1. CO2Meter com CO2 Meairement Specialists Software amp Documentation Downloads Gaslab Sensor Configuration amp Data Logging Software aslab is cur mrt generation software specifically designed for all CO2meter supplied sensces developenent bots ar Figure2 GasLab download page Internet Explorer 11 shown Follow the steps and instructions prompted by your computer s operating system Make sure you have administrator privileges in order to install this program NOTE We strongly recommend allowing GasLab to install drivers for the sensor automatically Software Capabilities Our GasLab software will allow users to e Manage and download logs e Calibrate the sensor e Configure sensor e Collect data real time e Adjust logging intervals PAGE 6 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Powering the Unit This meter can be powered by four 4 AA size batteries not included but sampling units can also be powered by the included 6VDC international wall power supply These units should NOT be powered using the included USB cable since it supplies inconsistent voltage to the meter which degrades sensor accuracy If the unit is not going to be used for an extended period of time batteries should be removed to prevent damage due to potential battery leakage The power switch 4 on the left side of the meter turns the unit ON OFF The LOG switch on the right side of the meter enables disables data
2. IMPORTANT MAKE SURE TO INSTALL SOFTWARE BEFORE CONNECTING YOUR METER TO YOUR COMPUTER 1 Install fresh set of AA batteries Duracell brand recommended or connect the included power supply 2 Install filters and tubing included 3 Turn the meter ON by pressing the power switch once 4 For data logging models turn logging ON by pressing the LOG switch once Once the sampling process is completed data can be downloaded to your computer using our GasLab software Calibration These meters are factory calibrated with multiple gas concentration reference points and have been verified to be accurate within its specific functionality before shipment However if they are severely jolted or otherwise mechanically disturbed the internal sensor can drift requiring recalibration All calibration procedures follow a single point calibration routine that effectively shifts the zero point of the internal sensors PAGE 13 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com To Calibrate at 0 pom Connect the seneerto a Nirogen Source and cick Calibrate to Zero PPM Percentage Use this to Calibrate to a knewn concentration Figure 8 Sampling calibration screen for 50 CO2 100 CH4 Calibration can be performed using either 0 calibration gas typically nitrogen Argon etc or using a fresh source of air assumed to be approximately 400ppm CO2 and 0 CH4 Attach the calibration gas to the
3. period of time in a specific logging interval This screen also gives you the option to set the desired pump interval Remember to synchronize the pump before during or after the logging interval to read and collect the correct reading according to the application Data Logs Will take you where the logs are and you can see the data storage on your device and display it graphically in the same window Data Logging Configuration These meters feature an internal memory capable of storing data when not attached to a personal computer These units will allow you to simultaneously read and store CO2 and CH4 concentrations level data Due to the nature of their design this meter should be connected to your personal computer first before operation to initialize and set the logging period and real time clock SAMPLING DEVICE Vacuum Pump Humidity Filter EXPERIMENTAL CHAMBER Sensing Chamber Figure 5 Closed loop operation aar inlet SAMPLING DEVICE Recommended Vacuum Pump Humidity Filter EXPERIMENTAL CHAMBER Sensing Chamber Environment Figure 6 Opened loop operation We recommend installing the included humidity contaminate filter to ensure the sensing chamber and pump baffle stays clear and corrosion free PAGE 12 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com SAMPLING DATALOGGER Cod Meter cor USA Figure 7 Filter Installation and Orientation Quick Start Guide
4. logging and pump function Product Overview This portable CO2Meter Inc sampling data logger or sample draw meter is designed to monitor carbon dioxide CO2 and methane CH4 simultaneously in real time The warm up period is 2 minutes Sampling data loggers log data for a specified period of time and store up to 60 000 data points to its internal memory to be retrieved at a later time for analysis When combined with our GasLab software it allows you to see data in real time on your computer s screen Its built in 1 000 hour 10 000 hour optional sampling micro pump ensures reliable operation for persistent readings based on user selected time intervals This meter is ideal for the following applications e Natural gas processing e Algae based biogas production e Fermentation monitoring and validation e Agricultural CO2 up take analysis Scientific devices such as this oxygen meter require users to have intimate knowledge of the sensor s features limitations operation required software and specifications prior to use CO2Meter Inc highly recommends reading this user s manual before operating this sensor especially the Important Safeguards section on page 4 This meter allows you to simultaneously monitor carbon dioxide and methane in concentration levels from zero to 50 and 100 respectively PAGE 7 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com USB Connector covered Connect included USB cable
5. to communicate with unit Instrument Overview USB Connector cover removed Barb Fitting x2 Connect tubing for closed loop sampling Power Switch LOG Switch Outlet Turns the meter Turns logging ON OFF a E mg ON OFF Display Rubber Boot x2 shows CO2 CH4 Protects meter concentration and improves grip level data logging and free eal ene Connect included memory space Figure 3 CO2 CH4 meter components power supp PAGE 8 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com LCD Display The Liquid Crystal Display LCD shows the following features e CO2 CH4 levels in percentage 4 format e Logging ON OFF e Percentage of free memory Data Storage This meter features an internal memory capable of storing 60 000 data points Due to the nature of the design this meter will need to be initialized before operation and the logging period and real time clock will need to be set under the SETTINGS menu Detector Principal This meter features a single gas sensor used to detect both carbon dioxide and methane simultaneously This sensor uses proven NDIR non dispersive infrared technology to sense concentrations of these two gases in the air as a function of transmitted light The optics in this dual sensor insures good selectivity of these two gases as well as a long service life Operation Guide Make sure you read through these instructions thoroughly before using the meter This
6. OPERATION GUIDE E 9 CONNECTING IER 10 LOG NC DA E 10 FOR EACH LOGGING SESSION ssssssssssssrssssresnesnssnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn nennen 10 SETUP passia aa 11 SAMPLING DATA EE deeg 11 SETTINGS ani 11 BD PA GETTING aea e e E e e a a a in 11 POTE ETIN aa E EE E 11 TIME DATE NR 11 Biere e 12 DATA LOGGING CONFIGURATION s sssssssssesessnsnssscssorecacesesesenensnsnsconaracacaeaesesesenenensnscarocanas 12 QUICK START GUIDE E 13 CALIBRATION Seerne neen EEEO EEEE 13 CALIBRATION PROCEDURE reece scape pte cs ei aaa seco ve ccd ales erea 15 APPENDIX eegener 16 ig 9S 2 GH FV 6 Seen rene nee ne ee ene ne eee eee 16 TROUBLESHOOTING GUIDE sssssssssnnsnnsnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnn nnmnnn 17 USB DRIVER INSTALLATION INSTRUCTIONS cscsssssssssssssssesseseesecscacaeeseseseseseseseeesasaeanaeaeas 18 OT KE 18 WARRANTY cee eases caneieananebees 18 LIABIDIT Y ciceaas ceases cee savesntees aknanienenaus puna cunavivietvoehuadveansutsvesesuaisavecapernceavencdeivats 19 RETURNS inan 19 CONTACT US epaia ARTEN 19 PAGE 3 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Welcome Thank you for purchasing this device from CO2Meter Inc a Florida based business specializing in the design and manufacturing of gas detection and monitoring devices mainly CO2 Our approach is one based in the science of gas and how best to accurately and repeatedly measure that gas for the end use
7. TCO2Meter com CO2 Measurement Specialists User s Manual 50 C02 amp 100 CH4 Sampling Data Logger OUT IN a DATALOGGER cp CO2Meter com USA Model Covered CM 0191 WARNING Install our complimentary GasLab software before connecting your CO2Meter product s to your computer Failure to do so may affect the ability for GasLab to detect your sensor Save sensor information for future reference Model Number Serial Number Purchase Date www CO2 Meter com Copyright 2015 CO2 Meter Inc All Rights Reserved Rev 15 September 2015 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com WARNING Install our complimentary GasLab software before connecting your CO2Meter product s to your computer Failure to do so may affect the ability for GasLab to detect your sensor If this happens please follow the instructions shown in the USB Driver Installation Instructions section on page 18 of this manual PAGE 2 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Table of Contents TABLE OF CONTENTS EN 3 WELCOME EE 4 IMPORTANT SAFEGUARDS nsssssnssnnnunnnsunnunnnnnnnnnnnnunnnnennnnnunennnnnnnennnnnnnennnnnnnnnnnnnnn nnn 4 SOEN aiaa 5 OPTIONAL ACCESSORIES siscicscisscacsccsvcticssencn cece EENS 5 GASLAB ENEE aaaeaii 5 MINIMUM SYSTEM REQUIREMENTS eccsssssssesscsssscssseusevsevsessessesesseusevsevaesaeseuseuseusevaevaevasseusenaes 5 POWERING THE UNG WE 7 NIESEN 7 EE 9 ie OR te 9
8. ent 0 5 W avg pump running WxHxD 3 60 91 x 5 75 146 x in mm 1 29 33 excluding boot CO2Meter com PAGE 16 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Troubleshooting Guide Symptom Possible Cause Resolution Issue Unit is not Make sure unit is connected properly to a recognized by suitable 6VDC power source and that the USB computer OS cable is properly connected to a computer power ON there is adequate power to the sensor No logs are The meter was disconnected while logs were present on being downloaded Connect the meter to the meter computer and download logs again The display is The meter s EEPROM has been corrupted blue or showing Improper power supply Please email our error technical support for further assistance The GasLab Your software might be out of date Update your software doesn t software online at our website or by clicking on start 1 the CHECK FOR UPDATES under the Help menu Make sure your computer meets the minimum system requirements Slow response Check the air flow channels tubes to make sure they are not obstructed Check the parameters of the meter and make sure the speed of the computer is adequate Reading doesn t Calibration or recalibration needed change For more troubleshooting tips on GasLab software see its manual located at www co2meter com pages downloads PAGE 17 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Mete
9. eparable damage to this device 4 Do NOT use rechargeable AA batteries Duracell brand AA Alkaline batteries are recommended e 6 Do not store the meter with the AA Alkaline batteries installed to prevent the potential for battery leakage 7 Make sure that the tubes are securely attached to the meter before sampling a closed environment 8 Do not operate with an obstructed sample path 9 This meter is not designed for outdoor use 10 Do not expose this meter to water or any liquids 11 Do not operate this meter if the enclosure is opened 12 Do not operate the device if it is malfunctioning SAVE THESE INSTRUCTIONS PAGE 4 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Package Contents Please verify that your package contains the following items before using this meter UNITS e 1 Meter e 1 6 foot USB cable e 1 International power supply e 1 High impact carrying case e 1 Calibration Tag e 1 User manual e 1 Fittings tubing amp filter kit o 1 10 foot long 1 8 tubing 2 1 8 Barb tubing bulkhead fitting 2 1 8 Barb 10 32 UNF fittings 2 Particulate filter CM 0117 2 Hydrophobic filter CM 0118 Figure 1 Basic kit all units 1 Moisture trap CM 0112 O O O O O Optional Accessories If the meter is to operate in environments where humidity is very high gt 95 RH an Extreme Moisture Filter CM 0103 can be purchased separately This filter will allow
10. er 4 Wait until the display changes colors to visually confirm it has reset successfully after connecting it to a computer Connecting Meter The first time the meter is connected to your computer the operating system will install the necessary USB drivers as shown in Figure 4 This process could take a few minutes Your device is ready to use USB Serial Converter off Ready to use USB Serial Port COM10 off Ready to use Figure 4 USB Driver Installation Logging Data Once the GasLab software has been installed and the meter is connected to the computer you can gather data in a variety of ways Data can be collected in real time data logs can be downloaded from the meter s memory and saved to the computer and data can be reviewed on the meter s LCD display For each logging session 1 Turn the meter ON by connecting to power supply 2 The meter must be started at least 1 minute prior to deployment and data logging to allow the sensor enough time to warm up and calibrate 3 Set the logging interval as desired using GasLab Turn the Log switch to the ON position in order to start the logging session 5 When data logging is completed turn the Log switch to the OFF position in order to stop the logging session and disconnect the meter NOTE Refer to the GasLab User s Manual for more information PAGE 10 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Setup CO2Meter Inc s sampling met
11. er operation of the unit All models have an internal coin cell CR 2032 3V battery backup for the real time clock This battery is inserted in the factory for your convenience and should last the lifetime of the product Settings Settings allows you to access all the parameters options outputs communications and date time settings to be changed or programmed Display Settings Here you can change the brightness and color theme 3 available on the device and you can also activate a Screen Timeout to save power This setting will not affect the meter s functionality but will affect the battery life depending on how you set this parameter Port Settings Here you can configure and activate ports that control additional accessories such as the device Modbus address Please call technical support for guidance and important information before making changes to the configuration of any of these ports You can reach us during regular business hours at 386 256 4910 or send us a message to support co2meter com Time Date Settings Here you can change the date and time on the meter for more accurate reference on the records The default time of your meter could vary depending on your location Review these settings before you start using the meter PAGE 11 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Logging Settings Here you can change the logging interval and duration This will enable you to collect the data for a
12. ers will require minimal setup since they are designed to be portable The most important aspect of the setup involves connecting the sampling hoses and ensuring proper setup The Instrument Overview section shows the labeled components of these meters as referenced throughout the rest of this manual Data Logging Models These models feature an internal memory capable of storing data when not connected to a computer These units will allow you to simultaneously read and store CO2 concentration level data Due to the nature of their design these units should be connected to your computer first before operation in order to initialize and set the logging interval and real time clock Insert four 4 AA size batteries into this unit or connect the unit to the included power supply In order to initialize data logging functionality the unit MUST be connected to the computer with data logging switched to OFF and the GasLab software started Once the unit has been connected click on the Configure Sensor button in the GasLab interface and set the pump period and data logging interval as desired We recommend leaving the pump on period to the default 10 seconds For the data logging interval we recommend 10 or more seconds The pump PWM period can also be adjusted for advanced applications with 1 being full duty cycle and values approaching 255 being the shortest duty cycle The pump mode should always be set to Data logging for prop
13. f the problem and any relevant troubleshooting information or steps taken so far so we can duplicate the problem and quickly respond to your inquiry Warranty This sensor comes with a 1YEAR warranty period limited manufacturer s warranty starting from the date the sensor was shipped to the buyer During this period of time CO2Meter com warrants our products to be free from defects in materials and workmanship when used for their intended purpose and agrees to fix or replace at our discretion any part or product that fails under normal use To take advantage of this warranty the product must be returned to CO2Meter com at your expense If after examination we determine the product is defective we will repair or replace it at no additional cost to you This warranty does not cover any products that have been subjected to misuse neglect accident modifications or repairs by you or by a third party No employee or reseller of CO2Meter com s products may alter this warranty verbally or in writing PAGE 18 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Liability All liabilities under this agreement shall be limited to the actual cost of the product paid to CO2Meter com In no event shall CO2Meter com be liable for any incidental or consequential damages lost profits loss of time lost sales or loss or damage to data injury to person or personal property or any other indirect damages as the result of use of our prod
14. free flow of sampled air while keeping moisture out of the meter A 10 000 hour pump is also available at the time of purchase Note Please contact our technical support staff for more details about these or any other accessories Ua GasLab Software et IMPORTANT MAKE SURE TO INSTALL SOFTWARE BEFORE CONNECTING YOUR SENSOR TO YOUR COMPUTER Minimum System Requirements To utilize our free software the computer must meet the following minimum requirements e 1GHz processor with 1GB of RAM 1GB free disk space 2GB free disk space for 64 bit systems e Windows XP 7 8 8 1 with Microsoft NET Framework 4 0 or later e On Intel based Mac computers GasLab software can run using a Windows 7 8 virtual machine software such as VMware Fusion or similar Microsoft NET is not supported on Media Center or Tablet editions Installer will optionally install NEI Framework PAGE 5 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Visit www co2meter com pages downloads to download our complimentary GasLab software to your computer You can also download the GasLab user manual in PDF from this page Please read the GasLab user manual carefully to become more familiar with how the software works so that you can get the maximum benefit from this useful tool Install the GasLab software first to ensure that the proper driver necessary for the sensor is installed on your computer before connecting the sensor
15. guide will help you become more familiar with the meter in order to be as productive as possible in a short period of time Please read the Important Safeguards on page 4 before continuing IMPORTANT Follow these instructions to ensure proper set up 1 Download the GasLab software to your computer as shown in the Package Contents Please verify that your package contains the following items before using this meter UNITS e 1 Meter e 1 6 foot USB cable e 1 International power supply e 1 High impact carrying case e 1 Calibration Tag e 1 User manual e 1 Fittings tubing amp filter kit o 1 10 foot long 1 8 tubing 2 1 8 Barb tubing bulkhead fitting 2 1 8 Barb 10 32 UNF fittings 2 Particulate filter CM 0117 2 Hydrophobic filter CM 0118 1 Moisture trap CM 0112 O O O PAGE 9 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Optional Accessories If the meter is to operate in environments where humidity is very high gt 95 RH an Extreme Moisture Filter CM 0103 can be purchased separately This filter will allow free flow of sampled air while keeping moisture out of the meter A 10 000 hour pump is also available at the time of purchase Note Please contact our technical support staff for more details about these or any other accessories 1 2 GasLab Software section on page 5 3 Power the meter using the included universal power supply Turn ON the met
16. llow these steps 1 2 Turn ON the meter Connect the unit to a calibration gas bottle cylinder 100 nitrogen or a specific C02 CH4 calibrate gas with the appropriate demand regulator Wait 25 seconds to collect a sample Write down this value as the before value Click the CALIBRATE ZERO or CALIBRATE SPAN button after selecting your calibration gas Wait 25 seconds again This time the meter will take a sample and use this data to adjust zero values The displayed measurement will show the new calibration value 0 or depending on method used Disconnect the calibration gas and wait 25 seconds All displayed data will now be based on the new calibration value Repeat this procedure if the sensor is still operating outside of its specified range or if readings vary greatly PAGE 15 of 19 CO2 CH4 Sampling Data Logger User s Manual Appendix Meter Specifications Sanco VE Non dispersive Infrared ER NDIR 0 500 000 ppm 50 C02 Sensor Measuring 021 000 000 ppm 100 Performance Range CH4 ae SES DEE 3 0 50 full range d 5 gt 50 full range Life Expectancy General Maintenance l l No maintenance required mervat NO maintenance required aa 60 000 BENS Programmable Date time CO2 CH4 CM 0191 only Interval Data Max Flow STP 0 40 liters min Pump 150 mbar Characteristics 500 mbar CM 0191 onl Pressure Four 4 AA sized Alkaline Power Input Voltage 6 VDC Curr
17. meter and connecting the meter to a computer Open the calibration screen in the GasLab software Click the CALIBRATE button in the calibration tab for the desired gas located in the CONFIGURE SENSOR screen As long as the gas concentration is stable the unit should instantly reflect the calibrated value This can be confirmed by watching the LCD display on the unit To see the calibration value in real time click in the COLLECT REAL TIME button to capture these values before opening the configuration screen Real Time Gas Level go 4 8 54 00 AM 8 55 00AM 8 56 00AM 8 57 00AM 8 58 00AM 8 59 00AM 9 00 00AM 9 07 00 AM X Axis EN iii PPIP ARR EEFEFTEFE Se e ell l D Ce Lei E TILL E F Figure 9 Collecting data in real time PAGE 14 of 19 CO2 CH4 Sampling Data Logger User s Manual CO2Meter com Blab v2 0 7 12 Real Time Gas Level 12 00 00 AM DUU OU AM 12 00 00 PM 6 00 00 PM 12 00 00 AM X AMIS Log Files December 23 2013 cav a Sj 01 07 14_DownloadedLog cay EE Febaumrm D 3 2014 csv ali 00i _DounioadedLog er Fosse February fe 2014 cov March 18 2014 ce 03 20 14_DownloadedLog crv z 03 20 14_DownloadedLog T cav duly 15 20 14 csv EN 22 2014 cs au duly 31 2014 cov duby 3 1 201 411 csv Oniy Show Selected Sensor Selected Device Auto on Port COMI44 https co2metercom Figure 10 Calibration screen options Calibration Procedure To calibrate your meter fo
18. r com USB Driver Installation Instructions To install the appropriate USB port drivers compatible with your sensor follow these steps 1 Go to http www ftdichip com Drivers VCP htm and download the package appropriate for the version of Windows installed in your computer 2 Move the file you downloaded to a location you can easily access Make sure you have administrator privileges 3 Extract the file by right clicking on it and selecting extract here 4 Goto your computer s Device Manager in the Control Panel e For Windows 8 press the Windows key and x at the same time to bring up the start menu then click on Device Manager e For Windows 7 open the start menu and type Device Manager in the search bar 5 Find the Unrecognized USB Device in the list it usually but not always has a yellow triangle icon 6 Right click the Unrecognized USB Device item and select Update Driver Software 7 Select Browse My Computer and point to the folder where you extracted the driver files to step 3 This will install the necessary drivers to your computer and allow you to use your sensor with GasLab If you have multiple sensors you should only have to perform this procedure once the operating system will automatically find the driver for all the other sensors Support The quickest way to obtain technical support is via email Please send all support inquires to support coZmeter com Please include a clear concise definition o
19. rs purposes Our business partners in Agriculture Medical Pharmaceuticals Science Beverage and other fields find our devices to be highly accurate and cost effective We approach each customer s application as a unique opportunity to understand educate and provide product solutions that meet the customers needs while exceeding their expectations for reliability and service Our continued product innovation in combination with our customer first focus allows CO2Meter Inc to continue to provide solutions for the future Based in Ormond Beach FL CO2Meter Inc is committed to the success of our customers the health welfare and prosperity of our talented employees and the continued development of our local community CO2Meter Inc appreciates your business and looks forward to working with you and your team in the future Please take some time to read through this manual in order to become familiar with the sensor Also please pay special attention to the important safeguards shown on the next page Important Safeguards To reduce the risk of fire electrical shock and or injury to persons basic safety precautions should always be followed when using electrical appliances including the following 1 READ ALL INSTRUCTIONS BEFORE USING THIS SENSOR 2 INSTALL THE GasLab SOFTWARE BEFORE CONNECTING METER TO A COMPUTER 3 Use only the included power supply to operate this meter Inappropriate voltage supply could cause irr
20. ucts Returns If the product fails under normal use during the warranty period a RMA Return Material Authorization number must be obtained from CO2Meter com After the item is received CO2Meter com will repair or replace the item at our discretion To obtain a RMA number call us at or email us at 386 256 4910 support co2meter com When requesting a RMA please provide reason for return and original order number If we determine that the product failed because of improper use water damage dropping tampering electrical damage etc or if it is beyond the warranty date we will inform you of the cost to fix or replace the product Contact Us We are here to help For information or technical support please contact us support co2meter com te 386 256 4910 Technical Support 386 872 7665 Sales www co2meter com Address CO2Meter Inc 131 Business Center Drive Ormond Beach FL 32174 USA PAGE 19 of 19