Home

MICROgarde l and ll Installation Instructions

image

Contents

1. LOS Introduction 3 Door and Reader Connections a MICROgarde 1 CAUTION Lock strike suppression devices 2 DIODE SUPPRESSORS ARE SUPPLIED MUST be fitted directly across all inductive loads such as lock strikes Lock PSU MG PSU secondary relays and automatic door openers Failure to adhere to this notice will see section 4 see section 4 invalidate the warranty of this product and may result in irreparable damage to it and V OV 12V GND other connected equipment Thank you for purchasing your TDSi MICROgarde access control system There are 2 main types of MICROgarde controller LOCK 1 y MICROgarde is a 1 door Fail Safe Fail Secure Connections shown are controller with for fail safe locks i e if connections for 1 2 li power fails door q X Door Sensor 1 readers unlocks If you use fail is MICROgarde II is a 2 secure locks i e if O Reader 1 gt x l inside power fails door locks aia door controller with connect the lock PSU OV O c connections for up to 4 to 13 N C instead of 11 Reader 2 i TDSi readers or 2 N O O or non TDSi readers Egress button 1 The controllers can operate independently or as part of a networked system administered from a single Bs oe ale the computer PC using the supplied MICROgarde or EXgarde o reada oe TiC RO o de PRO software In addition spare inputs and relays are Cabling and Grounding makes or ee nay available
2. Failure to do so may result in unreliable operation of the door controller 8 Press any Exit button The associated lock is 9 Tests are now complete Change the rotary switch to 5 Switching on and Testing The following tests will confirm that the controller reader s lock s and exit buttons are correctly connected Testing any door sensors requires the software to be running and will be checked as part of the software setup Set the rotary switch to 0 Power up the unit Hardware Reset set the rotary switch to the correct address 1 8 or 9 To perform a hardware reset y With MICROgarde software use 1 8 for the first 1 Turn off the MICROgarde unit eight units in a network Set additional units to 9 2 Set the dial switch to zero r With EXgarde PRO set all units to 9 3 Switch the MICROgarde unit on 4 Check that the 5V On light illuminates and that the 4 Wait 20 seconds watch for 4 green red LED on each reader flashes continuously 2 flashes on LED D8 followed by a flashes per second pause and then 8 or 9 more green 5 Present a card to any reader The flashing rate of the flashes red LED on all readers changes to once every 2 Turn the dial back to the required unit seconds number 1 to 8 or dial 9 for UID which 6 Put the unit into installer mode selects next available unit number Carry out a hardware reset see box opposite Press down the tamper switch for 5 seconds Release the
3. tamper switch for 5 seconds Press down the tamper switch for 5 seconds Release the tamper switch again for 5 seconds Press the tamper switch down again for 5 seconds g Release the tamper switch again for 5 seconds During this action Relay 1 will activate for 5 seconds and D13 red LED will light up for 5 seconds present the card the reader s LED 7 Present the card again to any reader illuminates fully to indicate access y Both Relays 1 and 2 operate for 5 seconds denied y Any locks connected to these relays are unlocked for 5 seconds y The Relay 1 and 2 red LED indicators D13 and D14 illuminate for 5 seconds regardless of the number of doors the controller will be controlling Sa After the hardware reset y The units memory is cleared The LED on any fitted reader will flash red twice a second y The first time you present a card to a reader it sets the reader into its ready mode and its LED flashes once every 2 seconds The second time you mapo The unit is ready to receive a reset and upload from the software and card validation unlocked for 5 seconds the required number 10 Re connect the communications link if necessary If MlCROgarde PC software is running the Tx and Rx lights will start flashing rapidly 11 Exit installer mode by one of the following actions y Shutdown and restart the software y Validate a card using the software y Perform a hardware reset See box opposite 1
4. 2 In Normal operation mode y The Reader LED flashes once every two seconds y When a non valid card is presented to a reader the reader LED lights up red for 5 seconds y When a valid card is presented to a reader the reader LED lights up green for 5 seconds and the corresponding lock relay will trigger 1 Relay 1 Red LED 2 Relay 2 Red LED 3 Rotary Switch 4 5V ON LED
5. a unique l E a 4 ao i y eae SuBpOr rae LOCK 1 number used by TDSi fa NUM 4 1 EE E Reader 3 and 4 option software for J sere x E 7 EXprox EXprox VR ad Door Sensor 1 identification purposes twe ae AE TEITI i we gle we Optica Optica VR A MICROgarde 1 has Et Com smiS 3 STE g te Ei i Digital IR EXprox 2 an a UID starting with 6 ka ALAE a a a utton amp A 5 Exit E L EXprox 2K a e 2 or Reader 1 3s ei tl a r w ty l anas Termination switches UP on first unit closest to PC ONLY EXsmart 2K O lt garde as a f DE t a 4 Reader 3 UID starting with 5 5 Ci ae a fy Be Makea I E odoi b E 5 a b Serial PC gt 15m from first controller or USB o aih naa O or note of your unit s UID cs of IR fit the extra brown you may need it during p wW i To PC via RS485 RS232 or USB RS485 converter T iother controllers wire to MagClock W1 Egress button 1 software installation suns be 24 amp 29 respectively as shown here For other Tamper spring TDSi readers please LOCK 2 Slot the tamper spring refer to the manual N o NT E 2 2 LO LO ep ep a ag onto the switch SW1 located near the battery on the main PCB X Door Sensor 2 Joa lsc Fail Safe Fail Secure o Y a Mage sed dE oe Connections shown are Battery e i Termination switches UP on first unit closest to PC ONLY for fail safe locks i e if O Reader 2 After installation and a
6. e to adhere to this notice will invalidate the warranty of this product and may result in irreparable damage to it and other connected equipment MICROgarde units without integral PSU If you have purchased a MICROgarde unit without an integral power supply you need to connect the unit to a suitable PSU This should be capable of supplying enough power for the controller and its readers In most cases a 1A power supply is adequate However if your installation consists of 4 Optica readers keypads and a TCP IP module you should use a 1 5A supply 1 Connect the PSU to the MICROgarde s OV and 12V terminals using braid screened cable Position the PSU as close as possible to the unit 2 To minimize electrical interference ensure that the MICROgarde and PSU are grounded together fasten the braid screen to both the main earth point in the PSU and to the chassis plate of the MICROgarde 3 Fit two suppressors across the mains input to the Neutral power supply Suitable suppressors are provided with each MICROgarde non PSU unit These are 470 pF pico Farad Class Y disc ceramic capacitors rated at 240V AC MICROgarde units with integral PSU A MlCROgarde controller with integral PSU features a high quality 2A power supply unit with separate 1A outputs for the door controller and the lock CAUTION The lock power MUST be taken from the terminal block on the PSU and not from the power terminals 7 8 9 and 10 on the MICROgarde controller
7. for monitoring and control of other equipment All communications and reader cabling runs should be in fe colour Please read the user manual for detailed information about Se Cae area ee oie the configuration of MICROgarde controllers and the use of Ore On ene ann le eee the ne a ae g the MlCROgarde chassis is connected to a good earth MagData WO Quick Start Guide l grounding 24 MagClock W1 E l Communication and other peripheral cable should only LED i Hi a are ie A enna rome gt be earthed at the MICROgarde chassis unless the item Reader 12V E T e S A a e g reader egress lock etc is mounted on an earthed OV metal surface In this case do not earth the cable at the MagData WO w MlCROgarde unit to avoid earth loops and possible 29 MagClock W1 QS001 Issue 5 Copyright 2012 TDSi interference LED Keep all unshielded cable runs and earth drain wire pig tails as short as possible To minimize exposed earth i i i i braid never remove more cable sheathing than necessary 1 Configuration 2 Communications g ry l o Lock PSU MG PSU Mounting a Direct RS232 PC within 15m of first controller see section 4 see section 4 The MICROGarde controller is designed to be mounted on flat H D surfaces while allowing cables to pass underneath 3 screws are D MICROga rde 2 2 iow 2h required to mount the chassis onto a wall i m 0 5 To other controllers Supported Readers T E oe socket viewe Only the following TDSI The UID is
8. l mys ee ET Bor fail O connection remove the L 1 ol wolt ole c TCP IP oe ees a an Reader 4 MagData WO battery tab under label yh Sle gtiza aj ig eres secure locks i e O MagClock W1 amp This Goablesthe onboard biei PE a Dedicated ink to PC use cross over lead to PC port power fails door locks or l Existing network use standard patch cable to convenient network point aih wi connect th e o ck PSU OV LED h o other controllers Gain ion TCP IP to 13 amp 19 N C instead Egress button 2 m Reader 12V for example access card l X Teen ANO OV any power loss ed Seay a coding used in TDSi readers 99 5 Other makes of reader may have a i 3 Rotary Dial switch different colour coding LED Sets number of unit in network See section 5 Termination switches UP on first unit closest to PC ONLY 4 Power Supplies For maximum reliability we recommend the use of separate power supplies for locks In most cases however using one supply for the controller and the lock s it controls will cause no problems provided the supply has sufficient current output and the cable distances do not result in significant voltage drops If in doubt use one supply for the controller and one supply for each lock CAUTION Lock strike suppression devices 2 DIODE SUPPRESSORS ARE SUPPLIED MUST be fitted directly across all inductive loads such as lock strikes secondary relays and automatic door openers Failur

Download Pdf Manuals

image

Related Search

Related Contents

[U4.83.11] Opérateur POST_RCCM  Service Manual  E1200 Servo Drive Installation Guide - LinMot e  1 Drücken Sie  TDSHーBA 東芝蛍光灯ブラケツ ト取扱説明書 保管用  JABRA ECLIPSE  Philips MP3 Mini Hi-Fi System FWM582  taxe de sejour - Office de Tourisme de Villard-de  neoDVDstandard User Manual  LC-Power Cosmo Cool LC-CC-83  