Home

VC60B User manual - Zhuhai E-one Science and Technology CO

image

Contents

1. 2 250v soov 1000V 750V r Z COCCO a 25000v 2000 M POWER mo al i l mVA aj A wea go ia q q D mkQ 5 oN Gana o PRE Rg Copes NS s S LS R CONT Outer DC power socket Gear selected key press Measuring range key press Hand strap position Power key press Test key press spin to lock Display screen aN DOA FP WYN Measurand ground terminal connected socket 9 Voltage input terminal 10 Ground terminal connecting to protect the ring electrode when testing for the cable 11 Tested terminal socket Operation Turn on the instrument by pressing the power key press Please replace the batteries timely when the low power symbol displayed 5 1 Insulation testing 1 Connect the measurand ground terminal with the input wire E and connect the tested terminal to L Make the L terminal connection hand in the air as much as possible Please connect to the COM terminal when testing for the cable 2 According to the detecting mission select the proper gear then LCD will display the corresponding voltage if the tested voltage is unclear try from the low gear when it show as 1 change to the higher gear to continue 3 Select the proper measuring range press the TEST key then the Land E terminal will have high voltage output LCD display symbol the high voltage indicate light will light up 4 Press down the TEST key to progr
2. COM terminal with the black one 2 Full contact two tested terminals and parallel to the electric power with the testing probe The readout on the LCD screen is the measuring result 3 If the LCD displayed as 000 it indicates that the tested voltage is zero or the connected wire may be disconnected Maintenance 1 This instrument is a precision measuring instrument please avoid using under bad environment it s not allow to change the circuit replace the component and calibrate and repair the meter without obtaining the authorization of the Product Service Center of our company 2 1f there is no display on the LCD even when there is power left then please check the connecting condition of the batteries 3 The batteries should be replaced when the low power symbol displayed Make sure the measuring circuit is cut off Loose the screw of the battery box take out the batteries and install the new one please pay attention to the polarity after that put back the cover and fasten with screw 4 If you don t use the meter for a long period please take out the batteries to prevent the electrolyte leakage which may affect the usage of the meter or even damage the meter Further service Please full read this user manual carefully before using If you have any further question during your usage please feel free to contact us Tel 0756 8659101 Skype e one caroline QQ Wechat 373234353 Website http e e one
3. net cn
4. Create the 3thera The waveform display multi meter ie A 0 1MQ 2GQ m Insulation tester VC60B 250v soov 1000V 750V CILIL IL f 25000 s000v a h mVA Pra a Toy Press D Xi ss AA O FoR cont Design and Manufacture by Zhuhai E one science and technology Co Ltd The professional manufacture Ne VC60B VC60D 3 1 2 digits digital display AC Voltage Insulation tester User manual Digital intelligent insulation meter re Features 1 Adopt 6 1 5V batteries more durable 2 Bigscreendesignwith bigfontdisplayand LED backlight which makesthe viewing more directandclear 3 Voltage 250V 500V 1000V VC60 500V 1000V 2500V VC60D 4 Press lock function in measuring 5 Protection optimized enabletobearing surgeofshort curcuitand residual voltage Summarize VC60B VC60D AC voltage Insulation tester adopts DC voltage changer which is low consume carried high voltage ratio and inductance power stored It transits the 9V voltage into 250V 1000V 2500V and process the insulation test with analog digital circuit Widely use in solving problems of electrical equipments and system Technique features 1 General feature Display 80X52mmLCD display LED back light Max display 1999 Over range indicate LCD shows 1 when it s over range Supply 6 1 5V batteries or ou
5. ess the measuring readout the value when it display stable Release the TEST key when finished the LCD will display 1 If the TEST press key down but the LCD still display 1 it s possibly cause by A The tested resistance has over the selected range or over the Max measuring range B The wire maybe not being well connected or disconnected Digital intelligent insulation meter ne 5 Press the TEST key and spin clockwise to lock and measuring continuously 6 Caution It s prohibit from pushing pulling the connecting wire or touching the tested resistance when the TEST key is being press down cause the L and E terminals will have high voltage output If the readout bing unstable all the time it s possible because A The connecting wire is too long B The humidity of the testing environment may be alittle high C The outer layer of the tested resistance need to be connected to the COM D The tested resistance is unstable lies in critical state 7 When progressing the insulation test please use the conductor to protect around the measurand s appearance between the two tested terminals in order to eliminate the measuring inaccuracy which generated from the current s leakage of the measurand s appearance Plus the protected conductor should be connected to the COM terminal with the wire 5 2 AC Voltage measuring 1 Press the gear of 750V connect the ACV terminal with the red test pen and the
6. ter DC9V 1A power adapter Caution Batteries and adapter can t be use simultaneously Low voltage indicate a Symbol shows static consume About 10mA Max Current About 280mA Using condition Temperature 0 C 40 C Humidity30 RH 80 RH Storage condition 10 C 50 C Relative humidity lt 85 RH Dimension 185 115 65mm Weight About 500g Including batteries Accessory 1 User manual 1 test pen 1 test clamp 2 Specification 2 1 Insulation test Model Voltage Gear Measuring range Resolution eccrine Accuracy 200MQ 5M 200M 0 1M 10M 250V 2GQ 50M 2G 1M 20M B 200MQ 5M 200M 0 1M 10M 4 8d 500V 2GQ 50M 2G 1M 20M 200M 5M 200M 0 1M 20M 1000V 2GQ 50M 2G 1M 200M 10 5d 2000MQ 10M 2000M 1M 10M 500V 20GQ 200M 20G 10M 20M 2000MQ 50M 2000M 1M 50M 4 5d D 1000V 20GQ 500M 20G 10M 50M 2000MQ 100M 2000M 1M 100M 2500V 20GQ 1000M 20G 10M 500M 15 5d Note Medium resistance is a measuring lower value which indicates and ensures that when operating the voltage won t be lower than 90 of the tested voltage 2 2 AC Voltage measuring Range Resolution Accuracy 750V 1V 1 0 3d AC frequency response 40Hz 400Hz Display Sine wave RMS Average Digital intelligent insulation meter re illustration ae A 1 f Insulation tester VC60B

Download Pdf Manuals

image

Related Search

Related Contents

Bedienungsanleitung - CGS Prozessanalytik  Arena SA-4551S storage server  Annuaire des fournisseurs Bio Guide Restauration Hors  取扱説明書  Weider WEEVBE3722 User's Manual  購入目安・メンテナンス等(PDF・約170キロバイト)  PULVERIZADOR AGRÍCOLA CHAMPION-2000 PASTUS  VTech DECT DS6121-5 User's Manual  Philips CED1910BT  Makita HW102 high-pressure cleaner  