1. Power Input 230V a c 10 50Hz Max Loop Resistance 2K Ohm Loop Delay Time 300 milliseconds Fuses Mains 125mA Anti Surge Aux 1A Quick Blow Low Voltage Output 13 8V typical Regulated Power Supply Rating 1A Battery Sizes Metal Version 12V 1 2Ah 2 0Ah 3 0Ah 7 0Ah Plastic Version 12V 1 2Ah 2 0Ah Construction Metal Version 1 2mm Mild Steel Plastic Version 3mm Polycarbonate Complies with B S 4737 Number of Zones 7 Tamper RKP E E Zone on 580 style RKPs Display Type 2 x 7 segment LED except ACE RX User Code Default 5678 Engineer Code Default 1234 Event Log Size 80 No of User Codes 9 No of Part Sets Page 14 Resetting After an Alarm Four reset modes are available after an alarm These are as follows Any Code The system will reset the next time Any Code is used to set the system Master Code The system will only reset if the Master Code or Engineer code is used to set the system Engineer Code The system will only reset if the Engineer Code is used to set the system Anti Code The system may only be reset by use of an Anti Code The engineer code may be used to override the Anti Code Reset To Reset System 1 Enter Code of correct type see above 2 Proceed to set the system 3 If a set is not required re enter the code to abort setting To Reset by Anti Code 1 Make a note of the Code given by the display 2 Using the Gardiner Technology Anti Code software on a P C or an Anti Code Generator ent
2. Fig5 Engineer Programming Flow Chart fees System is Unset Enter Engineer Code Press 0 Quit Do you wish to use Engineer Mode Press NO Press O Quit BA This is Engineer Mode Enter Option Number Then YES 4 Press NO This is the Existing Setting Press NO Press NO Press NO Enter new Setting Here Press NO Enter New Value Then Press YES Press YES Enter new Engineer Code Press YES Re Enter Engineer Code Press YES Press 0 to return to Unset Page 8 Programmable Options Description This section will give a description of the programmable options that are available on the GARDTEC 370 Control Panel For more details of the parameters available for each option please refer to the section Programming Charts Zone 1 7 Attributes Option No 1 7 This option allows the zone type zone part set remove and zone chime features to be programmed for zone 1 7 Sounder Level Option No 8 This option allows for the fine adjustment of the speaker volume for Entry Exit tone and Chime to be programmed Coarse adjustment is via the potentiometer situated to the edge of the PCB Full Set Exit Time Option No 9 Allows the Exit Time for full set to be programmed Part Set Exit Time Option No 10 Allows the Exit Time for Part set to be programmed Setting Modes Option No 11 Allows the setting modes for Full and Part set to be programmed Part set Sounders amp Output 1 Mode
3. Option No 12 Allows the Part set exit sounder mode and the operating mode of the programmable output 1 terminal to be programmed Entry Time 1 Option No 13 Entry time may be looked at as three events Entry time 1 will give the normal Entry tone Entry time 2 will give a louder warning tone After both times have expired the external sounders will sound This option allows Entry Time 1 to be programmed Entry Time 2 Option No 14 Allows Entry Time 2 to be programmed Keypad Option No 15 Key numbers 1 amp 3 when pressed together may be programmed using this function to give a particular response Bell Re Arms Option No 16 This option is used to program the number of times the Bell will Re Arm during a set period Bell Ring Time Option No 17 This option is used to program the Bell ring time Page 12 a FUNCTION OPTIONS AVAILABLE DEFAULT 1 14 Zone1 Attributes LEFT DIGIT RIGHT DIGIT O Full Set 1 Part1 2 Part2 3 Part1 amp 2 4 Full Set Chime 5 Part1 Chime 6 Part2 Chime 7 Part 1 amp 2 Chime Zone 2 Attributes As Zone Options E Zone 3 Attributes As Zone1 Options 00 a aeons ea o 55 Sounder Level CHIME ENTRY EXIT LEFT DIGIT RIGHT DIGIT 0 9 0 9 poo Full Set Exit Time 00 99seconds Part Set Exit Time 00 99seconds Setting Modes FULL SET PART SET 22 LEFT DIGIT RIGHT DIGIT O Exit Term O Exit Term 1 E E Door 1 E E Door 2 Time 2 Time 3 Time E E 3 Time E E Bell Mode Option No 19 Gardtec 370 Met
4. open collector output held at 12V through an integral 1k resistor Max current sink into this terminal is 50mA This terminal is programmable for other uses if required PGM Options Pulse On Switch ve Pulse Off Bell Strobe Exit Entry Test Int Alarm A more detailed description is given in the programmable options description page 12 Power Supply Rating It should be noted that the Gardtec 370 has 1 Amp available for the full system Sounders detectors and other auxiliary items should be included when calculating current drawn by the system Any damage caused through over loading the Control Panel will not be covered by the warranty AUX 12V Terminals This pair of terminals supply the and supply for the keypads and detectors 1 Amp is available from these terminals see power supply rating above Strobe Terminals This pair of terminals are the output for the Strobe The negative terminal is switched during an alarm period A maximum of 1 Amp may be drawn from these terminals see power supply rating above Bell Terminals This pair of terminals are the output for the Bell or external sounder The negative terminal is switched during an alarm period A maximum of 1 Amp may be drawn from these terminals see power supply rating above Page 3 Initial Power Up When the Control Panel is powered up it will be either set or unset dependent on the state of the Control Panel when it was powered down The factory default stat
5. programma ble features to ensure your message gets across ProDigi Communicator 04 073 ProDigi AV Communicator 04 072 ProDigi AV Serial Communicator 04 071 Additional RKPs Gardtec 370 LED RKP 01 144 Gardtec 370 580 LED RKP 01 113 Gardtec 370 580 Contour LED RKP 01 147 Gardtec 370 580 Profile LED RKP 01 114 ACE RX 01 136 ACE TX Key Fob 01 130 Include RKP Zone Up to four RKPs may be fitted to the Gardtec 370 Control Panel ACE offers Setting Unsetting Part Setting amp Resetting via high security Infra Red keyfobs ACE is available as compact stand alone units which are fully compatible with the Gardtec 370 Control Panel Page 15
6. Gard lec RIS C O G R O U P The GardTec370 Range of Control Panels Installation Instructions RISCO Group UK Ltd Tel 0161 655 5500 Fax 0161 655 5501 Int Tel 44 161 655 5500 Fax 44 161 655 5501 Internet www riscogroup com e mail sales riscogroup co uk Technical Support Tel 0161 655 5600 Technical Support Fax 0161 655 5610 Mon Fri 08 30 1730 RISCO Group UK Ltd reserve the right to amend the software and features without prior notice INDUSTRY ASSOCIATION INVESTOR IN PEOPLE p i finni to on PR5032Rev1 2 Remote Keypads Up to four remote keypads may be fitted to the GARDTEC 370 control panel A four core connection will be required between the control panel data port and remote keypad s all keypads must be in a daisy chain format as shown in Fig2 below Note All RKP models have an EOL jumper with the exception of the 370 model which is supplied with an EOL resistor If only one RKP is used the jumper or resistor should be fitted in that RKP If more than one RKP is used the jumper or resistor should only be fitted to the last RKP in the line Note When using RKPs fitted with an Entry Exit zone only one may be used irrespective of the number of RKPs fitted This RKP zone will be Entry Exit with Chime allocated and will be indicated on the display as r1 Fig1 RKP Connection Note Terminal position will differ dependant on RKP model used Some models may also have dual ter
7. al The Bell Mode Function allows the mode of the Bell to be programmed from SAB to SCB In SAB mode the current for the sounder is supplied from the Control Panel unless the cable to the Bell box is cut In SCB mode the current for the sounder is supplied by the sounder battery under all circumstances The Bell Tamper mode if programmed ON will always trigger the external sounder from the control panel in the event of a Bell Tamper Page 9 Reset Modes Option No 21 The reset modes are programmed using this function Service Timer Option No 22 The service timer period is programmed using this function When service time expires the system will lock the user out Extra service may be gained using the Anti Code software If the timer is set to 99 weeks the timer function is Off Display Messages The Following System messages are possible 1 to 7 Represent zones 1 to 7 E System Full Setting t Tamper zone CA Alert keys activated E System Part 1 Setting EZ System Part 2 Setting E System Part 3 Setting Un System is Unset System Fully Set System Part 1 Set System Part 2 Set _ System Part 3 Set AL An Alarm has occurred Ac Anti Code reset required Fb Fuse Fail or Battery Fault Ct RKP Tamper bb Bell box Tamper Pc Mains Power Cut Cb Control Box Tamper r1 Keypad Zone PL Phone Line or Digi Fault En Engineer Reset required or Service Timer activated Page 13 Part Set Sounde
8. e will be unset As power is applied all segments of the twin seven segment display will be lit for approx six seconds During this period press 4 6 YES NO to ensure that the Control Panel is at factory settings The display will then show set or unset Reset to Default Modes Method 1 To gain temporary access to the factory default settings remove the link marked LK2 R S on the PC B this will give temporary access to the default codes 5678 for user and 1234 for engineer See note below Method 2 Apply power to the panel and press 00 within the first 5 seconds 1 Down power the panel again and leave for at least 10 seconds 2 Re apply either the mains or battery supply 3 Press 4 6 YES NO within the first 5 seconds The Control Panel is now back to factory defaults Note The two methods shown above will have no effect on the engineer code if it started with a 9 If this is the case only re use of the programmed engineer code will allow it to be changed System Programming The system may be programmed by the engineer by use of the engineer code 1234 factory default Other Engineer User functions are also available to the engineer these are as follows Set Unset Remove Test Log Chime Note Details of the above functions are given in the User Manual Program Engineer Code Programming of the Engineer Code is only possible via the Engineer Code e g 1234 See Engineer Programming Flow Chart overleaf Page 7
9. er the four digit source code given by the Panel 3 Enter the resulting four digit Anti Code into the Control Panel Zone Type Terminology The terminology used for the various zone types are explained in this section 12 Hour Zone active when Control Panel is Set Access Will allow to pass through on Exit Will allow to pass through on entry only if entry exit is opened first 24 Hour Internal sounder if Unset Full alarm if Set Entry Exit Zone used as last exit point or first entry point Part E E As Access if Control Panel is Full Set As entry exit if Control Panel is Part Set PA 24 Hour Personal Attack Active if Control Panel is Set or Unset Alert Internal sounder only Recorded to Log Fire Will give Fire alarm when activated pulsed external sounders with panel set or unset Exit Terminator With Panel programmed to set with exit terminator the panel will only set when zone is activated during exit Page 11 Other Accessories A complete range of accessories are available to complement your Gardtec 370 security system Some of this range is shown below Gardtec 370 Speaker Kit 01 087 A 32 Ohm speaker Rear Tamper 02 064 The Gardtec Speech Dialler 04 069 The Gardtec Speech Dialler offers communications between your security system and any telephone or selected pagers One Common message along with three Information messages may be programmed to be sent to up to four telephone numbers The unit offers a full range of
10. ers internal and external remote keypads mains etc The fixing of a 3 amp unswitched fused spur When fitting the RKP s consideration should be given to Operation of the keypad Readability of the display The Position of the underside flap retaining screw The Panel should be fixed to the wall using appropriate wall plugs and No 8 screws at least 30mm long Do not tighten the screws at this stage wait until all your wiring is in place Mains Supply Connection A 230V a c supply should be taken directly from the consumer unit In order to com ply with the requirements of B S 4737 this should be via a 3 Amp unswitched fused spur Page 2 Fig4 Typical Novagard 1E Connections Gardtec 370 Novagard 1E Fig5 Input Connections N C Devices N O Device N C Devices N O Device N C Devices N O Device N C Devices N C Tamper Switches N O Device N C Devices N O Device N C Devices A A we we A N O Device N C Devices N O Device Page 6 Output Terminal Descriptions Speaker Terminals This pair of terminals provide connection for Keypad Speaker s Optional 32 Ohm Panel Speaker Any Extension Speaker s A speaker is supplied in each keypad If any additional speakers are fitted they should present a minimum impedance of 16 Ohm PGM 1 Terminal This terminal provides the switch ve or set ve required by most types of latching detectors The terminal is an
11. minal markings N C E E Zone N C Tamper Note EOL jumper should be fitted only to last RKP in chain Note If 370 RKP is used 680 ohm resistor should be fitted between 12v amp D IN terminals on last RKP Note ACE RX should be configured as 581 IMPORTANT Ensure only 1 keypad has a EOL jumper or resistor fitted Page 4 IMPORTANT Input AC230V 10 50Hz 125mA Max 35W Max 0 50 C Gardtec 370 Range Metal Versions For Indoor Use Only Gardtec 370 Range Plastic Versions For Indoor Use Only This equipment is intended only for use as a Security Alarm Control Panel Adequate ventilation away from heat and humidity must be provided The unit must be fixed securely to a non flammable surface using suitable fixings All mains wiring must be to BS7671 1992 IEEE wiring regulations or appropriate international regulatory standards See Mains Supply Connection section within this manual for more detailed instructions All wiring must be protected from sharp or jagged edges All Low voltage alarm wiring must be to the appropriate international regulatory standards and comply to good wiring practice Replacement fuses should be of the same type and rating conforming to IEC 127 The maximum current draw from the unit for all output combinations must not exceed 1Amp The unit is intended for use with a suitable re chargeable lead acid battery permanently connected to the appropriate terminals All documenta
12. rs PART PROGRAMMABLE amp Output 1 Mode SOUNDERS OUTPUT1 PGM1 LEFT DIGIT RIGHT DIGIT O All Parts silent 0 Pulse On 1 Part 2 silent 1 SW 2 Parts1 amp 3 silent 2 Pulse Off 3 All Parts 3 Bell Audible 4 Strobe 5 Entry Exit 6 Test 7 Int Alarm baa FUNCTION OPTIONS AVAILABLE DEFAULT 12 Entry Time 1 00 99seconds Entry Time 2 00 99seconds Keypad ALERT KEYS 1 amp 3 LEFT DIGIT 0 Off Always 0 1 Panic 2 Fire 3 Alert RIGHT DIGIT 7 Bell Re Arms 00 Re Arms 99 Re Arms E Bell Ring Time 00 minutes 99 minutes Bell Delay 00 minutes 99 minutes Bell Mode BELL TYPE TAMPER RING LEFT DIGIT RIGHT DIGIT 0 SAB 0 Off 1 SCB 1 On PA Mode 00 Audible PA 10 Silent PA RESET MODE 0 LEFT DIGIT RIGHT DIGIT Always 0 0 Any Code 1 Master Code 2 Anti Code 3 Engineer Code Service Timer OOweeks 98weeks 99 Off p99 Page 10 31 30 10 10 20 1 Reset Modes Display Messages Log Apart from the System and Status displays the following messages may also appear whilst viewing the Log Ss System Full Set S System Part 1 Set sT System Part 2 Set so System Part 3 Set i 01 Unset User 1 02 Unset User 2 03 Unset User 3 04 Unset User 4 05 Unset User 5 06 Unset User 6 07 Unset User 7 08 Unset User 8 o9 Unset User 9 o0 Unset User 0 Engineer AL Alarm has occurred TE Watchdog reset 1 to 7 flashing Zone 1 to 7 was removed when system was set Gardtec 370 Specification
13. should be ON and the 581 SEL jumper OFF When you have finished programming the EOL jumper should be taken OFF and the 581 SEL jumper should be put ON Please refer to the ProDigi Installation manual for more details Fig2 ProDigi Connection Note ProDigi EOL jumper must be OFF ProDigi 581 SEL jumper must be ON RKP 2 etc ProDigi Communicator S A os 2 g 23 ou oO ES 2g 5 16 Ohm On os Min 2 oo gt EE 2 Sounder SAB Unit E O gt o 2 S o A Page 5 Introduction The Gardtec 370 Control Panel is a seven zone microprocessor based unit that has been designed to be suitable for domestic and small commercial installations All zones are fully programmable by the engineer Upon completion of the installation the engineer may if required re program several factory set options so as to tailor the Control Panel to suit the requirements of the system It should be noted that if a new four digit engineer code starts with a 9 it will be locked into the system and may only be changed by using the code again default to factory settings will have no effect We recommend that this engineer manual and the user manual are read and fully understood before any installation of the system is carried out Planning the Control Panel Location Consideration in locating the fixing position of the Control Panel should be given to Access for the routing of cables for the system from detection devices sound
14. tion and manuals must be thoroughly read by suitably qualified installation personnel prior to installation The unit has no user serviceable parts inside Internal access should only be by suit ably qualified personnel Gardtec 370 Metal Versions The unit must be Earthed It is the responsibility of the installation engineer to ensure that the earth connection to the unit lid is good on completion of the installation or after service Gardtec 370 Plastic Versions Provision is provided for an earth connection within the mains input connector block this connection is for protection of the wiring only and is not functional for the unit Battery Fuse An in line Battery Fuse has now been incorporated into this product The fuse rating is 2 Amp Anti Surge The fuse holder is spring loaded therefore you should ensure that the battery lead is not under tension in order to maintain a good connection between the fuse and the holder To change the fuse push the two halves of the holder together and twist anti clockwise Please ensure correct battery charge on completion of the installation and during each service visit Page 1 ProDigi Communicator Standard AV amp AV Serial It is possible to use a ProDigi Communicator with a Gardtec 370 Metal version Connection details for the ProDigi are shown below The ProDigi must be programmed via a Gardtec 800 Series control panel or a ProDigi Programmer When programming the ProDigi the EOL jumper