Home

Autoglide Operator - Cardale Garage Doors

image

Contents

1. smart entry system NOTES A In 6c Up to a maximum of 8 handsets can be memorised into the control unit If you wish to ERASE handset codes Follow previous instructions to step 2 inclusive Press and hold button for 10 seconds and release orange LED will flash Press button to accept this instruction The ep will now show GREEN FLASHING GREEN indicating that you have returned to normal STANDBY MODE This will have erased ALL stored handset codes if there are any that you wish to retain you must re enter them by following previous steps 1 13 Courtesy lamp if fitted In standby mode it is possible to turn on the courtesy lamp without operating the door by simply pressing both buttons on the handset simultaneously The lamp will stay on for approximately 3 minutes before automatically turning itself off Configuring the child lock Ensure that the power switch on the unit is in the off position see Figure 25 Plug in the power supply cable see Figure 25 and turn on at the mains but leave the switch on the unit turned off for the moment In IA W N Press and hold down the button Turn on the unit power switch The 9 LED should briefly flash green Release the button The ie LED will now be red or green If RED the lock is DISABLED i e door can be opened using the button If GREEN then lock is ENABLED i e door cannot be opened using
2. smart entry systemi E Problem solving J 1 IN IW S UNIT FAILS TO OPERATE WHEN MAINS POWER SWITCHED ON a If red LED above J is NOT LIT Remove power lead 13A plug from supply socket Use test lamp to check power is available at the 13A socket Check fuse in 13A plug NB should be fitted with a 5A Fuse Remove power lead from the Autoglide unit Check fuse in the Autoglide power input socket see Figure 25 Should be fitted with a 250v 2A slow blow x 20mm long fuse b If Red L E D above is LiT Check if unit can be operated from either i The remote handset il The Q button on the control unit provided child lock is disabled shown by a flashing green LED iii The remote bell push button If any of the these operate the door then the unit is functioning properly The start methods that failed to operate the door will need to be checked out separately see in later sections Should the unit fail to operate by any of the above start methods i Turn the power switch on the unit to the OFF position ii Wait for 5 seconds then turn back ON again This will re set the control system iii Re try start methods as above MOTOR OPERATES BRIEFLY BUT DOOR REMAINS FULLY CLOSED the LED flashes briefly RED Door not de latching correctly Check adjustment operation of latches Section 4 8 Check position setting of tilt bracket
3. Figure 21 FA a Me A E Figure 23 AU TOG ip e smart entry systemi OQ Configuring your Autoglide operator Autoglide can be quickly and easily set up by the use of three buttons each of which has a corresponding status LED ORANGE Continuous when remote RED power control signal on to unit is received up down Press this button to open close the door depending on child lock config In set up mode this button selects the enable disable of the child lock Figure 24 IN LEARN MODE See relevant section for description IN STANDBY MODE awaiting command Continuous GREEN child lock enabled Flash GREEN child lock disabled IN RUN MODE Continuous GREEN motor running door in motion Flash RED obstruction or other problem LED BUTTONS handset config Configures Configures the the power sensitivity remote control settings of the motor handset s and configures the child lock 6a Configuring the power and sensitivity set up Ensure that the power switch on the unit is in the OFF position see Figure 25 NOTE Before commencing power set up sequence ensure that a Limit switches are adjusted to their AU 0611p e smart entry system ON OFF switch Power input socket and Lamp out connector nominal positions fuse b All latches operate correctly c Drive pin is correctly engaged Bell pu
4. through bottom hook of latch lever Figure 19 and return cable through cable clamp Tighten using M4 x 8mm Hexagon head screw supplied to give 6mm 1 4 gt y engagement at both latches Figure 15 IO Force latch cam to the right across slot Siener eonnguration may very using a screw driver Figure 20 to check a Figure 18 operation of latches Re adjust latch settings if necessary Cam pin Latch cam cable Move j latch across slot Drive carriage To cable adjuster Hex head screw Figure 19 Figure 20 AU 0611p e smart entry system Q Engaging the motor 1 Open door to identify position of 10mm diameter round hole in Dymetrol tape this is marked with silver paint Figure 21 Move the door so as to align the red manual release lever with the 10mm hole Re engage the drive pin in the 10mm diameter hole in the Dymetrol tape by operating the manual lever see Figure 7 N B To ensure drive pin is correctly engaged try to move door up or down manually it should not be possible 2 Move top open limit switch to a position 5mm from top of track Figure 22 3 Move bottom close limit switch to a position 15mm above motor Figure 23 Figure 22 10 mm diameter hole
5. Before installing the operator check that the door is in good mechanical condition and correctly balanced and that it opens and closes properly Do not use the force adjustments to compensate for a binding or sticking garage door Excessive force will interfere with the proper operation of the Safety Reverse System or damage the garage door Do not wear rings watches or loose clothing while installing or servicing a garage door operator To avoid serious personal injury from entanglement remove any ropes connected to the garage door before installing the door operator Install the remote mounted bell push button within sight of the door but away from any moving parts and at a height of at least 1 5 metres Permanently fix the label warning of entrapment in a prominent place or near the remote bell push button The safety reverse system test is very important The garage door must reverse when obstructed on closing Failure to properly adjust the operator may result in serious personal injury from a closing garage door Repeat the test once a month and make any needed adjustments see Section 7 in manual Safety sensitivity check smart entry systemi G1 pe AU TOG ip e smart entry system A am AN Installation and wiring must be in compliance with your local building and electrical codes Connect the power cord only to properly earthed mains Use a ring main 13 amp 3 pin socket installe
6. the button ee AU TOG ip e smart entry systemi Z 100 IO To change the status of the lock press the button and the LED will change to either red or green as the button is depressed To save the child lock settings press and release the button If the lock is disabled the ine LED will flash green can open door 10 If the lock is enabled the 29 LED will shine constant green cannot open door NOTE Whether the child lock is enabled or disabled Autoglide can still be operated using the handset a A SAFETY NOTE If there is a chance that children may play in the entry of the garage then ensure the child lock is ENABLED so that the door CANNOT be operated from the button a S O Safety sensitivity check Your Autoglide control system contains advanced electronics that monitor power over the full OPEN CLOSE cycle and computes a SENSITIVITY FACTOR to ensure user safety To check the operation of this signal the door to close and when it is halfway down obstruct the door at the bottom edge using both hands Using only light to medium force the door should stop and then reverse to the fully open position If excessively heavy force or extremely light force is required to stop the door then RE CONFIGURE the POWER and SENSITIVITY SET UP as instructed in Section 6A AU O61 1p e smart entry system Autoglide status modes Stand by mode When Autoglide is in stand by mode the
7. Q is constant red which indicates power on The 9LED will be either flashing green or constant green dependant upon child lock setting If there is a problem detected a flashing red LED will be seen If this is the case turn the power supply switch on the unit OFF for 5 seconds then ON again to re set the unit See Configuring your Autoglide operator Section 6 If the unit displays an alternate flashing red green LED the unit has detected a fault which may require a service call see problem solving To operate the door press the nominated button on the key fob If the child lock is disabled flashing green LED the door can also be operated by pressing the T button on the motor unit Obstruction CLOSING When Autoglide detects a obstruction i e something in the way of the door or a stiff runner etc the LED will flash red for a short period If there has been an obstruction when the door is travelling DOWN closing the door will stop the aS LED will flash red and the door will reverse and return to the open position As the door is opening the LED will be red until the door is fully open It will then change to green flashing green OPENING If there is an obstruction when the door is travelling UP opening the uwil flash red for a period then change to green flashing green The door will remain in this position until the next command signal is received when it will then reverse and travel to the CLOSED pos
8. as a separate item in the kit box item 14 CAM PIN TA AT TOP Prior to fitting the latch release cable Section 4 in the fitting instructions you simply need to Ne a0 slide the outer sheath over the cable that is already attached to the Autoglide unit then Sma proceed as per the fitting instructions 1 Ensure manual lever is still disengaged and fully close door Ensure drive carriage is pushed as far down as it will go i e with cam pin at top Plasti of slot Figure 12 roller Figure 12 2 Fit tilt bracket to door Figure 13 19mm 3 4 above plastic roller on tilt pin with drive carriage still fully down NOTE Use the No 8 x 3 4 countersunk screw in bottom hole and the No 10 x 3 4 pan head in the top hole Figure 13 use 3 5mm diameter drill To top hatch Cam pin Drive carriage Fully down Latch lever Tilt pin Plastic roller Countersunk screw Figure 13 Figure 14 AU 0611p e smart entry system Nominal 6mm Engagement V A S Baiia Fix here Latch plate lt a lt fag Us ls ol nein Hole level with lower hook Figure 15 i ee 3 Fit eurolock handle as per door fitting instructions and turn fully anti clockwise Stitfener configuration may vary when viewed from outside Place lock Figure 16 p cam onto lock spindle with the tang p
9. Section 4 2 MOTOR OPERATES BUT DOOR DOES NOT MOVE MOTOR RUNS ON the 83 LED flashes intermittent RED Motor drive not engaged Check drive pin correctly engaged Section 5 MOTOR OPERATES BUT DOOR FAILS TO FULLY OPEN OR CLOSE the 9 LED flashes briefly RED i Turn OFF mains power to unit and read safety notes at the front of this manual lui Is IN 100 AU 0611p e smart entry system ii Operate manual release lever to disengage drive Section 3 5 iii Test door operation and correct any binding or out of balance iv Re engage drive Section 5 and turn power back on Reconfigure power and sensitivity settings see Section 6a DOOR CLOSES BUT LATCHES DO NOT ENGAGE Check that drive carriage has been pulled down to its lowest position see Figure 12 in Section 4 Check latch cable settings Section 4 8 Check tilt bracket setting Section 4 2 Grease latch release cam and pin on drive carriage Grease latch plates and latch pins on door Check bottom limit switch has been set low enough to ensure slam action of latches DOOR SHUTS TOO VIOLENTLY OR SHUTS AND THEN OPENS AGAIN IMMEDIATELY Adjust the bottom limit switch to a slightly higher position UNIT FAILS TO OPERATE AND LED FLASHES ALTERNATE RED GREEN Indicates a limit switch fault i Switch off power to unit and read safety notes at front of this manual ii Operate manual release l
10. acket with special cut down bracket supplied parts list item 12 ii Repeat for other right hand wall fixing bracket iii Offer track to right hand side of door and slide spindle into shaped recess in top of drive carriage Align holes in track with pre pierced holes in frame channel iv Slide one 3 16 washer between channel and track and align with centre fixing hole Fix track to channel using one No 8 x 1 self tapping screw provided v Repeat for other two holes in track vi Secure the motor chassis by sliding one 3 16 washer under each fixing hole and using the two No 10 x 2 self tapping screws supplied Figure 11 N B On bottom fixing use 1 black spacer insert provided to place between chassis plate and frame Ensure spacer is the correct way round see Figure 11 with the screw passing through spacer OPEN CLOSE DOOR SEVERAL TIMES TO ENSURE DOOR OPERATES FREELY NOTE 3 16 WASHERS NOT REQUIRED ON CD PRO STEEL FRAMES AU 0611p e smart entry system 25mm CD45 gt 6mm CD PRO i Figure 9 Via 1 Figure 10 a countersunk screws No 10x2 screws Figure 11 AU TOG ip e smart entry systemi o Fitting the latches NOTE LATCH RELEASE CABLE To avoid kinking the latch release during packaging transit the outer sheath of the cable is now supplied
11. any doubt at all consult a qualified installer see Yellow Pages for details NOTE If door is not yet fitted fit door to opening only after completing stages 1 and 2 refer to door fitting instructions Do NOT fit latches at this stage 1 Cut out a 30mm x 100mm rectangle in top of right hand side seal of door looking from inside garage as shown in Figure 1 NOTE Later doors already have this cut out IN Replace existing spindle on right hand side of door looking from inside garage with special spindle supplied in accessory pack im as follows a Open door fully and remove screws from centre of right hand runner Figure 2 Cut out b Close door fully ensuring latch is engaged Grip right hand black cone Side seal pulley with spanner and by turning upwards align holes in anchor bush and spring shaft Insert retaining pin supplied fully into hole Figure 3 and remove spanner Figure 1 c Remove right hand side runner and security block by removing screws at top and bottom of runner Figures 4 amp 5 R H black ae ae ron here A D j i anchor y D bush Y Lor ST a ie Retaining pin an Runner Figure 2 Figure 3 AU 0611p e smart entry system Remove top H fixing screw Figure 4 d Lever off star washer from inboard end of spindle with screwdriver Figure 5 NOTE On lat
12. d by a qualified electrician The plug should be fitted with a 5 amp fuse THIS APPLIANCE MUST BE EARTHED NOTE For optimum electrical safety this operator should be connected to a circuit protected by an R C D max 30mA trip rating If the garage has no service entrance door then an exterior release kit MUST be fitted This accessory allows manual operation of the garage door from outside in case of power failure See back page Disconnect electric power to the garage door operator before making repairs or removing covers Use the manual release lever to disengage the motor drive ONLY when the drive is switched OFF and if possible when the door is fully closed Examine the installation in particular the cables spring and mountings for signs of wear damage or imbalance Do not use if repair or adjustment is needed since a fault in the installation or an incorrectly balanced door may cause injury IMPORTANT SAFETY NOTE Only operate the door when the door is in full view free of obstacles with no persons particularly children near the door Nobody should be allowed to enter or leave the garage whilst the door is in motion Pre installation checks A Fit only to Cardale CD 45 and CD PRO garage doors conversion kits are required for fitting to other trackless gear systems See back page B Do not fit Autoglide to any door larger than 8 0 wide x 7 0 high 2438 x 2134mm C The timber goalpost frame must be a minim
13. er doors remove circlip e Pull door slightly away from frame and remove spindle Unhook from cable N B On some installations difficulty may be experienced in removing spindle pin because of restricted side room In extreme circumstances door may have to be taken out f Loop cable over new spindle ensuring loop is located in groove Figure 6 g Refit spindle through hole in bracket h Push new star washer correct way round onto spindle using pliers or suitable size pipe if available ensuring there is no free play on spindle Figure 6 DO NOT REPLACE RUNNER i Remove retaining pin by reversing step b Figure 5 starlock washer Figure 6 IMPORTANT NOTE On CD PRO doors fitted with floating wheel spindles you MUST fit nylon spacer to LH spindle to eliminate end float see instructions in item 15 AU TOG ip e smart entry systemi Figure 7 Iw ln If door has not yet been fitted fit now refer to door fitting instructions but do not fit latches at this stage If door is already fitted remove all latches now ENSURE DOOR IS CORRECTLY TENSIONED AND LUBRICATED Open door three quarters of full opening height Take the Autoglide track unit and operate manual release lever Figure 7 by pushing towards drive carriage This will disengage drive carriage from Dymetrol tape inside the track Slide the carriage to a position approxi
14. ever to disengage drive Section 3 5 and manually move door to half open position iii Check operation of both limit switches by depressing the small plunger pin several times to ensure that it springs back out again and that there is an audible click from the switch iv RE engage drive Section 5 and turn power back on v Test operation again If L E D still flashes alternate RED GREEN then a limit switch is damaged faulty and will require a service engineer visit UNIT FAILS TO OPERATE FROM REMOTE BELL PUSH Check connections to bell push are correct and secure Check operation of bell push button makes breaks the contacts Check wiring for damage breaks and is routed away from any mains electrical cables Check connections to 2 way plug in Autoglide unit are correct and secure Check 2 way plug is fully engaged into socket in Autoglide unit AU TOG ip e smart entry systemi 9 UNIT FAILS TO OPERATE FROM REMOTE CONTROL HANDSET Check that signal is being sent from the handset see Section 8 page 19 Check that Autoglide unit is receiving the signal The orange LED should light up when the handset is pressed to indicate that signal is being received if this fails to happen i Check that handset has been configured into the control system see Section 6b ii Check that correct handset button has been pressed try other button to make sure iii Check handse
15. ition Handset To check to see if the HAND SET is working press the selected handset button An orange LED will light above the button Also a red LED will light on the handset If the handset battery is low the red LED will flash when the handset button is pressed If so then replace the battery This is done by removing two screws on the back of the key fob Replace with the same type of battery GP23AE AU TOG ip e smart entry systemi Fitting the Remote bell push and Courtesy lamp Control box Bell push 9a Remote bell push 1 Your Autoglide is supplied with a Bell push so that you may have REMOTE push button control 2 Fit the Bell push button in the required location using the yellow wall plugs and No 4 x 1 screws provided 1 5 metre min Remember to mount at a minimum height of 1 5 metres out of reach of small children and for safety it must be within sight of the door to be operated but not within the area of movement of the door A a 3 Use twin core bell wire or telephone cable not supplied and connect the bell push to the green 2 way input plug on the control unit see Figure 26 4 Be sure to route the bell wire away from mains electric cables to reduce the possibility of electrical interference generating phantom signals Secure bell wire with suitable cable clips 9b Courtesy lamp if supplied 1 Ensure mains power to the Autoglide unit is
16. mately 305mm 12 from top of track 6a If door is fitted to a timber frame Offer track up to right hand side of door and slide spindle into shaped recess in top of drive carriage Figure 8a Position top of track 25mm CD45 or 6mm CD PRO from underside of top lintel Figure 9 Ensure spindle fits comfortably in recess with 1 0mm clearance between end of spindle and carrier housing Figure 8b Screw track to side jamb using 3 off No 8 x 1 countersunk self tapping screws provided Figure 11 ensuring track is parallel to side of door Figure 8a 1 0 mm lt Spindle Drive carriage Figure 8b Secure the motor chassis with the two No 10 x 2 self tapping screws provided Figure 11 N B On bottom fixing use 1 black spacer insert provided to place between chassis plate and frame Ensure spacer is correct way round see Figure 11 with the screw passing through the spacer OPEN CLOSE DOOR SEVERAL TIMES TO ENSURE DOOR OPERATES FREELY 6b If door is fitted to a Steel frame IMPORTANT Your CD45 CD PRO framed door must be fitted correctly in accordance with the framed door fitting instructions for behind the brickwork installation Unfortunately Autoglide cannot be fitted to a CD45 CD PRO framed door fitted between the brickwork Figure 10 i Close door fully and prop securely in position Remove ONE wall fixing bracket from right hand frame side channel Replace removed br
17. ointing downwards fit latch lever over lock cam in orientation shown Figure 14 and secure using self tapping screw and washer 4 Attach top and left hand side latches as per door fitting instructions and attach cables to hooks on latch lever in configuration shown Figure 14 Latch cable lengths must be adjusted to give approximately 6mm engagement of latch pins Figure 15 5 Attach triangular gusset plate to stiffener situated to the right of the latch lever Figure 16 The gusset must be located with the lower 8mm diameter hole level with the lowest hook on the latch lever Figure 16 Fix gusset to stiffener using 2 off No 10 x 1 2 self tapping screws provided Drill holes 3 5mm diameter 6 Attach cable adjuster through lower 8mm hole in corner gusset ensuring threaded end of adjuster NN O is pointing towards latch lever and is screwed S completely into adjuster block Figure 17 NOTE Highest hole on corner gusset should be kept available for exterior release system The exterior release system is available from Cardale as an accessory Figure 17 AU TOG ip e smart entry systemi IN Route latch release cable through cable adjuster and fix to door as shown Figure 18 using cable ties supplied Aim for smooth gentle curves on the cable run avoid tight bends and kinks N B Cut sheath to length if necessary to achieve best results 100 Slide cable clamp over cable pass cable
18. r cover Lamp out connector 10 Plug lamp output connector into the Autoglide unit see Figure 28 11 Tidy up mains input lamp output and bell wire cables using the cable clamp item 6 and 2 off No 6 x 1 2 pan head self tap screws provided see Figure 28 DO NOT OVERTIGHTEN 12 Switch mains power back on to the unit and test the lamps and the bell push by operating the door The lamp should come on as soon as the door is operated and go off automatically after approximately 3 minutes IMPORTANT NOTE This unit can only be used with INCANDESCENT lamps It must not be used with fluorescent or halogen lamps Final checks Upon completion of installation and when handing over to the end user the installer should carry out the following 1 Grease latch pins and latch cam and ensure all screws and fixings are fully tight 2 Check manual operation of the door to ensure correct balance 3 Check operation of drive unit over full open close cycle to ensure correct functioning Carry out Safety Sensitivity check Instruct end user in location and use of the Manual Release lever Explain function of Child Lock safety feature on the button NOTE If in doubt ensure that the child lock is ENABLED so that door CANNOT be operated from the button see Section 6c 7 Ensure the User manual is left with the end user as this contains In ln b important safety and warranty information AU TOG ip e
19. sh 4 connector d Door is clear of obstructions Plug in the power supply cable Figure 25 and turn on at the mains but leave the switch on the unit turned OFF for the moment Figure 25 1 Press and hold down the 29 button Turn on the unit power switch then release the button IN The RED LED above the button should flash briefly to show door is between the limit switches Briefly press the button once to move the door to the fully open position NOTE If the motor runs but the door does not move and the 29 LED flashes red TURN OFF POWER Ensure drive pin is correctly engaged in drive tape see section 5 Then restart set up sequence 3 With the door now fully open briefly press the button once to close the door for the DOWN LEARN sequence 4 When the door is closed briefly press the button again to open the door for the UP LEARN sequence 5 The 9 LED should now show green or flashing green to confirm that set up has been successfully completed NOTE Where necessary move the limit switches up or down no more than 6mm at a time to ensure the door fully opens and closes without excessive slamming Go through stages 1 4 each time a limit switch is adjusted CD PRO IMPORTANT NOTE When setting TOP limit on CD PRO ensure the wheel spindle fully enters the SAFEHOLD on LH track AU TOG ip e smart entry systemi B 6b Configuring the remote control handset Ensure that the power
20. switch on the unit is in the OFF position see Figure 25 Plug in the power supply cable see Figure 25 and turn on at the mains but leave the switch on the unit turned off for the moment 1 IN Iw e lui Is Press and hold down the button and turn on the unit power Release the button Briefly press the button again The LED will light orange Press either button on the handset The orange LED will go out Press either button on the handset again The orange LED will flash for approx 10 seconds NOTE To set up another handset repeat stages 5 6 When you have finished setting up the handset s continue with stage 7 Z 100 IO Configuration of handset buttons with the button released press the handset button that you wish to use to operate the door The p should light orange to acknowledge receipt of the signal In addition if the left handset button is pressed the LED will flash red if the right handset button is pressed the LED will flash green If you want to change buttons press both buttons on the handset simultaneously to reset The LED will flash orange briefly and the LED above will flash red then flash green and then repeat stage 7 To configure additional handsets also repeat stage 7 Press the 9 button to store your settings 10 The 9 LED should show green flashing green indicating that the handset s have been successfully configured AU 0611p e
21. switched OFF 2 Fix the courtesy lamp in the position you require carefully following the fitting instructions supplied by the lamp manufacturer 3 Measure the length of cable required to connect the courtesy lamp back to the Autoglide unit and obtain sufficient cable which must be to the following specification 3 CORE 3183Y MAINS CABLE 75mm 6 AMP 4 Connect one end of the cable to the lamp unit in accordance with the lamp manufacturers instructions IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN Fit 60W MAX GLS bulb to the lamp unit not supplied 5 Run the cable back to the Autoglide unit in a safe and professional manner in accordance with current IEE wiring regulations Secure cable with suitable cable clips 6 Ensure mains power to the Autoglide unit is switched OFF 7 Select the lamp output connector item 11 from the parts supplied and using a small electrical screwdriver remove the connector cover by undoing the central screw 8 Pass the cable through the shroud and under the cable clamp and then connect to the screw terminals as per Figure 27 IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN AU 0611p e smart entry system Connect yellow green wire to earth Connect blue wire to terminal N Connect brown wire to Terminal L Mains input connector Figure 21 Cable 9 When correctly connected ensure all terminal screws are tight tighten the cable clamp and refit the connecto
22. t signal see above 10 UNIT FAILS TO OPERATE FROM BUTTON Check that the unit has been configured to operate button flashing green LED To change configuration refer to Section 6c paying particular attention to the SAFETY NOTE The following accessories are available for use with your Autoglide MK III operator AZAA 3152 Additional handset 433 MK III A AZAA 3120 Exterior release kit Cardale CD45 AZAA 3141 Lamp kit AZAA 3160 Electric key switch AZAA 3101 Retro fit kit for Henderson Premier cable latch AZAA 3102 Retro fit kit for Garador Mk III C AZAA 3103 Retro fit kit for Henderson Premier solid bar AZAA 3104 Retro fit kit for Henderson Pre premier doors after 1987 AZAA 3121 Exterior Release kit for Henderson Premier cable latch AZAA 3122 Exterior Release kit for Garador Mk III C AZAA 3123 Exterior Release kit for Henderson Premier solid bar AZAA 3124 Exterior Release kit for Henderson Pre premier after 1987 AZSP 7036 Replacement handset battery GP23AE In the event of difficulty please consult your local Cardale dealer see Yellow Pages or contact Cardale service department 01280 705077 DPIN 1225 ISSUE C 25 5 06
23. um of 70mm wide at the right hand side of the door looking from the inside of the garage and the frame must be in good condition and securely fixed D Ensure the door is correctly tensioned and properly lubricated The operator will not function properly if the door is poorly installed in any way Also check that lifting cables and gear are in good condition E Prior to installing your Autoglide unit ensure all tools etc are available inside the garage E Ensure that there is a suitably positioned 240v 13A socket outlet available inside the garage this must be earthed AU 0611p e smart entry system eT E E Cut out for limit switch Open limit switch Drive track containing Dymetrol drive tape Latch lever Triangular gusset and cable adjuster Latch release Spindle Drive carriage Manual release Close limit switch Tilt pin Tilt bracket Drive motor and cover View of Autoglide track unit from inside the garage door bracing may vary AU TOG ip e smart entry systemi Parts check list Please check box contents and collect necessary tools ITEM NO PART CHECK QUANTITY 1 Operator track unit Power lead Handset Assorted screws fixing Tilt bracket Cable clamp moulding Gusset plate Spacer AN HD UH A U N Special spindle oO Push button control and fixings Lamp output connector Frame door fixing pack Lamp holder
24. where supplied Latch release cable outer Fittings instructions pack for CD PRO Contents of item 4 bag AU 0611p e smart entry system DESCRIPTION Track fixing screw No 8 x 1 S tap C sunk Chassis fixing screw No 10 x 2 S tap Pan HD Cable tie Gusset plate fixing No 10 x 1 2 S tap Pan HD Yellow wall plug for push button and No 4 x 1 S tap C sunk screws Cable clamp for latch cable Split pin to retain door tension Tilt bracket top fixing screw No 10 x 3 4 S tap Pan HD Tilt bracket bottom fixing screw No 8 x 3 4 S tap C sunk Cable clamp fixing No 6 x 1 2 S tap Pan HD Star lock washer for spindle Tools required 1 Power drill 6 Pozidrive screwdriver 2 Masonry bits 7 22mm ASF spanner 3 Steel drill bit 3 5 diameter 8 Hacksaw 4 Pliers 9 Small electrical screwdriver 5 Plain screwdriver 0 Tape measure Cable fixture plus nut and washers NOTE Where the garage door is the only means of access it is recommended that the optional Exterior Release kit is fitted L ID IMPORTANT NOTE If you are fitting to a door supplied sma rt entry systemi with CD PRO gear use instructions supplied in item 15 G Fitting the track assembly WARNING The spring is under extreme tension follow instructions carefully to avoid personal injury If in

Download Pdf Manuals