1. Line adaptor 110 240Vac to 15Vdc 800mA For full technical specifications download the user s manual from our website Your local distripUtOr cee CAS Dataloggers 8437 Mayfield Rd Chesterland OH 44026 800 956 4437 www dataloggerinc com
2. Calculated Channels Combine values from analog digital and serial sensors using expressions involving variables and functions Functions An extensive range of Arithmetic Trigonometric Relational Logical and Statistical _ functions are available Alarms Condition high low within range and outside range Delay optional time period for alarm response i Actions set digital outputs transmit message execute _ anydata Taker command Scheduling of Data Acquisition Number of schedules 11 Schedule rates 10ms to days Data Storage Internal Store Capacity 128MB approx 10 000 000 data points Removable USB store device i optional accessory _ Types compatible with USB 1 1 or USB 2 0 drives e g Flash drive Capacity approx 90 000 data points per megabyte 2 Communication Interfaces Ethernet Port Interface 10BaseT 10Mbps Protocol TCP IP Modbus Slave Host RS232 Port Speed 300 to 115 200 baud 57 600 default Flow Control Hardware RTS CTS Software XON XOFF None Handshake lines DCD DSR DTR RTS CTS Modem support auto answer and dial out Protocols ASCII Command TCP IP PPP Serial Sensor Modbus Slave Network TCP IP Services Uses Ethernet and or Host RS232 PPP ports Command Interface Access the ASCII command interface _ of the DT82E via TCP IP Web Server _ Access current data and status from any web browser Custom HTML pages can be defined Download data
3. ble to store up to 10 million data points expandable you can log as much or as little as you need Overwrite or stop logging once allocated memory is full archive data on alarm event copy to USB memory or transfer via FTP the choice is yours Communications features include RS232 USB and Ethernet connect to the DT80 locally remotely through a modem or over the Internet The web interface allows users to configure the DT80 access logged data and see current measurements as mimics or in a list using a web browser FTP provides data to your office over the internet or mobile phone network without the need for polling or specific host software www datataker com Easy configuration ewe ll The dEX configuration editor allows you to view edit and save logger Built in software no a ppl ication to insta configurations in an easy to use Windows Explorer style user interface Runs directly from your web browser Accessible by Ethernet or USB connection Intuitive graphical interface Easy to use configuration editor Access live and historical data View data as charts mimics and tables Real time monitoring dEX displays real time sensor measurements calculations and diagnostic information using mimics tables and trend charts What is dEX dEX is an intuitive graphical interface that allows you to configure your data logger view real time data in mimics trend charts or tables and retriev
4. button press Configuration editor The configuration editor allows you to view edit and save logger configurations in an easy to use Windows Explorer style user interface Tree view of configuration allows definition of measurement schedules and measurements Wiring diagrams show available wiring configurations for each sensor type Configuration can be stored and retrieved on either the logger or a local computer J Platinum RTD 4 wire Voltage bridge Chart recorder mimic Channel list Displays name value units alarm state time stamp and logging State for each measurement Eum i Ao Veu Uris Arm Time vimp Ley a ihe _ Kure i RH Se deoad 13 0 0 ba bre Mea Win 6 mi ISA Linke G bie Hammin 7 POLOHOTHO Le E phe Pwa 1G hPa JULHAN LPEN Og a G whe Teeooet 216 m Sod 13 00 00 Customisation of the application The menu options mimics panels and mimics can be added or removed to sult novice or advanced users The color and brand name images within dEX can be customised to match corporate requirements or for personal preference Mimics are organised into panels which can be modified to highlight custom alarm conditions or data grouping Mimics include dials bar graphs thermometers etc Real time chart recorder mimic allows you to view trends and historical data over a custom time date range Up to 16 mimics can be displayed on up to 5 mimic pages default is 1 page of 6 mimics Minimum syste
5. datalaker Low power design for remote applications Dual Channel Isolation Technology 1 SDI 12 input Serial Smart Sensor port FIP for automatic data transfer Modbus for SCADA connection Up to 6 Analog 30V sensor inputs USB memory for easy data and program transfer Warranty All datalaker Data Loggers are covered by a 3 year warranty on workmanship and parts For further information on the data Taker range or for useful downloads visit the data Taker web site at www datataker com or contact your nearest data Taker office or distributor Quality Statement dataTaker operates a Quality Management System complying with 1 S09001 2008 It is datalakers policy to supply customers with products which are fit for their intended purpose safe in use perform reliably to published specification and are backed by a fast and efficient customer support service Trademarks data Taker is a registered trademark Specifications data Taker reserves the right to change product specifications at any time without notice Designed and Manufactured in Australia Qur ability to provide free software and support is dependent on applicable export control laws including those of the United States and the export policy from time to time of Thermo Fisher Scientific Inc 2011 Thermo Fisher Scientific Inc All rights reserved A B N 52 058 390 917 Designed especially for environmental monitoring Applicati
6. e your historical data for analysis dEX runs directly from your web browser and can be accessed either locally or remotely anywhere that a TCP IP connection is available including worldwide over the Internet You can use any of the logger s built in communications ports to view dEX including Ethernet USB and RS 232 Data retrieval dEX allows you to retrieve your data at the click of a mouse button Eei Den i g e bhi i h he fa im bm Ge E P habsi phbs mimm melisma ay F LE Cee oe Browser based solution dEX comes pre installed on every logger in the DT80 range The software loads in your web browser so there is no need to install cumbersome applications on your computer Being browser based dEX is cross platform and will work on all major operating systems including Windows Mac and Linux To simplify it even further dEX starts automatically in your default web browser when you connect to your logger using a USB cable Data that is compatible with your applicatons Logged data is ready to import into common spreadsheet and data processing applications such as Excel for further analysis and reporting Data can be saved to your computer in comma separated CSV format or our proprietary binary DBD format Command window The command window provides a terminal interface which allows the built in command language of the logger to be used Macro buttons allow common commands to be sent on a
7. in CSV format Command interface window Define mimic displays FTP Client Automatically upload logged data direct to an FTP server Modbus Server Slave Access current data and status from any Modbus client _ e g SCADA system System Display and Keypad Type LCD 2 line by 16 characters backlight Display Functions channel data alarms system status Keypad 6 keys for scrolling and function execution _ Status LEDs 4 for sample disk attention and power Firmware Upgrade Via RS232 Ethernet USB disk Real Time Clock Normal resolution 200us Accuracy 1 min year 0 C to 40 C 4 min year 40 C to 70 C Power Supply _ External voltage range 10 to 30Vde Peak Power 6W typical 12Vdce 500mA Average power Consumption typical _ Using 12Vdc external power source _ Ganalog samples _ Average Power mW 1analog sample Schedule Rate Average Power mW 1 sec 560 926 5 sec 250 337 30 sec 50 65 1 min 30 38 5min 14 16 30 min 1 1 1 hrs a K Physical and Environment Construction Powder coated steel and anodized aluminum Dimensions 180 x 137 x 65mm Weight 900 gram 3kg shipping Temperature range 45 C to 70 C Humidity 85 RH non condensing reduced LCD operation outside range 15 C to 50 C Accessories Included Resource CD includes software video training and user manual Comms cable Ethernet crossover cable
8. m requirements Web Browser tested with Internet Explorer V7 and above Firefox safari amp Google Chrome TCP IP connection Adobe flash player 10 or higher Screen resolution of 1024 x 768 Real time trending for sensors calculations or other data Supports up to 5 traces per chart and up to 2 Y axes Backfills with historical data stored in logger 1 USB port equipped models only 2 dEX operates on all DT80 range Series 2 amp Series 3 models DT80 DT81 DT82E DT85 DT80G DT85G The latest firmware which includes dEX is available for download from the dataTaker website DT80 range Series 1 models do not support dEX datalaker Technical Specifications Analog Channels 2 analog input channels Each channel is independent and supports one isolated 3 wire or 4 wire input or two isolated 2 wire inputs or three common referenced 2 wire inputs The following maximums apply Two wire with common reference terminal 6 Two wire isolated 4 Three and four wire isolated 2 Fundamental Input Ranges The fundamental inputs that the DT80 can measure are voltage current resistance and frequency All other measurements are derived from these Full Scale Res olution Full Scale Resolution 30mVde 0 25pV 1000 15m0 300mVde 2 5pV 10000 15m0 3 Vdc 25W 10 0000 150 00 mo 30 Vde 250V 100 Hz 0 0002 203mA 25A 10kHz 0 0002 3 MA 251A 30MA 250A Auto ranging is supported over 3 range
9. ons include Environmental Monitoring Agricultural Research Research amp Development Total Energy Monitoring Weather Stations Temperature Profiling Thermistor Arrays Aquaculture Wind Power Generation FREE Software amp Technical Support The Smarter Solution The data laker DT82 is a smart data logger designed especially for environmental monitoring The DT82E is a robust low power data logger featuring USB memory stick support 18 bit resolution extensive communications capabilities and built in display The data Taker DI82E s Dual Channel concept allows up to 4 isolated or 6 common referenced analog inputs to be used simultaneously in various combinations With advanced networking capability FTP and Web interface one SDI 12 sensor channel supporting up to 10 sensors and switchable 12V regulated output to power sensors the DI82ZE is ready to be deployed Versatile Measurement Inputs include analog and digital channels as well as high speed counters Temperature voltage current 4 20mA loops resistance bridges strain gauges frequency digital serial and calculated measurements can all be scaled logged and returned in engineering units or within statistical reporting Set up sampling logging alarm and control tasks to suit your own requirements or interface with smart sensors GPS and other intelligent devices expand the DI82E s flexibility Superior Data Storage amp Communications With the standard unit a
10. rmistor scaling and calculated channels Resistance range can be increased with the use of a parallel resistor Monolithic Temperature Sensors Types supported LM34 60 AD590 592 TMPxx LM135 235 335 Strain Gauge and Bridge Sensors Configurations 4 amp full bridge Excitation voltage or current 4 20mA Current Loop Internal 1000 shunt or external shunt resistor Digital Channels Digital Input Outputs 4 bi directional channels Input Type 4 logic level max 20 30V _ SDI 12 Output Type 3 with open drain FET max 30V 100mA 1 with logic output Relay Output 1 latching relay contacts max 30Vdc 1A Counter Channels Low Speed Counters 4 counters shared with digital inputs Low speed counters do not function in sleep mode Size 32 bit Max Count rate 10 Hz Dedicated Counter Inputs 4 high speed inputs Size 32 bit Max Count rate 100 kHz Input type 2 logic level inputs max 30V and 2 programmable inputs as either logic level inputs or sensitive inputs 10mV for magnetic pick ups max 10V Serial Channels 1 SDI 12 input a digital channel Input can support up to 10 SDI 12 sensors Generic Serial Sensor Flexible options to allow data to be logged from a wide range of smart sensors and data streams Available ports Host RS232 Port Baud rate 300 to 115 200 f used as a Serial Sensor channel then the Host Port is not available for other communications
11. s Accuracy Measurement at 5 C to 40 C 45 C to 70 C DC Voltage o o DC Current 0 15 0 45 DC Resistance 0 1 0 35 Frequency 0 1 0 25 Accuracy table above is of reading 0 01 of full scale Sampling Integrates over 50 60Hz line period for accuracy and noise rejection Maximum sample speed 25Hz Effective resolution 18 bits Linearity 0 01 Common mode rejection gt 90dB Line series mode rejection gt 35dB Inputs Inter Channel Isolation 100V relay switching Analog Section Isolation 100V opto isolated Input impedance gt 100MQ 100KQ 30v range Common mode range 3 5V or 35V on 30V range Sensor Excitation Supply Analog channels selectable 250yA or 2 5mA precision current source 4 5V voltage source or switched external supply General Purpose Switchable 12V regulated supply for powering sensors amp accessories max 150mA Switchable 5V regulated supply for powering analog sensors max 25mA Analog Sensors Supports a wide range of sensors including but not limited to those listed below A wide range of sensor scaling and linearising facilities including polynomials expressions and functions Thermocouples Types B C D E G J K N R 8 T Calibration standard ITS 90 RTDs Materials supported Pt Ni Cu Resistance range 100 to 10KQ Thermistors Types YSI 400xx Series other types Resistance range lt 10kQ Other thermistor types are supported by the