G308 HMI data sheet. - Automated Electric Systems Ltd

image

Contents

1. CompactFlash card being checked Unit is writing to the CompactFlash either because it is storing FLICKERING data or because the PC connected via the USB port has locked the drive FLASHING SLOWLY GREEN BOTTOM FLASHING A tag is in an alarm state STEADY Valid configuration is loaded and there are no alarms present 1 The operator interface is shipped without a configuration After downloading a configuration if the light remains in the flashing state continuously try cycling power If the LED still continues to flash try downloading a configuration again 2 Do not turn off power to the unit while this light is flickering The unit writes data in two minute intervals Later Microsoft operating systems will not lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson User Manual Incorrectly formatted CompactFlash card present KEYPAD The G308 keypad consists of seven keys for on screen menus TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell in sensed The touchscreen is fully functional as soon as the operator interface is initialized and can be operated with gloved hands TROUBLESHOOTING YOUR G308 If for any reason you have trouble oper
2. it can be purchased on a CD see Ordering Information for part number The latest version of the software is always available from the website and updating your copy is free DISPLAY This operator interface uses a liquid crystal display LCD for displaying text and graphics The backlight can be dimmed for low light conditions Display backlights have a limited lifetime Backlight lifetime is based upon the amount of time the display is turned on at full intensity Turning the backlight off when the display is not in use can extend the lifetime of your backlight This can be accomplished through the Crimson software when configuring your unit BACKLI GHT REPLACEMENT CCFL Backlight The G308A backlight is not field replaceable for hazardous location applications Unit must be returned to Red Lion Controls for repair The backlight assembly for the G308A only is field replaceable in non hazardous locations only Refer to the instructions included in the appropriate backlight replacement kit LED Backlight The backlight for the G308C is not field replaceable The unit must be returned to Red LionControls for repair FRONT PANEL LEDS There are three front panel LEDs Shown below is the default status of the LEDs LED INDICATION RED TOP LABELED PWR STEADY Unit is powered and running an application YELLOW MIDDLE OFF No CompactFlash card is present STEADY FLASHING RAPIDLY Valid CompactFlash card present
3. NON VOLATILE MEMORY 32MBYTE FLASH COMPACTFLASH SOCKET TO INCREASE MEMORY CAPACITY 7 5 OR 8 4 INCH TFT 32K VGA 640X480 PIXEL LCD 7 BUTTON KEYPAD FOR ON SCREEN MENUS THREE FRONT PANEL LEDS POWER UNIT FROM 24VDC 420 SUPPLY RESISTIVE ANALOG TOUCHSCREEN CONTENTS OF PACKAGE G308 Operator Interface Panel Gasket This hardware bulletin Template for panel cutout Hardware packet for mounting unit into panel Terminal block for connecting power ORDERING INFORMATION 7 5 TFT Display Operator Interface indoor No USB Host nonleolaled comms i 8 4 TFT Display Operator Interface indoor USB Host Isolated Comms 8 4 TFT Display Operator Interface indoor Dual Ethernet USB Host Isolated Comms G3CF G3CF CBL USB Cable CBLUSBOO Communications Cables 1 DIN Rail Mountable Adapter Products 4 Replacement Battery 5 BNL20000 G308A Backlight Replacement G3BRO8A0 G3FILM Protective Films G3FILM08 1 Contact your Red Lion distributor or visit our website for complete selection 2 Use this part number to purchase Crimson on CD with a printed manual USB cable and RS 232 cable Otherwise download for free from www redlion net 3 Antenna G3QANTO0 is NOT included with the card Must be purchased separately if needed 4 Red Lion offers RJ modular jack adapters Refer to the DR literature for complete details 5 Battery type is lithium coin type CR2025 6 Industrial grade two million write cycles
4. Pollution Degree 2 12 MOUNTING REQUIREMENTS Maximum panel thickness is 0 25 6 3 mm For NEMA 4X IP66 sealing a steel panel with a minimum thickness of 0 125 3 17 mm is recommended Maximum Mounting Stud Torque 17 inch pounds 1 92 N m 13 WEIGHT 4 20 Ibs 1 91 Kg G308C1 G308A2 2 a 206 69 zora Fo 972 222 a 20 NSTALLING AND POWERING THE G308 MOUNTING INSTRUCTIONS This operator interface is designed for through panel mounting A panel cut out diagram and a template are provided Care should be taken to remove any loose material from the mounting cut out to prevent that material from falling into the operator interface during installation A gasket is provided to enable sealing to NEMA 4X IP66 specification Install the 14 kep nuts provided and tighten evenly for uniform gasket compression Note Tightening the kep nuts beyond a maximum of 17 inch pounds 1 92 N m may cause damage to the front panel 9 75 247 7 9 115 231 5 3 25 82 6 la 10X 188 4 8 a po po a 7 60 193 h 6 98 177 3 a a All tolerances 0 010 0 25 mm ALL NONINCENDIVE CIRCUITS MUST BE WIRED USING DIVISION 2 WIRING METHODS AS SPECIFIED IN THE NATIONAL ELECTRICAL CODE NFPA 70 FOR INSTALLATION WITHIN THE UNITED STATES OR AS SPECIFIED IN THE CANADIA
5. N ELECTRICAL CODE FOR INSTALLATION IN CANADA CONNECTING TO EARTH GROUND The protective conductor terminal is bonded to conductive UN parts of the equipment for safety purposes and must be connected to an external protective earthing system Each G308 has a chassis ground terminal on the back of the unit Your unit should be connected to earth ground protective earth The chassis ground is not connected to signal common of the unit Maintaining isolation between earth ground and signal common is not required to operate your unit But other equipment connected to this unit may require isolation between signal common and earth ground To maintain isolation between signal common and earth ground care must be taken when connections are made to the unit For example a power supply with isolation between its signal common and earth ground must be used Also plugging in a USB cable may connect signal common and earth ground 1 USB s shield may be connected to earth ground at the host USB s shield in turn may also be connected to signal common POWER SUPPLY REQUIREMENTS The G308C1 requires a 24 VDC power supply rated at 13 W and the G308A2 requires a 24 VDC power supply rated at 27 W Your unit may draw considerably less the rated power depending upon the options being used As additional features are used your unit will draw increasing amounts of power Items that could cause increases in current are additional communications option
6. NCENTRATIONS INSTALLING AN OPTION CARD WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON HAZARDOUS Each option card comes with a cable for communications and three screws for attaching the option card to the G3 s main board To install the option card remove all power and I O communications cables from the unit and remove the rear cover Connect the cable from the option card to the connector on the main board Be sure both ends of the cable are firmly seated into their appropriate connector housings Use the three screws provided to mount the option card to the main board as shown in Figure 1 Carefully replace the rear cover by reversing the instructions for removing the rear cover TYPICAL EXPANSION CARD INSTALLATION Figure 1 COMMUNICATING WITH THE G308 CONFI GURI NG A G308 The G308 is configured using Crimson software Crimson is available as a free download from Red Lion s website or it can be purchased on CD Updates to Crimson for new features and drivers are posted on the website as they become available By configuring the G308 using the latest version of Crimson you are assured that your unit has the most up to date feature set Crimson software can configure the G308 through the RS232 PGM port USB port or CompactFlash The USB port is connected using a standard USB cable with a Type B connector The driver needed to use the USB
7. S port Although only one of these ports can be used for programming both ports can be used for communications with a PLC The RS232 PGM port can be used for either master or slave protocols with any G308 configuration Examples of RS232 communications could involve another Red Lion product or a PC By using a cable with RJ12 ends on it and a twist in the cable RS232 communications with another G3 product or the Modular Controller can be established Red Lion part numbers for cables with a twist in them are CBLPROGO CBLRLCO1 or CBLRC02 1 CBLPROGO can also be used to communicate with either a PC or an ICMS 2 DB9 adapter not included 1 foot long 3 DB9 adapter not included 10 feet long G3 RS232 to a PC Connections G3 RJ12 O MOINI oO a AJOJN CONNECTING A G308 OPERATOR ICM5 G3 to Modular Controller CBLRLCO05 Connections Modular Controller 1 4 4 1 2 3 NTERFACE TO AN ICM5 i U 0 0 o00000 VVVVV VT CBLPROGO ICM5 DIP Switch Settings z z O O p jerrr ppe welt tls KNOY HONODS ANOYHOR ogggozguuz BgguuuL DH485 COMMUNI CATIONS SSSaeS3E5 g 88 z z z z The G308 s RS422 485 COMMS port can also be used for Allen Bradley 33388 5 7 662 8 mapp DH485 communications BBE pe RANA 258 09 5555 x Application Dependent naa Co Pe WARNING DO NOT use a standard DH485 cabl
8. SMART Modular Technologies model SG9CF UL Listed Directory Category NWGQ SPECI FI CATIONS 1 POWER REQUIREMENTS G308C1 24 VDC 20 13 W maximum G308A2 24 VDC 20 27 W maximum Must use NEC Class 2 or Limited Power source LPS rated power supply Power connection via removable three position terminal block Note 1 The G308 s circuit common is not connected to the enclosure of the unit See Connecting to Earth Ground in the section Installing and Powering the G308 2 BATTERY Lithium coin cell CR2025 Typical lifetime of 10 years 3 LCD MODULE DISPLAYS Lifetime at room temperature Refer to Display in the Software Unit Operation section 4 7 KEY KEYPAD for on screen menus 5 TOUCHSCREEN Resistive analog 6 MEMORY On Board User Memory 32 Mbyte of onboard non volatile Flash memory Memory Card CompactFlash Type II slot for Type I and Type IL CompactFlash cards 7 COMMUNICATIONS USB Port Adheres to USB 2 0 specification full speed only via Type B connection WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION USB Host Ports Comply with Universal Serial Bus Specification Rev 2 0 Support data transfers at full speed Hardware over current protected 0 5 A max per port Serial Ports Serial ports on the G308A are individuall
9. al communications card CompactFlash card and other features programmed through Crimson In any case it is very important that the power supply is mounted correctly if the unit is to operate reliably Please take care to observe the following points The power supply must be mounted close to the unit with usually not more than 6 feet 1 8 m of cable between the supply and the operator interface Ideally the shortest length possible should be used The wire used to connect the operator interface s power supply should be at least 22 gage wire If a longer cable run is used a heavier gage wire should be used The routing of the cable should be kept away from large contactors inverters and other devices which may generate significant electrical noise A power supply with an NEC Class 2 or Limited Power Source LPS and SELV rating is to be used This type of power supply provides isolation to accessible circuits from hazardous voltage levels generated by a mains power supply due to single faults SELV is an acronym for safety extra low voltage Safety extra low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT WHILE THE CIRCUIT IS LIVE OR UNLESS THE AREA IS KNOWN TO BE FREE OF IGNITABLE CO
10. andards Type 4X Indoor Enclosure rating Face only UL50 IECEE CB Scheme Test Report E179259 A 1 CB 3 Issued by Underwriters Laboratories Inc IEC 61010 1 EN 61010 1 Safety requirements for electrical equipment for measurement control and laboratory use Part 1 IP66 Enclosure rating Face only IEC 529 ELECTROMAGNETIC COMPATIBILITY Emissions and Immunity to EN 61326 2006 Electrical Equipment for Measurement Control and Laboratory use Immunity to Industrial Locations Electrostatic discharge EN 61000 4 2 Criterion A 4 kV contact discharge 8 kV air discharge Criterion A 10 V m 80 MHz to 1 GHz 3 V m 1 4 GHz to 2 GHz 1 V m 2 GHz to 2 7 GHz EN 61000 4 4 Criterion B Electromagnetic RF fields EN 61000 4 3 Fast transients burst power 2kV T O signal 1kV Surge EN 61000 4 5 Criterion B power 1kVLtoL 2kVLtoG signal 1 kV RF conducted interference EN 61000 4 6 Criterion A 3 Vrms Power freq magnetic field EN 61000 4 8 Criterion A 30 A m Emissions Emissions EN 55011 Class A Notes 1 Criterion A Normal operation within specified limits 2 Criterion B Temporary loss of performance from which the unit self recovers 10 CONNECTIONS Compression cage clamp terminal block Wire Gage 12 30 AWG copper wire Torque 5 7 inch pounds 56 79 N cm 11 CONSTRUCTION Steel rear metal enclosure with NEMA 4X IP66 aluminum front plate for indoor use only when correctly fitted with the gasket provided Installation Category II
11. ating connecting or simply have questions concerning your new G308 contact Red Lion s technical support For contact information refer to the back page of this bulletin for phone and fax numbers EMAIL techsupport redlion net Web Site http www redlion net BATTERY amp TIME KEEPING WARNING EXPLOSION HAZARD THE AREA MUST BE KNOWN TO BE NON HAZARDOUS BEFORE SERVICING REPLACING THE UNIT AND BEFORE INSTALLING OR REMOVING I O WIRING AND BATTERY WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN DISCONNECTED AND THE AREA IS KNOWN TO BE NON HAZARDOUS A battery is used to keep time when the unit is without power Typical accuracy of the G308 time keeping is less than one minute per month drift The battery of a G308 unit does not affect the unit s memory all configurations and data is stored in non volatile memory CAUTION RISK OF ELECTRIC SHOCK The inverter board of the G308A supplies the high voltage to operate the backlight Touching the inverter board may result in injury to personnel CAUTION The circuit board contains static sensitive components Before handling the operator interface without the rear cover attached discharge static charges from your body by touching a grounded bare metal object Ideally handle the operator interface at a static controlled clean workstation Also do not touch the surface areas of the circuit board Dirt oil or other contaminants may adver
12. ctions that appear in the manual or on equipment must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it If equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired Do not use the controller to directly command motors valves or other actuators not equipped with safeguards To do so can be potentially harmful to persons or equipment in the event of a fault to the controller The protective conductor terminal is bonded to conductive UN amp parts of the equipment for safety purposes and must be connected to an external protective earthing system COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS DIVISION 2 ZN CAUTION Risk Of Danger Read complete instructions prior to installation and operation of the unit WARNING EXPLOSION HAZARD SUBSTITUTION OF A CAUTION Risk of electric shock CompactFlash is a registered trademark of CompactFlash Association CONFIGURED USING CRIMSON SOFTWARE VERSION 2 0 OR LATER UPTO 5 RS 232 422 485 COMMUNICATIONS PORTS 2 RS 232 AND 1 RS 422 485 ON BOARD 1 RS 232 AND 1 RS 422 485 ON OPTIONAL COMMUNICATIONS CARD 10 BASE T 100 BASE TX ETHERNET PORT TO NETWORK UNITS AND HOST WEB PAGES 22 ETHERNET PORT OPTIONAL G308A2 ONLY USB PORT TO DOWNLOAD THE UNIT S CONFIGURATION FROM A PC OR FOR DATA TRANSFERS TO A PC UNIT S CONFIGURATION IS STORED IN
13. e to connect this port to Allen 36 Bradley equipment A cable and wiring diagram are available from Red Lion Ei G3 to AB SLC 500 CBLAB003 RS422 485 COMMS PORT The G308 has one RS422 485 port The G308A port is isolated while the RIS RLG G308C port is not isolated This port can be configured to act as either RS422 or RS485 RS422 485 4 WIRE RS485 2 WIRE CONNEC TIONS CONNECTIONS COMM TxEN SHIELD COMM 24V TXEN OC POWER SUPPLY ISOLATION BLOCK DIAGRAM G308A2 ONLY devices Refer to www redlion net for additional information TxEN OC GND POWER USB DEVICE NOS ia M SUPPLY PROGRAMMING ISOLATED ISOLATED l RS485 RS282 Note All Red Lion devices connect A to A and B to B except for Paradigm PORTA PORT A HOST A PGM PORT 1 Lv _ J Examples of RS485 2 Wire Connections G3 to Red Lion RJ11 CBLRLCOO DLC IAMS ITMS PAXCDC4C HOST B RS232 PORT B Z a Connections G3 RJ45 RLC RJ11 ISOLATED ISOLATED AUXILIARY ETHERNET Y ETHERNET Y L ome Een L SOFTWARE UNIT OPERATION CRIMSON SOFTWARE Crimson software is available as a free download from Red Lion s website or
14. ion Controls India 54 Vishvas Tenement GST Road New Ranip Ahmedabad 382480 Gujarat India Tel 91 987 954 0503 Fax 91 79 275 31 350 Red Lion Controls China Unit 101 XinAn Plaza Building 13 No 99 Tianzhou Road ShangHai P R China 200223 Tel 86 21 6113 3688 Fax 86 21 6113 3683
15. port will be installed with Crimson If this driver has not been installed it can be downloaded from the website The RS232 PGM port uses a programming cable made by Red Lion to connect to the DB9 COM port of your computer If you choose to make your own cable use the G308 Port Pin Out Diagram for wiring information The CompactFlash can be used to program a G3 by placing a configuration file and firmware on the CompactFlash card The card is then inserted into the target G3 and powered Refer to the Crimson literature for more information on the proper names and locations of the files CABLES AND DRI VERS Red Lion has a wide range of cables and drivers for use with many different communication types A list of these drivers and cables along with pin outs is available from Red Lion s website New cables and drivers are added on a regular basis If making your own cable refer to the G308 Port Pin Outs for wiring information ACCESSI NG THE COMPACTFLASH CARD VIA USB DEVI CE PORT WARNING DO NOT CONNECT OR DISCONNECT CABLES WHILE POWER IS APPLIED UNLESS AREA IS KNOWN TO BE NON HAZARDOUS USB PORT IS FOR SYSTEM SET UP AND DIAGNOSTICS AND IS NOT INTENDED FOR PERMANENT CONNECTION In order to access data from the CompactFlash card via the USB device port a driver must be installed on your computer This driver is installed with Crimson and is located in the folder C Program Files Red Lion Controls Crimson 2 0 Device af
16. red ipn Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net Bulletin No G308C C Drawing No LP0808 Released 05 10 MODEL G308C1 A2 8 COLOR TOUCHSCREEN c UL US LISTED 3RSD PROCESS CONTROL EQUIPMENT FOR USE IN HAZARDOUS LOCATIONS Class I Division 2 Groups A B C and D C US LISTED 43NH PROCESS CONTROL EQUIPMENT GENERAL DESCRI PTI ON The G308 Operator Interface Terminal combines unique capabilities normally expected from high end units with a very affordable price It is built around a high performance core with integrated functionality This core allows the G308 to perform many of the normal features of the Paradigm range of Operator Interfaces while improving and adding new features The G308 is able to communicate with many different types of hardware using high speed RS232 422 485 communications ports and Ethernet 10 Base T 100 Base TX communications In addition the G308 features USB for fast downloads of configuration files and access to trending and data logging A CompactFlash socket is provided so that Flash cards can be used to collect your trending and data logging information as well as to store larger configuration files In addition to accessing and controlling of external resources the G308 allows a user to easily view and enter information Users can enter data through the touchscreen or front panel 7 button keypad SAFETY SUMMARY All safety related regulations local codes and instru
17. sely affect circuit operation To change the battery of a G308 remove power cabling and then the rear cover of the unit To remove the cover remove the five screws designated by the arrows on the rear of the unit Then by lifting the top side hinge the cover thus providing clearance for the connectors on the bottom side of the PCB as shown in the illustration below Install in the reverse manner Remove the old battery from the holder and replace with the new battery Replace the rear cover cables and re apply power Using Crimson or the unit s keypad enter the correct time and date Please note that the old battery must be disposed of in a manner that complies with your local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the G308 is a lithium type CR2025 G308C1 BATTERY G308A2 OPTIONAL FEATURES AND ACCESSORIES OPTIONAL COMMUNI CATION CARD Red Lion offers optional communication cards for fieldbus communications These communication cards will allow your G308 to communicate with many of the popular fieldbus protocols Red Lion is also offering a communications card for additional RS232 and RS422 485 communications Visit Red Lion s website for information and availability of these cards COMPACTFLASH SOCKET CompactFlash socket is a Type II socket that can accept ei
18. ter Crimson is installed This may have already been accomplished if your G308 was configured using the USB port Once the driver is installed connect the G308 to your PC with a USB cable and follow the Mounting the CompactFlash instructions found in the Crimson user manual G308 PORT PIN OUTS 3 ee Sf g ZZ z z z amp 3 2t zz amp amp ss amp SS Ss aZztagem V 2 2 fo lefe lefe SRORBESE LESSES KESSES e e B a a a a RS485 RS232 COMMS COMMS PROTECTIVE PORT PORT EARTH GROUND a RS232 PGM PORT Cc 123 4 USB HOST G308A only 1 1 i z x Qa 932 On 2 gt a es ETHERNET AUXILIARY USB NIC ETHERNET TYPE B OPTIONAL POWER CONNECTOR ETHERNET COMMUNI CATI ONS Ethernet communications can be established at either 10 BASE T or 100 BASE TX The G308 unit s RJ45 jack is wired as a NIC Network Interface Card For example when wiring to a hub or switch use a straight through cable but when connecting to another NIC use a crossover cable The Ethernet connector contains two LEDs A yellow LED in the upper right and a bi color green amber LED in the upper left The LEDs represent the following statuses The Crimson manual contains additional information on Ethernet communications RS232 PORTS The G308 has two RS232 ports The G308A ports are individually isolated while the G308C ports are not isolated There is the PGM port and the COMM
19. ther Type I or II cards Use cards with a minimum of 4 Mbytes and a maximum of 2 Gbytes with the G308 s CompactFlash socket Cards are available at most computer and office supply retailers CompactFlash can be used for configuration transfers larger configurations data logging and trending CUSTOM LOGO Each G3 operator interface has an embossed area containing the Red Lion logo Red Lion can provide custom logos to apply to this area Contact your distributor for additional information and pricing vg J N p 51013 Note Do not remove or insert SNe the CompactFlash card while md 7 lied Refer to power is applied Front Panel LEDs CompactFlash FRONT OVERLAY Insert Face Up t 1 65 42 i Information stored on a CompactFlash card by a G308 can be read by a card reader attached to a PC This information is stored in IBM Windows PC compatible FAT 16 file format NOTE For reliable operation of this and other Red Lion products one of the following brands of CompactFlash card must be used SMART Modular Silicon Systems SimpleTech SanDisk Not all of the above manufacturers offer CompactFlash cards recognized to UL standards which may be required for your application LIMITED WARRANTY The Company warrants the products it manufactures against defects in materials and workmanship for a period limited to two years from the date of shipment provided the prod
20. ucts have been stored handled installed and used under proper conditions The Company s liability under this limited warranty shall extend only to the repair or replacement of a defective product at The Company s option The Company disclaims all liability for any affirmation promise or representation with respect to the products The customer agrees to hold Red Lion Controls harmless from defend and indemnify RLC against damages claims and expenses arising out of subsequent sales of RLC products or products containing components manufactured by RLC and based upon personal injuries deaths property damage lost profits and other matters which Buyer its employees or sub contractors are or may be to any extent liable including without limitation penalties imposed by the Consumer Product Safety Act P L 92 573 and liability imposed upon any person pursuant to the Magnuson Moss Warranty Act P L 93 637 as now in effect or as amended hereafter No warranties expressed or implied are created with respect to The Company s products except those expressly contained herein The Customer acknowledges the disclaimers and limitations contained herein and relies on no other warranties or affirmations Red Lion Controls Headquarters 20 Willow Springs Circle York PA 17406 Tel 1 717 767 6511 Fax 1 717 764 0839 Red Lion Controls Europe Printerweg 10 NL 3821 AD Amersfoort Tel 31 0 334 723 225 Fax 31 0 334 893 793 Red L
21. y isolated Ports on the G308C are not isolated Format and Baud Rates for each port are individually software programmable up to 115 200 baud PGM Port RS232 port via RJ12 COMMS Ports RS422 485 port via RJ45 and RS232 port via RJ12 DH485 TXEN Transmit enable open collector Voy 15 VDC Vor 0 5 V 25 mA max Note For additional information on the communications or signal common and connections to earth ground please see the Connecting to Earth Ground in the section Installing and Powering the G308 Ethernet Ports 10 BASE T 100 BASE TX RJ45 jack is wired as a NIC Network Interface Card The jack shield is electrically connected to Earth ground A secondary ethernet port with its own Mac ID is available as an option on the G308A2 only 8 ENVIRONMENTAL CONDITIONS Operating Temperature Range 0 to 50 C DIMENSIONS In inches mm 10 32 262 Storage Temperature Range 20 to 70 C Operating and Storage Humidity 80 maximum relative humidity non condensing from 0 to 50 C Vibration according to IEC 68 2 6 Operational 5 to 150 Hz in X Y Z direction for 1 5 hours 2 g Shock according to IEC 68 2 27 Operational 35 g 11 msec in 3 directions 9 CERTIFICATIONS AND COMPLIANCES SAFETY UL Listed File E245515 UL61010 1 ANSI ISA 12 12 01 2007 CAN CSA 22 2 No 61010 1 CSA 22 2 No 213 and File E179259 UL61010 1 CSA 22 2 No 61010 1 LISTED by Und Lab Inc to U S and Canadian safety st