MELSECNET/H Interface Board User`s Manual (Hardware)

image

Contents

1. Manual m Japanese readme txt The following explains the files in the Japanese folder L English readme txt The following explains the files in the English folder 8 2 Operating the manual The following screen is used to browse any operating manual Adobe Acrobat sh080128a pdf ol x E File Edit Document Tools View Window Help la x NSBASIB N gt gt DONAA ef rc E _ 14 TROUBLESHOOTING _ APPENDIX Bookmark section EEEE C SAFETY PRECAUTIONS L REVISIONS QO Operating Instructions L INTRODUCTION L CONTENTS About Manuals How to Use This Manual _ About the Generic Terms Meaning and Contents oft Hm OVERVIEW 2 SYSTEM CONFIGURATI L 3 SPECIFICATIONS 7 4 FUNCTION L 5 PROCEDURE AND SET L 6 PARAMETER SETTINGS _ 7 INSTALLING AND UNINE L 8 UTILITY OPERATIONS C 9 ACCESSIBLE DEVICES 10 MELSEC DATA LINK LI 11 PROGRAMMING 12 APPLICATION FUNCTI L 13 ERROR CODE L WARRANTY 3 1 OVERVIEW 1 OVERVIEW 1 1 Overview MELSEC The MELSECNET H is a network system which is used to connect multiple sequencer modules and personal computers and is equipped with functions and performance realized in the MELSECNET 10 for general control of a production line In the MELSECNET H there is a network system which includes an optical loop system communication rates 10 Mbps 25 Mbps and a coaxial bus syst
2. The methods of installing the software package and the registered icons are explained in this section Refer to the MELSECNET H Interface Board User s Manual For SWODNC MNETH B for details on uninstalling the software and on installing by copying onto an FD 7 1 Installation procedures Refer to the MELSECNET H Interface Board User s Manual For SWODNC MNETH B for detailed installation procedures 1 A multi processor compatible personal computer cannot be used as the drivers are not compatible Refer to the MELSECNET H Interface Board User s Manual For SWODNC MNETH B for details on the working environment 2 Log on as the user who has the Administrator attributes when any of the following OSs is used Microsoft Windows NT Workstation Operating System Version 4 0 Microsoft Windows 2000 Professional Operating System Microsoft Windows XP Professional Operating System 3 Make sure to close other applications running on Windows including resident software such as antivirus software before installation 4 Remove all applications that are included in the Start up menu then restart PC before installing 5 When the installation fails to complete successfully and if software packages can be uninstalled execute uninstall 6 If you want to reinstall the software package turn off the personal computer after uninstalling the software package them turn the personal computer back on and reinstall the software
3. MITSUBISHI MELSECNET H Interface Board User s Manual Hardware Q80BD J71LP21GE Thank you for buying the Mitsubishi general purpose programmable logic controller MELSEC Series Prior to use please read both this manual and detailed manual thoroughly and familiarize yourself with the product MODEL B80 LP21GE U HW E MODEL CODE 13JR38 IB NA 0800188 G 0706 MEE 2001 MITSUBISHI ELECTRIC CORPORATION SAFETY PRECAUTIONS Always read these instructions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly Precautionary notes in this manual cover only the installation of this product For safety precautions on the PLC system refer to the CPU User s Manual In this manual the safety instructions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause hazardous DANGER conditions resulting in death or severe injury AcauTion l NCAUTION Indicates that incorrect handling may cause hazardous conditions resulting in medium or slight personal injury or physical damage Note that the Z CAUTION level may lead to a serious consequence according to the circumstances Always follow the instructions of both levels because they are important to personal safety Please save this manual to make it accessible w
4. Failure to do so may cause failure or malfunction of the MELSECNET H board Handle the MELSECNET H board in a location where there is no static electricity Static electricity could result in failure or malfunctioning The MELSECNET H board is packed in a bag for preventing static electricity Always place the MELSECNET H board in this bag when storing or transporting Otherwise failure or malfunctioning may result Take care that foreign objects such as chips or wiring debris do not get into the PC This could result in fire breakdowns or malfunctioning Do not dismantle or rebuild the MELSECNET H board This will result in failure malfunctioning injury or fire Be sure to shut off all phases of the external power supply used by the system before installing or removing the MELSECNET H board If power is not turned off there is a risk of electric shock or damage to the product When disposing of the product handle it as an industrial waste Do not drop the MELSECNET H board or subject it to strong impact This will result in failure or malfunctioning of the board 3 2 Installation environment See the instruction manual accompanying the PC unit regarding installation of the PC unit in which the MELSECNET H board is mounted CAUTION Always ground the PC unit using grounding type D Class 3 grounding Otherwise there is the risk of malfunctioning 4 Names of Each Part The names of each MELSEC
5. not cause excessive electromagnetic interference emissions and are not unduly affected by electromagnetic interference immunity The applicable products are requested to meet these requirements The sections 5 1 1 through 5 1 5 summarize the precautions on conformance to the EMC Directive of the machinery constructed using the MELSECNET H Board The details of these precautions has been prepared based on the control requirements and the applicable standards However we will not assure that the overall machinery manufactured according to these details conforms to the above mentioned directives The method of conformance to the EMC Directive and the judgment on whether or not the machinery conforms to the EMC Directive must be determined finally by the manufacturer of the machinery 5 1 1 Standards applicable to the EMC Directive The standards applicable to the EMC Directive are listed below All test items are carried out with the product mounted in a CE mark compliant personal computer 30M 230MHz QP 30dB u V m EN55011 Electromagnetic 30 m in measurement range 1 Radiated noise odara measured 230M 1000MHz QP 37 dB u V m EN50081 2 P 30 m in measurement range 1995 Electromagnetic 150k 500kHz QP 79 dB emissions from the Mean 66 dB 1 Conducted noise product to the power 500k 30MHz QP 73 dB line is measured Mean 60 dB Immunity test in which static electricity is applied to the cabinet of the equipment Immunity
6. package 13 Is the personal computer power ON Install SWODNC MNETH B utility Mount the MELSECNET H board onto the personal computer Turn OFF the personal computer power j Mount the MELSECNET H board onto the personal computer Turn the personal computer power ON i Install SWODNC MNETH B driver Turn the personal computer power ON Install SWODNC MNETH B driver Install SWODNC MNETH B utility 1 The driver does not need to be installed Completed when using Microsoft Windows NT Workstation Operating System Version 4 0 as the operating system 7 2 Icons to be registered Installing the software packages will register the icons shown below The icons shown below are registered in Start Program MELSEC When Microsoft Windows XP Professional Operating System is used the icons are registered to Start All Programs MELSEC Utility name Details MELSECNET H Utility The MNETH Utility starts when this icon is clicked 1 Error Viewer gt The Error Viewer opens when this icon is clicked Device Monitor Utility The Device Monitor Utility starts when this icon is clicked MELSEC Communication The Communication function HELP Function opens when this icon is clicked HELP 1 This utility is compatible only with the Microsoft Windows 95 Operating System and Microsoft Windows 98 Opera
7. test in which Power line 2kV burst noise is applied Digital I O 24V or higher 1kV to the power line and __ Digital I O 24V or less gt 250V signal lines Analog I O signal lines gt 250V EN61000 4 3 Immunity test in which Radiated field _ field is irradiated to the Aner arin eestor AM modulation _ product i EN61000 4 12 Immunity test in which Damped a damped oscillatory Power line 1kV oscillatory wave wave is superimposed Digital I O 24V or higher 1kV immunity on the power line 1 QP Quasi peak value Mean Average value 8 EN61000 4 2 Electrostatic 15kV Aerial discharge immunity EN61000 4 4 Fast transient EN61131 2 burst noise 1996 5 1 2 Installing into the control panel Installing this module into the control panel is effective not only for ensuring safety but also for shielding noise generated from the personal computer by the control panel 1 Control cabinet a Use a conductive control cabinet b When attaching the control cabinet s top plate or base plate mask painting and weld so that good surface contact can be made between the cabinet and plate c To ensure good electrical contact with the control cabinet mask the paint on the installation bolts of the inner plate in the control cabinet so that contact between surfaces can be ensured over the widest possible area d Earth the control cabinet with a thick wire so that a low impedance connection to ground can
8. C Chapter 3 Chapter 5 Dec 2002 IB NA 0800188 D SAFETY PRECAUTIONS Section 7 1 Section 7 2 Section 8 1 Chapter 9 Mar 2004 IB NA 0800188 E Chapter 4 Chapter 5 Chapter 9 Dec 2004 IB NA 0800188 F Chapter 2 was changed to Chapter 5 Chapter 3 to 5 was changed to Chapter 2 to 4 respectively Correction Chapter 2 Chapter 4 Jun 2007 IB NA 0800188 G Chapter 6 This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent licenses Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents noted in this manual 2001 MITSUBISHI ELECTRIC CORPORATION A 3 CONTENTS fh SOURIS orema tt as neces tt eat see dosent taste a bas kt aaa dead aa a 1 2 Performance Specifications east te accra vters at smn ans na rat pen acer areal sms aac tne veal us cs 2 sis CUINNG aoee E a AEE E A AE 3 3 1 Precautions when MaNndlinG seviecsesatiecade ds ceaiutessetorenlaavebtvtdescDsourseuvertaden doses 3 3 2 Installation GAVIFONMOM icccsiicccsssstxsccessrencsaurecsesssnieesavecsoodereuansseseesiadeda wane 4 4 Names Or Each Parterre anaro a esc a A acti ee eee 5 5 EMG Die Cly Gc caesn ce sce Ee oes he ek I Ik E A Zola 8 5 1 Requirements for conformance to EMC Directive cccccsceeeeeeeeeeeees 8 5 1 1 Standards applicable to the EMC Directive cccc
9. NET H board part are explained in this section Number Display LED L RUN ERR AD OO Details This indicates the MELSECNET H board operation status The LED lighting status include the normal mode and error mode 1 Normal mode If a communication error etc occurs in the normal mode judge the error by reading the status of the LED on the MELSECNET H Utility s Board Information screen Refer to the MELSECNET H Interface Board User s Manual For SWODNC MNETH B for details on the Board Information LED statuses name OFF A WDT error has occurred or the board is being reset RUN The board is operating ON normally Sas error has not L ERR A communication error has ON occurred Data has not been received SD gt Data is being transmitted Data has not been received Data is being transmitted Number Display LED L RUN ERR O O Optical fiber cable connection connector Details 2 Error mode When the RUN LED is flickering the LED display will change to the error mode If an error occurs in the error mode check the details of the error with the Error Viewer or Event Viewer Refer to the MELSECNET H Interface Board User s Manual For SWODNC MNETH B for details Details on Flicker entered OFF or ea occurred fo ee occurred or aa occurred oe occurred a PCI bus error has not occurred PCI bus error has occ
10. be ensured even at high frequencies e Holes made in the control cabinet must be 10 cm 3 94 in diameter or less If the holes are 10 cm 3 94 in or larger radio frequency noise may be emitted In addition because radio waves leak through a clearance between the control panel door and the main unit reduce the clearance as much as practicable The leakage of radio waves can be suppressed by the direct application of an EMI gasket on the paint surface Our tests have been carried out on a panel having the damping characteristics of 37 dB max and 30 dB mean measured by 3 m method with 30 to 300 MHz Series type KITAGAWA INDUSTRIES CO LTD US series ZIPPERTUBING JAPAN LTD 71TS series SEIWA ELECTRIC MFG CO LTD EO2SOO0A All tests carried out by Mitsubishi are carried out with a panel having maximum 37dB average 30dB 30 to 300MHz 3m dimension measurement damping characteristics 2 Leading the power and earth wires Lead the personal computer s earth and power wires as indicated below a Provide an earth point for the control panel near the personal computer s power supply and earth the personal computer s FG terminal FG frame ground with an earth wire electric wire for earthing as thick and short as possible wire length should be approx 30cm or shorter The FG terminal acts to relieve noise generated in the personal computer to the earth so the earth wire impedance must be as low as possible As the earth
11. ceeeeesseeeeeeeeeeees 8 5 1 2 Installing into the Control Panel cccceceeeeeeeeeeeeeeeeeeeeeeeeneeeeaaeees 10 6 eo Gable Sns rars ae ge ere nee tree ner et Rete cee eter Rr een mer ete 12 5 1 4 Noise filter power supply line filter ce eeeeceeeeeeeeeeeeeeeeaeeeeeeeees 13 VV FING E EA edn tus ated occas advbt walidtcit S A 14 7 Installing Software Packages cccccssssseececeeeseeeeeeeaeeeseeeeeeeeeseeeeeseaaeeeeeees 15 7 1 Installation procedures ccccccsssscccceeescecseseeceeeeseeeeeeeeeneaseeeneeeeesseseeees 15 12 ICONS to beTfegistered si a e e a e e a a a 16 8 Using the Manual PDF Data ccccccccseseseeceseeneseeeeeeseeesseeeessanaeeeeeees 17 8 1 Procedures for viewing MANUAI c ccseeeecececeeeeeeeeeeeaeeeeeeeeeaaaeeeeeeeenees 17 8 2 Operating the manual sars ae E EEEO 18 9 External Dimensions vstiavasseiasiecn dhe achiethcrn nna t aden yaveent acerca autuaaasee 19 A 4 About the Manuals The following manuals are also related to this product In necessary order them by quoting the details in the tables below Related Manuals Manual name Manual No Model code MELSECNETH H Interface Board User s Manual For SWODNC MNETH B The system configuration software package SH 080128 installation uninstallation and each utility s operation 13JT25 method accessible range devices and troubleshooting are explained Option Q corresponding MELSECNET H N
12. condary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties For safe use e This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life e Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi e This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel Country Region Sales office Tel U S A Mitsubishi Electric Automation Inc Hong Kong Mitsubishi Electric Automation 500 Corporate Woods Parkway Vernon Hong Kong Ltd Hills IL 60061 U S A 10th Floor Manulife Tower 169 Electric Tel 1 847 478 2100 Road North Point Hong Kong Brazil MELCO TEC Rep Com e Assessoria Tel 852 2887 8870 China Mitsubishi Electric Automation Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Paraiso Sao Paulo SP Brazil 4 Tel 86 21 6120 0808 Tel 55 11 5908 8331 Taiwan Setsuyo Ente
13. d confirm that the following products are enclosed Type Q80BD J71LP21GE MELSECNETHH Interface Board apari SWODNC MNETH B MELSECNET H software package CD ROM MELSECNETHH Interface Board User s Manual Hardware a ee Software License Agreement 2 Performance Specifications The performance specifications of the MELSECNET H board are given below Q80BD J71LP21GE Maximum number of link points per network e MELSECNET H mode MELSECNET 10 mode Maximum number of links LY LB 8 2 x LW lt 2000 bytes per station e MELSECNET H Extended mode LY LB 8 2 x LW lt 35840 bytes Mumbar ar Stallone 64 stations one control stations 63 normal stations connected per network Connection cable Optical fiber cable Overall cable distance 30km 98430 ft Distance between stations 62 5 GI optical cable 2km 6562 ft Maximum number of 239 networks Transmission path type Double loop Communication method Token ring method Maximum number of groups 32 During MELSECNET 10 mode 9 Synchronization method Frame synchronization method ing Coding method NRZI coding Non Return to Zero Inverted HDLC compliant frame format Error control method CRC X X1 X 1 and retry with overtime Automatic return function loop back function control station shift RAS function function etc Transient transmission N N communication Special cyclic transmission Low speed cyclic transmission Number of moun
14. em communications rate 10 Mbps enabling large volume communications at high Also in order to improve the performance of the MELSECNET 10 network and achieve upward compatibility MELSECNET H supports the MELSECNET H mode high performance high speed made and the MELSECNET 10 Mode function compatible and performance compatible mode Jore this manual is for the use of the MELSECNET H board in the MELSECNET H mode so if you are using the MELSECNET H board in the MELSECNET 10 mode please refer to the QnA Q4AR Compatible MELSECNET 10 Network System Reference Manual Manual display section Clicking any contents item in the bookmark section with the mouse changes the screen in the manual display section 16 9 External Dimensions 1 Q80BD J71LP21GE 147 5 73 fp S 153 5 97 141 5 50 ee L L_ 99 3 86 121 4 72 Leo Unit mm in Microsoft Windows Windows NT are registered trademarks of Microsoft Corporation in the United States and other countries Adobe and Acrobat are registered trademarks of Adobe Systems Incorporated Other company names and product names used in this document are trademarks or registered trademarks of respective companies 17 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage se
15. etwork System Reference Manual PLC to PLC network The MELSECNET H network system s system SH 080049 configuration performance specifications functions 13JF92 handling wiring and troubleshooting are explained Option Q QnA Q4AR corresponding MELSECNET 10 Network System Reference Manual The MELSECNET 10 network system s system IB 66690 configuration performance specifications functions 13JF78 handling wiring and troubleshooting are explained Option A7OBDE J71QLP23 A70BDE J71QLP23GE A7OBDE J71QLR13 A70BDE J71QLR23 MELSECNET 10 Interface Board User s Manual For SW3DNF MNET10 The MELSECNET 10 board s system configuration performance specifications functions handling wiring and troubleshooting are explained Option IB 0800035 13JL93 Remarks MELSECNET H Interface Board User s Manual For SWODNC MNETH B is enclosed with the CD ROM as a set with the software package A printed version of the manual is available as an option Indicate the manual No Model code when placing an order for a printed version of the manual A 5 1 Outline This manual explains the methods of handling the Q8OBD J71LP21GE MELSECNETIH interface board hereinafter referred to as the MELSECNET H board The MELSECNET H board can be used as a control station or normal station in the MELSECNET H network system PLC to PLC network The MELSECNET H board cannot be used in the remote I O network Unpack the product an
16. he product When turning on the power and operating the module after having installed the MELSECNET H board and doing the wiring always attach the cover for the device module in which the MELSECNET H board is installed There is a risk of electric shock if the module cover is not attached Perform soldering the coaxial cable properly If the soldering is incomplete it may cause the module malfunction Take care that foreign objects such as chips or wiring debris do not get on the MELSECNETI H board This can result in fire breakdowns or malfunctioning Insert the communication cable securely into the MELSECNET H board connector After it has been inserted check to make sure that it is not being lifted up A faulty connection can lead to faulty input or output For the communication cable specialized skills and tools are required to connect the plug and cable The connector plug itself is a custom part When purchasing consult with the nearest Mitsubishi Electric System Services Inc If the connection is incomplete this can result in a short fire or malfunctioning Disposal Instructions A CAUTION When disposing of this product treat it as industrial waste A 2 Revisions The manual number is given on the bottom left of the back cover Print Date Manual Number Mar 2001 IB NA 0800188 A_ First edition Jun 2001 1B NA 0800188 B Section 7 1 Section 8 1 Feb 2002 IB NA 0800188
17. hen required and always forward it to the end user INSTALLATION PRECAUTIONS Use the MELSECNET H board in an environment as described in the general specifications listed in this operating manual If the board is used in an environment outside the ranges described in the general specifications it may result in an electric shock fire malfunctioning damage to or deterioration of the product Be sure to shut off all phases of the external power supply used by the system before installing or removing the MELSECNET H board If all power is not turned off this will result in failure of the MELSECNET H board or malfunctioning Securely mount the MELSECNET H board to the PCI bus slot of the mounting device If the MELSECNET H board is not mounted correctly this may lead to malfunctioning failure or cause the board to fall When mounting the MELSECNET H board take care not to become injured by the components that are installed or surrounding materials Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the MELSECNET H board Failure to do so may cause a failure or malfunctions of the MELSECNET H board A 1 WIRING PRECAUTIONS Be sure to shut off all phases of the external power supply used by the system before performing work such as installing the MELSECNET H board and wiring If all power is not turned off there is a risk of electric shock or damage to t
18. hing by soldering a wire onto the shield section of the shielded cable as shown below is not recommended The high frequency impedance will increase and the shield will be ineffective Shielded cable Wire Crimp terminal 10 5 1 4 Noise filter power supply line filter A noise filter is a component which has an effect on conducted noise It is not required to fit the noise filter to the power supply line but fitting it can further suppress noise The noise filter has the effect of reducing conducted noise of 10 M Hz or less The precautions required when installing a noise filter are described below 1 Do not bundle the wires on the input side and output side of the noise filter When bundled the output side noise will be induced into the input side wires from which the noise was filtered Input side Input side power supply side power supply side Introduction Filter Filter Output side device side Output side device side a The noise will be included when b Separate and lay the input and the input and output wires are output wires bundled 2 Earth the noise filter earthing terminal to the control cabinet with the shortest wire possible approx 10 cm 3 94 in Remarks Reference noise filters are shown below Noise filter type Rated current Rated voltage FN343 3 01 SCHAFFNER 34 FN660 6 06 een 250V ZHC2203 11 11 6 Wiring The
19. osari Pune 411026 India TEL 33 1 5568 5568 Tel 91 20 2712 3130 South Africa Circuit Breaker Industries Ltd Australia Mitsubishi Electric Australia Pty Ltd Private Bag 2016 ZA 1600 Isando 348 Victoria Road Rydalmere South Africa N S W 2116 Australia Tel 27 11 928 2000 Tel 61 2 9684 7777 Aa MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN Specifications subject to change without notice Printed in Japan on recycled paper
20. precautions for connecting the optical fiber cable with MELSECNET H board in an optical loop system are given below Refer to the MELSECNET H Interface Board User s Manual For SWODNC MNETH B for details on the wiring method 1 When connecting an optical fiber cable the following restrictions on the bending radius must be observed Please confirm bending radius of the cable with the cable used 2 Please maintain the optical fiber cable permissible bending radius with a checking tool Enquiries for the checking tool for optical fiber cable bending radius maintenance are handled by Mitsubishi Electric System Service Corporation Please contact Mitsubishi Electric System Service Corporation for detail 3 When laying the optical fiber cable do not touch the fiber core of the cable connector or module connector or let dirt or dust collect on it If oil from the hands dirt or dust should adhere to the core the transmission loss will increase causing a malfunction in the data link Do not detach the cover until the cable is attached 4 When attaching or detaching the optical fiber cable to from the module hold the cable connector securely with the hands 5 Connect the cable connector and module connector securely until you hear a click sound 6 When attaching or detaching the optical fiber cable to from the module make sure to power off the personal computer and external power supply 12 7 Installing Software Packages
21. rprise Co Ltd Germany Mitsubishi Electric Europe B V German 6F No 105 Wu Kung 3rd Rd Wu Ku Branch Hsiang Taipei Hsine Taiwan Gothaer Strasse 8 D 40880 Ratingen Tel 886 2 2299 2499 GERMANY Korea Mitsubishi Electric Automation Korea Tel 49 2102 486 0 Co Ltd U K Mitsubishi Electric Europe B V UK 1480 6 Gayang dong Gangseo ku Branch Seoul 157 200 Korea Travellers Lane Hatfield Hertfordshire f Tel 82 2 3660 9552 AL10 8XB U K Singapore Mitsubishi Electric Asia Pte Ltd p 307 Alexandra Road 05 01 02 Tel 44 1707 276100 Mitsubishi Electric Buildi Italy Mitsubishi Electric Europe B V Italian Singapore Egoi urang e EEE PO Tel 65 6470 2460 entro Dir Colleoni Pal Perseo Ingr Thailand Mitsubishi Electric Automation Thailand Via Paracelso 12 20041 Agrate Brianza Co Ltd Milano Italy Bang Chan Industrial Estate No 111 Tel 39 039 60531 Moo 4 Serithai Rd T Kannayao Spain Mitsubishi Electric Europe B V Spanish A Kannayao Bangkok 10230 Thailand Branch Tel 66 2 517 1326 Carretera de Rubi 76 80 Indonesia P T Autoteknindo Sumber Makmur E 08190 Sant Cugat del Valles Muara Karang Selatan Block A Utara Barcelona Spain No 1 Kav No 11 Kawasan Industri Tel 34 93 565 3131 Pergudangan Jakarta Utara 14440 _ France Mitsubishi Electric Europe B V French P O Box 5045 Jakarta 11050 Indonesia Branch Tel 62 21 6630833 India Messung Systems Pvt Ltd ee ee Electronic Sadan NO III Unit No15 3 M 1 D C Bh
22. table Maximum 4 boards 2 boards Mounting slot PCI bus slot half size Occupied slot 5VDC internal current 0 454 consumption 1 The mode is set with the MELSECNET H utility Refer to the MELSECNET H Interface Board User s Manual For SWODNC MNETH B for details 2 The number of mountable boards is the total of the MELSECNET H boards Q80BD J71LP21 25 Q80BD J71LP21G Q80BD J71LP21GE Q80BD J71BR11 and MELSECNET 10 boards A7OBDE J71QLP23 GE A70BDE J71QBR13 A70BDE J71QLR23 3 Handling This section explains precautions when handling the MELSECNET H board and the installation environment 3 1 Precautions when handling The following are precautions to be noted when handling the MELSECNET H board DANGER While energizing do not touch the connector Doing so may result in electric shock or cause malfunctioning c AUTION Fasten the MELSECNETI H board securely using the installation screws and tighten the installation screws securely within the specified torque range If the screws are loose this may cause malfunctioning If the screws are tightened too much this could cause damage to the screws or unit leading to malfunctioning Do not directly touch the conductive section of the MELSECNET H board Doing so could result in malfunctioning or breakdown of the MELSECNET H board Before handling the MELSECNET H board touch a grounded metal object to discharge the static electricity from the human body
23. ting System 14 8 Using the Manual PDF Data The MELSECNET H Interface Board User s Manual For SWODNC MNETH B is enclosed in the same CD ROM as the SWODNC MNETH B MELSECNET H software package The operating manuals may either be used by reading them directly from the CD ROM or by installing them on the HD They can be used at the user s option The manuals are in the form of PDF data which can be viewed using Acrobat Reader of Adobe Systems Inc 8 1 Procedures for viewing manual The following explains the procedure up to manual reading and details of the Manual folder 1 Procedure up to manual reading Designate the CD ROM drive with My Computer or Explorer s Acrobat Reader installed in the personal computer No Double click on ar505 exe in acrobat and install Acrobat Reader E Start Acrobat Reader and agree to the Software License Agreement Install the manual data onto the HD Copy pdf into the C MESLEC directory kkk Double click on pdf in Manual ooo Se View the manual 1 8MB of open space is required in the hard disk 2 The PDF data in the Manual folder can be viewed by Agreeing to the Software License Agreement 15 2 Details of the Manual folder For details on the contents of the Manual folder refer to readme txt in the CD ROM The storage location of readme txt is as follows
24. urred This connector is used to connect the optical fiber cable 1 The cable terminal has the following type of configuration aAa Board top BS LED QQ IN Reverse loop transmission IN Forward loop reception Optical fiber cable connection cable OUT Forward loop transmission OUT Reverse loop reception 2 Refer to the MELSECNET H Interface Board User s Manual For SWODNC MNETH B for details on wiring the optical fiber cable Number Details Use prohibited Fixed to RP side 1 The jumper is provided for the Q80BD J71LP21GE with the following serial No Q80BD J71LP21GE The sixth digit from the left of the serial No is 4 or higher nk 2 ak ok ok 4 ak ak 2K 9k 3K 2k 2 2K 2K 3K The serial No of the board can be verified at the part shown in the illustration Serial No Check the Serial field T CO CT 5 EMC Directive For the products sold in European countries the conformance to the EMC Directive which is one of the European Directives has been a legal obligation since 1996 Manufacturers who recognize their products must conform to the EMC Directive are required to declare that their products conform to these Directives and put a CE mark on their products 5 1 Requirements for conformance to EMC Directive The EMC Directive specifies that products placed on the market must be so constructed that they do
25. wire acts to relieve the noise the wire itself has a large noise element Thus the short wire acts to prevent the earth wire from functioning as an antenna b The earth wire led from the earthing point must be twisted with the power supply wires By twisting with the earthing wire noise flowing from the power supply wires can be relieved to the earthing However if a filter is installed on the power supply wires the wires and the earthing wire may not need to be twisted 9 5 1 3 Cables The cables led from the control panel have a higher harmonic noise element Thus the cables act as antennas outside the control panel and radiate noise Always use shielded cables for those cables led out of the control panel The shielded cable is also effective for increasing the noise withstand level 1 Treating the shielded cable s shield a Treat the shield near the outlet from the control panel If the earth point is not near the outlet the cables after the earth point will cause electromagnetic induction and will generate a higher harmonic noise b Peel part of the shielded cable s sheath and earth a wide section of the exposed shielded section against the control panel Clamp fittings can be used as shown below Note that the painting on the inner side of the control panel against which the clamp fitting is contacted must be masked te Shield section Ti fitting E Paint mask Shielded cable Note The method of eart