10/100/1000BaseT to Mini-GBIC Industrial Media
Contents
1. 10 100 1000BaseT to Mini GBIC Industrial Media Converter User Manual antaira www antaira com Content Qi 1 1 3 4 Safety 4 Hardware 5 BONG Paliel acer ede quete om re D ELEC eid 5 Top VION E ci eon ch uie es 6 Wiring the Power 2 2 2 6 Wiring the Fault Alarm Contact 7 LEB Inaiealors 8 SS WIC altius d 9 10 cata ER ENS 11 Mounting Installation 15 DIN Rall MOUNTING 5 uo 15 Wall Mount Plate Mounting 17 Hardware Installation Installation Steps atu pde penus dolre tete bo bx NN Troubles 0 Technical Specification FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant
2. Table 2 2 Industrial Switch Converter DIP Switch Definition S W No Status Description j ON Enable Power Alarm OFF Disable Power Alarm ON Enables LLF OFF Disables LLF Link Lost Forwarding DIP Switch 2 When LLF is enabled it allows UTP link failures to be reported to the fiber side and also allows Fiber link failures to be reported to the UTP side Therefore a link loss forwarding feature is provided in both UTP and Fiber side When SW 2 is on once the fiber or UTP STP cable is disconnected the LNK ACT LED off When the cable is reconnected the LNK ACT LED blinks for 2 6 seconds which means the connection is recovering from failure Please don t change the DIP switch setting when UTP STP or fiber port is transmitting or receiving data It may cause some data error Besides if you change the DIP switch setting please power off the converter and power on again to make the setting effective Ports RJ 45 ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T 100Base TX or 1000Base T devices connections Auto MDI MDIX means that you can connect to another switch or workstation without changing straight through or crossover cabling See figures as below for straight through and crossover cable schematic RJ 45 Pin Assignments Note Pin Number Assignment 1 TX 2 3 6 Rx and signs represent the polarity of
3. 1 Usethe screws to screw on the DIN Rail on the industrial switch 2 Toremove the DIN Rail reverse the step 1 3 First insert the top of DIN Rail into the track 4 Then lightly push the button of DIN Rail into the track 5 Check the DIN Rail is tightly on the track 6 To remove the industrial switch from the track reverse steps above Wall Mount Plate Mounting Follow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail Place the wall mount plate on the rear panel of the industrial switch Use the screws to screw the wall mount plate on the industrial switch Use the hook holes at the corners of the wall mount plate to hang the industrial switch on the wall To remove the wall mount plate reverse steps above Hardware Installation In this paragraph we will describe how to install the 5 port 10 100 1000Base TX Industrial Switch Converter and the installation points for the attention 10 100 1000TX Ethernet Cat 5e above UTP STP cable Data collect server Human Management Interface Enterprise Switch Industrial Industrial Industrial Switch Switch Switch Converter Converter Converter Field Manag 10 100 1000TX Ethernet Cat 5e above UTP STP cable Programmable logic controlle Distribute VO control system Device Server l
4. 22 Free Fall Shock Vibration 23 CE EN61000 4 6 CS CE EN61000 4 8 CE EN61000 4 11 CE EN61000 4 12 CE EN61000 6 2 CE EN61000 6 4 IEC60068 2 32 IEC60068 2 27 IEC60068 2 6
5. the wires that make each wire pair All ports on this industrial switch converter support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX 1000Base T MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus RD Transmit Data plus TD 2 Receive Data minus RD Transmit Data minus TD 3 Transmit Data plus TD Receive Data plus RD 6 Transmit Data minus TD Receive Data minus RD Switch Router or PC 3 TD 3 RD 6 TD gt 6 RD RD 4 1 TD 2 RD 4 2 TD Straight Through Cable Schematic Switch Switch 3 TD 3 TD 6 TD 6 TD RD RD 2 RD 2 RD Cross Over Cable Schematic Cabling Twisted pair segment can use unshielded twisted pair UTP or shielded twisted pair STP cabling The cable between the link partner switch hub workstation etc and the converter must be less than 100 meters 328 ft long and comply with the IEEE 802 3ab 1000Base T standard for Category 5e or above Fiber segment using single mode connector type must use 9 125um single mode fiber cable You can connec
6. to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures or relocate the receiving antenna B Increase the separation between the equipment and receiver B Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Overview Introduction The 10 100 1000TX to MINI GBIC is designed to convert Gigabit Ethernet networks to Gigabit fiber networks by transparently converting Ethernet signals to optic signals The advantages of fiber optics are wide bandwidth EMI immunity and long distance transmission capabilit
7. Field Automatic device Field Automatic device Field Automatic Installation Steps 1 Unpacked the Industrial switch converter packing 2 Check the DIN Rail is screwed on the Industrial switch converter If the DIN Rail is not screwed on the Industrial switch converter Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial switch converter then please refer to Wall Mount Plate Mounting section for wall mount plate installation hang the Industrial switch converter the DIN Rail track or wall please refer to the Mounting Installation section 18 4 Power on the Industrial switch converter How to wire the power please refer to the Wiring the Power Inputs section The power LED on the Industrial switch converter will light up Please refer to the LED Indicators section for meaning of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of Category 5e or above cables into the Industrial switch converter Ethernet port RJ 45 port and another side of category 5e or above cables to the network devices Ethernet port RJ 45 port e g switch PC or Server The UTP port RJ 45 LED on the Industrial switch converter will light up when the cable connected with the network device Please refer to the LED Indicators section for LED light meaning Note Be sure the connected network devices su
8. is compact and can be mounted on a DIN rail or a panel so it is suitable for any space constrained environment Advanced Protection The power line of 10 100 1000TX to MINI GBIC Industrial Switch Converter supports up to 3 000 EFT protection which secure equipment against unregulated voltage and make systems safer and more reliable Meanwhile 6 000 Vpc ESD protections for Ethernet ports make the industrial switch converter more suitable for harsh environments Wide Operating Temperature The operating temperature of the 10 100 1000TX to MINI GBIC Industrial Switch Converter is between 40 75 C wide operating temperature model or 10 60 C standard model With such a wide range you can use the industrial switch converter in some of the harshest industrial environments that exist Easy Troubleshooting LED indicators make troubleshooting quick and easy The 10 100 1000 Base TX port has 2 LEDs that display the link status whether the port is working at 1000M transmission speed or not Also the three power indicators P1 P2 and Fault help you diagnose immediately Features Provides 1 x SFP mini GBIC type socket Provides 1 x 10 100 1000Mbps Ethernet ports with RJ 45 connector Supports full half duplex flow control Supports MDI MDI X auto crossover Supports surge EFT protection 3 000 Vpc for power line Supports 6 000 Vpc Ethernet ESD protection Embedded with a switch controller supports auto negotiation Support
9. pport MDI MDI X If it does not support then use the crossover category 5e above cable 7 When all connections are all set and LED lights all show in normal the installation is complete Troubles shooting W Verify that you are using the right power cord adapter DC 12 48V please don t use the power adapter with DC output higher than 48 or it will burn this switch converter down Select the proper UTP cable to construct your network Please check that you are using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 1000 Category 3 4 or 5 cable for 10Mbps connections 1000 Category 5 cable for 100Mbps or 100Q Category 5e above cable for 1000Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the industrial switch converter can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions W F the power indicator does not light on when the power cord is plugged in you may have a problem with power cord Then check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance f the Industrial switch converter LED indicators are normal and the connected cable
10. s it will detect the fault status which the power is failure or port link failure for managed model and form an open circuit Note The wire gauge for the terminal block should be in the range between 12 24 AWG If only using one power source jumper Pin 1 to Pin 5 and Pin 2 to Pin 6 to eliminate power fault alarm LED Indicators There are few LEDs display the power status and network status located on the front panel of the Industrial switch converter each of them has its own specific meaning as below table Table 2 1 Industrial Switch Converter LED Definition LED Color Description On Power input 1 is active 1 Green ois i Off Power input 1 is inactive On Power input 2 is active P2 Green P Off Power input 2 is inactive On Power input 1 or 2 has failed Fault Red Off Power input 1 and 2 are both functional or no power input On Connected to network LNK ACT ES Green Flashing Networking is active fiber port Off Not connected to network 1000 Link to 1000 bps network Yellow Not connected to network or not working RJ 45 Off at speed of 1000M LNK ACT On Connected to network Green Flashing Networking is active RJ 45 Off Not connected to network DIP Switch Note Note The DIP Switch is used to configure operation mode for LLF Link Lost Forwarding and power alarm The default value of DIP switch is OFF
11. s are correct and the packets still cannot transmit Please check your system s Ethernet devices configuration or status 20 Technical Specification The technical specifications of the Industrial Switch Converter are listed as follows Communications Standard LAN Transmission Distance Transmission Speed Interface Connectors LED Indicators Power Power Consumption Power Input Fault Output IEEE 802 3 802 3ab 802 3u 802 3x 802 3z 10 100 1000Base TX SFP mini GBIC Fiber Up to 110km Ethernet Up to 100 meters STP or UTP Up to 1000 Mbps Fiber 1 x SFP mini GBIC fiber socket 1 x RJ 45 6 pin removable screw terminal power amp relay TX port 1000M LNK ACT Fiber port LNK ACT P1 P2 Fault 5 28 W 2 x Unregulated 12 48 Vpc 1 Relay Output 21 Mechanism Dimensions WxDxH Enclosure Mounting Protection ESD Ethernet Surge EFT for power Reverse Polarity Overload Environment Operating Temperature Storage Temperature Operating Humidity Storage Humidity Certifications Safety EMC 30 x 95 x 140 mm IP30 Metal shell with solid mounting kits DIN rail wall 6 000 Vpc 3 000 Vpc Present 0 9A 12Vpc 25 C Standard model 10 60 C Wide temp model 40 75 C 40 85 C 5 95 non condensing 0 95 non condensing UL cUL CE EN 60950 1 FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge
12. s store amp forward transmission Supports redundant 12 48 Vpc power input Provides flexible mounting DIN rail Wall Mounting Supports operating temperatures from 40 75 C wide operating temperature model or 10 60 C standard model Packing List B 1x 10 100 1000 to Mini GBIC Industrial Switch Converter m 1x User manual m 2x Wall Mounting Bracket and Screws Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input Hardware Description In this paragraph we will introduce the Industrial switch converter s hardware spec port cabling information and wiring installation Front Panel The Front Panel of the 10 100 1000TX to MINI GBIC Industrial Switch Converter are shown as below Front Panel of the Industrial Switch Converter View top panel of the Industrial Switch Converter is equipped one terminal block connector of two DC power inputs Top panel of the Industrial Switch Converter Wiring the Power Inputs Please follow the steps below to insert the power wire V Vt V V 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector 2 To tighten the wire clamp screws for preventing the DC wires to loose Wiring the Fault Alarm Contact The fault alarm contact is in the middle of terminal block connector as the picture shows below Inserting the wire
13. t two devices in the distance of 10 km Fiber segment using multi mode connector type must use 50 125 or 62 5 125um multi mode fiber cable You can connect two devices up to 550m distances The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communication applications To connect the transceiver and LC cable please follow the steps shown below First insert the transceiver into the SFP module Notice that the triangle mark is the bottom of the module Triangle Mark f Figure 2 8 Transceiver to the SFP module Figure 2 9 Transceiver Inserted 12 Second insert the fiber cable of LC connector into the transceiver Figure 2 10 LC connector to the transceiver To remove the LC connector from the transceiver please follow the steps shown below First press the upper side of the LC connector from the transceiver and pull it out to release Figure 2 11 Remove LC connector 13 Second push down the metal loop and pull the transceiver out by the plastic part Figure 2 12 Pull out from the SFP module 14 Mounting Installation DIN Rail Mounting The DIN Rail is screwed on the industrial switch when out of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the below steps to hang the industrial switch Rear Side DIN Rail
14. y Therefore the industrial switch converter is an ideal solution for fiber to building applications at central offices or local sites The industrial switch converter supports MDI MDIX auto detection so you don t need to use crossover wires Furthermore the industrial switch converter can work normally from 10 60 and accepts a wide voltage range from 12 48 Besides it also provides 3 000 surge EFT protection against over voltage so it is suitable for harsh operating environments Gigabit Fiber Converter The 10 100 1000TX to MINI GBIC Industrial Switch Converter has one SFP fiber slot which provides the flexibility when planning and implementing a network The slot can accept any 1000M SFP type fiber module and these modules are designed for transmitting over distances of either 500m multi mode 10km 30km 50km 70km or 110km single mode This means you can easily change the transmission mode and distance of the switch by simply pulling out the SFP module and plugging in a different module The SFP module is hot swappable and plug and play Dual Power Input To reduce the risk of power failure the 10 100 1000TX to MINI GBIC Industrial Switch Converter provides 12 48 Vpc dual power inputs If there is power failure 10 100 1000TX to MINI GBIC Industrial Switch Converter will switch automatically to the secondary power input Flexible Mounting 10 100 1000TX to MINI GBIC Industrial Switch Converter