Home
CHAIR - ERU 2600CHAIR
Contents
1. Special warnings and or cautions about electrical hazards Verify if the outlet has grounding and was properly installed for optimal performance and safety as per ABNT Technical Standards When you complete the work it is essential that to turning off equipment using the ON OFF power switch before disconnecting the equipment from the AC This will prevent possible overload on the equipment next time you turn it on If there is lack of electricity or burning fuse disconnect the equipment through the switch thus avoiding return power to the equipment overcharging which may damage the equipment When replacing fuses maintain the same specifications type and capacity provided by the manufacturer to ensure electrical protection When replacing the fuse unplug equipment before using the power switch and unplug from the wall to prevent possible electric shock Do not use the power cord if any part of it is damaged 5 5 SPECIAL WARNINGS AND OR PRECAUTIONS DURING TRASNPORT AND STORAGE The equipment should be stored and transported with a high stack of two units and protected from moisture not exposed to rain spray etc Because it is a fragile product be careful to reduce the impact on the equipment 10 EZer 5 6 SPECIAL WARNINGS AND OR PRECAUTIONS FOR EQUIPMENT MAINTENANCE No repair or replace defective or inoperative equipment like parts of other appliances Only Eliezer and its distributors can make repairs with original pa
2. equipment must be connected to an outlet especially designed for this purpose and grounding as per Technical Standard ABNT to ensure total safety and proper operation Do not connect appliances or other equipment in the same outlet where the equipment is installed When the power cord is plugged into the power outlet ensure that no drilling in places where the extended movement of people to prevent accidental disconnection and possible damage to the cable outlet or power Level equipment using the leveling feet which are the base and in contact with the ground Adjust the stem headrest into the hole in the top of the back of the backrest and turn right onto the screw until it snaps into position Connect the footswtich on the side of the base of the seat optional If necessary the manufacturer has specialized technical team to install the equipment BEFORE INSTALLATION 4 SPECIAL STORAGE PRESERVATION AND OR HANDLING 4 1 PACKING All information on the precautions to be taken during transport and storage of the product are listed in the package itself through symbols normalized as follows SYMBOLOGY DESCRIPTION Fragile Caution in transport and storage Maximum stacking A maximum of two identical units can be stacked one atop another Need protection against moisture during transportation and storage Upwards Positioning of the containers during transport and storage Limit temperature 0 to 55 for transport
3. the most rigorous technical standards of quality to offer total security and user functionality If used according to instructions in this manual the computer does not cause any problems and not lose or change their physical dimensions and characteristics 7 INSTALLATION OR CONNECTION WITH OTHER PRODUCTS The Chair Ophthalmic ERU 200 no destination of compulsory direct connection to other equipment or products WARNING Use in conjunction with this team anywhere accessories or equipment other than those specified by the manufacturer is the sole responsibility of the user 11 EZer 8 SOLUTION OF PROBLEMS TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION On off in the Off Position Change the switch to the ON position The switch does not turn Utility breaker Reset circuit breaker only once Replace the fuse with one of the same specification ff switch ligh ON ZONE GERD Damaged or burned fuse board Contact the manufacturer command works No work movement incline and recline of the backrest Damaged or blown fuse Circuit fuse under the seat Contact the manufacturer damaged or burned The relay circuit jammed The seat does not move up and Contact the manufacturer down End of Course of the Elevation Tour is jammed Footswitch is not connected Connect footswitch Footswitch does not work Footswitch badly connected Remove and reconnect the footswitch Note If the problem is NOT resolved as descr
4. 0 cm x 1 28 cm x 75cm 2 7 COMPARISON TABLE BETWEEN THE MODEL ERU 2600 ACCION ERU 2600 Support arm vertical opening Seat up down Side Digital Command 3 Lateral digital footswitch 5 Footswitch 3 Footswitch 5 Tilt the backrest tilt Backing up or down Backup inclined chest tilt Horizontal swivel seat 180 2 90 2 90 2 Full Tilt Support arm vertical opening Spat tilt and recline BECO ES EHO U lt i a W Serie O Opcional X No es aplicable J er 2 8 DIRECTIONS FOR PROPER USE OF THE PRODUCT 2 8 1 OVERVIEW OF THE TEAM Front 2 8 2 POSITIONS USING THE CHAIR J Normal Position It is the position set for the entry of patient and initial exams Place the patient sitting ee Lying Position gt 2 It is the table position for minor procedures ge e Open and Close the Armrest Articulated Movement for ease of entry and leave of the patient rt A gt a A pi amp Chair Seat It has movement up and down controlled by the control panel or footswitch Chair Legrest Has reclining inclining movements simultaneously with backrest Headrest It has articulated motion with height adjustment and has injected foam upholstery 2 8 3 COMMANDS TO CONTROL THE MOVEMENT OF THE CHAIR The commands to control the Ophthalmic Chair ERU 200 can be activated by the operator through the footswtich or control panel It features electronic controls to adjust seat h
5. PRODUCT CHANGE OPERATION If the computer heating or strange noises make sure the problem is related to some of the problems mentioned in point 8 Troubleshooting If you still cannot solve the problem turn off the unit disconnect the power cord from the outlet and then contact an Eliezer Authorized Servicer for review and completion of the repairs 11 SENSITIVITY TO ENVIRONMENTAL CONDITIONS IN NORMAL USE SITUATIONS Ophthalmic Chair ERU 200 have been specially designed and developed to avoid sensitivity to electromagnetic interference external electrical influences electrostatic discharge and variations in pressure and temperature To do this the equipment must be transported installed handled and stored according to the instructions contained herein 12 PRECAUTIONS IN CASE OF DESTRUCTION OF THE PRODUCT In order to avoid environmental pollution or misuse of the product when it is useless segregation packaging identification and presentation at the risk of the client to company facilities Eliezer to carry out the elimination of the product safely 13
6. USER S MANUAL EJ er Product OPHTHALMIC CHAIR Model ERU 2600 CHAIR J er INTRODUCTION Congratulations You have just purchased a product developed using the latest concepts of high technology on the market This equipment has been designed following strict quality standards to provide maximum performance quality and safety to the user PRODUCT Technical Name Ophthalmologic Chair Trade Name ELIEZER Business Model ERU 2600 Chair BRAND ELIEZER WARNING Read all the information contained in this Manual before you begin using the Equipment ELI EZer CONTENTS 1 Presentation of models 2 Ophthalmologic Chair ERU 2600 2 1 Product Identification 2 2 Product Description 2 3 Physical principle and basis of product technology applied to its operation and its action 2 4 Parts and accessories accompanying the product 2 4 1 accessories 2 5 Optional items supplies and support materials 2 5 1 Optional elements 2 5 2 Consumables 2 5 3 Support materials 2 6 technical Specifications 2 7 Comparison table between the ERU 2600 models 2 8 Directions for proper use of the product 2 8 1 Overview of the equipment 2 8 2 Positions for the use of seat 2 8 3 The commands to control the movement of the seat 3 Installation of computer equipment 4 Special storage preservation and or handling 4 1 packaging 4 2 storage 4 3 transport 4 4 packaging 4 5 con
7. and storage 4 2 STORAGE Keep the product in its original packaging and in a place protected from moisture and heat If there is a need to store multiple equipment in its packaging with a high stack should be a maximum of two units as indicated by the symbol 4 3 TRANSPORTATION During transportation avoid vibration drops and impacts directly on the package When handling the equipment out of its original packaging take it from its base never by the arms or on other part of the equipment During transportation and storage to ensure that the environmental conditions within the specified ranges as described below Ambient temperature for storage and transport rrnnneeneennnenenennneneennnnennn nan nnenee enne 02C to 55 C Relative humidity for storage and transport ccccccccsssecccccsesssecccceeseccecseseecceseacceseueaeeeeseaaeeeeeseaaeeees 0 to 90 Atmospheric DTESSULE ii a iii i i ii iii i ii aai i 375 795 mmHg EZer AFTER INSTALLATION 4 4 PACKING Keep the product away from heat and humidity including from direct rays of the sun on the equipment During the transport and the operation of the product verify the environmental conditioning and within specified limits as describing as follows Ambient temperature for Transport and Storage nrvvneeneennnneneeennnnneneannnennen anne 102C to 352C Relative Humidity for storage and tranSport c
8. ccecccssscesssecssseecsssesesecesssecessaeesseeeceeeeseeaeaseeceeesssaaegeseeeeas 30 75 Atmospheric Pressure ssccscsssssccccssessccnssssscescessscescesssscestecsssscesesessceseesscescesesscseesesscseesssesscess 375 795 mmHg 4 5 CONSERVATION When in use clean equipment with a damp cloth and mild soap on upholstery and alcohol in the other parts After each use keep eguipment clean and disinfected Not to introduce or spill liguid inside the computer Do notuse solvents thinner or products that release chlorine to clean the eguipment Keep the equipment in a clean and dust free place 5 WARNINGS AND OR PRECAUTIONS TO BE TAKEN 5 1 SPECIAL WARNINGS AND OR PRECAUTIONS FOR USERS This equipment must be used only by trained personnel and under the direction of qualified medical personnel familiar with the known risks and benefits of the use of the ophthalmic chair 5 2 SPECIAL WARNINGS AND OR PRECAUTIONS WITH WEIGHT LIMITS Never exceed the weight limits specified by the manufacturer Do not sit on the Legrest or Backrest of the equipment Use only the seat for this purpose Danger of tipping 5 3 SPECIAL WARNINGS AND OR PRECAUTIONS ON HAZARDOUS Ophthalmic Chair ERU 2600 is not suitable for use in the presence of flammable anesthetics or other flammable gases such as some types of cleaning materials Do not connect and do not start the Ophthalmic Chair ERU 2600 in areas where there may be risk of explosion 5 4
9. e controlled by the operator by pedal or manual control It has a system to raise the seat backrest driven by an electric drive motor that works without oil and very quiet Its operation allows multiple configurations including children at full soeed and intermediate positions Its internal structure is made of SAE 1020 carbon steel with epoxy paint finish treatment and polystyrene surfaces for easy cleaning It has injected foam padding to combat distortion and layer controlled anti mold curvin density with rounded corners The equipment is provided at 110 220V with manual voltage selection 2 33 PHYSICAL PRINCIPLE AND BASIS OF PRODUCT TECHNOLOGY APPLIED TO ITS OPERATION AND ITS ACTION Equipment developed in painted steel frame with padding for support and is divided into two main parts seat and back with independent movements can be electrical motors with gears and pedals unit or manual levers and buttons EeZer 2 4 PARTES Y ACCESORIOS QUE ACOMPANAN EL PRODUCTO ITEM DESCRIPTION OS SHARES 01 Backrest 02 Seat 03 Legrest 04 Footrest 05 Aarmrest 06 Headrest 07 Headrest tilt adjustment screw 08 Headrest 09 Knob height adjustment headrest 10 Power Cable 11 Leveler Feet 12 Pedal connector optional 13 Base 14 Foot support 15 Horizontal safety knob optional 16 Holders 17 Voltage selection switch 18 Main switch ignition internal 19 Recliners Lock 2 4 1 ACCESSORIES Headrest Footsw
10. eight backrest and legrest simultaneously and back to the zero position wherein the seat returns to its normal position sitting to facilitate discharge of the patient The chair control operations are made by just a touch to the control PT WARNING The control panel and footswitch have no protection against liquid so cannot be considered waterproof Disposition of the commands in the Layout Panel Commands footswitch PEDAL GROUP COMMAND DESCRIPTION Lift the seat and the whole Drop seat and whole Recl Drop the backrest and at the same time lift Legrest Lift the backrest and at same time drop the Legrest Automatic Return to initial sitting position WARNING Expressly discourage the use of eguipment by untrained personnel and we take no responsibility for the incorrect use of this eguipment WARNING Read the instructions below before beginning installation of eguipment for the first time 3 INSTALLATION Before starting the installation of equipment make sure there is not a bad component inside the package If this happens immediately contact the company to resolve the problem Install the eguipment in the correct location with enough space so the movements can be made freely and allow access to all parts Verify there are either 127 V or 220 V power supply and that same supports at least 200 watts of power Note Your eguipment comes with manual voltage selector ELI EZer The
11. ibed in the table above please immediately contact the Eliezer Authorized Servicer 9 PROCEDURES FOR PRODUCT REUSE 9 1 CLEANING Cleaning of the equipment should be performed before and after each patient received Clean upholstery metal parts and the pedal optional with a damp cloth and mild soap Weakly alkaline cleaning can be used to clean upholstery Note Do not use any cleaner containing chlorine and or acid 9 2 DISINFECTION Location the usual toiletries plus a germicidal product or broad spectrum disinfectant being careful not to leave residues that may cause an allergic or toxic reaction in contact with the patient s body Alcohol based hand sanitizer can be purchased in the market with many different concentrations Note disinfectants can be used but the maximum values as shown below PRODUCT DILUTION MAXIMUM VALUES OF 100 G OF DISINFECTANT Etanol at 96 40g Propanol 35g Glut ric dialdeh dric at 25 0 075g Etiltexanal 0 010g Formaldehidric Solution 0 010g Glioxal 0 165g Sodium Hipocloritic 0 0508 Eliezer is NOT responsible for the use of different substances or solutions whose concentration is higher than specified in this manual 12 ELI EZer 9 3 PACKAGING Keep equipment away from moisture and heat If the equipment is out of service not used for a period of time it is advisable to disconnect the power cord from the wall outlet and reconnect only when used 10 PRECAUTIONS IN CASE OF
12. itch 2 5 OPTIONAL ITEMS SUPPLIES AND SUPPORT MATERIALS 2 5 1 OPTINAL ITEMS Footswitch Horizontal turning the Connector of the Footswitch locking knob ELI EJ er 2 5 2 Consumables Not applicable to products 2 5 3 SUPPORT MATERIALS Instructions and Warranty Attention The use of parts accessories or equipment not specified in the instruction is the responsibility of the owner and may even jeopardize the warranty period given by the product 2 6 TECHNICAL SPECIFICATIONS POC A ee ae ea E ee ee Class 1 low risk Protection against electric shock ccccccccssssccccceesecccceeeccccseeeesecceeaeeecesseaccessuaeccessuueecessansecessesaaaess Type B Class EYE Os IP POLS CTIOMN esse IPX4 protection against splashes ODE NE MO AM Continuous operation SUPPIY Voltage ee i 127 220V CIS eG QUEEN VE een ae ee eher 50 60 Hz LOS CU EN ee AA i E 2A VIG OM er 99 i 24V DC Fast Fuse Type Fuse ZO IN ee m teen 2A POWERCONSUND LION See ee ee E 150W EINE OAC ICY nennen A i A a a N 180Kg DIMENSIONS Garbage settings u nennen 2 00 cm x 70cm x 62cm Dimensions standard configuration cccccceeeeecccceesecceceesececceeeeeecsceeeusecesseeeeseeeees 1 00 cm x 1 41 cm x 70cm Fr ROWS SU NC 1S A ea ee ee een 780cm 56cm The occupied area t as table Nee EE 1 4 m NECN E aaa aaa ila a a a ak ia aa 78Kg GFOS WEIPNT ernennen Eee 105kg Type oi Dackel ee Ot een Wooden box Package dimensions essen 1 1
13. rts and to ensure the proper operation of the equipment To ensure the safety of electrical equipment throughout its life it is recommended that the unit checked by our qualified technician at regular intervals at least once a year Failure to periodic inspections may result in personal injury and damage to the chair 5 7 SPECIAL WARNINGS AND OR PRECAUTIONS IN CLEANING Ophthalmic Low chair and then disconnect from the network before any cleaning procedure Do not use the cleaning system or high pressure steam Do not use cleaning products that release chlorine or acid For heavily soiled surfaces use a mild soap in concentrated form and then wipe with a cloth dampened with clean water Do not use cleaning agents or wet chemical processes containing abrasives Keep free from oil and grease filling Keep equipment clean and disinfected after each medical procedure 6 PRODUCT PERFORMANCE 6 1 INDICATIONS AND INTENDED USE OF THE PRODUCT Note Designed for use in clinics and hospitals to help health professionals to position the patient in special positions for the diagnosis providing comfort to patients and professionals Purpose To facilitate positioning of patients for consultations and diagnostic and ophthalmic 6 2 UNDESIRABLE SIDE EFFECTS OR COLLATERAL Not applicable to this product 6 3 THE SAFETY AND EFFICACY OF THE PRODUCT The Chair Ophthalmic ERU 200 was designed and developed with non toxic materials and following
14. servation May Warnings and or precautions to be taken 5 1 Warnings and or precautions for users 5 2 Warnings and or precautions with weight limits 5 3 Warnings and or precautions about explosions 5 4 Warnings and or cautions about electrical hazards 5 5 Warnings and or precautions during transport and storage 5 6 Warnings and or precautions for equipment maintenance 5 7 Warnings and or precautions when cleaning 6 Product Performance 6 1 Indications and intended use of the product 6 2 Secondary or undesirable side effects 6 3 Security and efficacy of product 7 Installation or connection with other products 8 Troubleshooting 9 Procedures for product reuse 9 1 cleaning 9 2 disinfection 9 3 packaging 10 Precautions in case of product change operation 11 Sensitivity to environmental conditions under normal conditions of use 12 Precautions in case of destruction of the product J er 1 PRESENTATION OF MODELS Ophthalmologic Chair ERU 2600 is available in three different models to meet the diverse needs of medical professionals to meet your needs The following are all the information necessary to install and use the product 2 OPHTHALMOLOGIC CHAIR Ophthalmologic Chair ERU 2600 2 1 IDENTIFICATION PRODUCT Name Ophthalmologic Chair Trade name ELIEZER Business Model ERU 2600 Chair 2 2 PRODUCT DESCRIPTION The Ophthalmologic Chair ERU 2600 is a motorized chair can b
Download Pdf Manuals
Related Search
Related Contents
RCA CDP18S711 Cassette Player User Manual NOM-031-SCFI-1994 - Secretaría de Energía SET UP & USER MANUAL ISE70 215, avenue de l`Épée Outremont (Qc) H2V 3T3 SGY-PM910H 取扱説明書 - Pioneer cyclesports Copyright © All rights reserved.
Failed to retrieve file