Overview Inspect Shipping Container Adding a Drive Safety Notes
Contents
1. NEO 8049m 5 Tighten the two captive retainer screws to secure the module to the library NEO 8049j 6 Ifthe removal and replacement was done with the library operational and the Auto Power up An Installed Drive After Timeout feature from the Library Options page is disabled reactivate the drive by selecting Menu gt Maintenance gt Replace Drive gt Reactivate Drive n NOTE LED on the rear of the drive should be green when initialized 7 Ifthe power was off during the procedure power on the library The drive will be reactivated during the power on initialization of the library 8 Refer to NEO 8000 User manual for cabling configuration examples Setting Setting a SCSI ID a SCSI ID For Native SCSI Drives Each SCSI configured tape drive installed in the library requires a unique SCSI ID The information provided in this section instructs you on how to set a SCSI ID To set a SCSI ID 1 With the Default screen displayed Figure 1 select the Menu option from the Default screen see Figure 2 2 Enter the appropriate password if required See the section on Front Panel and Media Locks in the NEO 8000 User manual on how to set passwords 3 Select SCSI FC in the Edit Options area to display the following screen see Figure 3 Cverland STORAGE NEO SERIES Figure 1 Edit Options m Touch scsi 0 Library sii sad Ps Drive 2 Bus ID
2. Qerland TOR AG E ALWAYS THERE Add On Instruction NEO SERIES 8000 Drive Shoe Assembly GETTING HELP You can get support via the Internet at www overlandstorage com or call Tech Support at 800 729 8725 Option 5 2004 Overland Storage Inc JUN 2004 Part Number 104339 101 Tape drives are mounted inside individual drive shoe assemblies at the rear of the library This allows the flexibility to remove or replace a tape drive while the other tape drives and library robotics remain active The SCSI connectors for the tape drives are part of a separate module and remain in the library when the tape drive is removed Visually inspect the shipping containers and notify your carrier immediately of any damage Place shipping container on a clean surface and carefully remove and verify the contents against the packing list If parts are missing or the equipment is damaged notify your representative Always save the containers and packing materials for any future reshipment Electrostatic Discharge Information A discharge of static electricity can damage static sensitive devices or micro circuitry Proper packaging and grounding techniques are necessary precautions to prevent damage To prevent electrostatic damage observe the following precautions e Transport products in static safe containers such as conductive tubes bags or boxes e
3. SCSI FC Network Passwords Utilities Maintenance Diagnostics Network Options Factory Library Security Info Level View System Data Library Options SCSI FC Options 2 Library SCSI Bus ID 6 Library SCSI Bus Parity Enabled i Prevent Allow Mail SlotAccess Command Inhibits Cartridge Map v Back Figure 2 Back Figure 3 NOTE You can move to the next sequential SCSI options screen by selecting the W To return to the previous SCSI options screen select the A The Back button to return you to the Menu screen 4 For example to set the Drive 1 Bus ID to 3 a Select the box next to the text Drive 1 Bus ID The Drive 1 Bus ID screen appears on the display see Figure 4 This screen displays the current Drive 1 Bus ID along with the new value that you request b Touch the block that contains the number 3 This places your request into the New data field c Touch the Save option to confirm your request A confirmation screen appears on the display see Figure 5 d Select OK to confirm The newly selected SCSI ID flashes for a few seconds while the drive is being updated then remains solid indicating that the operation is complete see Figure 6 Press the Back button repeatedly to return to the Main menu screen m Drive 1 Bus ID New Drive 1 Bus ID a Confirm Press OK to save new option NOTE Option cha
4. Keep electrostatic sensitive parts in their containers until they arrive at static free stations e Cover the library with approved static dissipating material Provide a wrist strap connected to the work surface and properly grounded tools and equipment e Keep the work area free of non conductive materials such as ordinary plastic assembly aids and foam packing e Make sure you are always properly grounded when touching a static sensitive component or assembly e Avoid touching pins leads or circuitry e Use conductive field service tools Cautions and Notes System power in the library does not completely shut off using the Graphical User Interface GUI touch screen You must turn off library power using the circuit breakers on the power strip and disconnect the AC power cord from the the power strip to completely remove all power from the library To reduce the risk of electric shock or damage to the equipment disconnect power from the library by unplugging the power cords from either the electrical outlet or the power strip Adding a Drive Shoe Assembly This instruction explains how to add a tape drive to a NEO 8000 library See your reseller or visit Overland s website for a list of tape drives supported by this library CAUTION With a blank panel or tape drive removed there Is access to moving parts DO NOT reach into open cavities VORSICHT Wenn eine Gehduseplatte oder ein Band Laufwerk entfernt wurde gibt dies Z
5. g the V see Figure 10 To return to the previous Drive Configuration screen select the A see Figure 11 Select the Back button to return you to the Menu screen
6. nge is effective Drive 1 Bus ID k Figure 4 immediately after saving Press Cancel to skip saving the new option Save Drive 2 Bus ID 2 Library SCSI Bus ID 6 Library SCS Bus Parity Enabled F Prevent Allow Mail Slot Access Command Inhibits OK conc Figure 5 Back 5 Repeat this procedure for each SCSI drive added Native Fibre Channel Drive Configuration Set Values NOTE The NEO SERIES 8000 library requires a minimum library firmware level of 2 01 to correctly operate with native fibre channel drives installed Verify the firmware level of your library by selecting Menu Library Info buttons from the default screen If the library does not meet the minimum firmware level requirements you can obtain the proper firmware level by selecting the SERVICE amp SUPPORT at Overland Storage s website www overlandstorage com In most cases you can use the default configuration values for the native fibre channel drives Changeable fibre channel drive configuration values are Port n Control Port n Loop Id World Wide Port n Name World Wide Node Name Topology Speed and Directory Registration Refer to the NEO 8000 User manual for a more detailed description on configuring these options To view the fibre channel drive configuration 1 With the Default screen displayed Figure 7 select the Menu option from the default screen see Figure 8 2 Ente
7. r the appropriate password if required See the section on Front Panel and Media Locks in the NEO 8000 User manual on how to set passwords 3 Select SCSI FC in the Edit Options area to display the Drive Configuration screen see Figure 9 Cverland STORAGE NEO SERIES Figure 7 Utilities Maintenance Diagnostics Network Options Factory Library Security Info Level Edit Options Library SCSI FC Network Passwords View System Data Library Options SCSIAFC Options Set Values a Drive 2 Configuration Set Values Library SCSI Bus ID 6 Library SCSI Bus Parity Enabled Mail Slot Access B isik f al z Cartridge Map Back Figure 8 Figure 9 Back 4 Select the Set Values button located ajacent to the Drive n Configuration to access the edit configuration values Figure 10 and Figure 11 Edit Drive Configuration World Wide Port 0 Name Default Edit Drive Configuration World Wide Port 1 Name Default World Wide Node Name Default Topdom Use Loop Allow eee Point to Point Speed 2 Gb sec Directory Registration No Port 0 Control Soft Address Port 0 Loop ld 0 Port 1 Control Soft Address Port 1 Loop Id 0 Save Al Save Cancel Figure 11 Y Cancel Figure10 NOTE You can move to the next sequential Drive Configuration screen screen by selectin
8. ugang zu sich bewegenden Teilen Greifen Sie NICHT in den Hohlraum NOTE Drives must be installed in sequence following the numbering adjacent to the drive bay opening 1 Remove the upper and lower retaining screws that secure the blank panel cover plate to the drive opening where you plan to install the new drive A 2 Keep the panel cover plate for future use 3 Fully support the Drive Shoe Assembly while starting it into the receiver being careful not to damage the tape drive or connectors NEO 8049k 4 Push the Drive Shoe Assembly slowly into the receiver until it seats against the back of the library
Download Pdf Manuals
Related Search
Related Contents
Minka Lavery 5472-562 Instructions / Assembly Assembly and User`s Manual Guide de démarrage rapide PODER JUDICIAL Departamento de Gestión Humana Análisis de Miststreuer ® Notice d`utilisation snappi snug user manual v9b GSM-Control Object User Manual V7 Ultra Protective Sleeve Manual Geral do Usuário Sikaflex®-15 LM SL Copyright © All rights reserved.