Home

Manual SBX-3

image

Contents

1. ym oy BR AIW WwW Wl WI NIN NM Learn Remote Controller The remote controller supplied with the unit is learned to the main unit in fac tory The following procedure is only necessary if a new remote controller is to be used with the system In order for SBX 3 to recognize the commands from a remote controller it has to be learned The procedure for learning the remote is 1 Press the learning button on the left hand side of SIM card holder for 2 sec 2 sek 2 The Learning LED will light for 7 seconds During these 7 seconds 4 press any key on remote To learn another remote press any key on that remote also within the 7 seconds or repeatthe learning proce dure later 3 If you want to clear all learning on the SBX 3 simply press the lear ning button until the learning LED begins to flash T redKnows 17 TECHNICAL SPECIFICATION System description redKnows SBX 3 is a very compact security and tracking system Using highly sensitive GPS modules and tri band GSM modules the mini security tracker can perform security and tracking for all over the world The water resistant design allows the SBX 3 to be applied to any mobile vehicle boats houses cargo containers and any objects for complete safety Functions GPS positioning and GSM communication Temporary or continuous reporting with select
2. SMS message SOS Alarm When SOS button is pressed twice in less than 3 Mode seconds the SOS alarm is triggered Alarm TRG SOS GMT 090912 Long 011 57 177E When SOS is triggered the mobile phones s Lat 57 44 8876N in group 2 will receive an SOS status message Speed 001knots Hdg 348 Battery ok OUT_OFF v1 60 Immobiliser Heater Refrigerator Water pump Relay control An external relay can be switched on or off by SMS The phone numbers in group 6 can be used for this function When used for immobilizing the vehicle the engine can not be started if the relay control function is on One way to achieve this is to break the battery cable to the ignition key and connect to the NC Normal Closed terminals of the relay WARNING This type of installation should only be made by a person with proper knowledge of the elec trical system of the vehicle Be aware that turning off the engine can be dangerous for a vehicle in motion or a boat at sea so use this function with care If immobilization function is not required this function can be used to turn on and off other devices such as a refrigerator a heater or water pump The relay is switched on when SBX 3 receives SMS message OUT_ON The relay is switched off when SBX 3 receives SMS message OUT_OFF or when SBX 3 is disarmed Attention Use only UPPERCASE letters in your SMS U redKnows 7 Monitoring Function When SBX 3 receives a phone call from
3. 6 due to the fact that even if the vehicle is in a fixed position the data from the GPS can change depending on high buildings etc that can reflect signals from GPS satellites so that the position changes If a false alarm is triggered as a result the values for LAT and LON should be increased When armed the SBX 3 will store the current position Then every ten minutes it will exit power saving mode read the GPS position and compare with the stored position If either the LAT or LON difference exceeds the specified values the Geofence alarm is triggered When the alarm is triggered the mobile phones in group 1 will receive a LOCATE status message Low battery Alarm When the SBX 3 voltage goes below 9V for more than 40 seconds the alarm is triggered When the alarm is triggered the mobile phones in group 1 will receive a BATTERY_OFF status message The status information will then show the text Battery NG no good 6 T redKnows SMS message redKnows Mode Speed 001knots Hdg 348 Battery ok OUT_OFF v1 60 Disconnected GPS Alarm SMS message When the GPS data is missing this alarm is triggered If the GPS cable is disconnected or cut off it will trigger the alarm redKnows Mode Alarm TRG BATTERY a OFF GMT 090912 When the alarm is triggered the mobile phones in group 1 will Long 011 57 177E receive a GPS NG status message ee aes Speed 001knots Hdg 348 Battery NG OUT_OFF v1 60
4. Location Search by phone call SMS meddelande Lat 57 44 8876N 2 Speed 001knots Hdg 348 Battery ok When users in group 5 call to SBX 3 the system will send back one OUT_OFF v1 60 SMS with Alarm status and position Example When users in group 5 call SBX 3 the unit will not answer the call which results in a busy tone or an error message from the operator This is to avoid unnecessary cost for the caller SBX 3 then sends an SMS to the user On www redknows com under Locate there is a function for entering the coordinates and get a map with the position indicated Changing telephone numbers using SMS Attention use only UPPERCASE letters in your SMS Users can change the setting in the phonebook by sending SMS to the SBX 3 Any number or setting in the phonebook can be changed or added by an SMS in this format TSST aa bb amp aa phonebook name bb phone number Several numbers can be sent in one SMS separated by amp Remember to finish the message with amp Example 1 Message TSSTSUSER_A 0706123456 amp SEARCH_A 06123456 amp it will set USER_A to 0706123456 and SEARCH _A to 06123456 which are the last 8 digits of the USER_A number Example 2 Message TSSTSLAT 8 amp LON 8 amp will change the Geofence region to LAT 8 and LON 8 Power saving mode SBX 3 has an automatic power saving function When it enters the power saving mode all LEDs are shut off and the GPS is powered down
5. To exit the power saving mode press the unlock key on the remote control U redKnows INSTALLATION MANUAL System parts included e Main unit with integrated GSM module and spare battery e GPS receiver e GSM antenna e Siren e Remote Control e Microphone e Cable kit e Magnet Switch NOTE Only in the Marine package Not included SIM card for SBX 3 more information in the Setup Manual section 1 White Antenna for remote control 2 Orange Connections Input and output wires Colour Cable inen Function U EEEE E ee 1 ren Microphgne c U 2 F wn UO j Relay option LEJE O d Q D N Not activated 4 Green PONS ort rete cae 3 Relay control Siren G nie ue 4 it High decibel siren RULES 7 Brown White ns 5 Not activated BSS aa A 6 Door trigger option aa NO Positive activation Door trigger Positive triggering SE EEEE 7 SL Sensor input A vibration sensor can Purple 8 be connected option NO Negative RE ec Activation d impulses within 6 secto Sensor trigger Negative triggering trigger alarm Gray snianennsne ower aannGan 9 WO specifications Sensor trigger Positive triggering Main battery 12 V i Sensor2 input The magnetic ROU eaaa 10 ZAV OT PONS ON contact can be connected Input 6 11 Max 30V NC Positive activation This input must be grounded if BONNE 11 Output 3 Max 300
6. mA not used ACC trigger Positive triggering Con BARS errr 12 i Ignition key input Positive Internal Spare battery Gnd connect to 7 10 Main battery U redKnows activation Cable Installation instructions Cable 1 RF antenna for receiving signal from remote key Install as vertical as possible in order to achieve maximum range Cable 2 Not active Cable 3 Relay control This output can be used to control a relay for an immobilizer or other equipment by sending SMS The relay is connected between battery and cable 3 Max current 300 mA Cable 4 High decibel siren included with SBX 3 is connected with red cable to battery 12V and black cable to cable 4 Cable 5 Not active Cable 6 Door trigger input Positive triggering gt 1 5V is positive lt 1 5V or no connection is negative An alarm sensor with Normal Open NO contact can be connected to cable 6 and battery Several sensors can be connected in parallel when one of them is activated the input is positive and the alarm is trig gered Cable 7 External main battery Gnd Connect as close to battery negative terminal as possible NOTE Do not connect cable 7 until the SIM card has been inserted into the SBX 3 Cable 8 Sensor trigger Negative triggering gt 1 5V or no connection is positive lt 1 5V is negative An alarm sensor with Normal Open NO contact can be connected to cable 8 and ground Several sensors can be connected in parallel when one of the
7. mobile phones in group 1 will receive a SENSOR status message The siren will beep for 45 seconds Pin 8 requires 3 ground impulses within 6 seconds to be triggered SE U redKnows SMS message redKnows Mode Alarm TRG ACC_ON GMT 090912 Long 011 57 177E Lat 57 44 8876N Speed 001knots Hdg 348 Battery ok OUT_OFF v1 60 SMS message redKnows Mode Alarm TRG DOOR_OPEN GMT 090912 Long 011 57 177E Lat 57 44 8876N Speed 001knots Hdg 348 Battery ok OUT_OFF v1 60 SMS message redKnows Mode Alarm TRG SENSOR1 GMT 090912 Long 011 57 177E Lat 57 44 8876N Speed 001knots Hdg 348 Battery ok OUT_OFF v1 60 Geofence Alarm FEN Geofence can be translated to geographical fence if the object is moved outside an area from the position where the alarm was armed the alarm will be triggered The user can define the size of the approved re gion between 0 10 to 0 90 minutes 0 10 minutes is equal to 185 metres in a north south direction latitude In a west east direction longitude the distance lessens depending on the latitude Latitude 57 equals 100 metres The approved region is defined on the SIM card as LON and LAT with the numbers 1 9 indicating one hundredth of a minute If the SIM card shows LON 3 LAT 3 the approved region is 0 30 minutes from the place where the object was triggered i e approx 300 resp 555 metres Recommended setting is
8. send SMS to control SBX 3 Shaded positions in the table on page 17 should not be changed or used As a basic setting we suggest the following In MAIN_A the telephone number of the SIM card The primary user s phone number in USER_A and the last 8 digits of the primary user s phone number in SEARCH_A The primary user can then receive alarms call in for status SMS and send an SMS to control the SBX 3 Preinstalled numbers Group SETUP 0112204305550451240 CYCLE 0000 MAIN_A 9999 CALL_A 9999 6 CALL_B 9999 6 CALL_C 9999 6 CALL_D 9999 6 CALL_E 9999 6 USER_O 9999 1 6 USER_A 9999 1 6 USER_B 9999 1 6 USER_C 9999 2 6 USER_D 9999 6 USER_E 9999 6 CSC_A 9999 3 ESCHE 9999 3 STEL_A 9999 3 STEL_B 9999 3 IN_A 9999 4 IN_B 9999 4 LON 6 LAT 6 SEARCH_A 9999 5 SEARCH_B 9999 SEARCH_C 9999 redKnows 1234567890 U redKnows 15 Sending an SMS to enter the numbers In order to store numbers and settings in the SBX 3 SIM card send an SMS in this format TSSTSMAIN_A 0733123456 amp USER_A 0706123456 amp SEARCH_A 06123456 amp Where 0733123456 should be changed to the telephone number of the SIM card 0706123456 should be changed to the primary user s phone number 06123456 should be changed to the last 8 digits of the primary user s telephone number When the SBX 3 has received the SMS the numbers are entered into the SIM card the yellow LED will go off while the other LEDs will be on or flashing for a couple of minute
9. SBX 3 Mini Tracker AxTech AB 2007 v 2 User and Installation Manual INTRODUCTION Thank you for your purchase of redKnows SBX 3 series product In order to take full advantage of this product please read this manual carefully before starting to use the product SBX 3 can be used for guarding many types of objects such as cars boats excavators containers motor cycles campervans and others In this manual all objects are referred to as vehicles or objects SBX 3 is a GSM based positioning alarm The alarm can be triggered by an alarm sensor connected to one of the inputs or if the object is moved outside a defined area so called geofencing When triggered the siren will sound and an SMS message will be sent to pre stored telephone numbers In addition to the alarm function SBX 3 can also be used for tracking the position of an object and control equipment with SMS The SBX 3 can only communicate with the pre stored telephone numbers on the SIM card in SBX 3 They can receive SMS alarms and control them In the package you will find Main unit with integrated GSM module and Siren spare battery Remote Control GPS receiver Microphone GSM antenna Cable kit Magnet Switch Marine package only The units are installed according to the instructions in this manual and a SIM card is inserted Then the user s telephone numbers has to be stored into the SIM card in order to allow access to the system After this int
10. able reporting time internals SOS Emergency button on the remote for help Anti theft alarms Remote audio monitoring of object with included microphone Water resistant and robust enclosure Automatic power saving mode Wide input power range DC 10V 30V Easy installation and hiding Tri band GSM module for worldwide tracking and monitoring Highly sensitive GPS module GPS GSM and systems operation status signal LED display Using SIM card phone book to set reporting numbers and parameters to make the interface easy Immobilization function possible Can connect to PC or PDA for navigation Can connect to traditional car motorcycle alarm system to add GSM reporting function Can connect to traditional home alarm system to add GSM reporting function Embedded 750 mA rechargeable battery Specifications Dimension 98mm x 72mm x32mm Weight 300g Power DC 10V 30V Power consumption Energy save mode 20 80mA max lt 600mA Inputs Max 30V Output Max 30V 300 mA GSM frequencies Tri band 900 1800 1900MHz Battery 750mAh rechargeable Li lon Temperature Operating 20 C 55 C storage 30 C 70 C 18 U redKnows Accessories optional Motion sensor Infrared 4 Vibration sensor Magnet Switch Glossary Explanations for some technical expressions appearing in the manual GPS Global Positioning System A global satellite system for positioning and na
11. and mobile phone there is no need to have easy access to the units Main unit Install with cabling down for splash proof protection GPS receiver Must be installed horizontally in a place where the GPS signals from several satellites can be received That means that the GPS antenna should be able to see most of the sky However the signals can travel through glass plastics and other soft materials if not too thick Metal roofing and even glass with an invisible metal coating will screen out the signal The red GPS LED on the unit will flash when a position is found this can take up to one hour the first time the GPS is used GSM antenna Install vertically and at least 50 cm from the main unit and GPS to avoid possible interfe rence In metal surroundings such as a steel boat check the signal strength with a mobile phone Siren Install indoors but if possible near a ventilation so that the sound can be well heard from outside In order to reduce the risk of intruders finding the system and disarming the alarm the siren should be pla ced as far from the main unit as possible with its cables hidden The sirens can alternatively be completely disconnected Ask you insurance company which alternative they recommend Microphone Install in any place where possible intruders could be monitored Magnet Switch included in the marine package Should be installed on the inside of a door or opening through which the intruder has to pass Wh
12. bowrabossasnsedancensavesseneniiees cheeremmeaeeaeveanneeninnss 9 Changing telephone numbers USING SMS ssssessssessssessssessssessssessssessssessssesssseessseessseossseessseessseessseessseessseessseessseessseessseess 9 Power SAMIR en ne 9 INSTALLATION M ANA a ne 10 Systemi parts NO ac a one 10 EINE O yc ne E rn E Cn AEE eee eer ere ene enero 10 Input and output WAV INS scarce a esses tag va cheese ravens aa nine co one 10 Cable instalation MSUN S unesme nan ea a 11 PG SE AIA 11e Misean a E E S E E EE E E 12 ETURMAN UPE a AA E O E A A eee 13 SIM card in users mobile phoOne seessssessesssessseesssessecsseeesecesscosseossesseeesscenscooseesseesssesstesseooseesssessscosecoseeesetosscosstoseeesetrsstorseessees 13 SIM card IN SBX 3 ne a aan do ee E E E E EE a 14 Programming the SIM card IS BR amenant aniomnenun 14 Learn Remota Controllo coi dd bn nn a Gone 17 TECHNICAL SPECICATION ed 18 SCO A AA S exten A AONE NOA AEA T 18 ER E E E NE E AE E A E 18 Specifications ksr ena nasa AEEA KEEA EE AEE BAEAN aie eres ete 18 Accessories Optional seesssesssesseeesscessesssessseesseesssessecsseeenecosscosseosecesscesscosstosseeseresscesstosscesserssseosteosteoseesseeosstoseeoseresseossessscoseeess 19 MS N y e E E E E E E E 19 2 U redKnows USER MANUAL The functions of SBX 3 are controlled by the wireless Remote Controller and a mobile phone through SMS and phone calls With the remote controller you can e Arm and disarm SBX 3 e Send a
13. der Programming the SIM card SIM card in users mobile phone The SBX 3 must identify incoming calls and SMS in order to authorise an action or response To do that it uses the Caller ID function Some types of SIM cards such as an extra card to a subscription do not provide the Caller ID function and can not be used to call the SBX 3 it can only send SMS U redKnows 13 SIM card in SBX 3 When selecting operator and type of SIM card carefully consider the following factors Use a SIM card from the same country as the user s SIM cards even if the object is in another country Pre paid or subscription Pre paid cards normally must be filled with credit once a year or they will expire They should have the possibility to check the remaining credit on the operators website and to fill with new credit on Internet sites If a prepaid SIM card has been inactive no calls or SMS for 6 months an operator i e Vodafone can choose to deactivate the SIM card With that type of card be sure to use it at least once every 6 months Caller ID function Verify that the number of incoming calls is displayed when the SIM card is used in a mobile phone Some operators require that prepaid SIM cards are registered in order to activate the Caller ID function Coverage The GSM coverage can vary between different operators Check for coverage in the area where your SBX 3 normally will be located Call and SMS charges Not as important since the
14. en the door is closed the distance between the magnet and the switch must not exceed 10 mm Other sensors Depending on type of object and desired protection a number of different sensors can be applied There are several types and models of motion sensors on the market as well as water level sensors mats smoke alarms gas sensors etc that can be connected to the SBX 3 inputs 12 U redKnows SETUP MANUAL Remote learning button Learning process LED Under the top lid of the main unit there are four LEDs a slot for the SIM card and a button for pairing a new remote controller to the main unit SBX 3 has an automatic power saving function When it enters the power saving mode all LEDs are off and the GPS is powered down To exit the power saving mode press the unlock key on the remote control The red GPS LED is on when the GPS is connected to the unit but no position can be found The red GPS LED flashes when a position is found It normally takes a minute or so after power on until position is found but the first time the GPS is used it can take up to one hour Yellow GSM LED flashes when the SBX 3 is in contact with the GSM net Green SYS LED flashes when the SBX 3 is in operation During power up the LEDs indicate one or both of the following functions GPS LED GSM LED SYS LED Function On Off Flashing SIM card is read Flashing Off On SIM card is initialized with basic settings More information un
15. icture SMS message redKnows Mode Lat 57 44 8876N Speed 001knots Hdg 348 Battery ok OUT_OFF v1 60 Mobile Phone With the mobile phone you can besides receiving alarm messages also track the position of an object and control equipment by sending an SMS The SBX 3 can only communicate with the pre stored telephone numbers on the SIM card in SBX 3 They can receive SMS alarms and control them A table in section 3 Setup Manual shows the content of the SIM card here is a short summary Group 1 receives all SMS alarms except SOS Group 2 receives SOS alarms SMS Group 4 can call and listen to sounds from the microphone Group 5 can call to receive status SMS Group 6 can send control SMS with commands to SBX 3 The picture shows an SMS where the alarm has been triggered by alarm input 2 being activated by e g a magnetic contact on a door Alarm TRG SENSOR 2 shows that the alarm has been triggered by a sensor connected to the SENSOR2 input GMT shows the time for the alarm in Greenwich Mean Time Lat and Long show the position from the GPS receiver Speed and Hdg show the speed and heading of the object This information also comes from the GPS Battery ok shows that the battery providing power to the alarm usually the standard boat or car battery has a voltage above 9V OUT_OFF shows that the relay control output is off v1 60 is a version number which can vary depending on the manufac
16. m is activated the input is grounded Sensor 1 trigger requires 3 ground impulses within 6 seconds in order to trigger the alarm Cable 9 Sensor2 trigger Positive triggering gt 1 5V or no connection is pos lt 1 5V is neg To this input sensors with Normal Closed contact should be connected The sensors should be connected between pin 9 and ground Several sensors can be connected in series if any one of them is activated the alarm will be triggered NOTE Connect cable 9 to ground if not used otherwise the alarm can not be armed Cable 10 External main battery Connect and fuse as close to battery positive terminal as possible Be sure to connect between the battery and the main switch in order to provide power to SBX 3 when the main switch is off Cable 11 Ignition ACC trigger Positive triggering Connect to ignition key output or a fuse terminal with battery voltage when the ignition key is turned on Cable 12 Internal Spare battery Gnd connect to External main battery Gnd cable 7 This cable is recogni sed on delivery by being shorter than the other cables NOTE Do not connect cable 12 until the SIM card has been inserted into the SBX 3 U redKnows 11 Installation For best protection the system should be installed in a way that makes it very difficult for an intruder to discover and manipulate it Hide the components and cabling as much as possible Since SBX 3 is opera ted only with the wireless Remote Controller
17. n S O S message to one or more mobile phones With a mobile phone you can e Send SMS to arm and disarm SBX 3 e Send SMS to receive position from the alarm e Send SMS to control equipment like a heater e Send SMS to change telephone numbers in SBX 3 e Call SBX 3 to receive status and position from SBX 3 e Call SBX 3 to listen to the microphone e Receive alarm SMS from SBX 3 T button Lock button Remote Controller Unlock button The remote controller has four buttons The T button is only used for initiating the SIM card see the setup instructions The functions of the other buttons are described here A red LED under the SOS button flashes when a button is pressed SOS button The remote controller is powered with a long life 12V battery measuring 10x28 mm Arm and disarm using the Remote Controller The alarm is armed with the Lock button and disarmed with the Unlock button When the alarm is armed the high decibel siren will beep once amp If a sensor input is in an activated state the SBX 3 will not go into armed mode and the high decibel siren will beep 3 times as a warning When disarming the high decibel siren will beep twice If the relay is on it will be switched off SOS Trigger When the SOS button is pressed twice within 3 seconds the SOS alarm is triggered When SOS alarm is triggered the mobile phones in group 2 will receive an SMS message with the text SOS as well as time position etc see p
18. phone numbers in group 4 the system will automatically answer the call and the caller can hear the sounds picked up by the connected microphone NOTE If the unit is roaming to an operator in another country a pre paid SIM card could run out off credit very fast due to the fact that the cost for the foreign part of the call is paid by the receiver This can occur also near country borders depending on the signal strength from the different operator s base stations Location Search by SMS When SBX 3 receives a TRACK message the system will send back an SMS with LOCATE status The phone numbers in group 6 can be used for this function The format of the message is TRACKssnn ss is the number of 10 second intervals between LOCATE SMS The interval can be set between 10 to 990 seconds ss 01 is 10 seconds and ss 99 is 990 seconds nn is the number of LOCATE SMS to be sent from SBX 3 The number can be set between 01 to 99 The default number is 5 SMS message TRACK6O is the same as TRACK6005 it will send back 5 SMS with LOCATE status to the user in 600 second intervals The SMS message TRACKO001 will send back one SMS with LOCATE status The SMS message TRACKO000 will cancel the location search function the remaining SMS will not be sent 8 T redKnows SMS message redKnows Mode LOCATE GMT 090912 Long 011 57 177E Lat 57 44 8876N Speed 001knots Hdg 348 Battery ok OUT_ OFF v1 60
19. re are normally very few SMS sent from SBX 3 and no calls Call and SMS from abroad Important if there is a possibility that the object will be taken to another country Check with operators that SMS can be sent from another country in the same way as within the own country Verify that number presentation will work to and from another country if you want to contact SBX 3 when you are in another country Programming the SIM card in SBX 3 a The PIN code lock must be inactive use a mobile phone to verify Automatic answering function should also be inactive Insert the SIM card into the SIM card holder observing the correct position indicated by the figure close to the card slot The cut corner should be directed away from the three LEDs Apply power to the SBX 3 Connect the black cables 7 and 12 to ground and red cable 10 to battery On the remote controller press the T button four times and then the SOS button the yellow LED will go off while the other LEDs will be on or blinking for a couple of minutes When both the yellow GSM and green SYS light is blinking the SIM card is initialized with a SETUP code and phone book entries see the example on the next page Oy os Wait until the power up is complete and both the yellow GSM and green SYS il light are flashing Then the unit may enter the power saving mode all LEDs are off in that case press the unlock key on the remote controller to exit the power saving mode The user
20. roduction the manual continues with instructions for handling the SBX 3 with the remote controller and a mobile phone once it is installed and initialised The installation should be made by a person with proper knowledge of the electrical system of the object Instructions are found in the Installation Manual When the system is installed a SIM card is inserted and power is applied Then the SIM card should then be prepared with the proper settings these are descri bed in the Setup Manual U redKnows TABLE OF CONTENTS RER ODUCT N a a a a id ot nn no 1 SR Ne de ne a inde 3 PRS TOE OMEN ONG gcc coc so cee EAE Ai 3 Arm and disarm using the Remote Controller 3 OS TR nee tet E Oey ne ee ne R ero errr arn eae oe 3 Mobile PhONE E Rd a nd NN ci a nn ton dis 4 Useof SMS SAN ate and SA de on cn onda nome 4 a D eit auanrstistsease tay E 5 AE E EAN EE A T TAT i 5 PO MUI 2 AA A E E O E E A n 5 Sensor Alal aa a der non NO De no nl Ode 5 SOINS MAN a nd cn a round none 6 Low D aay EE ere A vee ene net ae Decne reece ett mee acter ener eneeey een rama een 6 Disconnected GP SFI cesses a a it on 7 BS AU NO A NE RO ER T cases ee A S 7 PRS VAG EE 19 10 ea tenes E eecpesvea soa ucsnen esa Pers E A E ANA 7 Monitoring gs UU EIRE pre FSM oR alee ne vg Saa TEN EC Eeee Tenet pe hetare ena 8 CEI ONY ANN DY SM3 a a a lodeatvec ones a Gn eaees samen 8 Location Search by phone call ssacscxssesnczocecavanccoecasdeeschd aaveasonensesasoscusnctsceseuthons cace
21. s When both the yellow GSM and green SYS light flash the SBX 3 is ready for use Using a mobile phone or SIM card reader to enter the numbers See the description for the mobile phone or SIM card reader We recommend the use of Internet or SMS to enter the numbers for the following reasons Some mobile phones can not enter numbers directly on the SIM card and may add a character to the name to indicate the type of number Some SIM card readers have problems reading certain types of SIM cards When reloading the SIM card into the main unit the unit has to perform a system reset in order to read the SIM card To do this disconnect wires 7 and 12 the two black ones and make sure that they have no contact with each other Wait a few seconds and reconnect both wires to ground When the GPS GMS and SYS LEDs flash after a few minutes the SBX 3 is ready for use Function test Call the SBX 3 using the primary user s mobile phone The SBX 3 will deny the call resulting in a busy tone or an error message from the operator An SMS with position and status information will arrive to the primary user s mobile phone usually within a minute 16 U redKnows SETUP Grp MAIN_A CALL_A CALL_B CALL_C CALL_D CALL_E USER_O USER_A WSEREB USER_C USER_D USER_E CSC_A CSC_B STEL_A STEL_B IN_A IN_B SEARCH_A SEARCH_B SEARCH_C LON LAT redKnows Example OV OV OV OV OV OV OV OV OV OV OV
22. s telephone numbers must now be stored on the SIM card This can be done in different ways e On the redknows com Internet site By sending an SMS to the SBX 3 e By removing the SIM card from SBX 3 and entering the numbers with a mobile phone or SIM card reader connected to a computer If you have access to Internet go to www redknows com and select SBX 3 EZ start The website is used to easily enter the phone numbers to be used with SBX 3 and select different options Then an SMS is created by the redknows com server and sent to SBX 3 making it ready to use 14 U redKnows If you do not use the Internet fill in the desired telephone numbers in the table on page 17 one number in each square Do NOT use country code at the beginning of phone numbers Note If Norwegian SIM cards are used special setup applies see separate information The SIM card s own telephone number is stored in the In MAIN_A Group 1 numbers receive all SMS alarms except SOS Group 2 numbers receive SOS SMS alarms Group 3 numbers are not used in this version Group 4 numbers can call in for monitoring Important Enter only the first six of the last eight digits of the phone number the unshaded positions in the chart above Group 5 numbers can call in for status SMS Important Enter only the last 8 digits of the phone number the unshaded positions in the chart above The same telephone number cannot be used in both group 4 and group 5 Group 6 numbers can
23. turing date The following describes which messages are sent to the mobile phone in different situations Use of SMS to arm and disarm The phone numbers in group 6 can be used for this function When SBX 3 receives SMS message SET it will arm the security system and the high decibel siren will beep once If a sensor input is in activated state the SBX 3 will not go into armed mode and the high decibel siren will beep 3 times as a warning To check at a distance if the alarm is activated mobiles in group 5 can phone for a SMS status which then shows Alarm ON If the message is CLR it will disarm the security system and the high decibel siren will beep twice If the relay is on it will be switched off Attention Use only UPPERCASE letters in your SMS 4 T redKnows Alarms Ignition ACC Alarm SBX 3 will immediately trigger the alarm when Ignition key ACC is turned on When the alarm is triggered the mobile phones in group 1 will receive ACC_ON status message The siren will beep for 45 seconds Door Alarm When someone opens a door with magnetic sensors the SBX 3 is triggered When the alarm is triggered the mobile phones in group 1 will receive a DOOR_OPEN status message The siren will beep for 45 seconds Sensor Alarm Input on pin 8 gives the message SENSOR1 and input on pin 9 gives the message SENSOR2 When a sensor is activated it will trigger the SBX 3 immediately When the alarm is triggered the
24. vigation GSM Global System for Mobile communication Telephone system for mobile phones LED Light emitting diode A small low current lamp LAT LONG Latitude and Longitude A coordinate system of degrees minutes and seconds covering the entire world Latitude 0 is the equator 90 N is the North Pole and 90 S is the South Pole Longitude 0 is the Greenwich Meridian or Prime Meridian GMT Greenwich Mean Time GMT is sometimes called Greenwich Meridian Time because it is measured from the Greenwich Meridian Line at the Royal Observatory in Greenwich London England It is the place from where all time zones are measured Sweden has GMT 1 hour 2 hours in the summertime SMS Short Message Service A text messaging service in the mobile telephone system Relay An electrically controlled circuit breaker SIM card A small plastic card with a computer chip used by mobile phones and SBX 3 The card contains information such as telephone number and mobile phone operator U redKnows 19 EC redKnows 60 TA LO0Z AV U281XY

Download Pdf Manuals

image

Related Search

Related Contents

Installaton manual ETP Comfort medium  LED LCD TV (CINEMA 3D TV)  User`s Manual  7ª SÉRIE - Diretoria de Ensino  - Polaris Brasil  Pince Type K 120/120/100    Higro-Termómetro Digital Registrador de datos EasyView  Installation Manual for CF Card Special Adapter FX3U-CF-ADP  

Copyright © All rights reserved.
Failed to retrieve file