Contents

1. Channel 1 Dwell Time is initially selected for programming 17 The Channel buttons add Dwell Times to the selected channel as follows up to 30 seconds Chan 1 2 sec Chan 2 4 sec Chan 3 8 sec Chan 4 16 sec For example if the Channel 1 and Channel 3 LEDs are lit the Dwell Time is ten seconds 2sec 8sec 3 Press the Channel button s corresponding to the desired Dwell Time 4 Press the PROG button to display the next channel to be programmed for Dwell Time The channels advance in numerical sequence when the PROG button is pressed 5 Press and hold the PROG button down for two seconds to exit program mode 18 Enabling or Disabling Automatic Alarm Reset 1 Press the PROG button for two seconds and release it to put the system into program mode The PROG LED will light The SEQ LED will be lit 2 Press the PROG button six times to advance through the other programming functions All four channel LEDs will be off to indicate Automatic Alarm Reset programming is selected 3 Press the ALM RESET SEQ button to toggle between Option A or Option B See page 6 The DWELL TIME ALM SEQ LED will flash for Option A The DWELL TIME ALM SEQ LED will be OFF for Option B 4 Press the PROG button for two seconds to exit program mode 19 System Programming Status LED DWELL ALM tat 1 2 3 4 TIME alm RESET PROG eae ALM SEQ SEQ
2. Number of Alarm Inputs 4 Alarm Input Connection Screw terminal block 2k Ohms EOL resistor configuration Number of Alarm Outputs 1 25 Alarm Output Type Alarm Indications Screw terminal block open collector sink 50 mA max normally open Built in alarm buzzer flashing alarm LED System Mode Operation Home Sequential and Program Input Voltage 12 1 5 VDC Power Input Connection Power Consumption Storage Temperature Operating Temperature QW 12VDC 750 mA 25 C to 60 C 13 F to 140 F 10 C to 50 C 14 F to 122 F Humidity 95 Relative Humidity or less non condensing Dimensions 215 mm W x 160 mm D x 130 mm H 8 1 2 W x 6 1 4 Dx 5 1 4 H Weight 0 9 Kg 2 Ibs Power Supply Included 26 27 C amp Kis a registered trademark of C amp K Components Inc IntelliVision is a registered trademark of C amp K Systems Inc Cle Copyright 1998 C amp K Systems Inc SYSTEMS P N 5 051 586 00 Rev A http www cksys com
3. when the monitor receives an alarm The open collector alarm output shorts to ground goes low for 30 seconds when triggered The audible alarm sounds for 20 seconds Automatic Alarm Reset Options There are two options for automatic alarm reset after the completion of the alarm period Option A The system returns to sequential mode after the alarm period The Alarm channel LED flashes until the ALM RESET button is pushed Option B The system will only display alarmed channels until ALM RESET is pressed Master Arm Disarm This feature allows the user to enable or disable the Alarm Inputs by pressing the ALM RESET SEQ button and the PROG button at the same time Terminology Sequential Mode Camera images are displayed in programmed sequence Sequen tial mode is overridden when the monitor goes into Alarm mode Manual Mode Camera image is selected manually by pressing the selected channel button and sequential mode is stopped Video Loss There is no video signal from one or more cameras Sensor Alarm Dry contact inputs from external sensors A 2k Ohm End of Line EOL resistor is required at the sensor Normally Closed NC contacts are wired in series with the EOL resistor Normally Open NO contacts are wired in parallel across the EOL resistors Power LED wor e C Power ON OFF Button 1 9 K ove I Selection Buttons sos 3 GG 4 a d as
4. Alarm Reset Sequential Mode Button Q Program Button Laer ine T Dwell Time LED G te Alarm LED Function Buttons ON OFF The button must be held down for two seconds to turn the unit ON A momentary push turns the unit OFF PROG Activates Programming mode when held down for two seconds Switches between channel Alarm and Dwell Time programming modes Exits from program ming mode when held down for two seconds 8 ALM RESET SEQ Activates Sequential mode Resets sensor alarm and alarm memory Resets the Video Loss audible alarm ALM RESET SEQ and PROG Simultaneously pressing these two buttons toggles the Master Arm Disarm function Channel Selection Switches into Manual mode Selects channel to be programmed sensor alarm enable or Dwell Time setting in program mode Disables sequential mode Sound Types Steady Sensor alarm is detected Pulsating Video loss is detected Inputs and Outputs Power Input 12VDC 1 Amp Sensor Alarm Input Terminal Block Four external sensor inputs associated with the four camera channels Alarm Output Alarm output terminal provided for external devices Video Output 75 Ohm BNC coaxial video output connector for use with an external video monitor Video Input Four BNC connectors for camera cables terminated in 75 Ohms Tint Adjusts the video image hue C
5. Channel Selection Programming is selected e O O e O O e Channels 1 amp 4 are selected in sequential mode Alarm Enable Program O e e O O e O ming is selected Sensor inputs 2 amp 3 are enabled Dwell Time Programming e O O O e O O Q is selected Dwell Time of two seconds is selected Automatic Alarm Reset O O O O O O Programming is selected Option A is selected Table O Steady Off System mode Channel Dwell Time is deselected Legend Steady On System mode Channel Dwell Time is selected 3 Flashing Video Loss Alarm is detected 20 System Operating Status LED DWELL ALM Status 1 2 4 TIME ALM RESET PROG 3 ALM SEQ SEQ Sequential Mode is e O O O O O e selected Channel 1 is being monitored S is selected Sensor 4 is in O O O e O O O alarm and Channel 4 is being monitored Home Mode is selected O O O e O e O O Channel 4 is being monitored Master Arm is enabled Video loss is detected on O e O O O channels 1 amp 3 Channel 4 is being monitored Table O Steady Off System mode Channel Dwell Time is deselected Legend Steady On System mode Channel Dwell Time is selected 3 Flashing 21 Video Loss Alarm is detected Frequently Asked Questions and Answers 1 What happens when sensor alarms are detected The system switches to the alarm channel instantly The Alarm pie
6. IntelliVision vau User Manual FCC Notice This equipment has been tested and found to comply with the limits for a field disturbance sensor pursuant to Part 15 of the FCC Rules The user is cautioned that changes or modification not expressly approved by C amp K Systems could void the user s authority to operate this equipment Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules The limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Industry Canada Notice This digital apparatus does not ex
7. ant to see The system stops sequencing through the rest of the cameras ALM RESET SEQ LED will extinguish Activate Program Mode Press the PROG button and hold it down for two seconds Exit Program Mode Press the PROG button down and hold it for two seconds The unit will automatically drop out of programming after 30 seconds of no button activity Clear Alarm Memory Press the ALM RESET SEQ button Entering and exiting Program Mode will also reset the alarm memory Master Arm Disarm Press the ALM RESET SEQ button and PROG buttons simulta neously to enable or disable the Alarm inputs When Master Arm is selected the ALM LED will be lit 13 System Programming The following features can be programmed in the IV AM Sequential switching sequence channels Enable Disable alarm input for each channel Camera Dwell Time for each channel Enable Disable automatic alarm reset In programming mode the PROG button is used to step through the four program ming functions listed above 14 Selecting Camera Channel for Sequential Display 1 Press the PROG button for two seconds and release it to put the system into program mode The PROG LED will light The SEQ LED will be lit LEDs of all selected channels will be lit 2 Press the button of the channel you want to select The Channel LED will light The selected channel is now in the sequence 3 To remove a channel from the sequence press
8. ceed the Class B limits for radio noise emissions from digital apparatus as set out in the Radio Interference Regulations of the Canadian Department of Communications Le present appareil numerque n met pas de bruits radioelectriques d passant les limites applicables aux appareils num rique de Classe B prescrites dans le r glement sur le brouillage Radioelectrique Edicte par le Minist re des Communica tions du Canada Contents Product Features o ooo ssh 4 Safety Notice 2 a ooo oo s s sss 4 Terminology ra dadie a a LAE ss 7 Function Buttons a aL 8 Sound Types gt aL 9 Inputs and Outputs aL 9 Installation 2 oo o ll aL 12 System Operation gt 5 2 o ooo s 18 System Programming ooo ssh 14 System Programming Status we 20 System Operating Status a ooo ls 21 Frequently Asked Questions and Answers ois 22 Troubleshooting ooo ls 24 Product Specifications gt 0 0 00 0 0 0 0 o ooo ol 25 The IntelliVision IV AM is a 4 channel Thin Film Transistor Liquid Crystal Display Video Monitor The IV AM has Automatic Sequential switching with programmable channel selection alarm enabling and channel Dwell Time Any combination of Black amp White and Color cameras can be connected to the system Sensor Alarm Detection and Video Loss Detection are provided for added security Product Features Automati ntial Switching camera images are displayed on the monitor according to prog
9. mera is not pro grammed or the correct channel is not selected There is no video signal on one or more channels in the programmed sequence Make sure the adapter is plugged in Make sure that the camera channel is programmed on the monitor and that the channel is selected on the monitor Make sure that the cable is connected to the correct channel and that there is power to the camera There is a steady audible alarm There is a sensor alarm If the sensor alarm is invalid check that the EOL resistor is connected properly See illustration on page 11 The VCR cannot record the video from the monitor There is no video from the unit or the VCR is not correctly setup Make sure that the VCR is connected to the Monitor Out 75 Ohm BNC connector Make sure that the VCR is in RECORD mode Make sure that the Record tab is on the tape cassette 24 Product Specifications IV AM NTSC and PAL models Number of Video Inputs Display Type TFT Active Matrix Color LCD Display Format pixels 600 H x 234 V 4 BNC connector Video Input Signal Number of Video Outputs 1Vp p composite video color or B W 1 for monitoring or VCR BNC connector Video Output Signal 1Vp p composite video Gain Unity 1 1 Bandwidth 20 MHz 3dB S N Ratio 55 dB typical Cross Talk 45 dB typical Dwell Time 2 to 30 seconds programmable in 2 second increments
10. olor Adjusts the video image color saturation Contrast Adjusts the video image dark to light contrast Brightness Adjusts the video image brightness 10 HR NT ocu 1H 4 voro out 32 1 40 IIS mmm AC DC AM CAMERAS ADAPTER STROBE LIGHT 1A 12VDC MIN EXTERNAL RELAY 20mA 16VDC v EXTERNAL PROTECTION Y DIODE H l IN914 OR EQUIV EXTERNAL POWER SUPPLY Sl MOTION SENSOR Typical Application 11 Installation 1 Connect DC power to the unit and switch the power ON only after all connections have been made A 12VDC 1A AC to DC adapter is required 2 Connect the 75 Ohm coaxial cable from the camera video output to the appropriate channel input Up to four cameras may be connected to the unit 3 Connect the external alarm outputs to the alarm input terminals on the terminal block Up to four alarm inputs may be connected to the unit 4 Connect the Alarm Out terminal to the VCR or external alarm device 5 Connect a 75 Ohm coaxial cable from the Monitor output to the external video monitor or VCR 12 System Operation Activate Sequential Switching Press the ALM RESET SEQ switch ALM RESET SEQ LED will light Activate Manual Mode Press Channel button for the camera you w
11. rammed channel selection and Dwell Times Manual Switching The selected channel camera image is displayed on the monitor ignal L Detection A flashing video channel LED and a pulsing audible alarm is activated if there is a loss of video on any of the programmed channels Safety Notice The system should be unplugged from the wall and disconnected from the camera cables during electrical storms and during extended periods of disuse to protect the unit from damage due to electrical discharge or power surges Automatic Alarm Channel Monitoring The display switches to the camera corre sponding to the channel alarm input Video Monitor Output An auxiliary output allows connection to a Video Cassette Recorder or external monitor User Programmability Channel selection Dwell Time and alarm input enable are user programmable The Dwell Time can be set to any value from two to 30 seconds The Dwell Time is the length of time the camera image will be displayed on the monitor before the monitor Switches to the next programmed camera when in sequential mode An alarm input can be connected to any of the four input channels and enabled or disabled System Memory Protection The programmed settings are stored in an Electrically Erasable Programmable Read Only Memory EEPROM and are saved when power is turned off External Alarm Output An output is provided for triggering an external device
12. the button of a selected channel The channel LED will go out when the channel button is pushed 4 Press the PROG button and hold for two seconds to exit program mode 15 Enabling or Disabling Alarm Input for a Video Channel 1 Press the PROG button for two seconds and release it to put the system into program mode The PROG LED will light The SEQ LED will be lit LEDs of all selected channels will be lit 2 Press the PROG button again The ALM LED will light 3 Press the channel button that you want to enable or disable The channel LED will light if you are enabling the alarm for the channel or extinguish if you are disabling the alarm for that channel 4 Press and hold the PROG button down for two seconds to exit program mode 16 Setting the Dwell Time for a Video Channel In Dwell Time Programming the PROG button is used to advance through the four channels in numerical sequence This allows the Channel buttons to be used to input the Dwell Time for the currently selected channel Observe the monitor to determine which channel is currently selected for programming 1 Press the PROG button for two seconds and release it to put the system into program mode The PROG LED will light The SEQ LED will be lit LEDs of all selected channels will be lit 2 Press the PROG button twice again to advance through the channel selection and alarm enable programming functions The DWELL TIME LED will light
13. zo sounds for 20 seconds The Alarm LED flashes and the Sequential LED goes out After 20 seconds the Alarm Piezo will turn off The Alarm LED will continue flashing In a multiple alarm situation the IV AM will switch between the alarmed channels with a Dwell Time of four seconds f Automatic Alarm Reset Option A is programmed see page 6 the system returns to normal sequential mode 30 seconds after the last sensor alarm The Alarm LED and alarmed channel LED s will continue to flash 22 2 How do you reset the alarm sounder and clear alarm memory Press the ALM RESET SEQ button The alarm sounder will stop and the Alarm LED will stop flashing The ALM RESET SEQ LED will turn on and the monitor will go into sequential mode 3 What happens when video loss is detected The channel LED for the channel that has lost video will flash The Alarm Piezo will pulse for 20 seconds Pressing the ALM RESET SEQ button will silence the Alarm piezo but the video loss channel LED will continue to flash until the video is restored or the channel is deselected in programming mode Video loss channels will be displayed on the monitor with a dwell time of two seconds 23 Troubleshooting Problem Possible Cause Solution Power LED is not lit Power is on but there is no video on the monitor There is a beeping audible alarm The power adapter is not plugged into the unit or the wall The ca