun code Open ignals C plux sun codeN Open ignals gt python2 python exe code main py Updater checking for updates please wait Updater OpenSignals core has been changed and needs to be re installed Updater would you like to download the new OpenSignals core ND Figure 2 1 Waiting for user command to download the new Core or continue using the outdated one Even if you decide to reject the new Core the last Source for your current one is still downloaded and installed OpenSignals Manual Plux Wireless Biosignals 4 Introducing OpenSignals 4 1 Welcome to OpenSignals If the software was correctly installed you should find an icon for OpenSignals use it and welcome to OpenSignals Ap open 7 UMAD EUROPEIA Ve tere nahn paratra rename fa Sonea es Magee Figure 3 1 Main page for OpenSignals From this main page you have access to Acquisition Real time acquisition of biosignals using a Bitalino An in depth tutorial of acquisition mode Is given in 4 Acquisition Visualization Previously acquired signals may be viewed here For more information consult 5 Visualization 5 2 File formats OpenSignals uses two types of file formats Text file format txt extension Holds information regarding the acquisition process
8. ction for tags file path file type and comments Directory path The path to where the files created during acquisition are being saved to is set here It is possible to either manually insert the path or use Ue O to select a directory from the computer s file system Tag list An editable list of tags that may be used during Acquisition mode to name the created files such allows one to better identify each created file Click over each tag to remove it To add one use CET to open the popup shown below Figure 4 8 insert new tag Figure 4 8 Configuration page for acquisition Section for tags file path file type and comments Add tag popup File extension to save The extension for the files created during acquisition Possibilities are xt or h5 More information on these options may be found at 3 2 File formats Comments Any additional information to be added to the file It is only available when using h5 extension files 13 OpenSignals Manual Plux Wireless Biosignals 1 1 3 Acquisition configuration acquisition configuration Figure 4 9 Configuration page for acquisition Section for acquisition configuration Sampling frequency Number of samples per second Possible values are 1 10 100 and 1000 Hz 1 1 4 Channel configuration Whenever a device is selected for acquisition its channel configuration is presented for editing Each device has its own channel configuration memory
9. each channel in this section These sub modules are explained in depth on the next sections All of your configurations are automatically and instantly saved upon change so you dont have to worry about re configuring your acquisitions and devices Using the begin acquisition button in the bottom of this page will redirect you to the Acquisition mode OpenSignals device identification selected devices available devices device 1 98 D3 31 B1 84 2C directory path C lUsers filename tags file extension to save acquisition configuration channel configuration device 1 begin acquisition Figure 4 3 Configuration page for acquisition 1 1 1 Device identification device identification selected devices available devices add device Figure 4 4 Configuration page for acquisition Device identification 11 OpenSignals Manual Plux Wireless Biosignals On the right side of this section there is a list containing your devices Click over each one of them to select them for acquisition To remove a device from this list simply use the next to it To add a new device use the under the list this will open a popup to help you search for nearby devices and attach new ones to the software Figure 4 5 insert mac address or search for devices Figure 4 5 Configuration page for acquisition Add device popup It is possible to either type in the mac address of the device or
10. ings See 3 2 File formats Upon selection of the file you may choose which channels are to be displayed and begin the conversion Figure 5 3 You will be redirected to the Visualization Mode using the converted h5 file OpenSignals Figure 5 3 Channel selection for visualization of a previous acquisition file h5 17
11. search for nearby devices and pick one Use to check and add the device to the list or to cancel the action Since the device is a BlTalino it is required to pair the device with the computer before this step may take place To do this open the Windows Bluetooth device finder and search for devices in range Pair with the BlTalino using the pairing code 1234 Figure 4 6 Q BP Adda device G F Add a device Select a device to add to this computer Select a pairing option Windows will continue to look for new devices and display them here gt Create a pairing code for me of The device has a keypad bitalino Other bitalino gt Enter the device s pairing code The device comes with a pairing code Check for one on the device or in the device manual gt Pair without using a code This type of device such as a mouse does not require a secure connection What if Windows doesn t find my device How can LL if my vice has airin Next Cancel Nex Cancel Figure 4 6 Pairing a BITalino device with the computer Under selected devices is the device that will be acquiring once in the Acquisition mode Clicking over it will de select it and place it back in the available devices list 12 OpenSignals Manual Plux Wireless Biosignals 1 1 2 Save to directory path C Users tag list file extension to save z D patientID 3421 comments Figure 4 7 Configuration page for acquisition Se