PWMC402 User Manual - Applied Processor and Measurement, Inc.

image

Contents

1. cycle PWM signal with a 10Hz carrier frequency 12V OV 80 msec m 100 msec Figure 4 1 1 1 PWM Controller Low Side Drive Output and Duty Cycle Definition 4 1 2 PWM Output Maximum and Minimum Duty Cycle Limitations The Model 402 PWM Controller utilizes embedded software algorithms and timer counter modules within a microcomputer to digitally create the output PWM signal Due to the oscillator stability and repeatability of the timer counter design the frequency and duty cycle values over the operating range of the PWM Controller 10 to 1500 Hz 0 1 duty cycle resolution are very accurate However due to the nature of the processing and requirement to change the duty cycle in real time the fixed period of time required to process changes becomes noticeable at higher frequencies of operation This prohibits the capability of the PWM Controller to output very low or very high duty cycles In most PWM solenoid control applications this is not an issue since operating at 1 duty cycle is typically not useful Due to the processing time inherent in the PWM Controller timing algorithms duty cycles out of the range of possible operation are forced to be either 0 or 100 depending on the value The minimum and maximum operating duty cycles for various operating frequencies are provided in the specification table in Section 2 0 The limits are specified for the maximum operating res
2. minimum 4 5 maximum 95 5 Frequency Crystal Oscillator Circuit 18 432 MHz 50 ppm stability Source Input Power Nominal 12V DC external source Model 402R range of operation 9 to 28V DC 20 mA typical Model 402T range of operation 9 to 14V DC 120 mA typical Dual supply required for operating loads outside this range RS 232 TX RX GND 9600 baud no parity 8 data bits 1 stop bit Operating limited by enclosure 40 C to 60 C Temp electrical components are industrial temperature range Environmental Lead Free RoHS p PWM Controller output positive connection OUT see note 1 ee PWM Controller switching output open drain power OUT MOSFET switches load from open to IN system ground Notes 1 The positive output is internally connected to a protective diode see figure 4 1 3 0 Installation and Start up This section provides information on how to connect the PWM Controller for operation and provides start up instructions Section 3 1 provides a Quick Start Installation intended to provide an easy step by step procedure to connect and start using the Model 402 PWM Controller PWMC 402 3 1 PWMC 402 Quick Start Instructions Use the following steps to start using the PWMC 402 1 Connect the PWMC 402 as shown in one of the installation diagrams in section 3 3 The connection depends on the load voltage and the type of load Use the descriptions in section 3 2 for guidance
3. query command Oscilloscope best method of observing the output The change in frequency and duty cycle may be observed and measured Frequency Counter will be able to measure the output frequencies Some DMM s have frequency and duty cycle measurement capability 20 DMM setting the DMM to measure DC Volts will provide some average value of voltage that will allow you to conclude that the PWM Output is not stuck high or low Changing the duty cycle should change the DMM value displayed In conclusion do not attempt to service the PWM Controller internally The methods provided above give a visual indication of operation of the unit This indication is intended to isolate problems with your application of the PWM Controller to the unit itself or the system connection 5 4 Software Upgrades Updates The PWM Controller contains in circuit programmable microcomputer based circuitry and software Applied Processor and Measurement Inc is committed to supplying a high quality product and will issue new software releases which will enhance capability and maintain the software When purchasing the PWM Controller your unit will be automatically registered This registration will allow you to receive notices and pricing information on software releases and new software versions containing operational enhancements and new features The PWM Controller software is capable of being upgraded for the life of the unit Watch our websi
4. 0 APM c 2009 gt Using the serial command functions see section 4 2 set the desired frequency and duty cycle If it is desired that the PWMC 402 powers up at a certain frequency and duty cycle use the save command to store the desired values in EEPROM The next time power is applied to the controller the frequency and duty will be restored from EEPROM 3 2 PWM Controller Installation WARNING FOLLOW THE INSTALLATION INSTRUCTIONS CAREFULLY TO AVOID POSSIBLE DAMAGE TO THE PWM CONTROLLER TO YOUR LOAD DEVICE OR SYSTEM UNDER CONTROL REMEMBER TO PROPERLY SELECT ALL WIRE SIZES FROM THE POWER SOURCE TO THE PWM CONTROLLER OUTPUT AND TO THE DEVICE UNDER CONTROL IN ORDER TO MINIMIZE HAZARDS AND TO PROVIDE A SUITABLE RETURN PATH FOR INDUCTIVE LOADS This section provides installation instructions and figures which illustrate typical connections for the PWM Controller and the device to be controlled Figure 3 3 1 shows connection of the PWM Controller to a single device using a single power supply which sources current for both the PWM Controller and the device under control This figure illustrates the low side drive connection of the PWM Controller Also note that because of the open drain output an external connection must be added between the positive terminal for the power input and the positive terminal on the output of PWM Controller This connection also utilizes the PWMC 402 internal inductive kickback protection diode Figu
5. WARNING NOTE THAT THE FACTORY DEFAULT SETTINGS FOR THE OPERATING FREQUENCY IS 100 HZ AND THE OPERATING DUTY CYCLE IS 0 BE SURE TO CHANGE THIS AS NECESSARY BEFORE APPLYING THESE SETTINGS TO THE OUPTUT LOAD Table 4 6 1 below specifies the factory default settings for the configurable parameters in the PWM Controller Parameter Factory Default Sample RS 232 Command s Setting Operating Frequency 100 Hz H100 Table 4 6 1 PWM Controller Configuration Default Settings The PWMC 402 start up settings are set using the H and D commands and are saved using the E command 19 5 0 Warranty and Service 5 1 Warranty The Model 402 PWM Controller is warranted for 1 year from the time of purchase This includes workmanship and manufacturer defects It does not include failures caused by misuse 5 2 Service WARNING OTHER THAN FUSE REPLACEMENT OR DIODE JUMPERING THERE ARE NO USER SERVICEABLE PARTS INTERNAL TO THE PWM CONTROLLER DO NOT ATTEMPT TO SERVICE THE UNIT COMPONENTS INTERNAL TO THE PWM CONTROLLER ARE STATIC SENSITIVE AND MAY BE DAMAGED WITHOUT PROPER HANDLING The PWM Controller requires no maintenance or calibration If you detect a malfunction with your unit obtain a Return Authorization RA Number from the Applied Processor and Measurement Inc website Information on how to have your unit serviced the shipping address and service policies are shown on the website You must obtain an RA number for either warranty o
6. internal S2BA diode across the output terminals to suppress inductive current kick back from the load under test see the PWM Controller Block Diagram in figure 4 1 1 for details on the diode connection The S2BA is a general purpose rectifier diode and suits most needs when working with inductive loads such as valve solenoids and relays similar to using a 1N4001 If your application uses another type of diode the S2BA may be easily removed from the circuit and your diode may be installed on the PWM Controller externally across the and output terminals attach cathode to anode to The PWM Controller comes from the factory with the jumper diode installed Before removing the diode jumper consult section 3 2 and 3 3 to see if an installation configuration that does not connect the diode OUT terminal on the PWMC 402 can be used If this is not possible or practical the diode may be removed from the output circuit by removing a jumper in the PWMC 402 To remove the diode from the output circuit carefully snap open the unit A black shorting jumper JP1 is present on the circuit board near the PWMC I O connector J2 just above the corner of the fuse holder To remove the S2BA from the output circuit simply remove the jumper The PWM Controller contains static sensitive circuitry be sure to handle the unit so as to avoid touching any other circuitry on the circuit board and pins or connectors on the circuit board Store the jumper for l
7. power for the PWM Controller clean especially when the power supply is a great distance from the load and the controller Multiple loads may be connected to the PWMC 402 output provided the output MOSFET power rating is not exceeded This connection is shown in figure 3 3 4 Ifthe device is a resistive load or a solenoid with a built in diode the OUT connection on the PWMC 402 is not required A dual power supply example of this connection is shown in figure 3 3 5 Similarly the OUT connection may also be eliminated in single supply configurations Figure 3 3 6 and 3 3 7 illustrate connections to provide a PWM signal using the PWMC 402 Since the output is open drain a load resistor may need to be used This is shown in figure 3 3 6 Be sure not to exceed the voltage rating on the device input If the device contains its own pull up the connection in figure 3 3 7 may be used The PWMC 402 uses a standard 3 81mm screw down pluggable terminal block for the I O connection Replacement part numbers are provided below The components are rated for 8A Manufacturer Part Number Phoenix 1803594 AMP 284507 4 Table 3 2 1 Output Terminal Block Part Numbers 3 3 Connection Diagrams Host Computer PC Power Supply PWM Controller RS 232 Input Output UOO Device Under Control Figure 3 3 1 PWM Controller Single Supply Connection Host Computer PC Power Supply PWM
8. unit NEVER open the unit while it is operating Do not attempt to substitute parts or modify the system internally 1 0 Introduction This manual describes the features installation and operating procedures for the Model 402 Pulse Width Modulation Driver Controller PWM Driver PWM Controller or PWMC The Model 402 Pulse Width Modulation Driver Controller generates a variable pulse width modulated electrical switching signal The product is used in many industrial situations where valves solenoids actuators magnetic mechanical elements or other devices requiring a pulse width modulated signal are applied and or tested Model 402R PWM Driver Controller Figure 1 0 1 Model 402 PWM Controller The PWM Controller contains microcomputer based circuitry which allows for precision generation of the output frequency and duty cycle The PWM Controller is controlled via an RS 232 serial interface Single letter ASCII based commands allow the duty cycle to be set and displayed This capability allows the PWM Controller to be controlled by a host computer serial port e g PC compatible under program or manual control The PWM Controller output is an open drain power MOSFET output This provides low side control of the load to be pulse width modulated An external power source must be provided which may be used to power both the load and the PWMC This provides maximum flexibility since the load voltage can be set by the user using
9. Controller 12V DC 1 to 32 V DC Input Output Device Under Control Figure 3 3 2 PWM Controller Dual Supply Connection 10 Host Computer PC Power Supply PWM Controller 1to 32 V DC Input Outpu External Device AC DC O Under Adapter G Control 12V DC Figure 3 3 3 PWM Controller Dual Supply Connection additional example Power Supply PWM Controller Input Output Devices Under Control Figure 3 3 4 PWM Controller Testing Multiple Loads 11 Host Computer PC Power Supply PWM Controller 1to 32 VDC Input Output Device Under Control External AC DC G Adapter G 12V DC Figure 3 3 5 PWM Controller Dual Supply Connection diode internal to PWMC402 not used Host Computer PC Power Supply PWM Controller Input Output Device Figure 3 3 6 PWM Controller Connecting as a Signal Generator Using an external pull up 12 Host Computer PC Power Supply PWM Controller Input Output Device Input with internal pull up resistor Figure 3 3 7 PWM Controller Connecting as a Signal Generator Device contains internal pull up 13 3 4 Fusing WARNING BE SURE TO FUSE THE PWM CONTROLLER PROPERLY IN ORDER TO AVOID POSSIBLE DAMAGE TO THE PWM CONTROLLER TO YOUR LOAD DEVICE OR SYSTEM UNDER CONTROL WHEN CHANGING THE FUSE BE SU
10. ES NO LIABILITY FOR THE FAILURE TO COMPLY WITH THE SAFETY RECOMMENDATIONS PROVIDED IN THIS MANUAL INTENDED USE The Model 402 Pulse Width Modulation Driver Controller is intended to be used in a laboratory industrial automotive passenger compartment environment It is not intended for use in or in conjunction with any medical or life support appliances devices or systems Other than automotive passenger compartment applications the device is not designed for outdoor use Applied Processor and Measurement Inc assumes no liability from the use of this design in this context Applied Processor and Measurement Inc does not assume any liability for the malfunction of electronic components contained in any of its products nor any damage incurred from the improper use of the product to the user product or any connecting equipment GROUND THE SYSTEM Even though the Pulse Width Modulation Driver Controller requires an external DC source care should be taken that the total system is properly grounded Use only power supplies that have three conductor AC power cable with the grounding wire properly connected to an electrical safety ground This will minimize shock hazards DC POWER ONLY The Pulse Width Modulation Driver Controller requires a nominal external DC source of 12V DC Do not connect the Pulse Width Modulation Driver Controller directly to 120 or 240 V AC DO NOT SERVICE THE UNIT Do not attempt to service the
11. Note that the PWMC 402 may be powered from the same power supply as the load Be sure to stay within the operational ratings of the PWMC 402 The PWMC 402R operational range is 9 to 28 V DC while the PWMC 402T is 9 to 14V DC A dual supply configuration may be used for extending the operating voltage of the load For applications assistance contact customer support at www appliedprocessor com Check that the internal fuse rating is suitable for your application The factory installed fuse in the PWMC 402 is rated at 4 Amps This is sufficient to protect the PWMC 402 output stage in most 12V solenoid load applications If you need to protect your load or your application is not 12V a proper fuse should be installed Consult the section on Fusing in this manual section 3 4 This paragraph contains information on selecting the fuse as well as information on the fuse part numbers used in the PWMC 402 product A standard mini blade fuse is used available in most hardware and automotive parts stores Connect the PWMC 402 to a host computer such as a PC and open a serial port communication application such as HyperTerminal For HyperTerminal set it up as follows Select the appropriate COM port Set PORT settings Bits per second 9600 Data Bits 8 Parity None Stop Bits 1 Flow Control None Power on the PWMC 402 unit using the power supply The following message will appear on the HyperTerminal connection PWMC402 Control Program rev 0
12. R gt Command Notes Description set the output duty cycle to xxxx where xxxx 0 1000 1 count 0 1 duty cycle report current output duty cycle set the output frequency to xxxx where xxxx 10 1500 Hz 1 Hz resolution from 10 to 1000 Hz 50 Hz resolution from 1000 to 1500 Hz will auto coerce to nearest valid setting report current output frequency save current configuration saves current frequency and duty cycle for next power on set the output frequency same as the H command used for Model 205 compatibility report current output frequency query read back current settings reports current operating frequency and duty cycle indicates output status open load or blown fuse report PWMC 402 system information serial number software revision and hardware revision help Commands are not case sensitive Invalid commands are ignored Do not insert spaces when typing commands Backspace will erase any characters entered to the beginning of the line All RS 232 commands are via standard ASCII characters The serial interface is set for 9600 baud no parity 8 data bits 1 stop bit and no hardware handshaking 18 4 4 PWM Controller Configuration When the PWM Controller is powered on the parameters of PWM output are initialized to settings contained within the EEPROM configuration memory of the PWM Controller microcontroller system The user is able to configure these initial power up settings
13. RE THAT THE PWM CONTROLLER IS NOT CONNECTED TO ANY POWER SOURCE The PWM Controller contains a built in output fuse for device load protection and for the PWM Controller output MOSFET electronics itself The input fuse is connected in series with the load and the output Power MOSFET see the PWM Controller Block Diagram in figure 4 1 1 for details on the fuse connection therefore the fuse will protect both the PWM output drive circuitry as well as the device load in use The fuse is a standard mini blade fuse and is located on the same side as the output terminal block The fuse is socketed for easy replacement Fuse part numbers are provided in the table below Be sure to fuse the PWM Controller properly based on the current draw of the device load under test Refer to table 3 4 1 for maximum recommended fuse ratings for different voltages Operating Voltage Maximum Fuse Littelfuse Part Number Recommended 5V 4A 297004 WXNV 12V 4A 297004 WXNV 15V 3A 297003 WXNV 24V 2A 297002 WXNV Table 3 4 1 PWM Controller Maximum Recommended Output Fuse Ratings and Fuse Part Numbers Mini blade fuses are available from electronics component distributors and catalog vendors as well as from hardware and auto parts stores The fuses are also available from APM Inc See our website at www appliedprocessor com for ordering information on PWM Controller accessories 3 5 Internal Diode The PWM Controller possesses an
14. USER S MANUAL MODEL 402 PULSE WIDTH MODULATION DRIVER CONTROLLER DOCUMENT NO 00092 23 Applied Processor and Measurement Inc NOTICE The information contained within this manual has been carefully checked and is believed to be accurate and up to date Applied Processor and Measurement Inc operates under the guidance of quality standards which include activities governing continuous improvement Applied Processor and Measurement Inc may in the future make changes to this product or this manual without notice to improve the product reliability performance function or design Please refer to our website at www appliedprocessor com for product updates software revisions and hardware revisions Customers are welcomed to use the forms on the website to contact Applied Processor and Measurement Inc at any time for information on their product version potential future versions or customizations of the product for your particular application Copyright July 2009 by Applied Processor and Measurement Inc All Rights Reserved REVISION HISTORY E 7 2 09 Initial Release SAFETY SUMMARY THE FOLLOWING GENERAL SAFETY PRECAUTIONS MUST BE OBSERVED DURING OPERATION AND INSTALLATION OF THIS PRODUCT FAILURE TO COMPLY WITH THESE PRECAUTIONS AND WARNINGS HERE AND ELSEWHERE IN THIS MANUAL VIOLATES THE SAFETY STANDARDS OF DESIGN MANUFACTURE AND INTENDED USE OF THIS PRODUCT APPLIED PROCESSOR AND MEASUREMENT INC ASSUM
15. any variable bench top power supply or it can derive power directly from the system under control provided the controller is operated within the rated specifications The operation of the PWM Controller is configurable User programmable configuration options are available to set the power up state of the PWM Controller the output frequency and duty cycle 1 1 Features The following is a summary of the feature set of the Applied Processor and Measurement Inc Model 402 PWM Driver Controller e user computer adjustable pulse width modulated output switching signal 0 to 100 duty cycle e fixed frequency operation configurable by user in 1 Hz steps from 10 to 1000 Hz or in 50 Hz steps from 1000 to 1500 Hz e duty cycle adjustable in 0 1 steps using RS 232 commands e PWM output provides low side load control e Power MOSFET output PWM output sinks up to 4 amps at 12 volts e fused output using standard mini blade fuses e controller operates from same power source that powers the load an external power source nominal 12V DC must be supplied also supports a dual supply configuration allowing load voltages up to 32V e input power reversal protection controller circuitry protected by resettable polyfuse e inherent PWM monitoring monitors for open load monitors for open output fuse e configurable controller can power on at preset frequency and duty cycle e available with a non isolated or an electrically isolated RS 232 interfa
16. ater use 14 4 0 Operation This section describes operation of the Model 402 PWM Driver Controller In addition to describing the theory of operation of the PWM Controller the configuration command interface for the PWM Controller is discussed 4 1 Theory of Operation All operations of the PWM Controller including the generation of the pulse width modulated output signal are controlled by a highly integrated microcomputer circuit A block diagram of the Model 402 PWM Driver Controller is shown in figure 4 1 1 RS 232 Driver amp RS 232 Receiver see Note 1 Microcomputer VIN 5V Regulator VIN OUT PWM Output Monitor S2BA Diode jumper OUT i Output Driver Z Fuse d Power MOSFET Note 1 Optional opto isolated RS 232 interface available Figure 4 1 1 Model 402 PWM Driver Controller Block Diagram 15 The PWM Controller output timing is based on a crystal oscillator which drives timer counter resources internal to the microcontroller Using the RS 232 command interface the frequency and duty cycle are set The microcontroller calculates signal timings based on the frequency of operation and the duty cycle setting The PWM output timing is controlled by timer counter resources internal to the microcomputer A power MOSFET output transistor provides an open drain current sink fo
17. ce Model 402R non isolated Model 402T electrically isolated e temperature range 40 C to 60 C operation e high reliability single multi layer circuit board construction using surface mount technology 1 2 Applications The Model 402 PWM Controller was specifically designed for driving electromechanical devices requiring a PWM control signal such as solenoid valves or other electromechanical controls with solenoids or inductive loads The Model 402 PWM Controller is also suitable for generating a PWM signal to drive electrical devices that are controlled by a low level PWM signal 2 0 Specifications and Pinout Output Power Open Drain Power MOSFET Pd max 50 watts at 25 C Output Current Example Output Current 100 duty cycle 4A at 12V maximum at 25 C Power must not exceed maximum Pd Output Voltage Must use dual power supply configuration for voltages not 1V minimum within PWM Controller Input range 32V maximum Frequency 10 to 1000 Hz adjustment resolution of 1Hz max error lt 0 05 Hz 1000 to 1500 Hz adjustment resolution of 50 Hz Duty Cycle 0 to 100 adjustable in 0 1 steps typical error lt 0 1 minimum and maximum duty cycle based on frequency 0 to minimum gt output duty cycle is forced to 0 maximum to 100 gt output duty cycle is forced to 100 50 Hz minimum 0 2 maximum to 99 8 100 Hz minimum 0 5 maximum 99 5 500 Hz minimum 1 5 maximum 98 5 1000 Hz minimum 3 0 maximum 97 0 1500 Hz
18. ibility lt gt Table 4 2 1 PWM Controller Remote Port Command Summary In the summary table and the command listings that follow the carriage return is shown as lt CR gt Note that character positioning is important do not add extra spaces or punctuation Characters may be entered in uppercase or lowercase characters All numeric values shown are ASCII character representation of numbers that is the number 100 is actually three ASCII characters 1 0 and 0 All numbers are represented in base 10 The end of the command line signals to the microcomputer software to process a change in the duty cycle output The new duty cycle output is synchronized to the start engagement portion of the PWM output cycle by the microcomputer embedded firmware A synchronous system design could be realized by using a host system that would sample the PWM output engagement edge then output a serial command to the PWM Controller At 9600 baud a command will take over 6msec to send Considering processing time a maximum synchronous rate one update per PWM output cycle of approximately 80 to 100 Hz should be attainable Detailed descriptions of the Model 402 PWM Driver Controller are provided in the table that follows 17 PWMC 402 Command Descriptions Command Format Dxxxx lt CR gt D lt CR gt Hxxxx lt CR gt H lt CR gt E lt CR gt Fxxxx lt CR gt F lt CR gt Q lt CR gt I lt CR gt lt C
19. olution of the PWM Controller 0 1 For example if the PWM carrier frequency is 100 Hz the operating duty cycle is limited to 0 5 to 99 5 When operating at 100 Hz if the command issued to the PWM Controller results in a duty cycle output 16 request of 0 2 the PWM Controller will force the output to 0 Likewise any command that would request a duty cycle greater than 99 5 would force the output to 100 This is a limitation of the Model 402 PWM Controller and the microcomputer timer counter processing For applications that require a greater frequency greater resolution capability or no minimum maximum limitation on the operating duty cycle the Model 205 PWM Controller is recommended 4 2 PWM Controller Operational Commands Features of the PWM Controller are controlled via a command set that is ASCII character based All commands are terminated by a carriage return Return Enter Key on your keyboard ASCII value of 13H A summary of all Model 402 PWM Controller commands is shown in table 4 2 1 Operating Commands Dxxxx lt CR gt set duty cycle to xxxx 0 1000 D lt CR gt read current duty cycle Hxxxx lt CR gt set frequency to xxxx 10 to 1500 Hz H lt CR gt read current frequency Q lt CR gt read back current settings E lt CR gt save current settings to EEPROM I lt CR gt report system information lt CR gt help Bio ik set and read frequency same as H command included for PWMC 205 compat
20. r non warranty service There is a minimum service charge for non warranty service This number must appear on the outside of a suitable shipping carton or on the packing list Applied Processor and Measurement Inc will repair or replace the unit at its option If the return is for non warranty repair you will be notified of any applicable charges prior to work being performed Applied Processor and Measurement Inc may be contacted as follows Applied Processor and Measurement Inc 716 741 1141 716 741 1142 support appliedprocessor com www appliedprocessor com 5 3 Diagnostics The PWM Controller is a signal generator therefore any test equipment used to detect or measure signals may be used to check the PWM Output If it appears that you are still in communication with the PWM Controller but you are in doubt of the PWM Output simulate your load by connecting a resistor across the output using the configuration shown in figure 3 3 1 Connect your test equipment across the negative terminal on the PWM Output to ground the negative terminal on the power input Depending on the level of diagnosis desired any of the following methods may be used to determine whether the PWM Controller is generating an output signal Check the Output Fuse the output fuse may have been blown See section 3 1 on replacing the internal fuse Note that the PWM Controller may report a blown fuse via the serial communication status command Q
21. r the device under control This MOSFET output stage is fuse protected to prevent damage to the MOSFET and or the output load being driven The PWM Controller includes an internal diode for suppressing back currents from inductive loads This diode may be removed from the circuit by removing a jumper in order to easily accommodate user diode configurations other than a S2BA The microcomputer is also interfaced to a PWM output monitor circuit to verify output switching at the load Discrepancies are reported via a serial command 4 1 1 PWM Output Duty Cycle Definition Note the open drain output configuration with respect to the control of the load shown in the block diagram in figure 4 1 1 When the digital output of the internal microcontroller is logic low the MOSFET is off and the device load receives no current When the microcontroller bit is high the MOSFET is turned on allowing current to pass through the load to ground The PWM Controller actuates the load in this manner using the MOSFET as a low side control element Consider the signal shown in figure 4 1 1 1 The figure illustrates a 10 Hz PWM signal as would be seen by attaching a scope between the Output Negative terminal and ground When the signal is 12V the load is not engaged and no current is flowing When the signal is OV the MOSFET is on and current is being driven through the load Based on the above discussion of low side drive the signal shown represents a 80 duty
22. re 3 3 2 shows the recommended connection for a dual power supply connection This configuration would be used for a load whose operational voltage is not within the PWM Controller operating range The output of the unit may operate at any voltage from 1V to 32V within the recommended power specifications see Section 2 The controller may be powered using a nominal 12V DC source In the dual supply configuration the power supply has a 12 V and a variable output Only 20 mA or 120 mA for the isolated PWMC 402 of 12V is required to supply the PWM Controller whereas the variable power supply output must be rated to accept the load under control Figure 3 3 3 shows an alternate dual supply connection where the load supply is separate from an AC DC wall adapter that powers the PWMC 402 Note that the power supply negative output terminal is commoned at the PWM Controller This connection must be made if the power supply outputs are isolated Some laboratory power supplies have one common ground for 12V 12V and V variable outputs that are produced from the same supply then this connection may not be required Consult the manual from the power supply that you are using in this application to check if it is required to common the negative terminals externally Additionally applying the common connection at the PWM controller will assist in providing a return path for the power being dumped by the load when switching This will help keep the
23. te for information on available software revisions for the Model 402 PWM Controller The unit may be returned to APM Inc for upgrade minimum service charges apply 5 5 Customization amp Engineering The accurate and reliable digitally generated PWM technology inherent in the Model 402 PWM Controller from APM Inc is also extremely flexible The Model 402 as well as other APM Inc PWM and interface products may be easily and cost effectively modified to suit your specific application Call and discuss your requirements with one of our engineers Our engineering staff has extensive experience in test applications and embedded system applications Applied Processor and Measurement Inc will respond quickly with a quotation upon your request For customizations further information and controller purchase contact Applied Processor and Measurement Inc Phone 716 741 1141 FAX 716 741 1142 E mail sales appliedprocessor com URL www appliedprocessor com Applied Processor and Measurement Inc engineers have been designing microprocessor based instrumentation and embedded control systems since 1980 We welcome inquiries on custom designs variations on this design as well as customized software for your application Call and discuss your embedded control requirements with one of our engineers 21