Home
USER MANUAL
Contents
1. 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequential or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has bee
2. firmly see Figure 5 Screw the locking butterfly screws downward until tight against the mounting bracket Figure 5 Installing TBUS 9 Installing the TBUS 9 Table Connection Bus 5 4 Connecting the Cables To connect the cables 1 Insert the power cable into its appropriate connector from below see Figure 6 2 Insert the other cables through the split grommets removing the split brackets if necessary to route the cables 3 Secure the cables to the tie holes using the included self locking ties Do not secure the cables too tightly or too loosely Leave a small amount of slack After the unit is connected to mains power and the proper cables it is ready for use Figure 6 Connecting the Cables KRAMER SIMPLE CREATIVE TECHNOLOGY Technical Specifications 6 Technical Specifications TBUS 9 technical specifications are shown in Table 3 Table 3 TBUS 9 Technical Specifications POWER SOURCE Universal 4 100 240V AC 50 60Hz 5A AC power limits USA 100 240V AC 50 60Hz 5A UK 100 240V AC 50 60Hz 5A Germany and EU 100 240V AC 50 60Hz 5A Belgium and France 100 240V AC 50 60Hz 5A South Africa 100 240V AC 50 60Hz 5A Australia 100 240V AC 50 60Hz 5A FUSE RATING T 6 3A 250V OPERATING TEMPERATURE RANGE 5 to 45Deg C OPERATING HUMIDITY RANGE 10 to 90 RHL non condensing STORAGE TEMPERATURE RANGE 20 to 70Deg C STORAGE
3. includes the following items e TBUS 9 Table Connection Bus e 2 table clamps e Power cord e 6 self locking ties e Cut out template e 4screws for holding template e This user manual 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables 1 GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters GROUP 11 Sierra Products 2 We recommend that you use only the power cord supplied with this device 3 Download up to date Kramer user manuals from our Web site http www kramerelectronics com 4 The complete list of Kramer cables is on our Web site at http www kramerelectronics com 1 Getting Started 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps Step 1 Cut an opening in the table see section 5 1 Cut out an opening in your table using the cutout template Step 2 Adjust the height Step 3 Remove the of the connecting rubber guard and insert surface see section 5 2 the unit se
4. rim during shipping Remove before installing unit Figure 3 and Table 2 define the connecting surface Figure 3 TBUS 9 Connecting Surface Table 2 TBUS 9 Connecting Surface Features Feature Function Split Brackets Support the split grommet for the pass through cables Split Grommets Push apart slightly to insert cables Power Socket Power socket for PC or other device 1 Some versions may not include tie holes Installing the TBUS 9 Table Connection Bus 5 1 Installing the TBUS 9 Table Connection Bus To install TBUS 9 perform the following steps 1 2 3 4 Cut an opening in the table see section 5 1 Adjust the height of the connecting surface see section 5 2 Install TBUS 9 in the cut out opening see section 5 3 Connect the cables see section 5 4 Cutting an Opening in the Table To cut an opening in the table 1 Place the included cut out template on the surface of the table where you want to install TBUS 9 Attach the template to the table with the included screws Following the inside edge of the template cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 4 not to scale Note The thickness of the table should be 3 inches or less 158 2mm 123 2mm Figure 4 Cutout Dimensions 4 Unscrew and remove the template from the surface of the table and clean the table s
5. 900 000559 REV 1
6. Beware of sharp edges on the inner and outer rim of the mounting plate and on the lid of TBUS 9 Do not place heavy objects on top of the TBUS 9 Your TBUS 9 Figure 2 and Table 1 define the unit Figure 2 TBUS 9 Table Connection Bus Top View KRAMER SIMPLE CREATIVE TECHNOLOGY Your TBUS 9 Table 1 TBUS 9 Table Connection Bus Features Feature Function 1 Connecting Surface See Figure 3 and Table 2 2 Anodized Lid Covers the connecting surface leaving the table surface neat and tidy 3 Mounting Plate Outer Rim Fits over the table surface 4 Enclosure Inserts into the table cutout 5 Height Adjustment Screws Eight screws for adjusting the height of the connecting surface two on each panel 6 Rubber Protectors Protect the table surface when mounting the unit one on each side T Locking Butterfly Screws Tighten to lock the mounting butterfly screw one on each side 8 Mounting Brackets Fit in the bracket slits after inserting the enclosure into the table to secure the unit to the table surface one on each side 9 Mounting Butterfly Screws Tighten to secure the unit to the table surface one on each side 10 Tie Holes Anchor the self locking ties to secure the pass through cables to the inside walls of the unit 6 pairs of holes 3 pairs on the front and 3 pairs on the rear panel 11 Protective Rubber Guard Protects the mounting plate outer
7. HUMIDITY RANGE 5 to 95 RHL non condensing DIMENSIONS Top plate 176mm x 140 4mm 6 9 x 5 5 W D Enclosure 136mm x 102mm x 130mm 5 4 x 4 0 x 5 1 W D H WEIGHT TBUS 9 0 9kg 2 0lb approx Table clamps 0 25kg 0 6lbs ACCESSORIES Power cord table clamps self locking ties template template screws 1 Specifications are subject to change without notice 2 The Universal socket is fully compatible with power plugs in UK India Italy Denmark and the 2 prong Europlug 3 The Universal socket is partially compatible polarity is reversed with plugs in China Switzerland Israel and USA The Universal socket does not supply grounding to plugs in Central Europe and France Order country specific sockets instead 4 The Universal socket does not fit South African plugs LIMITED WARRANTY Kramer Electronics hereafter Kramer warrants this product free from defects in material and workmanship under the following terms HOWLONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorized K
8. Kramer Electronics Ltd USER MANUAL Model TBUS 9 Table Connection Bus Contents Contents 1 Introduction 2 Getting Started 2 1 Quick Start 3 Overview 4 Your TBUS 9 5 Installing the TBUS 9 Table Connection Bus 5 1 Cutting an Opening in the Table D2 Adjusting the Height of the Connecting Surface 5 3 Installing TBUS 9 in the Cut Out Opening 5 4 Connecting the Cables 6 Technical Specifications Figures Figure 1 TBUS 9 Table Connection Bus Figure 2 TBUS 9 Table Connection Bus Top View Figure 3 TBUS 9 Connecting Surface Figure 4 Cutout Dimensions Figure 5 Installing TBUS 9 Figure 6 Connecting the Cables Tables Table 1 TBUS 9 Table Connection Bus Features Table 2 TBUS 9 Connecting Surface Features Table 3 TBUS 9 Technical Specifications V AJA A Y vaa ONAN YW Un Un Introduction 1 Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by function Thank you for purchasing the Kramer TBUS 9 table connection bus which 1s ideal for boardrooms conference and training rooms The package
9. e section 5 3 Step 4 Secure the unit Step 5 Connect the to the table cables see section 5 4 see section 5 3 2 KRAMER SIMPLE CREATIVE TECHNOLOGY Overview 3 Overview The Kramer TBUS 9 is a high quality anodized aluminum table mounted connection bus for boardrooms and conference rooms Its attractive enclosure is designed to provide maximum connectivity in the smallest possible footprint The unit is sturdy cost effective and easy to install TBUS 9 includes e Four pass through holes for connection cables e One power socket available in 7 versions USA UK Germany EU Belgium France South Africa Australia and Universal for use anywhere TBUS 9 is height adjustable and the cover opens and closes manually keeping the cables and the connectors out of sight when not used To achieve the best performance e Use only good quality connection cables to avoid interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality e Position TBUS 9 away from moisture excessive sunlight and dust Figure 1 TBUS 9 Table Connection Bus 1 See compatibility restrictions in the Specification section 6 2 Available from Kramer Electronics on our Web site at http www kramerelectronics com 3 Your TBUS 9
10. n tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and light industry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and light industry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION B gt Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment BO Use the supplied DC power supply to feed power to the machine B Please use recommended interconnection cables to connect the machine to other components FCC and CE approved using STP cable for twisted pair products 10 KRAMER SIMPLE CREATIVE TECHNOLOGY For the latest information on our products and a list of Kramer distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Safety Warning Disconnect the unit from the power supply before opening servicing Caution 9001 o lt g lt a jg Institute of Quality amp Control Kramer Electronics Ltd Web site www kramerelectronics com E mail infoOkramerel com P N 2
11. ramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectronics com 2 Any product on which the serial number has been defaced modified or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removalor installation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL PAY FORAND WHAT WE WILLNOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center
12. urface Take care not to damage the table If needed you can download a full scale template from our Web site 1 At http www kramerelectronics com KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the TBUS 9 Table Connection Bus Kramer Electronics is not responsible for any damage caused to the table 5 2 Adjusting the Height of the Connecting Surface If needed you can adjust the connecting surface to one of four possible heights to accommodate large or bulky cables By default the height is set to the second level from the top To adjust perform the following 1 Remove the eight height adjustment screws two screws on each side as shown in Figure 2 while supporting the surface from underneath with your fingers Raise or lower the connecting surface to the required height insert the screws and tighten them in place 5 3 Installing TBUS 9 in the Cut Out Opening To install TBUS 9 in the opening 1 Remove the protective rubber guard from around the outer rim of the mounting plate Beware of the sharp edge Carefully insert the unit into the prepared opening see Figure 5 Take the support brackets under the table and place them into the support bracket grooves on both sides of the unit see Figure 2 Verify proper alignment of the unit before tightening the mounting screws Screw both mounting butterfly screws upward until they reach the table surface from underneath Tighten
Download Pdf Manuals
Related Search
Related Contents
GE WCRD2050DWC User's Manual Massive Ceiling light 70568/40/31 USB Station 2 User's Guide DeLOCK 82902 Qilive Q.4670 mobile headset Boss Car Stereos Installation Instructions Componentes de frenos neumáticos para vehículos remolcados Bersaglio 116694B RL4000 & TML-4000 Service Manual Copyright © All rights reserved.
Failed to retrieve file