Instructions, Burglar Alarm - DSC Power-Series
Contents
1. THOROUGHBRED Post Office Box 2632 Ocala Florida 34478 2632 DSC Power Series ALARM Burglar Alarm Instructions SYSTEMS INC For complete instructions see manufacturer s published User Manual Phone 352 861 9999 e State License EF0000652 24 hour UL Certified Monitoring Burglar amp Fire Alarms Telephone Systems e Video Surveillance e Medical Alerts To cancel Dispatch for an accidental alarm for Remote Monitoring subscribers call 1 800 554 1104 and provide a valid verbal pass code Please ensure that each person understands how to Disarm and Arm the alarm system understands which doors are assigned to have an entry amp exit delay understands the difference between Arm Stay and Arm Away modes and understands how to cancel a dispatch with Central Station in the event of a false accidental alarm so as not to waste emergency response resources and to avoid potential fees or fines For security purposes we cannot provide you with your 4 digit code s or verbal password s if you forget them they would have to be reset by request in writing with signature Enter only through doors having an assigned Entry Delay using any other door will trip the Alarm The keypad will start beeping to indicate the system must be acknowledged within the allotted timeframe to disarm the burglar alarm the red Armed light will turn OFF once disarmed If you make an error press the button and start again
2. e Chime Mode on confirming that a chime occurs each time this may require two people one at the device and the other at the keypad To test communication call the Central Station and ask the operator to put your system on test for 10 minutes you will be required to provide a valid verbal pass code Arm the alarm and then trip it opening a door a window or moving in front of a motion detector waiting at least 15 seconds before disarming Call the Central Station back to verify the zone specific location for which they received an alarm 2011 Thoroughbred Alarm Systems Inc
3. entering an incorrect code more than 5 times will lock you out for 5 minutes DISARM turn OFF enter also silences an alarm 4 digit condition CODE Away Commercial ARM AWAY turn on Or Prones entry amp exit delay will be active Empty may re quire The green Ready light must be on ensure all doors amp windows are closed If the green Ready light does not come on check for Faulted zones Press and hold the referenced button for 2 seconds if Quick Arming is programmed a code will not have to be entered The only on assigned doors dioi motion detectors will be ON a paces Stay Commercial ARM STAY turn on or Properties entry amp exit delay will be active Occupied may require only on assigned doors House Icon lt digit motion detectors will be OFF ARRE Site _ or not allow keypad will only start beeping in the AWAY mode to indicate the system will turn on within allotted timeframe to allow exit Once armed the red Armed light will be on Opening a door having an entry exit delay will allow exit before the alarm activates CHECK FOR FAULTED OPEN ZONES or if green Ready light is not on lt gt For LCD Keypads press the scroll buttons to scroll through a list of open zones For LED Keypad with zone numbers printed on the keypad the faulted zones will be illuminated Full message key
4. pads will describe the Trouble fixed message and LED keypads will only identify the Trouble number TROUBLE a 1 Press 1 and reference User Manual for definitions CONDITIONS 2 Loss of AC Power if power is on check Transformer or Breaker tandieisiiminated a Mo wea ae es 3 Telephone Line Fault may be disconnected or out of service keypad beeps every 10 seconds z iets p A signal may be related to 3 above Sensor Problem call for service as needed t 2 6 Sensor Tamper 7 Sensor Low Battery to define troubles 8 Loss of Time amp Date see User Manual to correct CHIME MODE Chime if activated keypad will chime or Press and hold the referenced button for 2 seconds upon opening amp closing doors Bell Icon 3 beeps ON 1 long beep OFF or windows that have contacts Press amp hold BYPASSING each Disables a particular zone before arming the alarm 1 2 digit INDIVIDUAL ZONES ahed Disarming the alarm disables the bypass ARM INSTANT turn on For residential use during the evening someone has exit delay will be active only on Ie 4 digit to remain inside the building as you cannot open a doors having this assignment 9 CODE door without tripping the alarm once armed e a e Pt Once armed the red Armed light will be on Test Burglar Alarm system on a regular basis Open and close each window and door with th
Download Pdf Manuals
Related Search
Related Contents
User Manual - People of Lava Conditions de garantie Behringer PSU3-UK Product Information User`s Manual - Test Equipment Depot Shuttle SX58J3 barebone Whirlpool WHED10 User's Manual User`s Manual - Inventor Air Conditioners Copyright © All rights reserved.
Failed to retrieve file