1. Sensor Protected Area Sensor Type Sensor Protected Area Sensor Type 01 33 02 34 03 35 04 36 05 37 06 38 07 39 08 40 09 41 10 42 11 43 12 44 13 45 14 46 15 47 16 48 17 49 18 50 19 51 20 52 21 53 22 54 23 55 24 56 25 57 26 58 27 59 28 60 29 61 30 62 31 63 32 64 20 Testing Your System NOTE If you are going to perform a System Test call your Monitoring Station to inform them when you begin and also when you end the test Testing Your Keypad Sounder and Siren The System Test performs a two second check of the keypad sounder and bell or siren in addition to testing the keypad status lights and the panel backup battery 1 Press Options User Functions Master Code then System Test The following will occur The system activates all keypad sounders and bells or sirens for 2 seconds All keypad lights turn ON PK5500 RFK5500 RFK5564 keypads will light all pixels The Ready Armed and Trouble LEDs will flash for the duration of the test 2 To exit the function menu press Testing Your Entire System All smoke detectors in this installation must be tested by your smoke detector installer or dealer once a year to ensure they are functioning correctly It is the user s responsibility to test the system weekly excluding smoke detectors Ensure you follow all the steps in the Testing Your Keypad Sounder and Siren section above
2. Reprogram Time amp Date 10 Alarm Memory When an alarm occurs the Memory or System indicator will turn on To view which sensor s generated the alarm press Alarms D The sensor number where the alarm occurred will be displayed e g zone 3 see Figure 10 on page 11 Use the lt gt scroll keys to view the sensors in alarm memory Press Back or Home to exit To clear the memory arm and disarm the system If an alarm sounded while armed the keypad will automatically go to alarm memory when you disarm the system In this instance you should approach with caution as the intruder may still be within the building premises Figure 10 Alarms in Memory CERERI ZONE STATUS Sensor Reset Certain sensors after having detected an alarm condition require a reset to exit the alarm condition e g glass break sensors smoke detectors etc Ask your alarm company if this function is required on your system To reset the detectors press the Reset Command Output 2 if the installer did not program a label but ton on the Outputs screen If a sensor fails to reset it may still be detecting an alarm condition If the sensor reset is successful the alarm is cancelled If unsuccessful the alarm will reactivate or continue 11 Outputs Your installer may have programmed these keys to perform various functions reset smoke detector after an alarm open your garage door etc To activate these functions press
3. NOTE Should the system fail to function properly call your installation company for service immediately 1 Prior to testing ensure that the system is disarmed and the Ready light is on 2 Close all zones to return the system to the Ready state 3 Perform a System Test by following the steps in the Testing Your Keypad Sounder and Siren section 4 To test the zones activate each detector in turn e g open each door window or walk in motion detector areas PK5500 RFK5500 RFK5564 keypads will display the following message when each zone detector is activated Secure System Before Arming lt gt Secure System or Enter Code or Secure or Arm System Use the lt gt scroll keys to view which zones are open The message will disappear when the zones are closed On a PK5501 RFK5501 keypad the display says Open when any zone detector is activated To see which zones are open press The keypad will scroll the numbers of all open zones On a PK5508 PK5516 RFK5508 RFK5516 keypad the zone light turns ON when the zone detec tor is activated The zone light turns OFF when the zone is closed e g door or window closed On a PTK5507 keypad the following message will be displayed when each zone detector is acti vated Ready to Force Not Ready Use the zone status button to view which zones are open The message will disappear when the zones are closed NOTE Some features described
4. The corresponding trouble will light up Troubles Comments Action Service Required Press for more details 1 Low Battery 2 Bell Circuit 3 General System Trouble 4 General System Tamper 5 General Sys tem Supervision 6 RF Jam Detected 7 PC5204 Low Battery 8 PC5204 AC Loss Call for service AC Loss If the building and or neighborhood has lost elec trical power the system will continue to operate on battery for several hours Call for service Phone Trouble The system has detected that the telephone line is disconnected Call for service Communication Failure The system attempted to communicate with the monitoring station but failed This may be due to Telephone Line Fault Call for service Zone Fault The system is experiencing difficulties with one or more sensors on the system Press to display the zone Call for service Zone Tamper The system has detected a tamper condition with one or more sensors on the system Press to display the zone Call for service Wireless Low Bat tery The system has detected alow battery condition with one or more modules sensors on the system Press to display the zone keypad wireless key s and RF Delinquency low battery conditions Press again to see zone troubles Call for service Loss of Clock If complete power was lost AC and Battery the time and date will need to be reprogrammed
5. that can be heard from the exterior of the premises When Alarm Sounds The system can generate 4 different alarm sounds Temporal pulsed siren Fire Alarm 4 beeps 5 second pause 4 beeps Carbon Monoxide Alarm Continuous siren Intrusion Burglary Alarm NOTE The priority of signals is fire alarm carbon monoxide alarm then burglary alarm 5 Intrusion Burglary Alarm Continuous Siren Q If you are unsure of the source of the alarm approach with caution If the alarm was acciden tal enter your Access Code to silence the alarm Call your central station to avoid a dispatch Fire Alarm Pulsed Siren A Follow your emergency evacuation plan immediately Tf the fire alarm was accidental e g burned toast bathroom steam etc enter your Access Code to silence the alarm Call your central station to avoid a dispatch Ask your alarm company if your system has been equipped with fire detection To reset the detectors see the Sensor Reset section Wireless Carbon Monoxide Alarm Activation of your CO alarm indicates the presence of carbon monoxide CO which can be fatal Dur ing an alarm the red LED on the CO detector flashes rapidly and the buzzer sounds with a repeating cadence of 4 quick beeps 5 second pause 4 quick beeps Also during an alarm the siren connected to the control panel produces a repeating cadence of 4 quick beeps 5 second pause 4 quick beeps The keypad will also provide audible and visual indicat
6. B of Part 15 of FCC Rules which are designed to provide reasonable protection against such interference in any residential installation However there is no guarantee that interference will not occur in a particular installation If this equipment does cause interference to television or radio reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following mea sures Re orient the receiving antenna Relocate the alarm control with respect to the receiver Move the alarm control away from the receiver Connect the alarm control into a different outlet so that alarm control and receiver are on different circuits If necessary the user should consult the dealer or an experienced radio television technician for additional sugges tions The user may find the following booklet prepared by the FCC helpful How to Identify and Resolve Radio Television Interference Problems This booklet is available from the U S Government Printing Office Washing ton D C 20402 Stock 004 000 00345 4 This Class B digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe B est conforme la norme NMB 003 du Canada This product contains open source components QT Version 4 7 3 and Linux Kernel License Version 2 6 Both of these components are protected by copyright and have terms and conditions associated with their use
7. The open source software code and associated components used in this product are downloadable from the DSC web site Please visit http www dsc com open source documentation for detailed information 2012 Tyco International Ltd and its Respective Companies All Rights Reserved Toronto Canada www dsc com Printed in Canada The trademarks logos and service marks displayed on this document are registered in the United States or other countries Any misuse of the trademarks is strictly prohibited and Tyco International Ltd will aggressively enforce its intellectual property rights to the fullest extent of the law including pursuit of criminal prosecution wherever necessary All trademarks not owned by Tyco International Ltd are the property of their respective owners and are used with permission or allowed under applicable laws Product offerings and specifications are subject to change without notice Actual products may vary from photos Not all products include all features Availability varies by region contact your sales representative
8. door is closed again the remaining exit time is cancelled Time amp Date Programming Tap on Options Select User Functions Master Code and then select Time amp Date Tap on the section you would like to change and use the up down arrows to change time date Once done press Save Keypad Mode This option allows the PTK5507 Touchscreen to function as a traditional DSC keypad Door Chime Chime enable disable The keypad indicates the current state of the door chime function Enabled or Disabled To choose the opposite function tap the Chime icon Three beeps indicate that the chime is ON Enabled One long beep indicates that chime is OFF Disabled Zone Status This screen allows you to view the status of the zones on the system Figure 5 Zone Closed Zones are Closed Restored Ready the zone is closed See Figure 5 on page 7 Open the zone is open and needs to be closed See Figure 6 on page 7 Figure 6 Zone Open Zone is Open Trouble the alarm panel has detected a technical problem with one or more components of the alarm system e g loss of AC power See Troubles on page 10 Fault one or more of the zones on your system is not secure e g a window or door is open See Fig ure 7 on page 8 Figure 7 Zone Fault ZONE STATU Tamper the zone may have been compromised by an intruder See Figure 8 on page 8 Figure 8 Zone Tamper Tamper Ctp LUI Low Batter
9. minutes Tap the screen to restore the dis play Disarm If Disarm is selected A numerical keypad is displayed Enter your Access Code in the keypad The system returns to the Home screen and the red Armed indicator turns OFF The alarm status is momentarily displayed in the status bar then Ready is displayed The green Ready indicator turns ON Disarming Error If your code is invalid the system will not disarm and a 2 second error tone will sound If this happens press and try again Away Arm When Away Arm is selected Enter a valid access code to proceed The Armed LED Indicator turns ON Exit Delay in Progress is displayed in the Status Bar The pre programmed exit delay begins The touchscreen beeps at a 1 second urgency interval during the exit delay Then 3 beeps sound in the last 10 seconds NOTE If Quick Arm is not enabled by the installer a numerical keypad is displayed If Disarm is selected during the exit delay A numeric keypad is displayed Tap your access code The Arming sequence is aborted and the system returns to the Home screen The Armed LED turns OFF At the end of the pre programmed exit delay The Disarm screen is displayed The Ready Indicator turns OFF Away Armed is displayed in the Status Bar Bell Siren Sounds After Away Arming Audible Exit Fault In an attempt to reduce false alarms the Audible Exit Fault is designed to notify you of an improper exit when ar
10. this feature enabled the panel will automatically arm in the Away mode Stay Away zones active or disarm at the same time each day The Auto Arm time is programmed with the Auto Arm time button Auto Disarm must be programmed by the system installer User Call up If enabled by the installer the panel will make 1 attempt to call the downloading computer The down loading computer must be waiting for the panel to call before downloading can be performed Keypad Configuration Figure 13 Keypad Configuration Clean Mode Picture Frame Home Page tt Calibration Language S Emergency Backlight sets the brightness and screen timeout of the Touchscreen Buzzer Control sets the buzzer volume of the Touchscreen Picture Frame selects the pictures that will be displayed on the slideshow Calibration calibrates the Touchscreen Clock Mode displays the digital clock 15 Clean Mode allows the user to touch i e clean the screen without enabling or disabling any func tions The screen will remain in this mode for 30 seconds See Figure 14 on page 16 then return to the Keypad Configuration screen See Figure 13 on page 15 Figure 14 Clean Mode Clean Mode in Proaress Options 9 Home Page can be configured in one of two different views Classic square buttons and Contempo rary rondel Language allows the user to select different languages in which messages can be displayed Figu
11. upon Arming 3 Zone Bypassing Enabled Disarming 4 ESCORT Access 8 One Time Use Code Bell Squawk Attribute This attribute is used to determine whether an access code should generate an arming disarming Bell Squawk upon entry of the code for Away arming The wireless keys with access codes associated with them may generate Arming Disarming Bell squawks If desired this option may be used with codes that are manually entered Please contact your installer to have this programmed NOTE The Master Code cannot use the Bell Squawk attribute but is required to enable it for other codes NOTE This feature cannot prevent the Arming Disarming squawks from being generated if an access code assigned to a wireless key is manually entered at a keypad Partition Assignment Mask The master code has access to all partitions and cannot be modified 13 Partition Assignment Mask 5 Master Supervisor Code 98 Code Partition One Access available for PC1616 PC1832 PC1864 Partition Two Access available for PC1616 PC1832 PC1864 Partition Three Access available for PC1832 PC1864 Partition Four Access available for PC1832 PC1864 Partition Five Access available for PC1864 Partition Six Access available for PC1864 Partition Seven Access available for PC1864 Partition Eight Access available for PC1864 Notes on Access Codes and Programming SN DAMNARYN H 1 The master code s attributes cannot be changed 2 When a new cod
12. 35 bb e EEE EEE Re icon gue es 4 Ready Armed Trouble AC Dimensions mounting 8 5 x 5 1 x 0 8 127 9 mm L x 195 mm W x 20 35 mm D S VIEWING angles vss av WES ew rUC exe NRI Ie os eee S Horizontal viewing angle 70 typ Vertical viewing angle 50 top 70 bottom typ Brightness c ves Ex Mp ERRREREENRENUUCCUUCUL OH HH E E Case E EE CKES 280 cd m e Operating environment ssssssseee rennene 10 C to 55 C 14 F to 131 F 5 to 93 relative humidity SD card slot holds any standard Secure Digital SD card 32 x 24 x 2 1 mm containing photos Display language s ioe eaae ina e epo Dr nh pet ue de RR ROS wae Re nate English f necessary the SD card can be formatted to file system FAT16 or 32 using a PC The maximum size SD card supported is 32GB NOTE For best results photo resolution should be 800 x 480 please use photo editing computer software to adjust your photos to the correct size Photos larger than 1280 x 720 cannot be displayed by the Touchscreen Welcome Screen The date amp time are displayed in the upper right corner of the screen The system status i e Ready Armed Exit Delay etc is displayed at the top of the screen Figure 1 Welcome Screen System Status Zone Status Chime ON OFF e Command Outputs Dedit e Keypad Securit oat Functions terer Emergency Key Keypad Mode QuickExit Photo Frame Emergency Key Figure 2 Emergency Screen Hod
13. N ITS BEHALF TO MODIFY OR TO CHANGE THIS WARRANTY NOR TO ASSUME FOR IT ANY OTHER WARRANTY OR LIABILITY CONCERNING THIS SOFTWARE PRODUCT e EXCLUSIVE REMEDY AND LIMITATION OF WARRANTY UNDER NO CIRCUMSTANCES SHALL DSC BE LIABLE FOR ANY SPECIAL INCIDENTAL CONSEQUENTIAL OR INDIRECT DAMAGES BASED UPON BREACH OF WARRANTY BREACH OF CONTRACT NEGLIGENCE STRICT LIABILITY OR ANY OTHER LEGAL THEORY SUCH DAMAGES INCLUDE BUT ARE NOT LIMITED TO LOSS OF PROFITS LOSS OF THE SOFTWARE PRODUCT OR ANY ASSOCIATED EQUIPMENT COST OF CAPITAL COST OF SUBSTITUTE OR REPLACEMENT EQUIPMENT FACILITIES OR SERVICES DOWN TIME PURCHASERS TIME THE CLAIMS OF THIRD PARTIES INCLUDING CUSTOMERS AND INJURY TO PROPERTY WARNING DSC recommends that the entire system be completely tested on a regular basis However despite frequent testing and due to but not limited to criminal tampering or electrical disruption it is possi ble for this SOFTWARE PRODUCT to fail to perform as expected FCC Compliance Statement CAUTION Changes or modifications not expressly approved by DSC could void your authority to use this equipment This equipment generates and uses radio frequency energy and if not installed and used properly in strict accor dance with the manufacturer s instructions may cause interference to radio and television reception It has been type tested and found to comply with the limits for Class B device in accordance with the specifications in Subpart
14. Output and then press the appropriate option See also Sensor Reset on page 11 Figure 11 Outputs OUTPUTS command O P 3 Command O P 4 Options From the Options menu on the right side of the Touchscreen see Figure 12 on page 12 the following can be accessed Access Codes Installer Menu User Functions Keypad Config Chime Enabled Disabled Arming Partition Status Keypad Mode Figure 12 Options OPTIONS Chime Disabled Arming User Functions Partition Status Keypad Config Keypad Mode 12 Access Codes When Access Codes is selected from the Options menu the keypad prompts for a Master Code When a valid Master Code is entered a numeric keypad is displayed with arrows to scroll to the desired user to add edit Press the select button to enter the user options Set Access Code adds edits the 4 digit code Set Partitions assigns the user to partitions User Options enables disables different options for the user Delete User deletes the user from the system The access codes have programmable attributes which allow zone bypassing remote access using the ESCORTS5580TC or one time use activation Master Code Access Code 40 The master code if programmed can only be changed by the installer Supervisor Codes These codes can be used to program additional codes which have equal or lesser attributes Once programmed the supervisor codes receive the master code
15. PTK5507 v1 0 Touchscreen User Manual WARNING This manual contains information on limitations regarding product use function and information on the limitation as to liability of the manufacturer The entire manual should be carefully read DSC CE A Tyco Internationa Company Table of Contents WelcomeiSCteen oos ex tee subs ru teer Sonde Se wee RCHN e Ce ape 2 Emergency Keys ler vue Ion FORNE ec eve rd erede qus 2 Arming and Disarming the System llle lees 3 Stay Arm Arming the Perimeter 0 0000000002 eee 3 Silent Exit Delay ever tte e er GM ee ANE ele ate ee Pec n e e tI ne a 3 DISAIS eorr e ee E RM OU CHO o e diets s e e Ot pte 5 AWAY ATIN S iru feeit e ORE DE UNUS POHEQUI pas ere P S get me Decet 5 Bell Siren Sounds After Away Arming 0 000000 0000 2 Remote Arming and Disarming lsseeeseeeeeeeeeee 5 When Alarm Sounds enr doa ole pw eoe eg EUR A 5 Intrusion Burglary Alarm Continuous Siren 0 000 6 Fire Alarm Pulsed Siren 00 0 0c eee eee ences 6 Wireless Carbon Monoxide Alarm 1 0 0 0 c eee ee eee eee eee 6 Additional Options 02 0 0 0 00 6 dion I 6 nid dosi MEI 6 Time amp Date Programming 0 00 cece een 6 Keypad Mode 1 ove sre ooh Tar Chr e Io e Tp Ca rece 6 Door Chime Chime enable disable llis esless 6 ZONE Stats ser Leche RE ERR E aH IRE E RERO le 7 Bypassed Zones i ts winters ata ea
16. Your Systemie een ep y nea e Gul TR ERR gana 21 Testing Your Keypad Sounder and Siren 00 0000 21 Testing Your Entire System 10 0 0 eee eee eee eee 21 Walk Test Mode oe Re A ERR bie awe ee eA ENER ORE OO EM 21 Allowing Computer Access To Your System 0000 21 Always ensure you obtain the latest version of the User Guide Updated versions of this User Guide are available by con tacting your distributor NOTE Use these instructions in conjunction with the Installation Manual of the alarm panel with which this equipment is intended to be used WARNING Read and save these instructions Follow all warnings and instructions specified within this document and or on the equipment IMPORTANT SAFETY INSTRUCTIONS To reduce the risk of fire electric shock and or injury observe the following Donot spill any type of liquid on the equipment Donot attempt to service this product yourself Opening or removing the cover may expose you to dangerous volt age or other risk Refer servicing to qualified service personnel Never open the device yourself Donot touch the equipment and its connected cables during an electrical storm there may be a risk of electric shock e Donot use the Alarm System to report a gas leak if the system is near a leak REGULAR MAINTENANCE AND TROUBLESHOOTING Keep your PTK5507 Touchscreen keypad in optimal condition by following all the instructions that are included wi
17. above will not be functional unless enabled by your installer Ask your installer which features are functional on your system Walk Test Mode The installer can initiate a Walk Test mode for the system While in Walk Test mode the Ready Armed and Trouble LEDs will flash to indicate that Walk Test is active When the system automati cally terminates the Walk Test mode it will annunciate with an audible warning 5 beeps every 10 sec onds beginning five minutes prior to the termination of the test Allowing Computer Access To Your System From time to time your installer may need to send information to or retrieve information from your security system Your installer will do this by having a computer call your system over the telephone line You may need to prepare your system to receive this downloading call To do this 1 Press 6 Master code 5 at any keypad or 2 Press Options User Functions Master Code then Enable DLS from the Touchscreen This allows downloading for a limited period of time During this time the system will answer incom ing downloading calls For more information on this feature please ask your installer 21 IMPORTANT READ CAREFULLY DSC Software purchased with or without Products and Components is copyrighted and is purchased under the following license terms This End User License Agreement EULA is a legal agreement between You the company individ ual or entity who ac
18. e is programmed in User Programming it will be checked against all other codes in the system If a duplicate code is found an error tone is given and the code is returned to what it was before it was changed This applies to both 4 and 6 digit codes Erasing an Access Code To erase a code select the code and choose Delete User The system will delete the code immediately and the user will be returned to select another code Installer Menu These functions are for the installer s use only User Functions First disarm the system then enter Options User Functions then Master Code This command is used to gain access to the following list of master functions of the system Time and Date Enter desired time and date Auto Arm Time The system can be programmed to arm at a programmed time each day per partition Upon entry of this section enter the desired Auto Arm time for each day of the week At the selected Auto Arm time the keypad buzzers will sound for a programmed amount of time pro grammable by the installer only to warn that an auto arm is in progress The bell can also be pro grammed to squawk once every 10 seconds during this warning period When the warning period is complete the system will arm with no exit delay and in the Away Mode Auto Arming can be cancelled or postponed by entering a valid access code only during the pro grammed warning period Auto Arming will be attempted at the same time the next day When the Au
19. end user within this equipment WARNING Never obstruct the access to the Alarm controller to which this equipmentis connected These safety instructions should not prevent you from contacting the distributor and or the manufacturer to obtain any further clar ification and or answers to your concerns IMPORTANT NOTICE A security system cannot prevent emergencies It is only intended to alert you and if included your central station of an emergency situation Security systems are very reliable but they may not work under all conditions and they are not a substitute for prudent security practices or life and property insurance Your security system should be installed and serviced by qualified security professionals who should instruct you on the level of protection that has been provided and on system operations Introduction The PTK5507 Touchscreen is an interactive touch sensitive color LCD that can be used on any Power Series v4 2 and greater control panel Due to the custom requirements of individual installations some of the features described here may perform differently than described Refer to your Installer s Instruc tions for the details of your specific installation and to the User Manual for general security system information Specifications F eatures Displays aa e e a NIRE d did ii in 7 TFT 800 x 480 pixel Color Touchscreen Home Dutt ooo oet bOCCGCUUGCC ERPREREPRERE EE Home Calibration Reset LED indicators fii e5
20. f and Ready f indicators turn on to visually indicate that the system is arming When the exit delay expires the Ready LED turns off the Armed LED remains on and the keypad stops sounding to indicate that the alarm system is armed NOTE For SIA FAR listed panels the Stay Arming exit delay will be twice as long as the Away Arming exit delay Silent Exit Delay If the system is armed using the Stay Arm button or using the No Entry Arming method 9 access code the audible progress annunciation keypad buzzer is silenced and the exit time doubled for that exit period only CP 01 versions only NOTE For non CP 01 versions Standard exit time is used When Stay Arm is selected from the Home screen The display indicates Exit Delay in Progress and the pre programmed exit delay begins The Armed LED Indicator turns on NOTE If Quick Arm is not enabled by the installer then a numerical keypad is displayed see Figure 4 Enter a valid access code to proceed Figure 4 Keypad Enter User Code If Disarm is selected during the exit delay a numeric keypad is displayed Enter tap your access code The arming sequence is aborted and the system returns to the Home screen The Armed LED turns OFF At the end of the pre programmed exit delay The Disarm screen is displayed The Ready Indicator turns OFF Stay Armed Bypass is displayed in the Status Bar NOTE This screen will go into stand by mode after 15
21. ion of the CO alarm If an alarm sounds 1 Operate silence button 2 Call emergency services or your fire department 3 Immediately move outdoors or to an open door window WARNING Carefully review your Carbon Monoxide Installation User Guide to determine the necessary actions required to ensure your safety and ensure that the equipment is operating cor rectly Incorporate the steps outlined in the guide into your evacuation plan Additional Options Photos NOTE For best results photo resolution should be 800 x 480 please use photo editing computer software to adjust your photos to the correct size Photos larger than 1280 x 720 cannot be dis played by the Touchscreen When Photos is selected The photos play automatically from the list of photos on your SD card Tapping the screen once will bring you back to the home page Photo Settings WARNING Disassembling the keypad without first removing the SD card will cause damage to the unit Selecting Picture Frame from the Keypad Configuration menu will allow you to select the pictures for the slide show You can also program the Transition Time between photos and the duration for the Photo Frame Timeout on this screen Quick Exit If the system is armed and you need to exit use the quick exit function to avoid disarming and rearming the system To activate this function tap the Quick Exit icon You have 2 minutes to leave the premises through your exit door When the
22. ming the system in the Away mode In the event that you fail to exit the premises during the allotted exit delay period or if you do not securely close the Exit Entry door the system will notify you that it was improperly armed in two ways the keypad will emit one continuous beep and the bell or siren will sound Your installer will tell you if this feature has been enabled on your system If this occurs Re enter the premises 2 Enter your access code to disarm the system You must do this before the entry delay timer expires 3 Follow the Away arming procedure again making sure to close the entry exit door properly Arming Error An error tone will sound if the system is unable to arm This will happen if the system is not ready to arm i e sensors are open or if an incorrect user code has been entered If this happens ensure all sen sors are secure Press and try again ensuring that a valid access code is entered Please check with your installer to determine if arming is inhibited by any other means Remote Arming and Disarming The system can be armed and or disarmed using the remote wireless key When arming the system by using the Arm button on the wireless key the system will acknowledge the command by sounding a sin gle bell squawk if bell squawk is enabled When disarming using the Disarm button on the wireless key the system will acknowledge the command by sounding two bell squawks if bell squawk is enabled
23. puitontor two seconds AGMVGLe alarm Outputs zt a Options J When the emergency key is pressed a new page will appear with Fire Fire Assistance Required Press and hold for 2 seconds to activate Ambulance Medical or other Assistance Required Press and hold for 2 seconds to activate Panic Police Assistance Required Press and hold for 2 seconds to activate IMPORTANT NOTE The Ambulance and Panic keys are ON by default The Fire key will not function unless programmed by the Installer Please ask your installer if the Fire Ambulance and Panic keys are enabled NOTE These events are recorded in the log Figure 3 Controls amp Indicators Stay Arm System Status Partition Status Time Date Trouble Menu Global Arm Command Output Keypad Security Functions Emergency Key Zone Status Photo Frame Ready Armed Home Trouble AC LED LED Reset LED LED SD card slot Arming and Disarming the System Stay Arm Arming the Perimeter Ask your alarm company if this function is available on your system Stay arming bypasses the interior protection i e motion sensors and arms the perimeter of the system i e doors and windows Close all sensors i e stop motion and close doors The Ready v indica tor should be on Press the Stay Arm button and or enter your Access Code and do not leave the prem ises if your installer has programmed this button During exit delay the Armed
24. quired the Software and any related Hardware and Digital Security Controls a division of Tyco Safety Products Canada Ltd DSC the manufacturer of the integrated security systems and the developer of the software and any related products or components HARDWARE which You acquired If the DSC software product SOFTWARE PROD UCT or SOFTWARE is intended to be accompa nied by HARDWARE and is NOT accompanied by new HARDWARE You may not use copy or install the SOFTWARE PRODUCT The SOFTWARE PRODUCT includes computer software and may include associated media printed materials and online or electronic documentation Any software provided along with the Software Prod uct that is associated with a separate end user license agreement is licensed to You under the terms of that license agreement By installing copying downloading storing access ing or otherwise using the Software Product You agree unconditionally to be bound by the terms of this EULA even if this EULA is deemed to be a modifica tion of any previous arrangement or contract If You do not agree to the terms of this EULA DSC is unwilling to license the Software Product to You and You have no right to use it SOFTWARE PRODUCT LICENSE The SOFTWARE PRODUCT is protected by copyright laws and international copyright treaties as well as other intellectual property laws and treaties The SOFTWARE PRODUCT is licensed not
25. r e A PEOR rt ga Ant DAD SE ORAL ats 9 Bypassing Zones with a PTK5507 0 2 ee een 9 TODI to etc eeu ru ee hee Suge Sas whys 10 Alarm Memory testet tes dee persto TROU estre rege ehe e ute s 11 Sensor Resetuo E uy sates tud ues catia Ponce tw FRU NES sosta Sellen eu 11 Outputs arara ureeoee tav ew iu ure eee PER IS AY ww 12 OPTIONS 5er de ere t Ut de er Mee Phong ten ace teen 12 Access Codes ve UAR RS ee See ne OEC TEES SEs 13 User Code Attributes ve ERE eI DLE a e RS an 13 Inherent Attributes all codes except installer and maintenance 13 Programmable Attributes 0 00 eee eee eee 13 Bell Squawk Attribute isre 0 cece ce eee en 13 Partition Assignment Mask sss 13 Erasing an Access Coder areen ienr re ccc cee eee ee 14 Installer Menu user Re Sese RERO ele RU PN te eect Neeley 14 Uset FUnctions sue se mee 4 hen ne E CVVer eI ule vota 14 Keypad Configuration ees 15 Chime Enabled Disabled 0 cee eee eee ene ee 16 Afming elb MUR eSIESY e ANS Poe elias Gk ck See e SE 16 Partition Status ice ep RR E ER ee s eed 17 PK5500 RFK5500 RFK5564 PTK5507 Global Status Screen 17 Keypad Mod t 0 xo eremi tece er etude a o ea a fe uete yale 17 Reference Sheets 00 0 0 ccc cece eee 18 System Information a ip a A eee eee eee 18 ACCESS CodeS ec aig Bead Aisi ea acai aba ar RARUS NEUE VERE mend he ed 19 Sensor Zone Information 0 0 cece eee eee ene 20 Testing
26. ration shall be English 7 LIMITED WARRANTY a NO WARRANTY DSC PROVIDES THE SOFTWARE AS IS WITHOUT WARRANTY DSC DOES NOT WARRANT THAT THE SOFTWARE WILL MEET YOUR REQUIREMENTS OR THAT OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR FREE b CHANGES IN OPERATING ENVIRONMENT DSC shall not be responsible for problems caused by changes in the operating characteristics of the HARDWARE or for problems in the interaction of the SOFTWARE PRODUCT with non DSC SOFTWARE or HARDWARE PRODUCTS c LIMITATION OF LIABILITY WARRANTY REFLECTS ALLOCATION OF RISK IN ANY EVENT IF ANY STATUTE IMPLIES WARRANTIES OR CONDITIONS NOT STATED IN THIS LICENSE AGREEMENT DSC S ENTIRE LIABILITY UNDER ANY PROVISION OF THIS LICENSE AGREEMENT SHALL BE LIMITED TO THE GREATER OF THE AMOUNT ACTUALLY PAID BY YOU TO LICENSE THE SOFTWARE PRODUCT AND FIVE CANADIAN DOLLARS CAD 5 00 BECAUSE SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES THE ABOVE LIMITATION MAY NOT APPLY TO YOU d DISCLAIMER OF WARRANTIES THIS WARRANTY CONTAINS THE ENTIRE WARRANTY AND SHALL BE IN LIEU OF ANY AND ALL OTHER WARRANTIES WHETHER EXPRESSED OR IMPLIED INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND OF ALL OTHER OBLIGATIONS OR LIABILITIES ON THE PART OF DSC DSC MAKES NO OTHER WARRANTIES DSC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON PURPORTING TO ACT O
27. re 15 Language Outputs 3 tt Opens tm Chime Enabled Disabled Door chime To turn the door chime function On Off tap the Chime icon There are 3 beeps to indicate that the chime is ON 1 long beep to indicate the chime is OFF Arming Stay Arm arms the system in Stay mode Away Arm arms the system in Away mode Night Arm To fully arm the system when it has been armed in Stay Mode press Night Arm button All interior zones will now be armed except for devices programmed as Night Zones Night zones are only armed in Away mode This permits limited movement within the premises when the system is fully armed Ensure that your installer has provided you with a list identifying zones programmed as night 16 zones When the interior zones have been activated i e Night Arm you must enter your access code to disarm the system to gain access to interior areas that have not been programmed as night zones Quick Exit see Quick Exit on page 6 Global Away Arm arms all partitions to which the User Code is assigned in Away mode Global Stay Arm arms all partitions to which the User Code is assigned in Stay mode No Entry Arm arms the system with no entry Partition Status To view the partition status press Options User Functions then Partition Status The keypad shows basic status for up to 8 partitions depending on the configuration of your system Each partition is iden tified along
28. rights in connection with any trademarks or service marks of DSC or its suppliers 3 COPYRIGHT All title and intellectual property rights in and to the SOFTWARE PRODUCT including but not limited to any images photographs and text incorporated into the SOFTWARE PRODUCT the accompanying printed materials and any copies of the SOFTWARE PRODUCT are owned by DSC or its suppliers You may not copy the printed materials accompanying the SOFTWARE PRODUCT All title and intellectual property rights in and to the content which may be accessed through use of the SOFTWARE PRODUCT are the property of the respective content owner and may be protected by applicable copyright or other intellectual property laws and treaties This EULA grants You no rights to use such content All rights not expressly granted under this EULA are reserved by DSC and its suppliers 4 EXPORT RESTRICTIONS You agree that You wil not export or re export the SOFTWARE PRODUCT to any country person or entity subject to Canadian export restrictions 5 CHOICE OF LAW This Software License Agreement is governed by the laws of the Province of Ontario Canada 6 ARBITRATION All disputes arising in connection with this Agreement shall be determined by final and binding arbitration in accordance with the Arbitration Act and the parties agree to be bound by the arbitrator s decision The place of arbitration shall be Toronto Canada and the language of the arbit
29. s attributes These attributes are changeable Any user code can be made a supervisor code by enabling User Code Attribute 1 please see below for details Duress Codes Duress codes are standard user codes that transmit the Duress Reporting Code when entered to perform any function on the system Any user code can be made a duress code by enabling User Code Attribute 2 please see below for details NOTE Duress codes are not valid when entering User Programming Master Functions or Installer s sections NOTE Access codes cannot be programmed as a duplicate or as a Code 1 User Code Attributes 1 The default attributes of a new code will be the attributes of the code used to enter User Pro gramming whether it is a new code or an existing code being programmed 2 System Master Code 40 has partition access for all partitions as well as attributes 3 4 ON by default NOTE These attributes are not changeable Inherent Attributes all codes except installer and maintenance Arm Disarm Any access code with partition access enabled will be valid for arming and disarming that partition Command Outputs 7 1 7 2 1 7 3 and 7 4 If these outputs require access code entry any Access Code with partition access will be valid for performing the command output functions on that partition Programmable Attributes 1 Supervisor Code 5 For Future Use 2 Duress Code 6 For Future Use 7 Bell Squawk
30. sold 1 GRANT OF LICENSE This EULA grants You the following rights a Software Installation and Use For each license You acquire You may have only one copy of the SOFTWARE PRODUCT installed b Storage Network Use The SOFTWARE PRODUCT may not be installed accessed displayed run shared or used concurrently on or from different computers including a workstation terminal or other digital electronic device Device In other words if You have several workstations You will have to acquire a license for each workstation where the SOFTWARE will be used c Backup Copy You may make back up copies of the SOFTWARE PRODUCT but You may only have one copy per license installed at any given time You may use the back up copy solely for archival purposes Except as expressly provided in this EULA You may not otherwise make copies of the SOFTWARE PRODUCT including the printed materials accompanying the SOFTWARE 2 DESCRIPTION OF OTHER RIGHTS AND LIMITATIONS a Limitations on Reverse Engineering Decompilation and Disassembly You may not reverse engineer decompile or disassemble the SOFTWARE PRODUCT except and only to the extent that such activity is expressly permitted by applicable law notwithstanding this limitation You may not make any changes or modifications to the Software without the written permission of an officer of DSC You may not remove any proprietary notices marks or labels from the Software Product Yo
31. thin this manual and or marked on the product HANDLING PRECAUTIONS Do not apply excessive force to the display surface or the adjoining areas since this may cause the color tone to vary CLEANING e If the display surface is contaminated breathe on the surface and gently wipe it with a soft dry cloth If still not completely clean moisten cloth with isopropyl alcohol Do not use abrasives water thinners solvents or aerosol cleaners spray polish any aromatic solvents ketones etc that may enter through holes in the PTK5507 Touchscreen keypad and cause damage TROUBLESHOOTING Occasionally you may have a problem with your system If this happens your Alarm Controller will identify the problem and display an error message Refer to the provided list when you see an error message on the display If additional help is required contact your distributor for service WARNING This equipment PTK5507 Touchscreen keypad shall be installed and used within an environment that provides the pollution degree max 2 and over voltages category Il non hazardous locations indoor only It is designed to be installed serviced and or repaired by service persons only service person is defined as a person having the appro priate technical training and experience necessary to be aware of hazards to which that person may be exposed in per forming a task and of measures to minimize the risks to that person or other persons There are no parts replaceable by the
32. to Arming process is cancelled or postponed the Auto arm Cancellation Reporting Code will be transmitted if programmed If arming is inhibited by one of the following the Auto Arm Cancellation transmission will be commu nicated AC DC Inhibit Arm Latching System Tampers Zone Expander Supervisory Fault Enable DLS Allow System Service If enabled the installer will be able to access Installer Programming via remote DLS In case of DLS access this provides a window where rings will be detected by the panel The DLS window will remain open for 6 hrs during which time the installer will be able to enter DLS an unlimited number of times After the 6 hr window has expired Installer s Programming will be unavailable again until the window is re opened Event Buffer Displays the date time and the full description of the event The Log is organized from the most recent event Top to past events Down The Left arrow scrolls forward in time The Right arrow scrolls back in time The Back returns you to the Home screen This screen will time out to the Home screen after 30 seconds of inactivity 14 System Test The system s Bell Output 2s Keypad Lights and Communicator are tested This test will also measure the panel s standby battery Auto Arm Disarm Control Pressing Auto Arm while in the User Function menu will enable three beeps or disable one long beep the Auto Arm and Auto Disarm feature by partition With
33. u shall institute reasonable measures to ensure compliance with the terms and conditions of this EULA b Separation of Components The Software Product is licensed as a single product Its component parts may not be separated for use on more than one HARDWARE unit c Single INTEGRATED PRODUCT If You acquired this SOFTWARE with HARDWARE then the SOFTWARE PRODUCT is licensed with the HARDWARE as a single integrated product In this case the SOFTWARE PRODUCT may only be used with the HARDWARE as set forth in this EULA d Rental You may not rent lease or lend the SOFTWARE PRODUCT You may not make it available to others or post it on a server or web site e Software Product Transfer You may transfer all of Your rights under this EULA only as part of a permanent sale or transfer of the HARDWARE provided You retain no copies You transfer all of the SOFTWARE PRODUCT including all component parts the media and printed materials any upgrades and this EULA and provided the recipient agrees to the terms of this EULA If the SOFTWARE PRODUCT is an upgrade any transfer must also include all prior versions of the SOFTWARE PRODUCT f Termination Without prejudice to any other rights DSC may terminate this EULA if You fail to comply with the terms and conditions of this EULA In such event You must destroy all copies of the SOFTWARE PRODUCT and all of its component parts g Trademarks This EULA does not grant You any
34. with its current status PK5500 RFK5500 RFK5564 PTK5507 Global Status Screen A keypad normally assigned to a partition can be temporarily assigned loaned to Global mode in order to program functions that affect the entire system and not just one partition Figure 16 on page 17 is an example of a keypad loaned to Global mode Figure 16 Partition Status PARTITION STATUS amp SELEC Com Keypad Mode This option allows the PTK5507 Touchscreen to function as a traditional DSC keypad 17 Reference Sheets Fill out the following information for future reference and store this guide in a safe place System Information Enabled J F FIRE A AUXILIARY P PANIC fuz The Exit Delay Time is seconds 3k The Entry Delay Time is seconds For Service Central Station Information Account Telephone Installer Information Company Telephone Battery Installation Service Date If you suspect a false alarm signal has been sent to the central monitoring station call the Q station to avoid an unnecessary response 18 Access Codes PC1616 PC1832 PC1864 Master Code 40 E 1E IEEE IPIE 01 13 25 42 02 14 26 03 15 27 04 16 28 05 17 29 06 18 30 07 19 31 08 20 32 09 21 33 10 22 34 11 23 40 12 24 41 19 Sensor Zone Information
35. y one or more modules in the zone has a low battery See Figure 9 on page 9 Figure 9 Low Battery 3 19p LI Toren d I Bypassed Zones Use the zone bypass feature when a zone is open but the system needs to be armed Bypassed zones will not cause an alarm when opened Bypassing zones reduces the level of security If you are bypassing a zone because it is not functioning call a service technician immediately so that the problem can be resolved and your system returned to proper working order Ensure that no zones are unintentionally bypassed when arming your system Zone bypassing can only be performed while the system is disarmed Bypassed zones are automatically cancelled each time the system is disarmed and must be bypassed again if required before the next arming NOTE 24 hour zones can only be unbypassed manually NOTE For security reasons your installer has programmed the system to prevent certain zones from being bypassed e g smoke detectors Bypassing Zones with a PTK5507 When in the Zone Status page scroll up down through the desired zones and tap on the bypass icon to bypass the zone To unbypass a zone tap the unbypass icon Troubles When a trouble condition is detected the Trouble or System indicator will turn on and the keypad will beep every 10 seconds Press the Ay key to silence the beeps Press to view the trouble con dition The Trouble A or System indicator will flash