Home

English Manual

image

Contents

1. MAC Address IP Address Status Server Ma TRP C34H25 D0 50 C2 giis aE RST ocked erver Manager Ww Search Devices u i ui QE Add with IP Address server Monitor Locate E J Fort Monitor 9 DI Fort Mapping Ca m d Auto IP Address Report Load Factory Defa No Time Description i 29 11 2011 16 47 59 1 Devices Found Event Log Monoron Ready jc P3r11 2011 16 48 17 da By default all the devices searched are locked and can be seen under the status column of the Server Manager Window in order to protect from unauthorized configuration changes In order to configure the device it has to be Unlocked first Unlock password trycom After the device has been Unlocked the device can be configured for all Network Serial Operating settings Select the device to be configured Right Click on the selected device and click on configure to go to Configuration menu Double clicking on selected device can also open the Configuration menu B Serial Server Admin Utility loj xl File Function Server Manager View Help Server Manager Found 1 Device s allo Al i No Model MAC Address IP Address Status 1 0 50 c2 1b 70 40 192 168 2 35 Server Manager 8 Search Devices add with IP Address o Locate Server Monitor Unlock 5 p This invokes the Server Manager Configuration Dialog as shown below Accessible IPs Auto Warning IF Address Report Fasswo Basic Settings IF Set
2. Timeout 1 1280 0 0bps 8 bit Mane 1 bit Xoan Xoff R 2 1280 0 0bps 8 bit Mane 1 bit Xoan Xaoff R View Setting Select any Serial Port and click on the Settings tab which will show serial settings dialog where all parameters can be viewed in enabled state Serial Port Settings E mi 4 x Fort alias Modify Time Qut Baud rate 9600 Flow control xon Xoff T Parity None Interface Rs 232 Data bits Stop bits B Apply above settings to all selected ports OK Cancel Click the checkbox Apply Port Alias to all selected ports to apply same port alias to all selected ports Maximum length of Port alias is 5 characters Click the specific drop down box or click the check box to modify the serial port settings viz Baud Rate Parity Data Bits Stop Bits Flow control Interface If Serial applications like Hyper Terminal opens a COM Port with any of above port Numbers in a Virtual PC then the serial settings of that particular port change as per the Hyper terminal session opened Operating mode Click on Operating mode which opens the operating mode page as shown Server Manager x Accessible IPs Auto Warning IP Address Report Passwol Basic Settings IP Settings Port Settings Operating Mod Information Model Name v Modify TRP_C34H2S Pot Alias OP Mode 1 Real COM Mode e Real COM Mode MAC Address
3. 90 50 C2 1B 7F FF Serial Number 1 Firmware Version 1 26 11MAY11 Click the Modify check box to modify the configuration OK CANCEL Select any port and click on View Settings tab which shows the Operating Mode dialog Box as shown below The default operating Mode is Real Com Mode Note IRP C34X will restart automatically after configuring the Operating Settings page For all other pages TRP C34X will not restart If modify check box is checked to activate the parameter double click or highlight and click Settings tab of the specific port to modify the operating mode Click the Operating Mode drop down box to set the Real Com Mode TCP Server Mode TCP Client Mode UDP Mode as shown below Real COM Mode Key in the TCP Alive Check Timeout to set the timeout for TCP Alive time The Default setting is 7 min TRP C34X automatically closes TCP connection if there is no TCP activity for the given time After the connection is closed TRP C34X starts listening for another REAL COM driver s connection form another host TCP Server Mode a Local TCP Port The TCP Port of TRP C34X that uses to listen to the requests coming from Host Computers on Network in order to establish connection The Host Computers should contact this Port in order to establish connection with the TRP C34X b Click the Max Connection drop down box to set Max connection options to 1 2 23 4 c TCP Alive Check
4. lolx Fi 1 TRP C34HZ25 192 1868 3 22 1234 CONS Server Manager Te 9 2 TRP C34H25 192 1868 3 22 1235 CON server Monitor Ss AJ COM Port Configuration is applied Ok Fort Monitor 3 8 5 Fort Mapping Ca Auto IP Address Report Ready 29 1 D otep8 plug in RS232 LOOP back connector How to Test TRP C34X Trycom Technology Co Ltd offers test utility this is utilities may help user to demo and test TRP CO06 fast and easily User may find the utilities in Trycom support CD or download from Trycom web www trycom com tw direct to perform TRPCOM exe from the directory STEP9 Run the TRPCOM EXE utility STEP10 Click the Setting to set the com port and baud rate inen ss OK v IRPCOM 2013 Test Utility Communication Configuration Initial Setting coma 9600 Communication Protocal v ASCII C Modbus RTU Default Exit ASCH Checksum Enable Description TRPCOM utility is designed ta test TRP Series modules In the settings menu be sure to select the ASCII Modbus protocal cam part parameters from the drop down menus and selecting Checksum Selects Enable ar Disable before continuing Please note COM 2 is an example of COM port number the real COM number is assigned by user PC STEP11 Click the Terminal then select Loop back enable the counter value and pass value will be synchronized counts EM TRPCOM Test Utility Terminal Command Input se
5. DNS Server 1 When the user wants to visit a particular website the computer asks the Domain Name System DNS Server for the websites correct IP address and the computer uses the response given by DNS Server to connect to the Web Server DNS is the way that Internet Domain Names are identified and translated into IP address f DNS server 2 An optional alternative of DNS Server g Community Name A community name is a plain text password mechanism that is used to weekly authenticate queries to agents of managed network devices h Contact The SNMP contact information usually includes an emergency contact name and telephone or pager or Mobile number i Location This string is usually set to the street address where the TRP C34X is physically located Port Settings Page On the Port Settings page of the Server Manager dialog displays all the serial ports present on the Serial Server model of the selected device It also shows the corresponding serial settings in the settings column of the page In order to see the current settings of any Serial port select the port number in above window amp then click on View settings To modify the serial settings check the modify box on the serial page Then View settings tab would be converted into Settings tab as below Accessible IPs Auto Warning IF Address Report Passi Basic Settings IF Settings Fort Settings Operating Ma Modify Port Alias Settings
6. Isolation 3KV gt COMB RS232 Driver gt RS232 Data Baud Rate Auto Detector RS422 485 Transcelver Surge Protector FLASH8MB 8MB 32MB 32MB SDRAM qom COMA lt gt lt gt 32 BIT us ARM 2 2 Panel layout and Dimension mm Unit Notice User can only choose either external DC Jack or Screw terminal DC input Do not use DC Jack and screw terminal DC input simultaneously 2 2 LED indicators PWR LED Blinking Not Ready ON TRP C34X Ready LINK LED Ethernet cable connection and data active TX RX LED COMA RS422 485 Transiting Receiving Indicator COMB RS232 Transiting Receiving Indicator DC Jack Power Input DC 10V to 30V Pleas use the 5 5 2 1mm DC JACK 2 3 Factory default Push the factory restore button till the PWWR LED off and then reboot Hardware Setting COMA Auto Switching RS422 485 COMB RS232 Unlock Password trycom Model Name TRP C34H 2S Basic configuration Accessible IFs Auto Warning IF Address Report Basic settings IF Settings Fort Settings Modify Server Mame Modify Enable Modify Time Fone GMT 05 30 India Local Date HN HIE S Local Time Timeserer Modify Enable Web Console Enable Telnet Console IP setting Accessible IPs Auto Warming IF Address Report Basic Settings IF settings Port Settings Modify IP Address Madify Met Mask Gateway IP Configuration e Ls DNS Serverl D
7. Port Mapping view Help a um Ad server Manager server Monitor Le Fort Monitor Bs 4 Port Mapping E Auto IF Address Report Port Mapping 0 Port s Model IP Address TCP Part COM Number Enable Disable l Fort Settings Apply Change Discard Change ini ge Export Fort Mapping wa Import Port Mapping File Function Port Mapping Vie Help aum Mal g Server Manager a server Monitor Pp Ho Port Monitor Port Mapping Ca Auto IP Address Report Port Mapping 2 Port s Model IP Address TCP Port COM Number TRP_C34H25 192 169 3 22 1234 COMS TRP_C34H25 192 168 3 22 1235 COME eo Too pray Step7 Right Click select Apply Change i Serial Server Admin Utility Fie Function Port Mapping View Help Port Mapping 2 Port s Model IP Address TCP Port COM Number TRP C34H25 1392 188 3 22 1234 COMS TRP C34H25 132 188 3 22 1235 CONO Server Monitor MS Add Device emove Devic Port Monitor Remove Device Enable a Disable BEES Capp T Te Port settings 3 Apply Change Auto IP Address Discard Change I PODES at Export Port Mapping 4 dl a Import Fort Mapping Ready e _ 129 lif 4 otep7 The TRP C34X Real COM Mode setting OK Notice No matter how to change Add device or Remove Device its need to be run Apply change for save COM Port configuration Fe Serial Server Admin Utility File Function PorthMapping View Help
8. TRP C34X Application Diagram TCP or Real COM Mode n m q comans 77 y ra Ethernet PLCE __ evator COMB RS232 55 CNC Canti Paired Mode COMA RS422 485 wW COMA RS422 485 QUBBANMNM as RS232 COMB RS232 Sire aerei Client Server 1 Serial Device to 4 TCP Host PC at Same Time Broadcase COMB RS232
9. Timeout Default setting is 7 min d Inactivity Timeout Default setting is 0 gt Disabled O 99 min 0 65535 ms TCP Client Mode a Click the Connect Mode drop down box to set Startup Any character b Setting Destination IP address 1 and Port Number allows TRP C34X to connect actively to the remote host whose address is set by this parameter c Similarly Destination IP addresses 2 3 4 allows TRP C34X to connect actively to the remote hosts whose address is set by this parameter d TCP Alive Check Timeout Default setting is 7 min e Inactivity Timeout Default setting is 0 gt Disabled Operating Mode Operating Mode TCP Client Mode TCP Client TCP Client Mode Settings Connect Mode Start Up m Destination Host Misc Optional 1 192 168 2 36 Bom TCP Alive check Timeout 2 i 4001 0 99 min 3 3 4001 Inactivity Timeout 4 4001 o D 65535 ms DK Cancel UDP Mode a Local Listen port The UDP port that uses to listen to Data from multiple host computers and also to multicast data to multiple host computers UDP Mode Setting Destination Destination IP address 1 2 3 4 eratin ode Operating Mode UDP Mode Local listen Port 4001 LIDP Mode Setting Destination Begin End 1 19268 2 36 192 168 2 6 Accessible IP s Page Accessible IP settings allow
10. you to add or remove legal remote host IP address to prevent unauthorized access to TRP C34X Hosts that are included in this list can only access the TRP C34X on the network JUGOGOOSUHOSOUO On Accessible IP s page click the modify box to activate the parameter Click on settings button to enter the IP Address and Net Mask of remote host that control the TRP C34X You can allow one of the following cases by setting the parameter gt Only one host of specific IP address can access the TRP C34X Enter IP address 255 255 255 255 e g 192 168 2 246 255 255 255 255 gt Hosts on the specific subnet can access the TRP C34X Enter IP address 255 255 255 0 e g 192 168 2 0 255 255 255 0 Any host can access the TRP C34X Disable this function by unchecking the Enable Check Box Refer the following table for more details about the configuration example Allowable Hosts Input format Any host Disable 192 168 2 246 192 168 2 246 255 255 255 255 192 168 2 1 to 192 168 2 254 192 168 2 0 255 255 255 0 192 168 0 1 to 192 168 255 254 192 168 0 0 255 255 0 0 192 168 2 1 to 192 168 2 128 192 168 2 0 255 255 255 128 192 168 2 129 to 192 168 2 254 192 168 2 128 255 255 255 128 Auto Warning Page Auto warning mechanism is a useful mechanism which sends the status messages to E Mail id s and Trap Servers in order to warn or acknowledge the changes made to the TRP C34X Basic Setti
11. A RS422 485 COMB RS232 TX D RS232 Device 4 How to configure TRP C34X There are 3 ways to access the TRP C34X a Serial Server Admin Utility Serial Server Admin Utility Fo Function Server Manager View Help Server Manager Found 1 Device s adi Mo O O Model MAC Address IP Address Status 1 TRP_C34H25 00 50 70 2 1B 7F FF 192 1568 0 117 Locked server Manager E server Monitor o Be Pd Port Mapping F Auto IP Address Report i gt Description 1 29 11 2011 17 27 02 1 Devices Found Event Log Manitar Lon Ready 29 120111652552 4 b WEB Server E Serial Server Web Console Microsoft Internet Explorer aoe rale http 1192 168 3 oto sen Taflenamessd tibene inos um www trycom com tw ciMain menu l ii Welcome to Serial Server S web console MBasic Settings Model Name I Network Settings MAC Address Serial Settings Serial No NENNEN Firmware version 4 26 11MAY11 Moperating Settin CiAccessible IP Settings Serial Server is a 2SP Device MaAuto Warning i oc rovi t ina f i iem ess This web console provides the following function groups LChange Password Basic Settings CJLoad Factory Server name real time clock time server IP address and web console Telnet console Enable Defeuit disable function DUpgrade Network Settings CiSave restart IP address netmask default gateway static IP or
12. AS Server Modify Enable SNMP Community Mame public Location Contact E Modify Subnet 2 Fasswo Uperating Mod Fasswol Operating Modi Port Setting COMA COMB 115200 8 N 1 Operating Mode Real Com Mode Accessible IPs None Setting Auto Warning None Setting IP Address Report None Setting Password Factory trycom 2 4 Push Button If lost the password or wrong setting user can keep push button till the PWR LED off and then reboot back factory setting 3 Installing TRP C34X Hardware STEP1 Connect the power source from DC Jack or screw terminal the PWR LED will blinking wait till PWR LED ON STEP2 Connect TRP C34X with Ethernet port by RJ45 cable If the cable is properly connected the LINK LED will light up The TRP C34X Supports Auto MDIX A straight through or crossover RJ45 cable can be used to make a connection directly to the HUB Router PC LAN port STEP3 Connect TRP C34X to RS232 by AWG 1112 30 wires Connect TRP C34X to RS422 485 by AWG 12 30 twisted wires 3 1 RS485 Wiring The RS 485 mode supports the Transmit and Receive channels use twisted pair wire half duplex operation db RS485 Slave Device RS485 Slave Device TX D d RX RX 3 2 RS422 Wiring The RS 422 mode supports 4 channels with full duplex operation use dual twisted pair wire half duplex operation 3 3 RS232 Wiring Refer to the Pin out table for connections COM
13. Go B Serial Server Admin Utility is l EU m Jes lolx File Function Server Monitor wiew Help server Monitor Stopped el Md No Alive IPAddress Model MAC Address Motalizo 192 1 fara Sars pam ERHO Server Manager bic Device al m E i Remove Device Load configured Forts Server Monitor a EE 5 e Fort Monitor 5 pue gt Fort Mapping z Auto IF Address Report Ready 1 1 2002 05 20 53 E S otep5 Connect PC COM Port link TRP C34X COMA CONMB otep6 RUN Demo exe and select correct baud rate and data format Step7 RUN Telnet exe and input IP and Port x 89ABCDEFGHI JKLMNOPGRSTUUWXYabcdeoRy ut 00000000 put 00000000 SSABCDEFGHI JKLMNOPOQRSTUUWAYabcded SSABCDEF GHI JKLMNOPORS TUUWAYabcded SSABCDEFGHIJKLMNOPORSTUUWAYabcded ut 00000000 put 00000000 89ABCDEFGHI JKLMNOPARSTUUWKYabede 0 i 89ABCDEFGHI JKLMNOPORSTUUWXYabcde Md 5 3 Paired Mode Paired Mode COMA b COMB Client Example Paired Mode COMA COMA Port 4001 Destination IP 192 168 3 24 4001 lt o TRP C34H TRP C34H pua COME Ethernet Destination IP 192 168 3 24 4002 4 lt lt Port 4002 COMC DI Destination IP 192 168 3 24 4003 i Port 4003 COMD Client Server COMD pi Destination IP 192 168 3 24 4004 w gt 192 168 3 22 192 168 3 24 4 gt Operating TCP Client Mode Operat
14. TRP C34X 32 Bit Ethernet to 1 RS232 and 1 RS422 485 Optical Isolated Converter User s Manual Printed OCT 2013 Ver 1 2 Trycom Technology Co Ltd Tel 886 3 3503351 Fax 886 3 3503352 Web www trycom com tw Copyright Copyright Notice The information in this manual is subject to change without notice to improve reliability design and function and does not represent a commitment on the part manufacturer No part of this manual may be reproduced copied or transmitted in any form without prior written permission by the manufacturer Products mentioned in this manual are mentioned for identification purposes only In this manual product names appearing may or may not be registered trademarks of their respective companies or copyright 1 Introduction TRP C34X RS232 422 485 Serial Server provides a transparent way of connecting Serial devices over Ethernet It can transmit data between the Serial and Ethernet interfaces bi directionally To establish automatic or remote data acquisition TRP C34X Serial Server also provides 3KV optical isolation and surge protection to protect system from ground loops and destructive By specifying the IP address and the TCP Port number a host computer can access different Serial Devices such as Serial Thermometers Magnetic CNC Controller Elevator Data Acquisition Systems POS Terminals Industrial PCs etc over the Network you can centralize serial Device management and distribute the management
15. click Port1 Port2 item same below Server Manager x Accessible IPs Auto Warning IP Address Report Passwol Information Basic Settings IP Settings Port Settings Operating Modi Model Name SerialServer4S OP Mode TCP Server Mode TCP Server Mode TCP Server Mode MAC Address TCP Server Mode 00 50 C2 1B 7F 22 Serial Number a Firmware Version 1 24_15NOV10 View settings Settings Click the Modify check box to modify the configuration OK CANCEL a Port 1 Setting Gn mam Dm RAN PTT ZZZ TTT TT TET FT T T TT TFT FTT TET FAT FT FTT INNI LIA III RAI EV SI SIUE NT ER II t t mte ste e Ni Rt va a operating Mode Operating Made TCP Server Mode Mops TCP Server Mode Settings Max Connection Misc Optional TCP Alive Check Timeout 0 99 min Inactivity Timeout 0 65535 ms 101 5 b Port 2 Setting Operating Mode Operating Mode Top server Made TCP Serer TCP server Mode settings Local TCP Port Max Connection Misc Optional TCP Alive Check Timeout 0 99 min Inactivity Timeout o 0 65535 ms Hop ci i DUS Es DEES Hi z EEEE E EE di i Ts d Ji dr sE ca ar Step6 Keep the TRP C34X Server in LAN Also keep the Client PC in LAN Step7 Power ON the TRP C34X Server and wait till it completely boots PWR LED ON first otep8 Power ON the TRP C34X Client and wait
16. dynamic IP DNS SNMP IP location report MLogout Serial Settings Baud rate parity data bits stop bits flow control interface Operating Settings Operation mode TCP alive check inactivity Accessible IP settings aff Accessible IP or Accessible IP group Disable to accept all IF s connection c Telnet PEZ ar 192 168 3 22 Model Name TRP_C34H2S MAC Address 80 50 C2 1B TF FF Serial Number Firmware Version 1 26_11MAY11 lt lt Main Menu gt gt Basic Settings Network Settings Serial Settings Operating Settings Accessible IP Settings Auto Warning Settings Monitor Ping Password Settings Load Factory Defaults Ulew Settings Saue Restart Quit our selection 4 1 Installing Serial Server Admin Utility The Serial Server Admin Utility Support WIN XP VISTA 2003 Server 2008 Server 32 64 bit 2000 Server Win 7 Insert the TRP Serial CD find the TRP C34X s folder Utility and run PortSetup exe When Installation is completed the wizard creates a Serial Server Admin Utility shortcut on the Desktop as shown below Serial Server Admin Utility Double Click on the Serial Server Admin Utility then Right click on the main window or go to Server Manager in Menu Bar and select Search Devices to find the TRP C34X on the network serial server Admin Utility C E l uc MM ji lolx Fie Function Server Manager View Hep Server Manager Found 1 Device s ul m r r Ali 2 Model
17. e PC In the Basic Settings page of Windows Configuration Utility if the Enable Telnet Console check box is enabled we can use the Telnet Console to modify the device parameters Go to Start Menu Run Run Telnet from remote pc with the IP address of TRP C34X as shown below Type the name of a program Folder document or 1 Internet resource and Windows will open it for you 5 Application 5 1 Real COM Mode TRP C34X Basic 2 Real COM Port installs COMA Pihamet lt gt RS422 485 COMB gt RS232 Host PC Example Step1 Connect PC RJ45 TRP C34X RS232 422 485 Device Step2 Run Serial Server Admin Utility and Right Click on the selected device and click on configure to go to Configuration menu Step3 Be sure IP Setting Port Setting and Operating Mode is correct Server Manager x Accessible IPs Auto Warning IP Address Report Fasswnol Basic Settings 1 IP Settings 2 Port Settings 3 Operating Modi Information Model Name v Modify m TRP C34H25 Pun AES OP Mode Real CON Mode e Real COM Made MAC Address 00 50 C2 18 7F FF Serial Number 1 Firmware Version 1 26 11MAY11 Ar ew setings Click the Modify check box to modify the configuration OK CANCEL Step4 Select Port Mapping then right clicks Add Device gn TUE WIENER a t EEUU V Ei iii Serial Server Admin Utility File Function
18. ed Host on Network Auto direction RS485 flow control by hardware Virtual COM drivers for WIN 32bit XP Vista 2003Server 2008 Server 32 bit amp 64 bit 2000 Server OS Win 7 32 bit amp 64 bit Fully compatible with Ethernet and TCP IP protocol Power Link and 2 pair Serial RX TX mode LED indicator Support screw terminal and standard external DC power adapter Din rail or panel mounts support Features Specification CPU 32 bit 170MHZ with MMU SDRAM 32MB FLASH 8MB Power Input Voltage DC 10V to 30V LAN Auto MDIX 10 100 Mbps Auto detecting RS 232 TXD RXD RTS CTS ISO GND RS 422 TX TX RX RX ISO GND RS 485 Data Data ISO GND Data Rate 5 921Kbps Parity none even odd Data Bits 5 6 7 or 8 Stop Bits 1 1 5 or 2 Configuration through Windows Admin Utility Web Console Telnet Console Supports Real COM mode using RFC 2217 protocol Protocol ICMP TCP IP UDP DHCP Boot Telnet DNS SNMP HTTP SMTP SNTP Power supply Screw terminal or standard external DC adapter Serial interface 15 KV ESD RS422 485 interface Surge over current over voltage protection Power consumption 12V 230 mA without external device Operating Temperature 0 to 65 C Humidity 0 90 Non Condensing Dimensions 141 L 78 W 26 5 H mm Weight 450g W Packing Hardware Description 2 1 Block Diagram die DC sem PLS DC DC Converter sem PLS A Optical
19. entering the correct password and click submit Default Password is trycom E Serial Server Web Console Microsoft Internet Explorer i i ial x Fie Edit View Favorites pei L Qu Ox z dy sere fone LA Address http 192 168 3 22 cge bin script cgi session 18flename database 18formno 1 El Go Links di mm www trycom com tw OMain menu on Sp Welcome to Serial Server s web console 3 Basic Settings Model Name TRP_C34H2S Network Settings MAC Address 00 50 C2 1B 7F FF C3Serial Settings Serial No 1 Operating Settings Firmware version _ 1 26_11MAY11 Accessible IP EM settings Serial Server is a 2SP Device C3Auto Warning This web console provides the following function groups Settings Change Password Basic Settings OLoad Factory Server name real ime clock time server IP address and web console Telnet console Enable Default disable function C3Upgrade Network Settings CA3Savelrestart IP address netmask default gateway static IP or dynamic IP DNS SNMP IP location report ClLogout Serial Settings Baud rate panty data bits stop bits flow control interface Operating Settings Operation mode TCP alive check inactivity Accessible IP settings Accessible IP or Accessible IP group Disable to accept all IF s connection 4 H Done TIT bien 4 3 Telnet TRP C34X implements a Telnet Server and can be invoked by making a Telnet from remot
20. ing TCP Server Mode Step1 Run Serial Server Admin Utility and Right Click on the selected device and click on configure to go to Configuration menu otep3 Be sure IP Setting Port Setting and Operating Mode is correct Step4 TRP C34X Client setting Select Operating Mode and then double click Port1 Port2 item same below Server Manager mure x Accessible IPs Auto Warning IF Address Report Fasswnl Information Basic Settings IP Settings Port Settings Operating Modi Model Name SerialServer4s TCP Client Mode TCP Client Mode TCP Client Mode MAC Address TCP Client Mode loo 50 c2 1B F 02 Serial Number se Firmware Version 1 24_15NOV10 Sew setings settings Click the Modify check box to modify the configuration OK CANCEL a Port 1 Setting Operating Mode Operating Mode Top Client Made TCP Client TCP Client Mode Settings Connect Mode Start Up Destination Ho 192 Misc Optional 158 TCP Alive check Timeout f 0 99 min Inactivity Timeout 0 65535 ms b Port 2 Setting Operating Mode Operating Mode Top Client Mode TCP Client TCP Client Mode Settings Connect Mode Start Up Destination Host Misc Optional TCP Alive check Timeout i 0 99 min Inactivit Timeout i 0 65535 ms otep5 TRP C34X Server setting Select Operating Mode and then double
21. nd Command ABCDEF GHIJKLMNOP RSTUVIAKYZ1 234567590 Response Instruction Send I Auto fen ms Clear 58 Checksum E Command Checksum ABUCDEFGHIJISLMBNOPGRSTUNNVVRS 212345579090 Loop Back Test Counter PASS I Ense EX m o Description The Termial Function Test Rodeo send the command and get R405 device response J Test RSZ3Z2 M ZZ RSZ3260with hardware control or RS4Z27 loop back wiring Step 12 User also test RS422 loop back Please same above step Demo setting RTS CTS item need to Disable for test RS422 COMA RS422 485 COMB R3232 DC 10 30V 5 2 TCP Server Mode COMA RS422 485 COMA RS232 Each Port Maxium Connection 4 Host PC at same time Example Step1 Connect Host PC 1 8 Ethernet TRP C34X PC Step2 Run Serial Server Admin Utility and Right Click on the selected device and click on configure to go to Configuration menu otep3 Be sure IP Setting Port Setting and Operating Mode is correct Accessible IPs Address Rapar Passati Information Bm cSetegs 1 isetinge 2 Porsetige 3 Operating Moc Madel Nama TRP C34H25 Mac Address 16 50 C2 1B 7F FF Sena Humber 1 Fame ara Version 1 26 _11MAYII Chck the Modify check box to modify the configuration ak CANCEL Step4 Select Server Monitor then right clicks Add Device Step5 Select
22. ngs IP Settings Port Settings Operating Mode Information Accessible IPs Auto Warning IP Address Report Password E Mail and SNMP Trap Settings Event Model N RENE e dall Iv i Modif SerialServer 165 GENRES Mail Server From E Mail ddress To E Mail Address 1 GC MAC Address 00 50 C2 1B 70 40 i To E Mail Address 2 ToEMal ddess3 To E Mail Address 4 CT Modify Firmware Version 1 20 21Aug Click the Modify check box to modify the configuration OK CANCEL On Auto warning page under E mail and SNMP Trap Setting Tab click the modify box to activate the parameter a On Mail server frame input the IP Address or Domain Name of the Mail server b Input the From E mail Address c Enter the email addresses in the To E Mail address boxes 1 2 3 4 to whom the acknowledgement has to be sent d If the Mail Server has to be authenticated check the Modify box and check the Mail Server authentication check box and then press Setup button e Input the User Name and Password to modify the Mail Server Authentication Setup f To set or modify the Trap Server check the Modify checkbox and enter the IP Address or Domain name of the Trap Server to which the Auto warning are to be sent Server Manager x Basic Settings IP Settings Port Settings Operating Mode Information Accessible IPs Auto Warning IP Address Report d E Mail and SNMP Trap Settings Eve
23. nt Model Name Vv Modify Serials erver 165 Mail Server From E Mail Address To E Mail Address MAC Address 00 50 C2 1B 70 40 To E Mail Address To E Mail Address To E Mail Address 1 20 21Aug Trap Server Click the Modify check box to modify the configuration OK CANCEL On Auto warning page under Event Tab click the Modify box to activate the parameter and click the checkbox to set the Events for which Auto warnings are to be sent E Mail and SNMP Trap Settings Event Modify Cold Start Warm Start Authentication Failure IP Address Changed Password Changed To get Auto Warning E Mails i Give the Mail Server IP address amp authentication if required ii Give from ID amp To ID iii Select on what event you want to be notified by mail in Eventtype page To get Auto Warning Trap Messages i Key in the IP address of the Linux Machine Trap server option ii In Network settings page enable SNMP and provide community name contact and location information iii Run this command on Linux PC snmptrapd f Le iv Select the event type which you want to be notified v On that event notice that some messages will get printed on the console where you are executing the above snmptrapd command IP Address Report Page Network management becomes difficult when TRP C34X is forced into DHCP Any IP changes due to DHCP in TRP C34X a
24. re reported to the assigned Host on the Network Basic Settings IP Settings Port Settings Operating Mode Information Accessible IPs Auto Warning IP Address Report P d Model Name SerialServerl6S MAC Address 00 50 C2 1B 70 40 1 20 21Aug Click the Modify check box to modify the configuration OK CANCEL On IP address Report click the modify box to activate the parameter and set the IP address Port number and time period to Auto report to host Basic Settings IPSetings PortSettings Operating Mode AccessblelPs Auto Waring PAddesRepot Password M Modify Auto Report to 192 168 2 36 4002 Auto Report Period fo 0 99 sec Click the Modify check box to modify the configuration OK CANCEL The default Port number is 4002 and the default Auto Report Period is 10 s Password Password can be set modified amp Disabled through this screen Maximum length of 7 characters can be supported for TRP C34X password Alpha Numeric amp Alpha numeric type of passwords are supported opace is not allowed between any characters in password 4 2 using the WEB Server mode TRP C34X support web console for remote configuration of the TRP C34X on the network To view the web console open any web browser eg Internet Explorer and type the IP address in the address bar of the browser A login form prompting for password appears Login to the web console by
25. till it completely boots PWR LED ON Step9 Connect PC COM Port link TRP C34X Client COMA CONMB by Cable Step10 Plug in TRP C34X server COMA COMB by loop back connector Step11 Run the TRPCOM EXE utility otep12 Click the Setting to set the com port and baud rate then press OK Fey TRPCOM 2013 Test Utility 1020928 Pali Communication Configuration Initial Setting coma 9600 Communication Protocal ASCII C Modbus ATIJ Default Exit TRPCOM utility is designed ta test TRP Series modules In the settings menu be sure to select the ASCII Modbus protocal com port parameters ASCH Checksum Enable Description from the drop down menus and selecting Checksum Selects Enable ar Disable before continuing Please note COM 2 is an example of COM port number the real COM number is assigned by user PC STEP11 Click the Terminal then select Loop back enable the counter value and pass value will be synchronized counts EZIRPCOM Test Utility Yersion 2013 Q3 e yf xj Terminal Command Input send Command ABCDEF GHIJKLMNOP RSTUVIAKYZ1 234567590 Instruction Response ABCDEFGHUKLMNOPORS TU A1 234567 090 Clear E Checksum E Command Checksum Loop Back Test The Termial Function Test Rodeo Send the command and get R405 device response 2 est RSZ32 M ZZ RSZ3260with hardware control or RS4Z27 loop back wiring 6
26. tings Fort Settings Operating Mod Modify Server Mame try carr E Modify Enable Inactivity Time Seconds Modify Time Zane GMT 05 30 India Local Date Local Time Timeserver Modify Enable Web Console Enable Telnet Console On Basic page check the Modify check Box to change any of the Configuration details IP Setting Accessible IPs Auto Warming IF Address Report T Basic Settings IF Settings Fort Settings Operating Modi Modify IP Address Modify Met Mask Gateway IP Configuration DAS Serverl DAS Server Modify Enable SNMP Community Mame public Location Contact Madify Subnet z On IP Settings Page click the modify box first you can modify all the Network parameter IP address Net Mask Gateway Click the IP Configuration drop down box to modify the parameter Static DHCP BOOTP o o0ocwm x AccessblelPs AutoWaming IPAddessRepot Password Information Basic Settings IP Settings Port Settings OperatingMode UE Model Name IP Address 192 108 2 3 SerialServerl6S M Modify Net Mask 255 255 255 0 Gat 4 i MAC Address ateway 192 168 2 1 00 50 C2 1B8 70 40 IP Configuration static Firmware Version 1 20_21Aug Click the Modify check box to modify the configuration OK CANCEL e
27. to different hosts at the same time TRP C34X makes possible to access distant Serial Devices over Network as if they were directly connected to the Standard COM Port of a Personal Computer TRP C34X supports different modes of operation allowing user to operate the system in different environments Real COM Mode TRP C34X comes equipped with COM drivers that work with Operating Systems WIN 32bit XP Vista 2003Server 2008 Server 32 bit amp 64 bit 2000 Server OS Win 7 32 bit amp 64 bit The driver establishes a transparent connection between host and serial device by mapping the IP Port Number of the TRP C34X s Serial Port to a local COM Port on the host computer The important point is that Real COM Mode allows users to continue using RS 232 422 485 serial communications software like HyperTerminal and similar applications TCP Server Mode In TCP Server mode TRP C34X provides a unique IP Port address on a TCP IP network TRP C34X waits passively to be contacted by the host computer allowing the host computer to establish a connection with and get data from the serial device This operating mode supports up to 4 simultaneous connections so that multiple hosts can collect data from the same serial device at the same time TCP Client Mode In TCP Client mode TRP C34X can actively establish a TCP connection to a pre defined host computer when serial data arrives After the data has been transferred TRP C34X can automaticall
28. y disconnect from the host computer by using the TCP alive check time or Inactivity time settings This Operating Mode supports establishing the TCP connection up to 4 Destination Hosts UDP Mode Compared to TCP communication UDP is faster and more efficient In UDP mode you can multi cast data from the serial device to multiple host computers and the serial device can also receive data from multiple host computers making this mode ideal for message display applications When TRP C34X working at unstable voltage industrial environment the hardware circuit detection can prevent the power fail cause of the boot fail and Re Boot 1 1 Features Wide input range DC power supply RS232 422 485 Built in 3KV Optical Isolation Surge protection and over current and over voltage on RS 422 485 data lines Supports Socket operation modes like TCP Server TCP Client and UDP using TCP IP and UDP protocols Support Auto MDIX twisted pair crossover detection and auto correction Each Port maximum connection 4 host PC at TCP Server and TCP Client Mode Maximum allowed bandwidth is 460 Kbps per Serial Port Supports Web Console Telnet Console Runs in Stand Alone Mode Built in Restore Factory default push button Features Accessible Imps List to add or remove legal remote host IP Addresses to prevent unauthorized access to TRP C34X Features Auto IP Address Report to periodically report the IP Address of TRP C34X to the assign

Download Pdf Manuals