Home
CCSCUControlUni_Data..
Contents
1. A card can be replaced by an empty card while recording is running When the full card is removed the recording is continued to a patent pending recording buffer When a new card is inserted into the CU the buffered recording is written onto the new card and the recording continues normally This gives seamless recording without the loss of any audio while an SD Card is exchanged Digital acoustic feedback suppression CCS CUD CCS CURD The digital acoustic feedback suppression facility automatically eliminates acoustic feedback also known as howling or Larson effect This gives better speech intelligibility by allowing the speaker volume to be turned up as loud as required without any risk of feedback Discussion control without operator The CU can be setup to operate standalone without the need for an operator The following 5 modes can be chosen using a rotary control on the unit s top panel e Open mode allows selection of one to four microphones excluded chairmen microphones which can be simultaneously active www boschsecurity com 2 CCS CU Control Unit e Open mode with auto switch off allows selection of one to four microphones excluded chairmen microphones which can be simultaneously active If the delegate does not speak for 30 seconds microphones are automatically switched off e Override mode delegates can override each other simply by activating their microphones Only one microphone ca
2. to an audience in the same room or an adjacent room e Tape recorder for external recording and playing back meetings and discussions e Audio equipment for providing background music e Telephone coupler to allow a remote delegate to participate via telephone e External audio processing an insertion connector is provided Controls and Indicators Top e Mains on off switch e Graphical display for status information CCS CUR CCS CURD e 5 soft buttons for configuration and control of the built in MP3 recorder CCS CUR CCS CURD e Loudspeaker volume control for setting output level of loudspeakers of contribution units This control also determines the maximum level for the headphone outputs of the contribution units and the CU e Microphone mode rotary switch for setting the number of simultaneously active microphones and selecting one of the four operation modes plus test mode e Power on LED Back e On off switch for digital acoustic feedback suppression facility CCS CUD CCS CURD e Microphone input gain adjustment e External recorder input gain adjustment e Insertion connector bypass switch Interconnections Top e 1x 3 5 mm 0 14 inch stereo headphone socket Back e 1xAC input e 2x 7 pole circular female connectors trunk in out loop through interconnection e 1x3 pole female XLR connector microphone input can be used as line input by included 50dB attenuator 1 x Cinch connector pair
3. 8h 37m 17h 14m 34h 28m 05h 44m 11h 29m 22h 58m 04h 18m O8h 37m 17h 14m Dimensions including feet 84x 361 x 143 mm 3 4 x 14 2 x 5 6 in HxWxD Height of feet Mounting Weight Material top Material base 5 5 mm 0 22 in tabletop portable or fixed 19 inch rack flush mounting 1 5 kg 3 3 Ib polymer painted metal Color top Color base black PH80007 Ordering Information CCS CU Control Unit supplies the power for all delegate and chair man units in the system plus the unit micro phones as well as providing connections for audio inputs and outputs CCS CUR Control Unit with Recorder With built in recorder to digitally record a dis cussion to an SD Card CCS CUD Control Unit with DAFS With digital acoustic feedback suppression fa cility CCS CURD Control Unit with Recorder and DAFS With built in recorder graphical display re cording buffer and acoustic feedback suppres sion facility CCS CU JP Control Unit JP Japanese version CCS CUR JP Control Unit with Recorder JP Japanese version CCS CUD JP Control Unit with DAFS JP Japanese version CCS CURD JP Control Unit with Recorder and DAFS JP Japanese version CCS CU US Control Unit US US version CCS CUR US Control Unit with Recorder US US version CCS CUD US Control Unit with DAFS US US version CCS CURD US Control Unit with Recorder and DAFS US US version charcoal PH10736 CCS CU CCS C
4. Communications Systems CCS CU Control Unit CCS CU Control Unit The Control Unit CU is the heart of the CCS 800 Ultro Discussion System and supplies the power for all delegate and chairman units in the system The unit also controls the chairman and delegate unit microphones as well as providing connections for audio inputs and outputs Functions Built in MP3 recording and playback with graphical display CCS CUR CCS CURD The CU has a built in recorder to digitally record a discussion to an SD Card The graphical display shows the status of the recorder and the accompanying buttons can be used to configure the recorder As an option the recording is only active when a microphone is active The SD card can be removed from the CU and processed on a PC for transcription purposes the recordings can also be retrieved by connecting a PC to the CU s USB The recordings can be played back to the monitor loudspeaker or to delegate s loudspeakers An audible beep and a flashing LED indicate when the SD Card is almost full and the user needs to replace it with a new card BOSCH Invented for life gt Built in MP3 recording and playback with graphical display gt Patent pending recording buffer gt Digital Acoustic Feedback Suppression gt Discussion control without operator gt Controls up to 150 contribution devices gt Built in monitor loudspeaker Patent pending recording buffer CCS CUR CCS CURD
5. UR CCS CUD CCS CURD CCS CU JP CCS CUR JP CCS CUD JP CCS CURD JP CCS CU US CCS CUR US CCS CUD US CCS CURD US www boschsecurity com CCS Americas Europe Middle East Africa Bosch Security Systems Inc Bosch Security Systems B V Communications Systems P O Box 80002 12000 Portland Avenue South 5600 JB Eindhoven The Netherlands Burnsville Minnesota 55337 USA Phone 31 40 2577 284 Phone 1 800 392 3497 Fax 31 40 2577 330 Fax 1 800 955 6831 emea securitysystems bosch com audiosupport US bosch com www boschsecurity com www boschcommunications us Bosch Security Systems Inc 2009 Data subject to change without notice 74062825227 Cur en US V12 16 Mar 2009 Asia Pacific Represented by Robert Bosch SEA Pte Ltd Security Systems 38C Jalan Pemimpin Singapore 577180 Phone 65 6319 3453 Fax 65 6319 3499 apr securitysystems bosch com www boschsecurity com
6. line input output 1 x Cinch connector pair telephone input output 1 x Cinch insertion input output 2 x Cinch connector pairs R L channel external recorder input output e USB interface CCS CUR CCS CURD 1 CCS CUD CCS CURD 2 CCS CUR CCS CURD Parts Included Quant Component 1 Control Unit 1 50 dB Attenuator 1 User manual 1 Power cord CCS CU Control Unit 3 Technical Specifications Electrical Mains voltage 100 to 240 VAC 10 Current consumption maximum 0 9 A 100 VAC to 0 3 A 240 VAC DC supply to 24V 1 V current limited contribution units Loudspeaker volume con mute 50 dB att 10 steps of 1 9 dB trol Limiter threshold levelto 10 dB above nominal level loudspeaker head unit phone Gain reduction duetonum NOM 1 dB ber of open microphones NOM Total harmonics Nominal input 85 dB SPL lt 0 5 Max input 110 dB SPL lt 0 5 Sample frequency CCS CUR CCS CURD Recording Playback 32 kHz 32 44 1 48 kHz Bit rate CCS CUR CCS CURD Recording Playback 64 96 128 192 256 KBit sec any bitrate Compatible conform ID3V2 mp3 tags CCS CUR CCS CURD Memory card Any SD Card up to 2 Gb high speed cards ad vised Recording capacity CCS CUR CCS CURD Internal memory Bitrate 225MB 64 07h 41m 96 05h 07m 128 03h 50m 192 02h 33m 256 01h 55m Mechanical Card size 512 MB 1GB 2GB 17h 14m 34h 28m 64h 56m 11h 29m 22h 59m 45h 58m 0
7. n be active at any one time Note In override mode delegates cannot override chairmen e Chairman only mode only chairmen can speak Delegate microphones cannot be activated even when a chairman is not speaking e Test mode checks if system connections are correct All microphone light rings and contribution unit LEDs light up to indicate that units are properly connected Supplies power for up to 50 contribution units The CU has two trunk outputs for the loop through connection of contribution units It is possible to connect 25 contribution units to each trunk output with a maximum system cable length of 100 m 109 3 yards Provides control for up to 150 contribution units Up to 3 CUs can be used together in a discussion system to power and control a maximum of 150 contribution units In this configuration a single CU acts as a master controller for the entire system Built in monitor loudspeaker The built in monitor loudspeaker and headphone socket allow the conference to be monitored Interfaces the system with external equipment The following equipment can be interfaced to the CCS 800 Ultro Discussion System through the CU e External wired or wireless microphone for guest speakers or audience participation Note The external microphone is muted when the priority button ona chairman unit is pressed and when the system is operating in chairman only mode e External PA system for transmitting the proceedings
Download Pdf Manuals
Related Search
CCSCUControlUni_Data..
Related Contents
Pharmazeutische Bedenken - Deutsches Apotheken Portal 28229 Video Borescope - York Survey Supply Centre ICam Plus Usermanual EVGA X58 SLI REPASSEURS - Les rasophiles d`Oc et d`Oil 取扱説明書(PDF)はこちら Samsung Galaxy S4 Active Manual de utilizare(Jellybean) Manual - Swiminn WamBam Fence VF13002 Installation Guide Copyright © All rights reserved.