Multi-Bio Series Installation Guide
Contents
1. Door Sensor Button Power Supply Multi Bio Series Installation Guide V1 0 2 3 Time Ring connection Connect the electrical bell to the fingerprint machine when arrive the appoint time the fingerprint machine will send signal to trigger relay The terminal supports both Normal Open bells and Normal Close bells at the same time Normal Open bells Bell Power supply 2 Normal Close bells Power supply Multi Bio Series Installation Guide V1 0 2 4 Door lock connection The way of installing door lock depends on the type of lock and local condition Internal resistor which comes from long distance transfer should be taken into consideration when selecting the cable of electric power The door lock should be installed reliable and stable Ensure the wiring is correct For the strike lock and electromagnetic lock you should pay attention to positive and negative terminal connection The unused bare end of wire should be cut off and use insulating tape to wrap it The delay time of strike lock is adjustable according to different conditions Select electric lock s it is better to use strike lock for the two direction opening glass door both open to inside or outside direction for the single opening wood door in company internal we recommend to use magnetic lock the magnetic lock also be called as electric magnetic lock The magnetic lock is more reliable than the strike lock but the strike lock is much s
2. connect the majority access controllers on the market at this time it is used as a reader Note 1 The distance between device and access controller or card reader shouldn t be over 90 meters If a longer distance is needed or there is interference in using environment please use Wiegand signal de lay 2 To ensure the stability of the Wiegand signal the device must share the GND with controller or Weigand reader 3 If the distance of Wiegand output or 485 communication is over 90 meters in order to reduce the interference caused by the long distance it is suggested to use the cable with shield and connect the shield cable to the SGND terminal 15 Multi Bio Series Installation Guide V1 0 2 9 Power Connection The device s working voltage is DC12V with working current 500mA standby current 50mA has provided two ways to connect power please select one referring to the actual 1 Terminal connection Make sure the connection as the diagram Don t connect the poles in reverse 2 Slot connection Insert the plug of DC12V adapter into the power slot directly Power Slot 2 U Y o ri a Fi A M 4 12V DC12V J DC 12V Terminal connection Slot connection 16 Multi Bio Series Installation Guide V1 0 3 Others 3 1 Reset Due to operation error or other accidence which leads the machine not to work you can restart machine through reset key D take a small tool which diameter
3. Installation Guide V1 0 Power key Technical parameters Charge time Less than 4 H Discharge More then 5 5 H fe een Working 0C 50C Relative 10 90 humidity Storing Please store the battery when the discharge environment capacity is full and the environment is 20 C 5 C Cycle age Cycle times of charge and discharge2300 times Notice There is a danger of battery exploding leak fever fire break if you don t read the notice carefully A Do Not use it over 50 C A Do Not inverse polarity connection A Do Not put the battery into water or let it to get wet A Do Not use and store battery near heat generating machine such as fire or heater 20 Multi Bio Series Installation Guide V1 0 A Do Not throw batteries into fire or hot battery A Do Not use wire or other metal short the positive and negative terminal 2l
4. Multi Bio Series Installation Guide Versions 1 0 Date Sep 2009 About this Guide This guide provides actual installation instructions only For information regarding user instructions please refer to iFace Series User Manual Multi Bio Series Installation Guide V1 0 Content 1 Sy Stele C OM GURANOM P 1 1 1 View of Operation panel eret eene notet Re nth eee 1 1 2 The illustration of system construction seeeeessesssse 2 1 3 The sketch map of communication esseeeeeeeeeess 3 atcur 4 2 1 Door sensor CONNECUON etre ki eke CA e hx e CAG 6 2 2 EXIt Dttori CoOnnecllal soe eret a Ex Uri ers 6 2 9 lime FRING eontiecllori eia oi oda teet iraia aaiae anai 7 2 4 Door lock colnecllol eio oh eer Eee enne dad ade er Sete es 8 2 9 Ethierhet CONNECHON oce o ertet to Cent ha b ei oe E eaten 12 20 terere ETE 13 249495 CONNECCION occi neto atero O OS 14 2 8 Wiegand Output Connection eeeseeeeeeeeeeereeee 15 29 ier galeae 16 SAONE Son ode asta costes tabo se t uo annette CU E LP cL EU ies 17 SM ROSO ete TE D m UU TIU 17 3 2 Anti disimarntle DUEtOLH cie rete eaS 17 Seo BRIZ Nel Gic cR 18 3 4 Reserve Ballery e ee D Ead icd Ulead e eaa 19 Multi Bio Series Installation Guide V1 0 1 System Configuration 1 1 View of operation panel LED light Touch screen Fingerprint Sens
5. afer than the magnetic lock In the small living community it is better to use strike lock and magnetic force lock The electric control lock gives out higher noise the electric control lock is commonly used to building communication Now there is a soundless electric control lock which is able to be applied Please pay attention the lock is made of iron and easy rust so you must beware of not exposing it to water or harsh condition there are some other electric locks available we don t recommend you to use them Connect with electric lock The Normal Open lock is open when the power is on The Normal Close lock is closed when power is on The machine 8 Multi Bio Series Installation Guide V1 0 supports both of the two kinds of locks at the same time The way of lock connection changes with the type of lock For NO lock the NO terminal will be used for NC lock the NC terminal will be used This access control machine is powered by DC 12V and work current 400mA If the lock work electric power is DC12V and the work current is less than 1000mA the fingerprint machine and lock are able to be powered by one adapter together please refer to table 1 2 In the following three cases we recommend that fingerprint machine and lock are powered separately 1 The working voltage of the lock is DC12V but the current difference of the fingerprint machine and the lock doesn t exceed 1A 2 The lock voltage is not DC 12V 3 The distanc
6. e between lock and fingerprint machine is too far Multi Bio Series Installation Guide V1 0 NO LOCK DCI2V Picture Power by one supply NC LOCK Picture2 power by one supply Multi Bio Series Installation Guide V1 0 O X Lock Power t e Y ae Lock Power WY T Wo Picture 4 The terminal and lock powered by independent adapters Multi Bio Series Installation Guide V1 0 2 5 Ethernet connection The terminal provide two ways connect Ethernet 1 The terminal connect with PC through cross cable IP 192 168 1 101 IP 192 168 1 100 Mask 255 255 255 0 Sub Mask 255 255 255 0 iFace 2 The terminal connect with PC through network and HUB to create a local network PC T oa an Switch 12 Multi Bio Series Installation Guide V1 0 2 6 RS232 connection The terminal connect with PC through RS232 Note Don t upload or download facial module through RS232 because the large data will effect the transfer speed PC Serial Port 13 Multi Bio Series Installation Guide V1 0 2 7 RS485 connection The terminal connect with PC through RS485 Note Don t upload or download facial module through RS485 because the large data will effect the transfer speed i 185B TT t o 485A 485B o RS485 MGR curi p wil oe T1 Od je RS232 14 Multi Bio Series Installation Guide V1 0 2 8 Wiegand Output Connection The device has Wiegand output function can
7. inal connection From left to right A Nee Connect to Cable Bell NO terminal COM Connect to Cable Bell COM terminal Tie up together Connect to Cable Bell NC terminal 4 Sens Connect to Door sensor Or 5 GND For Door sensor and release button together Connect to Release button Connect to Lock NC terminal COM Connect to Lock COM terminal Tie up together Connect to Lock NO terminal Connect to RS485B Tie up Connect to RS485A together 12 GND Connect to RS232 and Weigand GND Tie up D Connect to Power GND Tie up Connect to Power 12v together Tie up Multi Bio Series Installation Guide V1 0 2 1 Door sensor connection The door sensor is used to detect the door open close state terminal can monitor if the door has been unauthorized open through the door sensor at this time it can output a alarm signal moreover terminal can trigger prompt warning if the door is not close tightly 2 2 Exit button connection The exit button is installed for in door operation When the switch of the button is close the door will open The distance is approximately 1400mm from ground to exit button bottom Make sure that the exit button position is to align correct upright and the connection is accurate and reliable Unused exposed end of cable should be cut off and use insulating tape to wrap it Pay attention to electromagnetic disturbance For example The light switch the computer and so on Ex
8. is no more than 2mm 2 find reset mark of res on the left small hole on the bottom of device see following figure Use the tool plug into the hole refer to the picture on right then plug out The machine is able to restar L Bs NN Reset NS kk LAS i B b iN hk WC J b WA X i k TA k i wv a LU m 3 2 Anti dismantle button Anti dismantle button is on middle of device whose function is Ln Multi Bio Series Installation Guide V1 0 realized by back cover pressing the anti dismantle button When the device is being dismantled it will send a alarm signal through the terminal Anti dismantle button 3 3 U flash disk using D there is a mini port of USB please see figure circle on the left 2 USB can be used to upload and download data by U disk 18 Multi Bio Series Installation Guide V1 0 USB Port 3 4 Reserve Battery Work principle Before use make sure the reserve battery is installed properly Whenever use power supply or reserve battery you need press power key to turn on the terminal In normal state When the power cut down the reserve battery will switch into discharge state to power on the terminal In power off state when the power cut down the reserve battery will not switch into discharge state to power on If you want to power on the terminal you need press power key to turn on the terminal 19 Multi Bio Series
9. or Camera Baseline S Power TCP IP USB D RU Battery slot lt ad SA Joo Loudspeaker Multi Bio Series Installation Guide V1 0 1 2 The illustration of system construction Doorsensor Multi Bio Series Installation Guide V1 0 1 3 The sketch map of communication 1 Fingerprint machine directly connects with PC through RS232 or TCP IP TCP IP or RS232 f j j j j j j j T 7 j j j L j f PY 2 Fingerprint machine connects with PC through RS485 network s 485A e 485A 485B RS485 E ec c PC a RS485 Switch RS232 JE Multi Bio Series Installation Guide V1 0 2 Installation Caution Do not to connect peripheral equipment before the power of the device is cut down otherwise it is possible to damage the device badly Please follow instruction to connect peripheral equipment Door sensor connection Sensor GND Exit button connection Button GND Alarm connection NC2 COM2 NO2 Door lock connection NC1 COM1 NO1 Ethernet connection RJ45 1 RJ45 2 RJ45 3 RJ45 6 RS232 connection 232T 232R GND RS485 connection 485A 485B Wiegand output connection WDO WD1 GND Power connection 12V GND 9 C 9 6 5 9 O Power TCP IP USB Multi Bio Series Installation Guide V1 0 The definition of term