1. release ZERO and TARE keys and the screen will display as follows SNUG III 5 http www jadever com tw JADEVER SCALE L CAL Step 2 Clear the pan then press TARE key and the screen will display as follows zero calibration on0d Step 3 After a beep the screen will display as follows on1 Step 4 Put the 1 3 load on the pan after a beep the screen will display as follows on2 Step 5 Put the 2 3 load on the pan after a beep the screen will display as follows on3 Step 6 Put the full load on the pan after a beep the screen will display as follows PASS SNUG III 6 http www jadever com tw JADEVER SCALE Step 7 The linear calibration is completed Clear the pan and then press TARE key to enter countdown mode The corresponding loading values in the linear calibration for various models of SNUG III balances MODEL SNUG SNUG SNUG SNUG SNUG Ill 150 I1I 300 Ill 600 Il 1500 II 3000 Linear calibration 50g 100g 200g 500g 1000g on1 Linear calibration 100g 200g 400g 1000g 2000g on2 Linear calibration 150g 300g 600g 1500g 3000g on3 Calibration Table Setting method Press and hold down the MODE key then press ON OFF key release MODE key to enter the setting status MODE key for function shifting UNIT key selecting key for enter and exit a function and functi
2. TAEL TWN Vietnam HONG KONG TAEL TOLA INDIA 14 0 1999694 g 453 59237 g 28 349523125 g 1 7718451 g 0 06479891 g 31 1034768 g 1 55517384 g 3 749996 g 37 4290018 g 37 49995 g 37 799375 g 11 6638038 g http www jadever com tw
3. should be set correspondingly The operation of USB interface equipment is as follows 1 Use USB line to connect the electronic balance and the computer Turn on the electronic balance If USB driver is not installed on the computer prompt information will be displayed on the computer to prompt you that a new hardware is found and its driver is needed to be installed 2 After the driver is installed use the hyper terminal of the computer to test if there is data transmission Procedures for opening the computer hyper terminal is star all programs accessory communication hyper terminal Enter the name click confirm select COM3 or COM4 and click confirm Select the corresponding serial transmission rate If the balance is set SNUG IIT 13 http www jadever com tw JADEVER SCALE at 9600 select 9600 click confirm then the communication can be made 3 The communication mode of USB is the same as that of RS 232 If user has his own computer receiving terminal it can be used for the communication USB interface is an optional device User can select USB interface device or RS 232 interface device according to his need 1 oz 1 dr 1 GN 1 ozt 1 dwt 1 MM 1 tj 1 tl T 1 tH SNUG IM Unit Conversion Table MET CARAT AVORIRDUPOIS POUND AVORIRDUPOIS OUNCE AVOIRDUPOIS DRAM GRAIN U K TROY OUNCE PENNY WEIGHT U K MOMME JPN HONG KONG JEWELRY TAEL
4. Contents Balance pan fixing Protection device Installation mode Description of keys Operation of weight single point calibration Operation of weight linear calibration Setting method _wrrwnnnnnnn nena n ne nnn nena nnn enna nnn nnn nnn nana RS 232 serial interface _ Operation instruction of USB interface Unit conversion table _ _ JADEVER SCALE Procedure of balance pan fixing In installing the balance pan Then loose the transport the fixing screw in the center protection rod on the side of of the plastic balance pan the balance body should be tightened Procedure of disassembling the protection device 1 There is a transport protection rod device on the left side of the balance when facing the front of SNUG III analytical balance 2 Before using SNUG III analytical balance turn the protection rod SNUG III 1 http www jadever com tw JADEVER SCALE counterclockwise to loose it and then release 3 Before transpo
5. e function setting options in rotation RS 232 serial interface The 9PIN connector at the right back of SNUG III balance is a RS 232 standard SNUG III 11 http www jadever com tw BAUD RATE 2400 OR 4800 OR 9600 bps DATA BIT PARITY BIT N NONE STOP BIT 1 CODE ASCII BIT FORMAT LSB JADEVER SCALE interface with No 2PIN for output No SPIN for ground and others useless MSB START BIT DATA FORMAT STOP BIT N G T W LF CR N W net weight G W gross weight T W tare weight SP space Example 2007 04 10 08 32 46 SNUG III SP UNIT http www jadever com tw JADEVER SCALE T W 0 00g N W 499 98g G W 499 98g Computer program 10 OPEN COM1 9600 N 8 1 RS DS LF AS 1 BASICA 20 INPUT 1 A 30 PRINT A 40 GOTO 20 50 END Operation instruction of USB interface Precautions for using USB device 1 This USB interface device can only communicate with computer 2 The computer should be installed with the driver of the USB interface equipment which can be downloaded from the company s website 3 After the driver is installed the communication between this device and the computer behaves as a serial communication and the serial transmission rate
6. e sample weight for 600g shall not be smaller than 0 09g 2 When the weight is unstable the unit flashes 3 The balance will warm up for five minutes after it is powered on 4 When the weight is greater than full load 9e Err 5 will display Operation of weight single point calibration Step1 Please first power off the machine press and hold down MODE key then press ON OFF to power on the machine release MODE key and the screen will display as follows Count Step 2 Press MODE key once again and the screen will display as follows CAL Step 3 Press UNIT key to begin the zero calibration please do not put any article on the pan the screen will display as follows SNUG IM 4 http www jadever com tw JADEVER SCALE ZEro Please wait for a while until the screen displays on1 Step 4 Press TARE key to select the calibration point on1 is 1 3 load and on2 is 2 3 load and on3 is full load Put the corresponding weight on the pan after selection wait for the beep and the screen will display as follows PASS Step 5 The single point calibration is now completed clear the pan Press MODE key and then press SMPL key to enter countdown mode Operation of weight linear calibration Step1 Please first power off the machine press and hold down ZERO and TARE keys then press ON OFF to power on the machine
7. o means not to select automatic power off while 5 means 5 minutes 15 15 minutes 30 30minutes and 60 60 minutes Automatic power off is not executive at unstable state 5 When bAud lis displayed on the screen press UNIT key to enter the mode of selection of setting the RS 232 transmission speed The screen displays XXXX X represents the RS 232 transmission speed Press UNIT to shift until the desired RS 232 transmission speed is selected Press MODE key again to return to the display of bAud 2400 4800 9600 6 When _ ZEro_ is displayed on the screen press UNIT key to enter the mode of selection of automatic zeroing range The screen displays dX X represents the automatic zeroing range Press UNIT key to shift until the SNUG a http ww jadever comtw JADEVER SCALE desired automatic zeroing range is selected Press MODE key again to return to display of ZEro d0 1 2 3 4 5 the higher the value the larger the automatic zeroing range is 7 When Fil jis displayed on the screen press UNIT key to enter the mode of selection of the vibration prevention The display of Fil X X represents the vibration prevention grade Press UNIT key to shift until the desired vibration prevention grade is selected Press MODE key again to return to the display of FiL jo FiL1 2 4 8 the higher the value the highe
8. on setting SMPL key for selection of function setting and for ending the setting SNUG III 7 http www jadever com tw JADEVER SCALE LCD display Function Function setting Function View content Description selection setting selection MODE key UNIT key SMPL Count internal value displays Note 1 on Page 10 CAL Single point automatic calibration Page 4 unit g ct lIb gt oz gt dr gt Selection of unit GN gt ozt gt dwt gt pa dw ON OFF Note 2 on MM gt tl j tT gt Page10 tlLH gt t Selection of unit 9 ol Ps nn ars Note 3 on ozt dwt gt i when powering on oo Page 10 ne MM gt tlj gt tT gt tH gt t 1 SNUG III 8 http www jadever com tw Auto bAud ZEro Fil LigH Print SNUG III Selection of automatic power off Au no 5 15 30 60 Selection of transmission speed 2400 4800 9600 Selection of automatic zero hae d0 1 2 3 4 5 Selection of vibration prevention Fil1 2 4 8 Selection of backlight function onoFF oFF ON Selection of printing mode St Co JADEVER SCALE Note 4 on Page 10 Note 5 on Page 10 Note 6 on Page10 Note 7 on Page11 Note 8 on Page11 Note 9 on Page11 http www jadever com tw JADEVER SCALE External moe ten Pr Fu PC SH 24 Page11 equipment 1 When the Count i
9. r the vibration prevention grade is 8 When LigH jis displayed on the screen press UNIT key to enter the mode of selection of backlight function setting The screen displays KXXX X represents the backlight function setting Press UNIT key to shift until the desired backlight function is selected Press MODE key again to return to the display of LigH onoFF is automatic backlight oFF is without backlight and ON is backlight 9 When Print jis displayed on the screen press UNIT key to enter the mode of selection of printing method The screen displays Pr XX X represents the printing method Press UNIT key to shift until the desired printing method is selected Press MODE key again to return to the display of Print __ Pr Co is continuous printing and Pr St stable printing 10 When Pr Fu js displayed on the screen press UNIT key to enter the mode of selection of external equipment The screen displays KXXX X represents the external equipment Press UNIT key to shift until the desired external equipment is selected Press MODE key again to return to the display of PrFu_ _ PC is to connect to the computer and SH 24 is to connect to the dotted micro printer 11 Ifitis not to enter the mode of function setting press SMPL key to end the function setting and return to normal weighing mode Press MODE key continuously to shift between th
10. rting SNUG III analytical balance press the protection rod inward and turn it clockwise to tighten Installation mode 1 When conducting the weight calibration of the product pay attention to the environment and avoid wind and vibration 2 Usage of unsuitable cells or wrong connection of the wire may bring danger ON OFF ZERO SNUG III Description of keys Key to power on and power off the balance Key for zeroing which will function only within 2 of the maximum weighing capacity when in TARE mode if the tare weight is smaller than 2 of the maximum weighing capacity the tare can be cancelled and it can be zeroed if the tare weight is greater than 2 of the maximum weighing capacity the tare can be cancelled http www jadever com tw JADEVER SCALE TARE Key for deducting the weight to deduct the weight of articles on the balance MODE Key for mode shifting The mode shifts in the sequence of weighing counting percentage and printing time UNIT Weighing unit shifting key 13 kinds of units SMPL In the weighing mode it is the key for Backlight switch valid only when Light is set to ON or OFF in counting and percentage modes it is the key for sampling press it continuously you can select from five sampling numbers 20 50 100 200 and 500 Capable of automatic averaging Weighing Press ON OFF key the screen will fully display and count do
11. s displayed on the screen press UNIT key you can see the present internal value Press UNIT key again and then press MODE key to return to the display of Count 2 When unit is displayed on the screen press UNIT key to enter the mode of selection of unit The screen will display jon g or OFF g gt whereas on represents the use of this unit and oFF is represents the disuse of this unit Press SMPL key to shift between ON and OFF set on for the units to be used and oFF for the units not to be used Press UNIT key you can select from the thirteen units When the selection is completed press MODE again to return to the display of unit 3 When InitU jis displayed on the screen press UNIT key to enter the mode of selection of unit when powering on InitU xx X represents the selection of this unit for use when powering on Press UNIT key to shift among the units until the desired unit is selected Then press MODE key to return to the display of InitU 4 When Auto js displayed on the screen press UNIT key to enter the mode of selection of automatic power off The screen displays XXX X represents the selection of automatic power off Press UNIT key to shift until the desired automatic power off is selected Then press MODE key to return to the display of Auto _ Au n
12. wn One minute later the screen will display 0 00 X and the weighing can begin If backlight is needed please press SMPL key Counting Press MODE after the balance is powered on the screen will display XXXX pes then press SMLP key the screen will display SE Opcs Continuously press TARE key to select from the five sampling numbers 20 50 100 200 and 500 After the selection put the articles to be sampled on the balance pan press SMLP key and you can begin counting when a beep is heard Percentage Press MODE key after the balance is powered on the screen will display XXXX then press SMLP key the screen will display SE 0 Continuously press TARE key to select from the five sampling numbers 20 50 100 200 and 500 After the selection put the articles to be sampled on the balance pan press SMLP key and you can begin calculating percentage when SNUG III 3 http www jadever com tw JADEVER SCALE a beep is heard Print time setting Press MODE key after the balance is powered on the screen will display time XXXX T then continuously press UNIT key to shift to month XX XX D jand year XXXX Y Press TARE key to select the setting position press SMPL key to modify and press MODE key to exit Notes 1 The minimum sample weight 29 resolution For example th