Home
Module type Controller(CC-Link)
Contents
1. sw1 sw2 sw3 sw4 TS occupied Extended cyclic Vea OFF OFF OFF OFF 4stations occupied x 1 8Ch ON OFF OFF OFF 4 stations occupied x 1 16Ch OFF ON OFF OFF 4 stations occupied x 2 16Ch ON ON OFF OFF 4 stations occupied x 2 32Ch vee OFF OFF ON OFF 4 stations occupied x 4 32Ch ON OFF ON OFF 4 stations occupied x 4 64Ch If the setting of the dip switch is other than those above the actual setting will be 4 stations occupied x 1 8Ch When mounting controllers inside a cabinet with screws connect the base parts of controllers first Dimensions Fixing screws are not included Please prepare screws as required Front screw terminal cover fl SSS SS 1 Refer to the figure below for the mounting 30 optional 1 SP oy screw hole size to decide the mounting position 2 M3 19203 N Ss Ssaqq bes l ee am Pe malnuni 85 the main unit j j a AA 5 ra AE fom 6 in go e Da Z g ol SS 1 JN or i DIN rail e z kya 3 a Terminal u a ee T a eM A Ea 2 Remove the main units from the base part 2l 3022 v 5 lna eE See How to detach the bas
2. jection oF Side connecting terminal cover right amp left 1 set Front terminal block oT Internal Communication Terminating Resistance 1d 12 option CC Link 23 13 24 14 25 15 19 Vacant 17 Vacant 28 18 19 8 OeEegsegeee SI IS iGiVisiVieie This terminating resistance is different from the CC Link terminating resistance this is the terminating resistance for inter module communication Install the resistance 100 supplied with this controller Base part power terminal Power Terminal DC 24V DC 24V Note The power cables more than one should not be connected Crimp terminal size Please prepare cables and crimp terminals of the size indicated below When using a AWG 16 cable you should use the crimp terminal that material thickness is 0 9mm or less Cable type Size Thermocouple Compensation lead wire 0 25 to 1 25mm AWG 22 to 16 Power supply output others 0 25 to 1 25mm AWG 22 to 16 Crimp terminal Cable size Screw tightening torque 0 25 to 1 25mm AWG 22 to 16 3 2mm 6 0mm or less Ring crimp terminal Model c
3. Termination operand Pus NO00 E Resistance 100 Q 1 Unit User s Manual Please Read First Safety Warnings Please read this section thoroughly before using and observe the mentioned safety warnings fully Safety warnings are categorized as Warning Caution or Risk of Electrical Shock A Warning Improper use of the equipment may result in death or serious injuries Improper use of the equipment may cause injury to the user or property A Caution damage Risk of i F i Indicates that a risk of electrical shock is present and the associated A Blectrical warning should be observed P 1 A Warning 1 1 Installation and Wiring This equipment is intended to be used under the following conditions 10 to 50 degree C 90 RH or below with no condensation 10 to 70Hz less than 9 8m s 1G 30 min or more IEC1010 1 class II IEC1010 1 degree 2 Ambient temperature Ambient humidity Vibration Warm up time Installation category Pollution level Note that the insulation class for this equipment is as follows Before installing please confirm that the insulation class for the equipment meets usage requirements Power SLD FG terminal CC Link connecting terminal Loader communication CC Link communication Functional insulation AC1000V Functional insulation AC500V Functional insulation AC50V In cases where damage or pr
4. 00 System power Memory backup Communication function Compliant version CC Link Ver 2 00 1 10 Station type Remote device station Communication speed and distance re 156kbps 625kbps 2 5Mbps 5Mbps 10Mbps Cormimunigatari 1200m or less 900m or less 400m or less 200m or less 100m or less For more details refer to CC Link Cable Wiring Manual issued by CC Link Partner Association No of stations occupied Station No 4 stations Settable Station No 1 to 61 Communication data length No of stations occupied Remote input output Remote register ROMAINE Extended cyclic RX RY RWr RWw pen connectable units 4 stations occupied x 1 128 bit each 16 words each 2 or 4 units 4 stations occupied x 2 256 bit each 32 words each 4 or 8 units 4 stations occupied x 4 512 bit each 64 words each 8 or 16 units Connecting cable Connecting method Terminating resistance Ver 1 10 compliant CC Link special cable M3 screw terminal block External 110 ohm 1 2W Fuji Electric Co Ltd International Sales Div Sales Group Gate City Ohsaki East Tower 11 2 Osaki 1 chome Shinagawa ku Tokyo 141 0032 Japan http www fujielectric com Phone 81 3 5435 7280 7281 Fax 81 3 5435 7425 http www fujielectric com products instruments
5. Bl elge controller onto the upper partof os controller 4 All connected controllers are connected to 3 arere ee DiN rail power supply via side connectors if one of aooe 2 Push the controller in the controllers is directly connected to them 1 Sl G1 direction of arrow 2 DIN rail Ol Sf elg e el Bi olol elg el erg 3 Push up the locking tab to fasten the controller to DIN rail When connecting controllers after attaching to DIN rail push up the locking tab after connecting controllers How to detach the base part Press the lock lever on the top of the Lock lever controller p Pull down the upper part of main unit Detach the cutout on the lower end of back of the main unit from the projection on the base part When attaching the main unit to the base part take the reverse procedure to removing the main unit from the base part Attaching end plates Make sure that the lock lever of the When attaching controllers to DIN rails we recommend to attach side connecting ain nig ie fitted nite te Bese Patt terminal covers right and left 1set then end plates option to the ends of the right most and left most controllers Sa J K B l fff fff fff DIN rail mounting end plate T gt DIN rail mounting end plate Pr QA i
6. Instruction Manual Installation Multi loop Module Type Temperature Controller Enhanced Communication Module CC Link Model PUMCL INP TN1PUMCLb E e Front runners Fuji Electric Co Ltd Thank you for purchasing the Fuji module type temperature controller Once you have confirmed that this is the product you ordered please use it in accordance with the following instructions For detailed information on operating this equipment please refer to the separate user s manual Please keep this Instruction Manual within easy reach of persons using this equipment CAUTION The contents of this manual are subject to change without notice This manual is complied with possible care for the purpose of accuracy however Fuji Electric Systems shall not be held liable for any damages including indirect damage caused by typographical errors absence of information or use of information in this manual Confirming Specifications and Accessories Before using the product confirm that it matches the type ordered For model code please refer to page 4 Confirm that all of the following accessories are included Related Information Refer to Module Type Temperature Controller Enhanced Communication Module CC Link User s Manual for details about the items described in this manual Temperature Controller Enhanced name Communication Module CC Link 1 Unit Instruction Manual 1 copy A F Internal Communication
7. e part Imm St al p lt screw size M3 1B a 3 Connect base parts Push up to fasten all the locking tabs Ae Main unit when detached from the base part When locking tab is released mm 4 Fixate the base parts onto the mounting position inside the cabinet with screws when mounting dismounting to from DIN rails 5 Attach the main units to the base parts Cautions when mounting In order to aid heat dissipation 30mm of clearance 50mm recommended above and under the controllers should be provided eg ees Connecting controllers 1 Check that locking tabs are pulled down Bom released Bo e 3 EO 2 Connect controllers with each other using nl side connectors g N N z Side connector a A 3 After mounting connected controllers onto em _ i H DIN rail make sure to push up all locking 06 E i pe to sei eters tabs Controllers are fastened to DIN rail and eS e Pull down the locking tab of the to each other T Bl Si base part Hook the back of the Hide back Ol
8. efore detaching the terminal block or removing the main unit from the base part In order to aid heat dissipation do not block the top and the bottom of the equipment When mounting dismounting controllers to from DIN rails 30mm of clearance above and under the controllers should be provided Do not use the terminal screws other than those supplied with this product 2 3 For wiring to terminal blocks apply crimp terminals for M3 screw Screw size M3 x 7 with square washer Screw tightening torque 0 78 Nem 8 kgfecm To avoid noise conductor effects input signal wires should be separated from electric power lines or load lines To comply with CE marking EMC we recommend to attach ferrite core to communication cable and power cable 2 4 The alarm function does not work properly when an error occurs unless the settings are made correctly Always verify its setting before operation Cautions when Attaching to DIN rails Cautions for Wiring Error Operation Please do not wipe the equipment with organic solvents such as alcohol or benzene etc If wiping is necessary use a neutral cleaning agent Do not use mobile phones near this equipment within 50cm Otherwise a malfunction may result Malfunctions may occur if the equipment is used near a radio TV or wireless device This equipment requires approx 20 seconds before it starts to output Before installing and wiring take necessary measu
9. oblems with this equipment may lead to serious accidents install appropriate external protective circuits To prevent damage and failure of the equipment provide the rated power voltage To prevent electric shock and equipment failure do not turn the power ON until all wiring is complete Before turning the power ON confirm that clearance space has been secured to prevent shock or fire Do not touch the terminal while the machine is ON Doing so risks shock or equipment errors Never disassemble convert modify or repair this equipment Doing so risks abnormal operation shock or fire All of the wiring should be class 1 type wiring or the low voltage wires are routed separately from the hazardous voltage wires to ensure separation of circuits When using a AWG 16 cable you should use the crimp terminal that material thickness is 0 9mm or less 1 2 When installing or removing the equipment turn the power OFF Otherwise shock operational errors or failures may be caused Periodic maintenance is recommended for continuous and safe use of this equipment Some parts installed on this equipment have a limited life and or may deteriorate with age The warranty period for this unit including accessories is one year if the product is used properly VEUC 2 A Caution 2 1 For install in UL listed enclosure only Please avoid installing in the following locations Locations in which the ambient tempera
10. ode 0 8 Nem Material thickness 0 9mm or less 3 2mm cy YH Y crimp terminal 6 0mm or less 1 Enhanced communication module CC Link 123 465 67 8 9 10 PIM FIO OL Contents Module type C Advanced communication module Communication function L CC Link communication Instruction manual A Japanese B English Accessories Optional 1234567 DIN rail mounting end plate Side connecting terminal cover right amp left 1 set Front face screw terminal cover Loader connecting cable RS 232C 8 aw 2 3 4 1 Specification General Specification Power Supply DC24V 10 Power Consumption Maximum 3 2W 135mA when DC24V is applied Dimensions 30 W x 100 H x 85 D mm excluding the terminal cover and a projection Weight Approx 200 g Installation method Mounting on the wall or install in the cabinet with the DIN rail with M3 screws 10 to 50 degrees C Ambient temperature is the temperature underneath the controller Ambient temperature inside equipment or the cabinet where the controller is installed Ambient humidity System maximum modules 90 RH or less non condensing Up to max 17 modules of any Model PUMA B C CL CM V N T plus to max 16 modules of Model PUME 24V dc 100W maximum Class 2 Nonvolatile memory EEPROM backup No of updates 100 0
11. on No Station No of CC Link can be set using the Station No configuration switch Setting range is 1 to 61 Apply a fine tip flat head screwdriver to turn the Station No configuration switch 10 igh order setting et value x 10 1 ow order setting et value x 1 Setting range 1 to 61 factory set value 0 CC Link communication can not perform with the factory set value 0 Make sure to set the Station No When selected 0 or over 62 a Station No selection error will occur and L ERR LED will be ON Setting CC Link Communication speed Communication speed of CC Link can be set using the station number configuration switch on the back of the controller Apply a fine tip flat head screwdriver to turn the Station No configuration switch x CC Link communication speed setting Communication speed and maximum transmission distance when using Ver 1 10 compliant CC Link special cable eS eae ee 0 156kbps 1200m 1 625kbps 900m 2 2 5Mbps 400m 3 5Mbps 160m 4 10Mbps 100m When 5 to 9 are selected a communication speed sellection error will occur and L ERR LED will be ON Setting No of stations occupied Extended cyclic No of stations occupied Extended cyclic can be set using the dip switch SW1 to SW4 on the back of the controller No of stations occupied Extended cyclic setting Vou u uu bv od ued
12. res for electrostatic discharge ESD Part names and Functions Enhanced communication module controller Station No Configuration switch See Setting Loader communication port LED indicator input output gt terminal block See Wiring LED indicator Three color LED lamps indicate he following operational conditions LED Green Red Orange In priority order OFF Power is OFF Flash In a 0 4 second cycle 1 Modules detected by initial polling 0 PWR 2 After initial polling an inter module communication error occurs Flash In a 0 1 second cycle Initial polling ON Running ON Receiving by ON Transmitting by BUS inter module inter module communication communication ON Data linking OFF H W resetting or ERUN data linking not T performed ON Communication error CRC error Station number setting error communication speed setting error L ERR _ OFF Receiving normally T or while H W resetting Flash Setting switches during the power ON sD ON Transmitting the L _ CC Link data RD ON Receiving the m _ CC Link data Base part Mounting screw hole Module connector gt Module connector Connect modules laterally Power terminal block See Wiring Mounting screw hole See Mounting Locking tab Setting CC Link Stati
13. ture falls outside the range of 0 to 50 degree C when equipment is in use Locations in which the ambient humidity falls outside the range of 45 to 85 RH when equipment is in use Locations with rapid temperature changes leading to dew condensation Locations with corrosive gases especially sulfide gas ammonia etc or flammable gases Locations with vibration or shock directly Locations in contact with water oil chemicals steam or hot water If the equipment gets wet there is a risk of electric shock or fire so have it inspected by Fuji distributor Locations with high concentrations of atmospheric dust salt or iron particles Locations with large inductive interference resulting in static electricity magnetic fields or noise Locations in direct sunlight Locations that build up heat from radiant heat sources etc Aswitch or circuit Breaker shall be included in the building installation Please be it in close proximately to the equipment and within easy reach of the operator and mark it as the disconnecting device for the equipment Cautions when Installing 2 2 In case of mounting the temperature controllers to DIN rails remember to push up the locking tabs to fasten the controllers onto DIN rail To connect controllers first release all locking tabs Then connect controllers and push up all locking tabs Make sure that all locking tabs are fastened Never fail to turn the power OFF b
Download Pdf Manuals
Related Search
Related Contents
Pronunciation Power User Manual 7 - Gartentechnik.com IPMI: Freight Train to Hell Copyright © All rights reserved.
Failed to retrieve file