1. freely the adjustment of obstruction force is completed NOTE If the gate fails to reverse in the event of obstruction Then the opening force or closing force should be checked for conformity with requirements and adjusted if necessary The gate will reverse if obstructed when closing and will stop if jammed when opening e Learn Erase Remote Controls o Press red learn button on the control board then the LED will turn on It will turn off when you press any button on the transmitter Press the same button and the LED will flash at 2Hz frequency If it fails to learn the LED will turn off automatically after flashing for 1 second o To erase all remote controls press and hold the red button on the control board until the LED stops flashing After 1 second it will flash again This indicates that the remote controls have been erased completely e Install the External Keypad Button Switch See Table 3 o The port GND is the common port the port K is used to open the gate G is used to close the gate and T is used to stop the gate Note Ifthe gate running direction is not correct please change wires V1 and W1 or V2 and W2 If the wiring between two gates is wrong and the gates cannot work please check the wiring between U1 V1 W1 and U2 V2 W2 Fig 10 Control Board En Be RAD Cac na ell fes eee a ae
2. GatekeeperLtd www gatekeeperltd com LL ii yi ANNAA TAAA Pan neet SREEEGARERE EEE S PER eee Guard Your Yard YG101 SWING GATE OPENER OWNER S MANUAL IMPORTANT SAFTEY INFORMATION Installing the YG101 Gate Opener requires wiring of standard 110V electrical lines This should only be performed by a trained technician Mis wiring could cause personal injury or DEATH To prevent the risk of electrocution be sure to turn off all power to the YG101 until installation is complete e The YG101 model gate opener is for a double sided gate The length of each section of the gate can be no greater than 6 5 feet for this opener to operate properly Do not attempt to use this gate opener with a gate length greater than 6 5 feet 2 meters e The maximum force that the gate opener can provide is 1500N e An electric lock is provided for installation for gate lengths greater than 5 feet 1 5 meters e In the event of power failure an emergency release key allows you to operate the gate manually for gate lengths greater than 5 feet 1 5 meters itis recommended that you unlock the electric lock e The gate can be opened or closed in manual mode ADDITIONAL FEATURES e An interface for an optional keypad is available on the control board e User may add additional remote controllers to operate the gate opener e This gate opener includes emergency stop and reverse functions if it senses an obstruction This feature MUST be tun
3. ate section NOTE Each section is completed separately See Fig 3 If the maximum angle for installing is 105 the retainer should be installed on the ground at approx 100 If the installing angle is 90 the retainer should be installed at 90 See Fig 3 Electric Lock If the gate section is gt 5 feet 1 5 meters it is recommended that you install the electric lock Weld the steel plate of the lock to the gate and then fix the lock See Fig 9 to determine height of the plate Fig 9 Release here To install the base plate of the lock fix the plate to the ground with 3 screws and make sure that the lockpin can fit tightly in the hole in the plate Adjustment The pair of gate sections will not start simultaneously The gate section without the lock will start earlier than the other gate section so that both sections can be locked properly Maintenance and Electrical e Check the screw lubricant and add 1 grease regularly e Keep opener clean at all times e The XF24B control box is designed for the YG101 Swing Gate Opener Its main technical parameters are as follow 0000000 Power Supply AC 110V Environmental Temperature 14 F 104 F 10 C 40 C Motor AC 110V max power 735W Electronic Lock DC 12V 2A Operating Time 20 seconds 100 seconds Relay Coil Voltage DC 12V SCM power supply DC 5V Weight of Control Box 4 4 lbs 2Kg e Main Function Radio control the re
4. ce BV IC LD 5V K G T Table 4 Connection between control board and operator No 1 motor COM U No 1 motor V WI No 1 motor W U2 No 2 motor COM U No 2 motor V We No 2 motor W Gatekeeper Ltd PO Box 752 Laceys Spring AL 35754 info gatekeeperltd com 2005 2007 GatekeeperLtd All Rights Reserved
5. ceiver can receive hopping code frequency 433 92MHz The gate will auto reverse when it contacts obstruction Auto close function can be selected to close the gate automatically after delay time It can control single gate or dual gate e Safety Instructions The gate opener s hould be installed by a qualified technician otherwise serious personal injury or property damage may occur Before installation all the locks of thegate should be removed or unlocked The auto reverse function must be checked during installation to ensure that the gate can auto reverse in the event of obstruction This auto reverse function should be regularly inspected and adjusted if necessary When opening or closing the gate DO NOT attempt to walk or drive through the gate DO NOT touch the gate while it is in operation The opener should be switched off before repairing it or opening its cover o Please erase and reset the code after installing the opener e Installation o Remove the cover of the control box remove the control board and fix the control box on the wall perform the wiring and cover again Connect L to power line N to neutral and E toearth wire e Adjustment of the Auto Reverse Function Tuning the auto reverse safety function Rotate the Force Adj Knob with a screwdriver The resistance may be increased or decreased by rotating clockwise or counterclockwise If the gate can be removed
6. ed prior to operation Be sure to follow the directions in the section on Tuning the Auto Reverse prior to operational use Specifications Power Supply AC 110V 10 V 60Hz Motor Speed 1680 rpm Motor Output 100W Opening Time lt 26 seconds Working Angle of Gate 90 or 105 Max Gate Section Weight Max Gate Section Width Duty Cycle Noise Parts List CE foer Central gear Waterproof seal Pin 4x20 Hexagonal nut Seal 13 2x2 65 En Light housing Square gasket EN Waterproof seal se DL Parts Diagram Installation Main Structure Fig 1 Fig 2 Gate pillar Gate opener One of the first decisions that should be made is if this installation is a push to open or a pull to open In either configuration the gate is mounted on one face of the mounting post and the opener is mounted on face 90 degrees from it Below are schematics of both push to open and pull to open configurations Push fo Open Closed Enlarge 7771 11111 TA AME EE Retainer lose position y N IEEE ETt TT ANS Retainer open position When the opener is installed the installation angle should be gt 0 See Fig 3 The baseboard should be fixed to the pillar of the building See Fig 3 Enlarge Fig 3 Retainer close position TZ a B Crax A 140 125 50 90 2 130 115 50 105 ata Enlarge R
7. etainer open position F ront and Rear Parts of Gate Opener To install the rear part of the gate opener insert shoulder screw and spacer then tighten with the nut See Fig 4 Fig 4 Shoulder screw Rear part of e li gate opener Support bracket Spacer S Nut To install the front part fit the hole in the front part with the hole in the supporting plate and push the axle pin into the holes using hands or a hammer and finally fit the retainer clip See Fig 5 Fig 5 Supporting plate Axle pin Front part of gate opener se clip Wiring Screw off the two stainless tapping screws then remove the cover and wiring as shown in Fig 6 WARNING Follow the wiring diagram precisely Failure to do so could cause damage to the gate opener controller Fig 6 a Stainless tapping screw Upper cover Enlarge Hood Shield Install the hood pipe tighten the screws into the opener and cover the hood shield over the joint See Fig 7 Fig 7 Main unit Hood pipe Scew Ces Hood shield N Waterproof caps There are 8 caps in total 4 to be used and 4 spares When the gate opener is installed the caps are used to cover the upper holes of the unit to avoid leakage See Fig 8 Fig 8 gii re cap Gate opener Retainer Closed and Opened Positions Close the gate section to its fully closed position fix the retainer according to the position of the g
8. gt Mi oes as ut coco oe Liu Serer a el 4 col 5 wy Le ue EF er ss ma ees DE C2 ELS fate betis ky i oie cite eee aT eee e em eee eee a x ATID Es wcll tre ra 21 20NS U8U7 6 US 14 13 Table1 Wring Notes of Control Board 2 Transformer input AC110V The resistance may be increased or decreased by rotating clockwise or anticlockwise Adjusting knob for No 1 gate which has electrical lock 6 Antenna Impedance 500 7 Power indicator light 1206 8 Indicator light 1206 9 Learn button 66 3 Capacitance interface of No 2 Suitable for No 2 motor motor No 2 motor interface See table 4 Capacitance interface of No 1 motor Suitable for No 1 motor It will ring if the gate is jammed The resistance may be increased or 5 Adjusting knob for No 2 gate decreased by rotating clockwise or anticlockwise Table2 Mode S witch Dual gate 2 Single gate for No 1 gate Dual gate first open last close Dual gate two gates open or close at the same time 4 Enables auto close 5 For swing gate Working time is 60s Working time is 90s 7 Single button OL NOTE Be sure the factory preset of bit 3 and bit 5 of the mode switch is ON please DO NOT adjust it Table 3 Wiring terminal for external button external device Tag Remark Output 12V 100mA Infrared N C GC External button Close TC Externalbutton Stop LD Loop detectorinterfa

Download Pdf Manuals

image

Related Search

Related Contents

1632 MORT PAR LE PRÛTOXYDE D`AZOTE.  BECKRYLAC DT6/SC BLANC GAMC 3665 M1341 Code  説明書兼レシピダウンロード  Mini-3GHD User Manual .pmd - Broadata Communications, Inc.  LEAPER-2 Handy Linear IC Tester User Manual  GE 00015922 Cordless Telephone User Manual    MODEL # ZX-8680  Product Manual - TelecomTest Solutions  Spirit industrial wmi 220  