ProComSol DevCom2000 Mobile Software Manual PDF

image

Contents

1. 4 000 mA 0 00 psi 599 99 psi Ready HART Device iew Help Ej Expand the menu by clicking the sign and double click to view the device parameters 2 Double click the parameter you wish to edit The following dialog box appears on the screen 599 99 psi 0 00 psi 3 Double click the parameter you wish to edit from within the Edit Display box The following dialog box appears on the screen MAN 1017 8 9 2011 Our Quality Management System is Page 30 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action P 101 a d 258 URV 599 99 psi 599 99 E 4 Make the change to the value as required Click Set to accept the changes Or press Cancel to cancel the changes 6 Click OK to close the Edit Display dialog box Click on the Send icon to commit the changes to the device 6 3 4 Executing Methods or Standard Operating Procedures Methods are defined in the DD file for the device that DevCom2000 Mobile is connected to You can select the Method and execute it for calibrating the device trouble shooting etc Method execution leads you through a number of steps like in a wizard A Few examples of methods include Setting high and low range calibration points Calibration of the device Run the advanced diagnostic test procedure Execute tests to gather information on device operation To execut
2. 8 Device setup 9 Process variables Diag Service Basic setup 9 Detailed setup 0 03 psi 4 000 mA 0 00 psi 599 99 psi Ready HART Device Yiew Help E 2 Select Device gt Document Device from the main window The Document Device Dialog Box is displayed MAN 1017 8 9 2011 Our Quality Management System is Page 35 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action P 101 a 46336 File Name My Documents HART C Notes Enter notes here E 3 The default directory is HART Configs The default file name is Tag Device ID The filename can be changed by the user Use the Browse button to change directories and or filenames also 4 Enter a Note in the Notes field if desired Maximum of 255 characters 5 Press the Save Device Config button to save device configuration 6 7 PC Interface to Mobile The Windows Explorer program is a convenient way to copy configuration files back to the PC for archiving and storage The Mobile looks like a disk to the Windows file system Below is an example screen shot MAN 1017 8 9 2011 Our Quality Management System is Page 36 ISO 9001 2008 Certified Ni PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual amp My Documents HART Configs En File Edit View Favorites Tools Hel
3. H Calibration Basic setup Status group 1 0x00 Status group 2 0x00 Status group 3 0x00 Ready HART Msg Device iew Help E 3 Select the menu and view the associated parameters to view the device information 6 3 Configuring Device Information 6 3 1 Overview DevCom2000 Mobile allows you to view and configure the field device parameters based on the device description However the device vendor defines most of the parameters at the factory These parameters become read only for the users and the user cannot modify the values The related variables are grouped under various menus of different levels as defined in the DD file Expand or collapse the tree view using the or sign to access the device configuration parameters Following table describes the details about the device configuration Step Action 1 Ensure that the application is running and communications have been established MAN 1017 8 9 2011 Our Quality Management System is Page 24 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action a Main OF Onine 5 Device setup 9 Process variables 9 Diag Service 9 Basic setup 0 03 psi 4 000 mA 0 00 psi 599 99 psi Ready HART Device iew Help E The top pane of the window shows the menu st
4. 2 Select the menu where the editable parameter is present as shown below MAN 1017 8 9 2011 Our Quality Management System is Page 26 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action 4 q 11 20 2 ala Online 9 Device setup 9 Process variables 9 Diag Service 9 Basic setup 9 Detailed setup Sensors i RJ Damping W Snsr temp unit L Device Yiew Help E 3 Tap and hold the variable to edit it A pop up menu will appear on the screen a 11 21 Online Device setup 9 Process variables 9 Diag Service 9 Basic setup 9 Detailed setup 29 Sensors DR Ss Dameing W Snsr tem L DisplayY alue rr Device iew Help Ej 4 Select Edit The following dialog box appears on the screen MAN 1017 8 9 2011 Our Quality Management System is Page 27 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action P 101 a 46 11 22 Damping 1 60 s a o E 5 Tap the Keyboard icon to bring up a keyboard for data entry The screen will now look like this A a 4 11 22 Damping 1 60 s Note that there are several ways to enter data using the Mobile See A
5. DevCom2000 Mobile User Manual 3 SYSTEM REQUIREMENTS The following minimum system requirements are recommended for operation of DevCom2000 Mobile Mobile Device Processor Speed 624 Mhz Memory RAM 128 MB Memory ROM 256 MB Screen 256 color VGA SD Card or Micro SD Card Slot SD Card 500 Meg or greater included with software HART Modem Bluetooth to HART modem ProComSol Ltd supplies HART modems Communication Port Bluetooth Operating System Pocket PC 2003 Windows Mobile 5 0 Windows Mobile 6 x MAN 1017 8 9 2011 Our Quality Management System is Page 7 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual 4 DEVCOM2000 MOBILE INSTALLATION 4 1 Prerequisites You need to be familiar with the basic functions of the following when installing the DevCom2000 Mobile tool e Microsoft Windows e HART communication interface e HART field device e Mobile Syncing using Windows ActiveSync 4 2 Installing the DevCom2000 Mobile Application To install the DevCom2000 Mobile application perform the following steps Step Action 1 Insert the DevCom2000 Mobile SD Card into the SD slot of the Mobile device Connect the Mobile to your PC and verify the ActiveSync program is running 2 Note The step in this paragraph is only required if the SD Card is not supplied but instead the DD Library is supplied as a program install When the DD library update is installed it is placed in t
6. y PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual QUICK START DevCom2000 Mobile uses Device Descriptions DDs to access data stored in the memory of the smart field device These DDs are developed by the manufacturer for their products and in turn distributed by the HART Communication Foundation HCF worldwide The latest DDs are included as part of the DevCom2000 Mobile installation Visit the HCF website www hartcomm org or the ProComSol website www procomsol com for update information The following steps will allow you to install and quickly begin using DevCom2000 Mobile Step 1 Install the DevCom2000 Mobile application Insert the DevCom2000 Mobile SD Card into the SD slot of the Mobile device Connect the Mobile to your PC and verify the ActiveSync program is running Note The step in this paragraph is only required if the SD Card is not supplied but instead the DD Library is supplied as a program install When the DD library is installed it is placed in the C HCF DDL Mobile Library directory on the PC Copy the Library folder to the SD Card on the Mobile so that the path appears as SD Card Library Please note that on some Mobile devices SD Card may have slightly different text Note You will overwrite the existing SD Card Library subdirectory if this is an update Insert the DevCom2000 Mobile installation CD into the CD drive on your computer The DevCom2000 Mobile i
7. 599 99 psi 599 99 a dzo Options Block Recognizer Keyboard Letter Recognizer Transcriber ag Keyboard Use the stylus to tap letters numbers and symbols on the on screen keyboard to enter typed text directly onto the screen 1 From any application tap the up arrow next to the Input Panel icon 2 Tap Keyboard to display a keyboard on the screen Note To see symbols tap the 123 key 3 Tap a letter symbol or number to enter information 4 Tap OK Letter Recognizer Use the stylus and Letter Recognizer to write letters numbers and symbols on the screen Create words and sentences by writing in uppercase ABC lowercase abc and symbols 123 as instructed here 1 From any application tap the up arrow next to the Input Panel icon 2 Tap Letter Recognizer 3 Write a letter or symbol between the dashed line and baseline To display in uppercase write a letter between the hatch marks labeled ABC To display in lowercase write a letter between the hatch marks labeled abc Write a number or draw a symbol between the hatch marks labeled 123 MAN 1017 8 9 2011 Our Quality Management System is Page 39 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual What you write will be converted to text Note For the Letter Recognizer to work effectively write characters between the dashed line and baseline ee 29 If you are
8. A Troubleshooting Guide eseeeeeseseesseesieeessesrissrssresrtssrestersesstestestisstestensesstesseeseesresereset 36 Appendix B Mobile Data Input Guide s sseeeseeseeeseeseeseeeresrersessresrerstsstissrrsetsressteseesriserestenesereseneesere 37 Appendix C Contact Iii orig Gil ssiri sassesvssasirsetidsaes tipena verkeken eacoir iisk easar giss iai aar 39 MAN 1017 8 9 2011 Our Quality Management System is ISO 9001 2008 Certified DevCom2000 Mobile User Manual Page 3 Xe PROCOMSOL Process Communications Solutions 1 INTRODUCTION The Smart Device Communicator DevCom2000 Mobile allows access to and management of a HART compatible DevCom2000 Mobile User Manual field device s configuration and calibration This manual provides the information about the Hardware setup Communication with Smart devices and functions of DevCom2000 Mobile DevCom2000 Mobile is unique in that it uses the DD of the connected device to determine what information to display what variables are available for edit and what procedures to follow for calibration setup and maintenance 1 1 Acronyms and Definitions Acronym Definition DD Device Description File This contains the device information DDL Device Description Language HCF HART Communication Foundation DevCom2000 Mobile Smart Device Communicator 1 2 Conventions Used in This Manual Following formatting conventions are used in this guide Conventio
9. Services Services f File Transfer 2d Information Exchange Serial Port Personal Network Server Service settings Enable service __ Authorization required Authentication Passkey required Encryption required General Accessibility Services About Ej 5 Select the Advanced tab to see what outgoing COM port was assigned to the Modem Itis shown as COM8 below Also make sure the box is unchecked as shown MAN 1017 8 9 2011 Our Quality Management System is Page 13 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action Bluetooth Settings g 46355 CD Bluetooth Serial Port settings Ports Inbound COM Port 5 Outbound COM Port oO Default device for outgoing serial connections HART Moder Display the device selection screen the next time an outgoing serial connection is attempted E MAN 1017 8 9 2011 Our Quality Management System is Page 14 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual 4 5 Connecting to the HART Network The DevCom2000 Mobile application communicates with the HART Field Devices through a HART compatible communication interface e g a HART Modem Using this communication interface you will transmit real time HART data between DevCom2000 Mobile and the connected HART compatible field device There are a wide variety of HART compatible interf
10. Using the Pop up Menus When you tap and hold a menu item a Pop up menu will appear with different functionality depending on what menu item type was selected A summary Menu Explanation Open The Menu Pop up Menu offers the Help following sub menu options Device Details Open Opens the selected menu Help Brings up help information on the selected menu Device Details Brings DD information for the connected device Only works on the Online menu Edit The Variable Pop up Menu offers the Help following sub menu options Displayvanie Edit Brings up the Edit menu for the selected variable Help Brings up help information on the selected variable Display Value Shows the selected variable on the full screen with scroll bars This is so the entire variable can be seen without abbreviations Execute The Method Pop up Menu offers the Help following sub menu options Execute Starts the selected Method in a new window Help Brings up help information for the selected Method 5 2 3 Using the Toolbar When you start the application by default the toolbar buttons appears on the main window If it fails to display click View gt Toolbar option from the menu bar to bring up the toolbar Following are the buttons available in the DevCom2000 Mobile application toolbar to perform the necessary tasks Button Description Corresponding Menu Option a Connect to a new devic
11. to cancel the Method execution 6 Click Help to get specific help for that step of the Method This Help information is provided by the device DD 6 4 Calibrating HART Field Devices Calibration of field devices and loop test are achieved by executing the Methods or Standard Operating Procedures that are specific to device Methods are defined based on the test parameters specific to the device providing information for the calibration of that device See the previous section for Method execution 6 5 Viewing the Device and Communication Status DevCom2000 Mobile provides the user with the ability to monitor the device specific status of the device and the communication network When there is error communicating with the device it is recognized and indicated to the user The user can view more details of such errors using the View gt Device Condition from the main window To view the device and communication status perform the following steps Step Action 1 Ensure that the application is running and communications have MAN 1017 8 9 2011 Our Quality Management System is Page 33 ISO 9001 2008 Certified Nu PROCOMSOL Process Communications Solutions Step Action DevCom2000 Mobile User Manual been established os 10 26 12 3 9 Main oa i 3 8 Device setup 9 Process variables 9 Diag Service 9 Basic setup Device se
12. 8 9 2011 Our Quality Management System is Page 1 ISO 9001 2008 Certified Ay PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step 4 Activate DevCom2000 Mobile Launch DevCom2000 Mobile by selecting the DevCom2000 Mobile icon from the Start menu You will now be asked to Activate DevCom2000 Mobile You can use it for 10 days before you need to Activate it Select No to continue in Demo mode Activation only needs to occur once See Section 4 3 for details On some Mobile devices another step is required in order to select the DD library location This is only required if the SD card has a name that is not standard In this case a screen will come up where the user will need to select the path of the DD Library in the Mobile device The selection will appear in the box at the bottom of the screen Step 5 Browse the Device Operating DevCom2000 Mobile is similar to working with Windows Explorer DevCom2000 Mobile communicates to the field device establishes a connection and learns its identity Once DevCom2000 Mobile knows its identity DevCom2000 Mobile locates the device s DD and loads it From this point forward operation of DevCom2000 Mobile is determined by the DD provided by the product s manufacturer If a DD for the device is not present a generic DD will be used By default DevCom2000 Mobile will open the Browser window The organization of the data in this explorer style window is dictated by the de
13. MSOL Process Communications Solutions DevCom2000 Mobile User Manual 5 USING DEVCOM2000 MOBILE 5 1 Starting DevCom2000 Mobile The HART compatible field device must be connected to a Mobile running DevCom2000 Mobile to configure or calibrate the field device or to view the field device s data Make sure to establish the physical connection between the field device and the DevCom2000 Mobile computer With the physical connection established launch DevCom2000 Mobile by clicking the DevCom2000 Mobile icon on your program screen You can also start the application by going to your Mobile s Start Menu and selecting Start gt DevCom2000 Mobile Step Action 1 Start the DevCom2000 Mobile Application The following application window is displayed Er A 10 44 Ready HART Device Yiew Help E DevCom2000 Mobile will then automatically identify the field device and open a communication channel to i e a connection with the field device 2 Setting Preferences Device gt Preferences If communications cannot be established you may need to change the communication settings using the Preferences dialog box The serial port box will show the available com ports Select the one your HART modem is using You may also change the polling options for the computer If you do not know the poll address of the device you are trying to communicate with use the default address 0 setting MAN 1017 8 9 2011 Our Quality Management Sy
14. aces Please follow the manufacturer s instruction for connecting your interface to the Mobile This manual uses the HART modem manufactured by ProComSol Ltd called the HM BT BAT ER It uses the Bluetooth interface Turn the HM BT BAT ER on It is assumed you have already performed the Bluetooth pairing procedure See the HM BT BAT ER documentation for details Using the clips on the wires from the HART modem connect to the device across the 4 20ma signal If a suitable load resistance is not available a 250Q resistor must be placed in series with the device power supply Figure 1 Typical DevCom2000 Mobile Hardware Setup 4 6 Uninstalling the DevCom2000 Mobile Application To uninstall the DevCom2000 Mobile application perform the following steps on the PC Step Action 1 Click Start gt Programs gt ProComSol gt DevCom2000 Mobile gt Uninstall DevCom2000 Mobile 2 Or Click Start gt Settings gt Control Panel gt Add Remove Programs MAN 1017 8 9 2011 Our Quality Management System is Page 15 ISO 9001 2008 Certified y PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action 3 In the Add Remove Programs dialog window select the DevCom2000 Mobile program that you want to uninstall 4 Click Remove Click OK to confirm the removing of the selected application MAN 1017 8 9 2011 Our Quality Management System is Page 16 ISO 9001 2008 Certified Ay PROGO
15. ber and User Codes The above information will be processed at ProComSol Ltd and an appropriate response will contain the required Reg Keys The user will need to enter the Reg Keys and the Serial Number If successful the program continues as normal You will not need to perform the activation process again 3 We have tried to make the Activation process as easy as possible Contact ProComSol Ltd if you have any difficulties 4 On some Mobile devices another step is required in order to select the DD library location This is only required if the SD card has a name that is not standard In this case a screen will MAN 1017 8 9 2011 Our Quality Management System is Page 10 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action come up where the user will need to select the path of the DD Library in the Mobile device The selection will appear in the box at the bottom of the screen nE Online browse en x 12 58 lok Select DD Library Location Mobile Device Application Data ConnMgr Documents and Settings iPAQ File Store My Documents Program Files SD Card Temp Windows MAN 1017 8 9 2011 Our Quality Management System is Page 11 ISO 9001 2008 Certified Nu PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual 4 4 Bluetooth Settings on the Mobile Bluetooth must be enabled on the Mobile To enable and setu
16. de Problem Will not communicate Hardware Check Verify the following 1 Com port number on Preferences Dialog box matches HART interface hardware 2 Loop power supply is on 3 Loop resistance between 250 ohms and 1Kohms 4 Loop current within HART limits 5 If multi drop configuration all transmitters in loop have unique addresses 6 HART interface hardware connected across loop resistor or across transmitter terminals Problem Get the message Error opening COMx Verify the following 1 Com port number on Preferences Dialog box matches HART interface hardware 2 HART interface hardware installed Problem The system cannot find the path specified error box Try the following 1 Verify that the DevCom2000 Mobile SD Card is inserted into the SD slot of the Mobile 2 Select the path of the DD Library in the Mobile device when starting up DevCom2000 Mobile Problem Serial Number does not match Activation input boxes Note the following 1 The Program Serial Number is different than the Activation Codes 2 Activation Codes required after 10 days of Demo program use MAN 1017 8 9 2011 Our Quality Management System is Page 38 ISO 9001 2008 Certified Ay PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Appendix B Mobile Data Input Guide There are several different ways to enter data on a Mobile Tap the up arrow next to the Input Panel icon The following will appear URV
17. e been established MAN 1017 8 9 2011 Our Quality Management System is Page 22 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action a 10 26 wiz cial 9 Main OF Onine 5 0 Device setup 9 Process variables Diag Service 9 Basic setup 0 03 psi 4 000 mA 0 00 psi 599 99 psi Ready HART Device iew Help E The top pane of the window shows the menu structure and the bottom pane of the window displays corresponding parameters of the menu selected The menus are displayed depending on the type of device that is being connected These menus are displayed based on the DD file of the particular device If no DD is available for the device the DevCom2000 Mobile will select the standard DD This should provide limited functionality for the device NOTE If a parameter is updated that is not supported by the device you will receive an error 2 Expand the menu by clicking the sign and double click to view the device parameters Below is an example of an expanded menu MAN 1017 8 9 2011 Our Quality Management System is Page 23 ISO 9001 2008 Certified Ay PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action a A 10 54 Online J Device setup 9 Process variables 3 0 Diag Service FI Test device
18. e Device gt New Device ii Send parameter changes to the device MAN 1017 8 9 2011 Our Quality Management System is Page 20 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Button Description Corresponding Menu Option P bi Cancel parameter changes View more status on Device View gt Device Condition and Communication Command 48 status Shows About screen Help gt About 5 2 4 Familiarizing with Icons DevCom2000 Mobile application uses different icons to represent different elements of the application Following table lists the icons and their meanings Icon Meaning oA u h EH Indicates a menu or submenu in the navigation tree Indicates a currently selected menu or submenu in the navigation tree Online menu icon The actual DD menu comes under this Indicates a Variable item Indicates a Method Standard Operating Procedure item Indicates an Edit Display item MAN 1017 8 9 2011 Our Quality Management System is Page 21 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual 6 FUNCTIONS AND BASIC OPERATIONS 6 1 Overview DevCom2000 Mobile allows the user to monitor and configure a single device at a time in the field Each device is associated with the DD when the device information is present A DD may contain any of the following parameters elements Variab
19. e a Method perform the following steps Step Action 1 Ensure that the application is running and communications have been established MAN 1017 8 9 2011 Our Quality Management System is Page 31 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action a q 10 26 2 7 3 8 3 0 Main oF Onine 3 Device setup 9 Process variables 9 Diag Service J Basic setup E Device setup a Py 0 03 psi a AO 4 000 mA h LRY 0 00 psi URY 599 99 psi Ready HART Device Yiew Help Ej Expand the menu by clicking the sign and double click to view the device parameters 2 Select the menu where the method is present and tap and hold to bring up the Method pop up menu 4 4 3 06 siz slal 9 Output condition LY Process variables 3 ERE 9 HART output Device iew Help Ej 3 Select Execute to start the Method Below is an example of a Method screen MAN 1017 8 9 2011 Our Quality Management System is Page 32 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action P 101 a 46307 Choose analog output level Press OK button to continue method execution or Abort button to abort E 4 Click OK to move to the next dialog in the Method sequence Or click Abort
20. encounter problems when using DevCom2000 Mobile or this guide please contact ProComSol Ltd See Appendix C for contact information Please provide the following information Create a text description of the problem If possible provide the text in event sequence which will enable the duplication of the problem Provide information about the system This information must include e DevCom2000 Mobile version and serial number e Mobile information make model and operating environment Windows version e Device information make model and device revision e Point of contact complete mailing address telephone number and e mail address e The date and time of the problem occurrence MAN 1017 8 9 2011 Our Quality Management System is Page 5 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual 2 OVERVIEW OF DEVCOM2000 MOBILE Field devices such as flow pressure level temperature transmitters and valve positioners provide the physical connection to the process These devices allow the control system to monitor and manipulate process conditions HART devices maintain a real time database of process configuration identification and diagnostic information This information can be accessed using the HART Field Communications Protocol HART devices are capable of providing functions and features far beyond the basic task of providing a process input or accepting a control output to manip
21. g procedure will activate the software Step Action 1 Start the DevCom2000 Mobile Application The following Demo mode window is displayed sE DevCom2000 en x 4 34 DevCom2000 2 Demo mode You have 10 days left Activate Now 96 76 30MB 1 71GB GY iPAQ Wireless Calendar Contacts MAN 1017 8 9 2011 Our Quality Management System is Page 9 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action If you want to evaluate DevCom2000 Mobile before purchasing select No You will have 10 days of unlimited program use before you will need to purchase a license 2 If Yes is selected the following window appears Activation a 4x 4 37 ok Provide these codes to ProComSol User Code 1 11002740 User Code 2 1436273432 Enter keys below to activate Reg Key 1 fo ss Reg Key 2 fo ss Phone 216 221 1550 Email support procomsol com You will then need to contact ProComSol Ltd to obtain the registration keys You must supply the User Codes to ProComSol Ltd support personnel You can activate in any of the following ways 1 Call ProComSol Ltd at 216 221 1550 Have the program Serial Number and User Codes ready 2 Or send an email to support procomsol com containing your company name Serial Number and User Codes 3 Or send a fax to ProComSol Ltd 216 221 1554 containing your company name Serial Num
22. he C HCF DDL Mobile Library directory on the PC Copy the Library folder to the SD Card on the Mobile so that the path appears as SD Card Library Please note that on some Mobile devices SD Card may have slightly different text Note You will overwrite the existing SD Card Library subdirectory if this is an update 3 Insert the DevCom2000 Mobile CD into the CD ROM drive Auto run should begin installation if not 4 Click Start and choose Run From the Run window click Browse In the Look In box browse to your CD drive 6 Double click the drive to access the CD content Look for the setup exe file and double click the same This process will take you through a sequence of installation wizard steps 8 Follow the instructions on the upcoming screens to complete the Installation 9 Once completed on the PC a step remains on the Mobile Select the Device option on the screen below MAN 1017 8 9 2011 Our Quality Management System is Page 8 ISO 9001 2008 Certified Xe PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action Choose a location to install ProComSol DevCom2000 Mobile SD Card iPAQ File Store Space Needed 6059 KB Space Available 143846 KB Install fa Cancel 4 3 Activating DevCom2000 Mobile DevCom2000 Mobile must be activated for continued use If the program is not activated it will not run after 10 days The followin
23. isappear Step 8 Exit When you are through working on the field device simply exit DevCom2000 Mobile Once the program exits you can then disconnect the HART interface hardware MAN 1017 8 9 2011 Our Quality Management System is Page 2 ISO 9001 2008 Certified Xe PROCOMSOL Process Communications Solutions Table of Contents QUICK START ita sas tis ec aE E a eas as ate Sah eee ea aa teats ec renty RNG 1 l WRU CUO siksene ee ets E E sees vata E E E O EEN 4 1 1 Acronyms and Definitions ississpseii eeii i e ane aeiia oha 4 1 2 Conventions Used in This Manual eeeeseeseeseseseesiesrssresrissrssressessresiesrrssresrensessresreseessresees 4 1 3 Do oc me nt CP ea ANI he a a ae Select a alae a a a ee a Tera aseetan 5 J4 Gettin TU ioe se cost Scat aaa es geste Seen E EE cea E E ms eee eee 5 2 Overview of DeyCom2000 Mole sisisi assets catia ind lore ape ee ae 6 3 System RegurementS rreren sch gn ae ng esl TE papas ance ado fond care E agen aca Sepa nae 7 4 DevCom2000 Mobile Installations ics isis ccsccsss scsscassecacssassioesnsncecesadncvecnasyc dee sseabcaeanssgueusaie cubeesatedenaabacce 8 A PreregtisiteS siosio E E E E E E E EE 8 4 2 Installing the DevCom2000 Mobile Application eesessesesesseseesreerrerersrrsresrersresrrerersresrese 8 4 3 Activating DevCom2000 Mobile xis ccsiccsececscescdcaccasapececasscusacdsedasecepscvabdiasddensaiendiaineedeaanees 9 4 4 Bluetooth Settings on the Mobile stasceniscscnnonre sited sansnecsa
24. ite will be converted to text MAN 1017 8 9 2011 Our Quality Management System is Page 40 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Appendix C Contact Information ProComSol Ltd Process Communications Solutions 13001 Athens Ave Suite 220 Lakewood OH 44107 USA Phone 216 221 1550 Fax 216 221 1554 Email sales procomsol com support procomsol com Web www procomsol com MAN 1017 8 9 2011 Our Quality Management System is Page 41 ISO 9001 2008 Certified
25. le A variable is defined as the data contained in the device e g Device Firmware Version There are two types of variables Editable Variable It allows the operator to modify the value and download it to the device Non Editable Variable It is a read only data from the device Edit Display This option is used to view a group of parameters You can also modify a single parameter from this group based on which other parameters of the device get altered For example if the Engineering Unit of the device is modified the corresponding Low Limits and High Limits change as per the Engineering Unit set Method Standard Operating Procedure SOP This option helps to perform various tests on the device for instance Self Test and Loop Test A Method or SOP is a series of steps that are executed in a sequence results in the completion of some device related tasks When a method gets invoked it gives various warning messages and options to the user by which the user can thoroughly test the device If a test is aborted by operator command at any stage of the sequence the method invokes additional steps to bring the device back to its original state before the test 6 2 Viewing Device Configuration typical actual view may change based on DD To view the configuration of the device that is connected to DevCom2000 Mobile perform the following steps Step Action 1 Ensure that the application is running and communications hav
26. n Description Words in bold type Field names including buttons in the display or important phrases gt Arrow Windows pull down menus and their options Courier font UPPERCASE UPPERCASE within angle brackets are separated by gt For example click Device gt New Device to connect to a new device Information that you type parts of the code quoted for explanations or as examples Acronyms Command keys For example press lt ENTER gt MAN 1017 8 9 2011 Our Quality Management System is Page 4 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual 1 3 Document Organization DevCom2000 Mobile user manual is organized into the following sections Section 1 Describes the scope and objective of DevCom2000 Mobile user manual along with the organization of the remaining part of the manual Section 2 Provides an overview of the DevCom2000 Mobile application and its architecture Section 3 Provides the information pertaining to hardware and software requirements for the DevCom2000 Mobile application Section 4 Provides the steps to install activate and uninstall the DevCom2000 Mobile application Section 5 Provides the steps to start the DevCom2000 Mobile application and connecting to field devices Section 6 This section explains different aspects of the DevCom2000 Mobile application and its functionalities 1 4 Getting Help If you need help or
27. nstallation will automatically start and guide you through the installation process Install DevCom2000 Mobile in its default location If the installation program does not begin automatically please go to Start gt Run gt and enter CDRom drive letter setup exe This will begin the installation program After the install is finished on the PC select Device on the Mobile to finish installation See Section 4 2 for details Step 2 Connect the communication interface Connecting to a HART device requires special interface hardware to be attached to your computer These interfaces HART Modems are available from ProComSol Ltd and other sources The interface should be connected and configured The preferred interface is a Bluetooth HART Modem ProComSol Ltd model HM BT BAT ER See Section 4 4 for details Step 3 Connect to the field device Find a connection point for the device s 2 wire 4 20mA loop you wish to communicate with For communications you must have a suitable load resistance or a 250Q resistor must be placed in series with the device Using the clips from the HART interface connect to the HART device While the HART Communication signal is available anywhere along the 4 20mA wiring it is often easiest to connect across the field device s terminals caution should be observed when working in a hazardous area many Mobile s are not rated for intrinsic safety and should only be connected in a safe area MAN 1017
28. p ay Q sxx 7 ki J Search E Folders jae By x id Ez Folders x E 8 Mobile Device E My Windows Mobile Based Device E Databases D ConnMgr H O iPAQ File Store E O My Documents OLDREL a profiles E O Program Files E 3 SD Card DB Library D Temp D windows O Business 4 Dictionaries E HART Configs 5 My Music E O My Pictures O Personal O Templates v 5 P 101 _735012 1 86KB Text Document 6 18 2008 5 04 35 E test Ext 1 82KB Text Document 6 11 2008 1 29 48 E test2 txt 1 87KB Text Document 6 11 2008 1 54 06 The default location for the saved configuration files is the directory My Documents HART Configs Simply highlight the desired files and copy to your PC Once on the PC they can be viewed or imported to many different software packages 6 8 DD Library Updates When the DD library update is installed it is placed in the C HCF DDL Mobile Library directory on the PC Copy the Library folder to the SD Card on the Mobile so that the path appears as SD Card Library Please note that on some Mobile devices SD Card may have slightly different text Note You will overwrite the existing SD Card Library subdirectory MAN 1017 8 9 2011 Our Quality Management System is Page 37 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Appendix A Troubleshooting Gui
29. p the Mobile for Bluetooth communications with a Bluetooth HART Modem perform the following Step Action 1 Tap Start gt Settings Then select the Connections tab The following screen is displayed Settings a 46354 X 2 0 Beam Bluetooth BT Phone Manager Connections iPAQ LEAP Wireless as Network Cards Personal Connections E 2 Select the Bluetooth icon Make sure Bluetooth is turned on If not select Turn On from this screen Bluetooth Settings a EAT CD Bluetooth General Current profile z Bluetooth status Bluetooth is ON Use the Bluetooth Manager to set connections General Accessibility Services About E MAN 1017 8 9 2011 Our Quality Management System is Page 12 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action 3 Select the Accessibility tab and verify the following settings Bluetooth Settings a E CD Bluetooth Accessibility Device Identification Name Pocket_PC Address 08 00 37 03 F5 EE Use PocketPC device name For Bluetooth Accessibility Allow other devices to connect All devices C Paired devices only Other devices can discover me General Accessibility Services About Ej 4 Select the Services tab and verify the following settings for Serial Port Bluetooth Settings 4 3 55 GD Bluetooth
30. ppendix B for more options Make the changes to the parameter value as required Click Set to accept the changed value The change gets reflected as shown MAN 1017 8 9 2011 Our Quality Management System is Page 28 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action a d 11 23 SiR e722 Online 5 0 Device setup 9 Process variables 9 Diag Service 9 Basic setup 9 Detailed setup H 0 Sensors Damping W Snsr temp unit L Ready HART Device iew Help E 8 Click on the Send icon to commit the changes to the device 6 3 3 Edit Display The Edit Display is a variation on the Variable edit An additional window helps the user view a group of parameters based on the DD You can also modify a single parameter from this group Parameters linked to the edited field will be updated automatically To view and configure these variables perform the following steps Step Action 1 Ensure that the application is running and communications have been established MAN 1017 8 9 2011 Our Quality Management System is Page 29 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action 9 Main Sees Online 3 Device setup 9 Process variables 9 Diag Service J Basic setup
31. ructure and the bottom pane of the window displays corresponding parameters of the menu selected 2 Expand the menu by clicking the sign and double click to view the device parameters 3 There are three types of variables dynamic read write and read only The parameters that are grayed out indicate that these are dynamic variables variables that get updated online by the device or read only variables Following points describe how the device parameters represents their status when connected to DevCom2000 Mobile Bold Font Modifiable Values Normal Font Menu Item 4 Select the parameter and configure the values as required The subsequent topics explain how to configure device parameters MAN 1017 8 9 2011 Our Quality Management System is Page 25 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual 6 3 2 Variable To edit the parameter variables of the connected device perform the following steps Step Action 1 Ensure that the application is running and communications have been established E 10 26 siz 8l8l 9 Main OF Onine J Device setup 9 Process variables Diag Service 9 Basic setup 0 03 psi 4 000 mA 0 00 psi 599 99 psi Ready HART Device iew Help E Expand the menu by clicking the sign and double click to view the device parameters
32. sonnusdes ponunenen sheet acensuaessnsaededasaayanssinns 12 4 5 Connecting to the HART Network ip oscccasccaesteieetatde acsvacncitectdspasecederannedawcdeenubastanaacsetes 15 4 6 Uninstalling the DevCom2000 Mobile Application sesssseseseeseeseeerresersresseserssressresresresee 15 5 Usim ey COIN ZOU Mobile scese ereinen on eee arana Oe SE O AE aP EREE EEA EA ERN 17 5 1 Starting DevCom2000 Mobile seeseseeeseseesessessresrersersresrersrssrissrssrssteserssrenreseresrensessresees 17 5 2 Getting Familiarized with DevCom2000 Mobile Explorer seeeseeeeeeeereeererrerersrerse 19 6 Functions and Basic per amos 2055 ccs arsseacdaceseceaapsnertacs senccepeaenccensaeteansasnieacaessanteee srauni Eav resas 22 OL AVR VIC Ws eierens aiee e E AE alana EEEE KEE aE hat 22 6 2 Viewing Device Configuration typical actual view may change based on DD 22 6 3 Configuring Device nformation esseseseseesessresrissersrrsresrersrestisersstesenerserenteseresrensessresees 24 64 Calibrating HART Field Devices s s5sspsscpcccocssetts aces eirian E EE E ES 33 6 5 Viewing the Device and Communication Status eseeseeeeeeseerreeresreesireresrerrirerisrersersreses 33 6 6 Saving Device Configuration To Memory sssessesssessesissersresrissresresreseresrterissresrersessresres 35 6 7 PG Interface to Mobilecicinnenrenec nian ee E E E E A E 36 6 8 DD Library Upd teS Benne ee vce er Pree ne eI re ee e E aE En EEE EEAS rer rer ES RTEA 37 Appendix
33. stem is Page 17 ISO 9001 2008 Certified Ay PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action 2 z p 101 a 4 10 25 Serial Port Preferences Serial Port COMS v Search by Poll Address use poll address 0 only O find first poll address O use poll address 5 E 3 When the device is connected to DevCom2000 Mobile the browser window appears with online i e root menu selected ub Pa AR 9 Process variables 9 Diag Service 9 Basic setup Device setup a Py 0 03 psi a AO 4 000 mA h LRY 0 00 psi URY 599 99 psi Ready HART Device Yiew Help Ej The top pane of the window shows the menu structure and the bottom pane of the window displays corresponding parameters of the menu selected The DevCom2000 Mobile screens shown in this document are only an example of what you may see when connected to your field device What you see is actually controlled by the DD and the device The menus data status and configurations displayed MAN 1017 8 9 2011 Our Quality Management System is Page 18 ISO 9001 2008 Certified Xe PROCOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action are specified by the field device s manufacturer in the DD itself 4 Select the required menu to configure or review the field device s data 5 2 Ge
34. tting Familiarized with DevCom2000 Mobile Explorer 5 2 1 Using the Menu Bar Menus DevCom2000 Mobile Explorer provides visual representation and structure of the application window Menu Explanation New Device Preferences Document Device Exit x Toolbar Status Bar Device Condition Available DDs The Device Menu offers the following sub menu options New Device Connect to a new device or reconnect to the same device Preferences Brings up the Preferences dialog box Document Device Brings up the Document Device dialog box Exit Exit DevCom2000 Mobile The View Menu offers the following sub menu options Toolbar Hide or show the Tool Bar Status Bar Hide or show the Status Bar Device Condition View detailed device status Available DDs Shows what DDs are available to DevCom2000 Mobile DevCom2000 Help Device Help About DeyCom2000 PDA The Help menu offers the following sub menu options DevCom2000 Mobile Help Brings up Help information for the DevCom2000 Mobile application Device Help Brings up help information for the connected device if available About DevCom2000 Mobile Shows copyright information support information and application Serial Number MAN 1017 8 9 2011 Our Quality Management System is Page 19 ISO 9001 2008 Certified y PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual 5 2 2
35. tup Pi h SO h LR h UR 0 03 psi 4 000 mA 0 00 psi 599 99 psi Ready HART Device iew Help E Expand the menu by clicking the sign and double click to view the device parameters Select View gt Device Condition from the main window or choose the status icon 2 displayed from the toolbar Following window is gt az P 101 e MR 3 27 Vertical Parity error Overrun error Framing error Longitudinal Parity error EEEE B Buffer overflow KD Ej The Device Status tab option shows the status of the device and the communication network The individual status is indicated by green and red LEDs Communication Status Device Yiew Help MAN 1017 8 9 2011 Our Quality Management System is Page 34 ISO 9001 2008 Certified Ay PROGOMSOL Process Communications Solutions DevCom2000 Mobile User Manual Step Action 3 Additional tabs may be available depending on the DD Tap the arrow buttons to move amongst the tabs 4 Click X to close the Status window 6 6 Saving Device Configuration To Memory HART Device configurations can be saved to memory as a text file to document the device Fields are delimited with a comma so that the data can be imported into configuration management software packages To save device configurations to disk perform the following steps Step Action 1 Ensure that the application is running and communications have been established
36. ulate process conditions Many HART compatible device manufactures create a DD Device Description describing all of these functions and features specific to that device The DD also provides information essential to the successful configuration and calibration of the device DevCom2000 Mobile uses these DD s to access the data stored in a device providing full configuration and setup support for all registered HART DD s DevCom2000 Mobile accesses and presents field device data based solely on its DD No other files information or custom drivers are required DevCom2000 Mobile is intended to monitor and configure a single device at a time it is directly connected to the current loop of the particular device and e Provides user interface to configure the HART field device e Provides a means to configure and view all the parameters related to HART field device and e Provides an option to view the detailed status and diagnostic capability of the device DevCom2000 Mobile allows viewing and modifying of field device parameters based on the DD Using the device s DD DevCom2000 Mobile performs various tests to verify the proper operation of the HART device DevCom2000 Mobile runs as a standalone software package and must have a HART compatible modem attached to the system to interrogate the HART base devices MAN 1017 8 9 2011 Our Quality Management System is Page 6 ISO 9001 2008 Certified Xe PROCOMSOL Process Communications Solutions
37. vice DD The top tree pane of this window shows the logical groups of field device data These are called Menus The bottom data pane shows the data any sub groups and any standard operating procedures found on a given menu You can browse through the field device data by expanding click symbol or collapsing click the the menus in the tree pane You can also double click the folder symbol when seen on the data pane symbol Step 6 Modify the Device s Configuration The Browser allows access to all of the data exactly as described by the product s manufacturer s DD When you find elements of the field device s configuration you want to change simply double click and edit the data Once you have changed the configuration to suit your needs press the Send icon to commit the data and transfer it to the field device Step 7 Performing Maintenance and Testing the Field Device Many devices perform Methods or Standard Operating Procedures SOPs that may need to be performed to ensure the device is in peak condition These Methods may include calibrating the loop current trimming the transducer values or performing some diagnostic test on the field device Methods appear in the data pane just like data does Double click on the Method and it will start running in a separate window The Method will guide you through the process ensuring the procedure is completely and consistently performed When the Method is complete the window will d
38. writing a letter like p write the top portion within the dashed line and baseline and the tail portion below the baseline If you writing a letter like b write the bottom portion within the dashed line and baseline and the top portion above the dashed line Note To view help on using Letter Recognizer open the program and tap the question mark next to the writing area Transcriber Use the stylus and Microsoft Transcriber to write words letters numbers and symbols anywhere on the screen 1 From any application tap the up arrow next to the Input Panel icon 2 Tap Transcriber to display the Transcriber Intro screen 3 Tap OK 4 Tap New at the bottom of the screen 5 Begin writing on the screen What you write will be converted to text Note To teach Transcriber your style of writing tap on the a icon at the bottom of the screen to display the Letter Shapes screen and follow the instructions Block Recognizer Write letters numbers and symbols using the stylus and Block Recognizer Create words and sentences by writing letters and numbers in specific areas 1 From any application tap the up arrow next to the Input Panel button 2 Tap Block Recognizer 3 Write a word letter or symbol between the hatch marks To type text write a letter between the hatch marks labeled abc To type numbers or symbols write a number or symbol between the hatch marks labeled 123 What you wr