1. Production monitored Safety tested always supplied with products of uniform quality Throughout the entire production process our materials products are quality controlled by the operators Additionally a final test is carried out prior to packaging and shipping The operator carrying out the final test which includes a check of all moveable parts motors and castors issues a QA number on the product thereby confirming its quality If the product does not correspond to the quality demands of Invacare it will be discarded 5 If contrary to our expectations a problem should arise in connection with the delivered product please contact your Invacare supplier An address list is Shown on the back side at this manual Invacare reserves the right to alter product specifications without prior notice 1 3 Labels and symbols WARNING This symbol warns of dangers If the necessary measurings not are taking it can result in injury or damage to the bed NOTE This symbol inform about important information and guidelines Instruction Reference to the user manual To identify the product please look at the Product label INVACARE EC HONG AM Ostergede 3 0K 4270 Hang DEMMARK CE owners Electrical information Type nr ETUDE PLUS Lin 290v I 2 10 S0 tie ED See chapter 7 Serial no e SN Uu 2a max 70VA IT IT NIS Date of production Moli EL EA ake Type no of the bed
2. 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people 32 8 Technical specifications 8 1 Dimensions All measurements are stated in cm All angles are stated in degrees All measurements and angles are stated without tolerances Invacare reserves the right to change the stated measurements and angles A 4 sectioned 85 24 35 56 25 70 18 15 D ve u pee 33 low Hih aj 29 29 B m m p isis 165205 8 2 Transportation and storage conditions Environment Conditions Relative Atmospheric humidity pressure From 10 C 20 700 hPa To 50 C 75 1060 hPa Temperature Operating From 75 C 20 700 hPa To 40 C 75 1060 hPa Be aware that when a bed has been stored under low temperatures it must adjusted to operating conditions before use 34 8 3 Weights Etude Plus bed end with extra plate piece 6 eee ee eens 20 6 kg Etude Plus bed end without extra plate piece 1 eee eee ees 17 9 kg Mattress support standard head end 12222 xr ERES 1 1 ee 24 kg Mattress support w autoregression head end 0 cece eee eee cee eens 27 9 kg Mattress support w autoregression head end without acuator and control box 24 1 kg Mattress support foot end ee east 17 4 kg Scala Basic 2 side rail pIeeSs usd 05 42
3. e The bed is not intended for children under 2 years and psychiatric patients L N 180kg Furthermore Be aware of the limitations of use mentioned in the warnings chapter 1 4 N 4 Invacare is certified according to DS EN ISO 9001 and ISO 13485 which ensures that our customers are The estimated product life cycle is 7 years for a Etude Plus bed The bed is quipped with loose cables which have to be exchanged if damaged The control unit external power supply and motors are protected according to IPx6 When the bed is equipped with a HL80 hand control is protected according to IPx4 Remove the plug from the mains voltage before moving the bed The cable must be kept clear off the floor and the castors during transportation Sound level 45 50 dB A The adjustment area of the mattress support is 40 80 cm or alternatively 33 73 cm The angle between the lower leg section and horizontal is adjustable from 0 to 15 Certification The Etude Plus bed is marked with the CE mark in accordance with directive 93 42 EEC concerning Medical Apparatus The Etude Plus bed has been tested and approved according to EN 1970 2000 Beds provided with tilt function can not be approved according to EN 1970 2000 Mechanically the Etude Plus bed have been approved according to IEC 60601 2 52 The Etude Plus bed has been approved and marked with the T V mark The Etude Plus bed has undergone a risk analysis according to EN ISO 14971 2001 03
4. has to be respected When especially very thick mattresses or soft mattresses low density or a combination of these it is important to focus on this risk The minimum width and length of mattresses in combination with a given side rail is stated in the table 20 Mattress Mattress Mattress Mattress platform in low position Line side rail Mattress support I5 cm 5 cm 90 cm 200 cm platform in high position platform in low position cdi ix E nds PEPPEN 5 cm 5 cm 88 5 90 cm 200 cm platform in high position 4 7 Transport brackets See instructions at the last page in this User manual 21 5 Order numbers for accessories Side rail Scala Baic 2 foldable pair bosse qu an ee a ee RIS PS Ee DN NOE Re RE Ed d acces 1528930 XXXX Scala basic Plus 2 foldable Dall zus resume er ORI SQUE SERERE a DI PEN Ede SERE 1529745 XXXX Scala Medium 2 foldable Dain 3 iue re RU RR Ipae eR Da Ra equ e Va EP E rq E AER 1530436 XXXX Scala Decubi 2 foldable Dll egre jose ben EIER wees Pa eek nem v de denda agrandir onde fra nist atio P d 1530817 XXXX Britt V wooden Ball Losemds dass era ee een see EE dde SN 1538458 XXXX See ee eI bL ee ee ee ee ee ee ERE EN REIR torpe ma xt ee v fedes ire dub 1522786 XXXX litis exteridabl go 2a gt aces WII IR REESE P EI INR RERUM EE HIIS D UA dE eam MURS due d qud UR 1522787 XXXX Bed end extra plate Bed end DIE E rrrPER 1551228 XXXX Mattress support Mattress support exten
5. screws nuts etc Every two year Service should be performed after the maintenance chart See chapter 6 2 Maintenance chart 6 4 Lubrication plan We recommend lubricating the bed according to the following instructions Points of rotation in mattress support and base frame lubricate with oil 2 All of the motors tension rod lubricate with oil NS Nes 3 All motor bearings and Rastofix fitting lubricate with oil Y Lubricate with medically clean oil e g KEN WO 50 order no 813239 NB The wooden side rails gliding system must not be lubricated with oil otherwise the wooden bars will move sluggishly Remove the mains plug from the socket before cleaning 25 7 Electrical system Voltage supply 230 V x10 76 50 Hz Max current input A Voltage output 24 V max 70 VA Intermittent periodic motor operation 076 max 6 min h Protection class IPX6 Insulation class Il type B Alternating current Direct current The patient is not separated from the ground and the chassis Potential equalization The bed is not provided with a mains switch so the mains plug is the only separation from the mains 26 7 Trouble shooting the electrical system Mains indicator does not light up Mains indicator lights up but the motor is not run ning The relay in the control unit makes a clicking noise Mains indicator lights up but the motor is not run ning No relay sound is heard fro
6. 0 Fax 45 36 90 00 OI www invacare dk denmark invacare com Austria INVACARE Austria GmbH Herzog Odilostrasse 101 A 5310 Mondsee Phone 43 6232 5535 0 Fax 43 6232 5535 4 www invacare austria at info austria invacare com United Kingdom amp Ireland INVACARE Ltd Pencoed Technology Park Pencoed UK Bridgend CF35 5AQ Phone 44 656 776 200 Fax 44 656 776 201 www invacare co uk uk invacare com ireland invacare com Manufacturer INVACARE Lda Rua Estrada Velha 949 P 4465 784 Leca do Balio www invacare pt Customer Sales and Service Sweden amp Finland INVACARE AB Fagerstagatan 9 S 163 9 Spanga Phone 46 8 761 70 90 Fax 468 761 81 08 www invacare se sweden invacare com Belgium amp Luxemburg INVACARE N V Autobaan 22 B 8210 Loppem Br gge Phone 32 50 83 10 10 Fax 325083 1011 www invacare be belgium invacare com Spain INVACARE S A c Areny s n Poligon Industrial de Celra E 17460 Celra Girona Phone 34 972 49 32 00 Fax 34 972 49 32 20 www invacare es contactsp invacare com Ident no 1544173 Version 03 Date 11 2011 Norway amp Iceland INVACARE AS Grensesvingen 9 Postbox 6230 Etterstad N 0603 Oslo Phone 47 22 57 95 00 Fax 47 22 57 95 QI www invacare no norway invacare com France INVACARE Poirier S A S Route de St Roch F 37230 Fondettes Phone 33 2 47 62 64 66 Fax 33 247 42 12 24 www invacare fr contactfr invacare com Portugal INVACARE L
7. Invacare Etude Plus Bed User manual Gy C This manual must be given to the user of the product Before using this product read this manual and save for future reference Yes you can Contents s General Informiatioli 266467540 Gn ROO JE RCR UCA S Er ace Ce hee ewe USE EU E seeds 4 el Product MISC P DTITTIITTTEITTTET 4 12 Cer NCO uox exc a9 90 979 8 ELIES EREDIENS EENEN EENE 5 n3 Labels and SVEDDBOILS xo 2 1 000 ne na a 75 6 Oe Oe 429 8 ars oe a ae 6 1 4 Safety and Warnings xax x69 e Fes neben 7 LS WVarralty 5s924 929 22 999 5 419 nannte 9 Receiving tlie DeG cu oue cee detec 9909308 E99 308 9 9 9109 8119 9 EDS eee SOs we 10 2 1 Parts OF the DO s i59 aa a a Ge we er a nn are 10 2 2 Assembly of the bed 42222299 9x9 ERROR nennen n 23 WWING I 650 b 0665605456560 SU Da SOE Ee Oe SoS Os CASES ST Eee 12 2 4 Dismantling the D6Gs s05 6s du hades ERE we DR anne 13 Operating Che Ded 2 us au x xr e HER OP TUS a wore 8 8 er me aed I E oe 14 3 1 Operating of the hand control unit eee eere ees 14 3 2 Operating the braking Castors ceeeeee cece eee nn 15 3 3 Adjustment of leg section ceeeeeeeeeeeeenen nn nn 15 AJACCOSSOFIOS iu dao 56 CR IRE SHED EO ESE EOE RO de ee DEAE SS IIR CIL AUN 16 4 1 Mounting dismounting the steel side rail 16 4 2 Mounting dismounting the Line and Britt V side rails 17 4 3 Operatio
8. Symbols See chapter and 7 6 1 4 Safety and Warnings Invacare accepts no liability for any use change or assembly of the product other than as stated in this user manual Accessories not mentioned in this manual must not be used The Etude Plus bed fulfils all requirements regarding maximum distances However if the bed is used for the care of patients with a small body dimensions it must be especially noted that there is a risk of such a patient slipping through the openings between the side rails or through the opening between the side rail and the mattress support The bed must not be used by patients under 2 years of age or by patients with body size equivalent to an average 2 years old or smaller The bed in combination with side rails must not be used for persons under 45 kg or under 150 cm height Either for persons that are restless spasms or confused unless a professional risk assessment has taken place and been accepted A correctly installed safety cover on the side rails can be used When using side rails and the according safety cover it is essential to ensure correct fitting otherwise there is danger of entrapment suffocation between mattress support side rail and bed end The bed is not intended for use together with MEDICAL ELECTRICAL EQUIPMENT Make sure that there are nothing under over or near the bed that can limit the movement of the bed or the mat tress support such as furniture window frame
9. castors is provided with brakes for both lengthwise and crosswise locking The brake is foot operated 3 3 Adjustment of leg section Operate the leg section by lifting the mattress handle Up Lift the mattress handle on the leg section Down Lift the mattress handle on the leg section right up and then lower the leg section 4 Accessories When using side rails you must always make sure that the distance between the bed end and the side rail s handle upper edge is less than 6 cm or more than 32 cm A There is a risk of entrapment of fingers on assembly and operation of the side rail 4 1 Mounting dismounting the steel side rail The side rail must be mounted with the release system at the head end of the bed Mounting The fork links on the side rail must be mounted according to the instruction on the side rail Tighten the side rail with the 2 finger screws Dismounting Loosen the 2 finger screws and remove the steel side rail 4 2 Mounting dismounting the Line and Britt V side rails Warning To avoid entrapment suffocation or accidental fall accidents from the mattress support it is essential that the gliding shoes be correctly guided into the bed end rails Adjust the side rail bars by hand to ensure they are mounted correctly Safety Make sure that the straps between the rails are not damaged or loose 2 Press the locking pin at the end of the side rail with a finger 3 All three glid
10. da Rua Estrada Velha 949 P 4465 784 Leca do Balio Phone 351 225 1059 46 47 Fax 351 225 1057 39 www invacare pt portugal invacare com 3rd party certified according to EN ISO 9001 EN ISO 13485 Germany INVACARE GmbH Alemannenstrasse 0 D 88316 Isny Phone 49 75 62 7000 Fax 49 75 62 7 00 66 www invacare de kontakt invacare com Italy INVACARE Mecc San s r l Via dei Pini 62 I 36016 Thiene VI Phone 39 0445 38 00 59 Fax 39 0445 38 00 34 www invacare it italia invacare com Australia INVACARE Australia Pty Ltd Lenton Place North Rocks NSW 2151 Phone 61 2 8839 5333 Fax 61 2 8839 5353 www invacare com au sales invacare com au Netherlands INVACARE BV Celsiusstraat 46 NL 6716 BZ Ede Phone 31 318 695 757 Fax 31 318 695 758 www invacare nl nederland invacare com csede invacare com Switzerland INVACARE AG Benkenstrasse 260 CH 4108 Witterswil Phone 41 61 487 70 80 Fax 41 61 487 70 8l www invacare ch switzerland invacare com New Zealand INVACARE NZ 4 Westfield Place Mt Wellington Auckland Phone 64 9 917 3939 Fax 64 9917 3957 www invacare co nz sales invacare co nz Yes you can
11. de the head and foot end of the mattress support 3 Operating the bed 3 1 Operating of the hand control unit UP DOWN UP DOWN A y lt Sitting position Fa lt Thigh section L imd 7 Height adjustment of the bed nr d J Key for locking and unlocking the sS electrical functions Insert the key below each button to respectively lock and unlock the hand amp lt control functions HL 80 with integrated ACP function HB80 The beds can be equipped with a hand control that activate the tilt of the mattress support this hand control can be ordered from Invacare please refer to the section Order numbers for accessories A e T Medically trained persons must only operate the tilt function otherwise there is a risk of injury to the patient s E ON health 3 2 Operating the braking castors Set off from the castors might under special conditions appear at different types of absorbing floor covering i including untreated or badly treated floors In matters of doubt does Invacare recommended to place a suitable kind of protection between the castors and the floor When the bed is positioned correctly at least one castor at the head end and one castor in the foot end must be braked Braking Step on the pedal pos Releasing the brake Step on the release pedal pos 2 Do not release the brake with the fingers as there can be a risk of trapping Each of the
12. e to the frequency of the transmitter Recommended separation distance Conducted RF IEC 61000 4 6 d E WP 1 3 5 Radiated RF d 2 j p 80 MHz to 800 MHz 1 IEC 61000 4 3 J NP 800 MHz to 2 5 GHz 1 30 IEC 60601 test level Compliance level Electromagnetic environment guidance where p is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer and d is the recommended separation dis tance in metres m Field strengths from fixed RF transmitters as deter mined by an electromagnetic site survey should be less than the compliance level in each frequency range Interference may occur in the vicinity of equipment marked with the following symbol Geo NOTE At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagnetic environment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which the medical bed ETUDE PLUS is used exceeds the applicable RF compliance level ab
13. ehe 7 4 kg Biggs eperen eE E E E ob E EE 4 2 kg Mattress support extension 10 cm cece ee eee rn 3 2 kg Mattress support extension 20 cm cece cee ce e ra 5 5 kg Etude Plus standard bed complete excluding accessories 2222222 eee eeee 77 3 kg Etude Plus auto regression complete excluding accessories lll 82 7 kg 9 Waste disposal This product has been supplied from an environmentally aware manufacturer that complies with the Waste Electrical and Electronic Equipment WEEE Directive 2002 96 CE This product may contain substances that could be harmful to the environment if disposed of in places landfills that are not appropriate according to legislation The crossed out wheelie bin symbol is placed on this product to encourage you to recycle wherever possible Please be environmentally responsible and recycle this product through your recycling facility at its end of life All wooden parts must be dismantled and sent for incineration All electric parts must be dismantled and be disposed of as electric components Plastic parts must be sent for incineration or recycling Steel parts and castors must be disposed of as waste metals Waste disposal must comply with the laws and regulations pertaining waste handling in each country Transport brackets Transportsicherung Transporthaken Denmark INVACARE A S Sdr Ringvej 37 DK 2605 Br ndby Phone 45 36 90 00 0
14. ing shoes at the end of the bars are guided into the bed end rail until the lower bar has been locked thereby preventing the side rail from falling down B 4 Repeat points 2 and 3 when mounting the other end of the side rail Dismounting l Lower the side rail 2 Dismount one end at a time Lift the lower bar so that the spring pawl is visible 3 Press the spring pawl with a key or a screwdriver C 4 Hold the lower bar Lower the side rail until all three bars are free of the bed end rail 5 Repeat points 2 to 4 when dismounting the other end of the side Mounting l Mount one end at a time Lift the upper bar the release buttons must face up outwards A rail 7 4 3 Operation Line and Britt side rail The bed end may be equipped to lock the siderail at half height as well as in the top position Normally the side rail can only be Raise locked in top position Up Pull up the top wooden side rail bar until the locking pin locks with an audible click Down Lift the top wooden side rail bar and press the two locking rings together Lower the side rail Release Lower 4 4 Lifting pole Position the lifting pole in such a way that the handle extends inwards across the bed If the lifting pole is used while the handle has been turned away from the bed the bed can tip when the handle is used Mounting Remove the plug from the lifting pole tube at the head end of the bed where the lif
15. m the control unit Control unit is in order except one direction on one channel Motor is running but the spindle does not move The motor cannot lift full load Motor noise but no movement of piston rod Piston rod operate inwards and not outwards Mains not connected 2 Fuse in the control unit is blown 3 Control unit defective Motor plug not pushed fully into the control unit 2 The motor is defective 3 Motor cable is damaged 4 Control unit defective Control unit defective 2 Hand control box defective Hand control box defective 2 Control unit defective Motor damaged 27 Connect mains 2 Replace the control unit 3 Replace the control unit Push the motor plug right into control unit 2 Replace the motor 3 Replace the cable 4 Replace the control unit Replace the control 2 Replace the hand control box Replace the hand control box 2 Replace the control unit Replace the motor 7 2 Electo Magnetic Compliance EMC Guidance and manufacturer s declaration electromagnetic emission The medical bed ETUDE PLUS is intended for use in the electromagnetic environment specified below The customer or the user of the bed should assure that it is used in such an environment Emissions test Compliance Electromagnetic environment guidance BESSIMISSIONS The medical bed ETUDE PLUS uses RF energy only for its internal function CISPR 11 Group The
16. n Line and Britt side rail eee 18 4 4 Lit DO G 23 9 3 37 99 d 97873 168 978 409 sa 8 099 Oe Bark 800 93 ek en seen 19 4 5 Fitting the mattress support extension cc ec ccc ccc ccc ecccees 19 4 6 Mares snorris ttnn gud wae erneuern 20 4 1 Transport DFACKetS ehem da nennen 21 ul Order numbers for accessories cece ccc c cere rere ern 22 Cleaning and Maintenance ccc cece cece eee reer hr scene 23 Onl CICANING zen sen aaa ete ee ee Oe eee eee es 23 6 2 Maintenance chart 6 6666 666 4 5466664 SHES HERE EOS REA Ear rA Ed 9 ES Rs 24 6 3 Maintenant u 99e nn 0a rer 25 6 4 Lubrication DIAN ss sses x9 wee oh ea nen VA ed RA Ut E Y 25 Electrical YSCO 4 oi oo 44640 65 06 54 re tooo the ROR he eee sd eee 26 7 1 Trouble shooting the electrical system eee 27 7 2 Electo Magnetic Compliance EMC eere 28 Technical specifications ccc ccc ccc ccc ccc wr weer rrr tnn 33 8 1 DIMENSIONS sx 4654 e060 an einen bea ee 08 ded ap Ee se eee 33 8 2 Transportation and storage conditions eee 34 8 3 cuu rw 35 s Waste HISDOSII s ice a dac 64 co Vee PALA URP nee nr OS ee eee ae 35 Congratulations Congratulations on your choice of Invacare Etude Plus nursing bed Etude Plus is the dismantle able nursing bed from Invacare designed especially for home nursing Etude Pl
17. ove the medical bed ETUDE PLUS should be observed to verify normal operation If abnormal performance is observed additional measures may be necessary such as reorienting or relocating the medical bed ETUDE PLUS Over the frequency range 150 kHz to 80 MHz field strengths should be less than V V m 3l Recommended separation distances between portable and mobile RF communications equipment and the medical bed ETUDE PLUS The medical bed ETUDE PLUS is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled The customer or the user of the medical bed ETUDE PLUS can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment transmitters and the medical bed ETUDE PLUS as recommended below according to the maximum output power of the communications equipment Separation distance according to frequency of transmitter Rated maximum output of transmitter 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2 5 GHz For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estimated using the equation applicable to the frequency of the transmitter where P is the maximum output power rating of the transmitter in watts W according to the transmitter manufacturer NOTE I At 80 MHz and 800 MHz the separation distance for the higher frequency range applies NOTE
18. pply lines kV for input output lines kV differential mode 2 kV common mode lt 5 2 U gt 95 dip in U_ for 0 5 cycle 40 U 60 dip in U for 5 cycles 70 U 30 76 dip in U_ for 25 cycles 5 76 U 795 76 dip in U for 5 sec Floors should be wood concrete or ceramic tile If floors are covered with synthetic material the relative humidity should be at least 30 76 Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment Mains power quality should be that of a typical commercial or hospital environment If the user of the medical bed ETUDE PLUS requires continued operation during power mains interruptions it is recommended that the medical bed ETUDE PLUS be powered from an uninterruptible power supply or a battery IEC 60601 test level Compliance level Electromagnetic environment guidance Power frequency 50 60 Hz Power frequency magnetic fields should be at magnetic field 3 Alm 3 Alm levels characteristic of a typical location in a typical commercial or hospital environment IEC 61000 4 8 U_ is the a c mains voltage prior to application of the test level communications equipment should be used no closer to any part of the EQUIPMENT medical bed ETUDE PLUS including cables than the recommended separation distance calculated from the equation applicabl
19. refore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment partly AE ERSSON The medical bed ETUDE PLUS is suitable for use in all establishments including Class B domestic establishments and those directly connected to the public low voltage CISPR a partly power supply network that supplies buildings used for domestic purposes Harmonic emissions Class A IEC 61000 3 2 Voltage fluctuations flicker emissions Complies IEC 61000 3 3 28 uidance and manufacturer s declaration electromagnetic immunity The medical bed ETUDE PLUS is intended for use in the electromagnetic environment specified below The customer or the user of the bed should assure that it is used in such an environment IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 Electrostatic transient burst IEC 61000 4 4 Surge IEC 61000 4 5 Voltage dips short interruptions and voltage variations on power supply input lines IEC 61000 4 1 6 kV contact t 8 kV air 2 kV for power supply lines kV for input output lines kV differential mode 2 kV common mode 5 76 U gt 95 dip in U for 0 5 cycle 40 U 60 dip in U_ for 5 cycles 70 U 30 76 dip in U for 25 cycles 576 U 795 dip in U_ for 5 sec 6 kV contact t 8 kV air t 2 kV for power su
20. s and storage boxes Always lower the bed to the lowest position before leaving the patient in the bed unattended There is a risk of entrapment of fingers in the bed moving parts e It can be dangerous to roll over the mains cable e Do not bring mains cable into moving parts i e Disconnect the plug from the mains before moving the bed e The cables must be mounted in such a way that they are kept clear of the floor and do not block the castors We recommend to mount the mains cable on the hook for this purpose see picture 1 5 Warranty The warranty covers all material and production defects for 2 years from the date of delivery provided it can be demonstrated that such defects were present before delivery All manufacturing faults or defects must be promptly reported Invacare may repair the fault or replace the component The warranty provided by Invacare does not cover additional costs transport packaging labour sundry expenses etc are for the customer s account The warranty does not cover Damage caused during transport that is not directly reported to the forwarder at the moment of delivery Repairs performed by unauthorized centers and personnel Parts subject to normal wear Malicious damage or damaged caused by improper use of the bed 2 Receiving the bed 2 1 Parts of the bed i Check the packaging if the bed shows any signs of damage upon delivery please se the terms of delivery Follow part mu
21. shing plants or the use of water jet based cleaning equipment Please make sure the power plug is removed from the socket outlet before cleaning The bed should be washed down using a wet sponge cloth or brush Use ordinary household cleaning agents Never use acids alkalines or solvents such as acetone or cellulose thinner The hand control motors and control unit may be washed with brush and water but not with pressurized water Dry the bed after cleaning UAWN NB All plugs must be installed during washing of the bed 23 6 2 Maintenance chart Service and maintenance of the Etude Plus must only be performed by personnel who have received the neces sary instruction or training Bed Id no Visual inspection of all parts of the bed plastic deformation and or wear and tear of welded joints Control of all centres of rotation motors mattress support parts Pf Ff o All motors running without failures with regular speed and at low noise Pf fp Check the Rastofix fittings and function ee Visual inspection of all cabinets for damages Pf fp Check that mains cable and plug are intact Check the running of the cable Check all remaining cables for damages Also check the running of the cables 24 6 3 Maintenance Before use Ensure that all manual and electrical parts functions correctly and are in a secure state After 3 months Ensure that all manual and electrical parts are functioning and tighten bolts
22. sion TO cM aee v oco Yd Dind mee beans Qd ORE ore PERI baad EROR bep Edd ide 1423993 7032 Mattress support extension e 20 cM s one xau kd ox reger DEM Era dax needs ine tert iss 1423994 7032 General reine pP ae 1542093 XXXX TrSHnSDOPFE DEE atomique bes d URP TUN EES NS REC REd VM Nm dead CUERO MIA WE D PUE E 154904 XXXX Hand control with tilt THBBT suie eii nee nee ae VAS d RE IIS Pur dd up woe E 1548934 X XXX Hand control with tilt HL84 with integrated ACP function 0 ccc cece cee ee eee eee RR Rn 1548936 XXXX Backup battery and battery box s cau ce 6h un oe sn Y IeR dre Heeb eee ebd ed ce Seba p er ee 1449687 XXXX If a mattress support extension is used it is also possible to use an extended side rail XX XXXX means that colour wood type must be indicated contact sales company for further question Please only use original spare parts Spare parts lists and extra user manuals can be ordered from Invacare or homepage 22 6 Cleaning and Maintenance eo e Personnel who have received the necessary instructions or training may only perform Service and maintenance of the bed L e With normal daily use service must be carried out according to the service schedule after 2 years use and thereafter every second year e When relocating the bed service must be carried out according to the service schedule 6 1 Cleaning The bed does not tolerate cleaning in automatic wa
23. st be provided Mattress support head end 2 pcs of mattress support bracket Pair of side rails wood or steel Mattress support foot end Motor for bed end Castors Motor for head end Mattress support extension 10 or 20 cm Optional Motor for leg end 0 Pair of bed ends Hand control HB80 or HL80 oe OS ee Optional Lifting pole Transport fitting 2 2 Assembly of the bed Mattress Support SO Q9 s DI ue EM po o Place the two inserts in the head end of the mattress support The inserts must be mounted in such a way that one extends fur ther out of the side tube than the other Loosely screw in the two thumb screws Push the foot end of the mattress support onto the two inserts Tighten with two thumb screws Retighten the two thumb screws at the head end of the top frame Turn the two mattress handles of the backrest up Turn the handle of the leg section up Turn the locking ring on the bed ends to the position open Latch the mattress support to the bed ends and press firmly into position Make sure that the bed ends are in the same level It is possible to level the bed in high position A and low position B Turn the locking ring to the position lock The locking rings locks ensure that the mattress support is not ac cidentally lifts clear of the bed ends Control Box The control box is latched to the backrest motor The control box is provided with a label
24. ting pole is to be placed 2 Insert the lifting pole into the lifting pole tube and fix with the thumb screw Adjusting the height of the lifting pole handle Loosen the cord as shown in A 2 Thelifting handle can now be adjusted to the desired height 3 Press the cord together as shown in B and check that the cord is locked in the cord lock by pulling the handle The distance between the lifting pole and the mattress Minimum at 16 cm mattress 36 59 cm Maximum at 10 cm mattress 42 65 cm 4 5 Fitting the mattress support extension Disassemble the bed and remove the inserts Mount the mattress support extension on either head or foot end and reassemble the bed 19 4 6 Mattress Safety aspects regarding combination of side rails and mattresses In order to obtain the highest possible safety level when using the bed in combination with side rails it is important to respect the minimum and maximum measures for mattresses stated in the table To mitigate the possibility of the user crawling over the top of the side rail with the risk of severe injury due to e g falling a mini mum vertical distance of 22 cm between the top of the mattress and the top of the side rail are to be respected The maximum mattress height in combination with a given side rail is stated in the table To prevent head entrapment between the inside surface of the side rail and the mattress with the risk of e g suffocation a safety maximum space
25. us bed provides ease of handling combined with good functionality Please read the entire user manual before using the bed If you have any questions concerning the use or maintenance please contact us All indications of right and left are based on that a person lying on his back in the bed Please note that there may be sections in this user manual which are not relevant to your bed since this manual applies to all on the date of printing existing modules General information l l Product use e The Etude Plus bed has been developed for domestic care and features a comfortable sitting and lying position for the patient Furthermore ergonomical operation for the carer is ensured The Etude Plus bed is defined to be used according to Application environment 3 Long term care in a medical area where medical supervision is required and monitoring is provided if necessary and medical electrical equipment used in medical procedures may be provided to help maintain or improve the condition of the patient Application environment 4 Care provided in a domestic area where medical electrical equipment is used to alleviate or compensate for an injury disability or disease ee 145 k e Ifthe patient height exceeds 2 meters it is recommended to use a mattress support extension N e e The max patient weight 145 kg provided that the weight of the mattress and the accessories do not exceed 35 kg Safe working load weight max 180 kg i
26. with symbols showing where to connect the motors plugs Backrest motor Thigh section s motor Bed end motor Hand control 2 3 Wiring In order to prevent the cables from being torn apart when activating the motors it is very important to follow the instructions below Connect the cables of the bed end motors head and foot end directly to the control box 2 The plug of the thigh motor must be directed through the open ing of the supporter for the backrest motor and then be con nected to the control box 3 Connect the mains cable to the 230 V plug 4 Run the motors of the bed ends to their top position 5 Place the motor cable of the foot end on the hook at the foot end 6 Run the backrest to its top position 7 Place the head end motor cables on the 4 hooks at the head end 8 Fasten the safety clip to the control box 2 4 Dismantle the bed e Dismantle siderails and lifting pole e Bring the bed to its lowest position and adjust all mattress sup port sections to horizontal position e Disconnect the 230 V supply Roll the cable onto the hook of the head end of the bed e Disconnect all the motor plugs from the motors do not discon nect the backrest motor cable cable I e Dismantle the safety comb from the control by means of a tool e g a flat headed screwdriver e Pull out the cables of the bed end motors and leg section motor Separate the mattress support from the bed ends e Divi