Home

User manual

image

Contents

1. Set Calling when alarm 13 1 Change master number 14 new master number The number should be less than 16 digits Master family guest Send MMS image to appointed mobile phone 30 password mobile number image quantity Deactivate infrared detector 31 0 Master family Activate infrared detector 31 1 Master family Change auto alarm image size Master family Change auto alarm image quantity Master family Set image brightness Master family Set Image direction Master family Set Image contrast Master family Set interval of auto capturing image Add or modify E mail address 108 Email address Master family Delete E mail 109 Email address Disable sending MMS image to E mail when alarm 3 s 110 0 Master family Default Send MMS image to E mail when alarm 110 1 113 family user Master family Delete family user 4 5 Note Specify the family user you want to detele for 113 means delete all the family users Set timing send MMS image i See aes Master family po Command SCSCSC SS 32 value Value 1 160x128 2 320x240 QVGA default 3 640x480 VGA For example 32 1 means auto alarm image size is 160 128 33 quantity The quantity range 2 8 default is 5 If image size is 640x480 the quantity is 1 or 2 34 value The value should be 1 2 3 4 5 1 is darkest 5 is brightest default value is 4 35 value The value 1 means up down 2 left right 3 normal
2. ALWAYS ON OFF time 4 digit 24 hour for example 0000 for 0 00 2359 for 23 59 Once timing parameters setting of intelligent switch is successful it will send SMS tothe master number 2 When the setting ALWAYS ON time comes the host sends control code and ON the intelligent switch 3 When the setting ALWAYS OFF time comes the host sends control code and OFF the intelligent switch 10 6 Disbind intelligent switch to host The following operation is to disbind the the intelligent switch to host 1 Clear coding of intelligent switch In any status press and hold any switch button until the Coding indicator light red flashes 3 times then release the button and intelligent switch clear code successfully 2 Also use master s mobile phone send SMS to the host 193 switch name Host removes the intelligent switch successfully 3 If user want to delete all information of the intelligent switch on host use master s mobile phone send SMS to the host 193 4 From then on the host can not operate the intelligent switch any more 11 Reset camera Method 1 Swith on the camera after the indicator light flash red press the RESET button until the indicator light turns to green and then release the RESET button The device is resumed to default setting Method 2 Master sends SMS to camera O08 password The reply SMS you get Factory settings have been restored successfully 12 Getting help If forget the SMS command user can
3. settings Not including the password For master user and family user 07 For guest 07 password 9 Audible Visual Alarms A indicator B indicator 9 1 Bind wireless Audible Visual Alarms to host 1 ON the Audible Visual Alarms Disconnect the power supply of wireless Audible Visual Alarms first then push the switch to PANEL 2 seconds later and then connect the power supply 2 Press the REMOTE button which is on the bottom of the wireless Audible Visual Alarms A indicator light flash fast it means the Audible Visual Alarms is in the Learning status 3 At the send time sending an SMS or phone to switch host arm disarm status see 3 Quick Start 2 deployed 3 disarm after the success of the host status switch the Audible Visual alarm will have a tick sound then switch the host status again the audible visual alarm have a tick sound this means the audible visual alarms have binded to the host a successfully 4 Press the REMOTE button to save the received code and exit the learning status 9 2 Disbind wireless Audible Visual Alarms to host To disband the Audible Visual Alarms to host MUST reset the the audible Visual Alarm to restore the factory settings the operation is as follows 1 Off the Audible Visual Alarmss 2 Press SENSOR or REMOTE button then turn the audible visual alarm After 3 seconds the audible visual alarm light RED light it means the audible visual alarms has been restored factory set
4. send SMS to get help The device will send the command list or user guide to user s cell phone by SMS or MMS Get normal command help User sends following SMS command to the device For master user and family user 09 For guest 09 password 4 Chapter 4 Maintenance x Store and use the device in suitable temperature Too high or too low temperature will likely to damage the device N Try to keep the host and all its accessories dry Do not store and use it in the bathroom or other place with high humidity Do not allow pour water or other liquids into the device otherwise it might cause malfunctions w Do not store and use the device in dusty 5 Do not use alcohol acetone and other similar solvents to clean it Wipe it with soft wet cloth a Do not attempt to open it except as instructed If the device does not work normally try to resolve it as the guide of the general troubleshooting For the problem can not be solved contact with the dealer immediately To prolong the life span of the battery connect the device to the power supply to charge the built in Lithium battery for 4 hours every 3 months if the camera does not use for long time Charge the battery at least 12 hours at the first time use to achieve the full performance of the battery Chapter 5 General Troubleshooting No General Trouble Possible Reason 5 Solution i Pre
5. value 1 means ON 192 switch name working day Always ON time Always OFF time 193Hswitch name
6. 38 value The value should be 1 2 3 4 5 default value is 4 103 time Interval time should be 3 10 unit is 0 1 second default value is 5 You can only set one email Disable timing send MMS iamge 115 0 116 work day period1 start time period1 end time period1 interval period2 start time period2 end time period 2 interval period3 start time period3 end time period3 interval For example 116 1 0800 1200 1430 1630 30 means during 8 AM to 12 AM and 2 30 PM to 4 30 PM of every Monday the device will auto send out a MMS image in every 30 minutes Work day one digit 0 8 O for everyday 8 means from Monday to Friday 1 for Monday 2 for Tuesday 3 for Wednesday 4 for Thursday 5 for Friday 6 for Saturday 7 for Sunday Start time end time 4 digits 24 hours such as 0000 means 00 00AM 2359 means 11 59 PM Interval time 1 3 digits 1 480 means sending MMS image interval 1 480 minutes interval Value 1 can be choose from 0 and 1 0 means not lock sim card 1 means lock sim card Value 2 can be choose from 0 and 1 0 means not lock camera 1 means lock camera Value 3 can be choose from 0 and 1 0 means not lock Operator 118818 Master family i Activate infrared body detector Master family Deactivate infrared body detector Masteritamily Master family Master family Change language 127 value O means Chinese 1 means English Master family Timing arm the devi
7. GSM remote camera User manual 1 The GSM SIM card for GSM camera should be PIN code de activated and it needs to activate caller ID presentation amp MMS functions 2 Be sure to remember and keep the product s password SIM card number secret Don t disclose them to others to ensure your privacy safety Chapter 1 Product Feature This product needs to use GSM SIM card It can send MMS images to MMS enabled mobile phone with a color display or to an e mail address Intergrated PIR detector to provide precise and timely alarm Built in CMOS camera and infrared LED Even in dark environment camera can get clear images SMS remote control User can control the camera by SMS command or calling Listen in the monitoring area Call the device number to listen in monitoring area Build in speaker User s voice can be broadcasted via build in speaker to scare the unvited vistor Multimode alarm Camera can send alarm messages by SMS MMS E mail or standard phone cat Schedule monitor User can set the camera working as the preset schedule Built in Lithium battery Rechargeable battery ensures operation im case of external power failure Easy installation Wireless connection The product can be installed at any place you want ieee GON ga O OO SI iO Chapter 2 Host Instruction 1 Resetkey 2 Base board 3 Speaker 4 Light sensor 5 Camera 6 Infrared lights 8 pcs 7 Indicator light 8 PIR sensor 9 Micropho
8. MS command it will automatically reply Note 1 The symbol in SMS command can not be ignored No space character can be included within the commands 2 Two SMS commands or more can be sent in one SMS at the same time Different SMS commands must be apart with semicolon in English L3 The max length of SMS parameters is 50 characters or digits 1 Start the camera The device should be bind with Master phone mobile for the first use or after resuming to factory settings After binding with master mobile phone the device can automatically sends alarm SMS to master once alarm triggered Edit and send the following SMS to camera 00 After setting the device will send the following SMS to your mobile Welcome Password 1234 2 Network parameter setting The user sends following SMS message in order to Set MMS center 124 MMScenter The MMScenter should be the MMS center address of GSM provider For example 124 http mmsc monternet com Set APN parameters 125 GatewayIP WAPGatewayPort HTTPGatewayPort APN APNusername APNpassword For example 125 10 0 0 172 9201 80 cmwap wap wap Successful SMS reply Para ttenni Set sending MMS message via WAP 148 0 Sending MMS message via HTTP 148 1 3 Switch the camera defense status Arm the camera is to activate the alarm function of remote camera In this status the infrared body detector is in work status Disarm the camera is to deactivate the alarm functio
9. ater Method 2 Send following SMS command to camera For master number and families number 03 image quantity For guest number 03 password image quantity The camera will reply Image capturing request received The camera is busy sending the MMS image And the caller will receive the MMS image later Note When the image size is set as 160x128 or 320x240 the device can only send max 8 images one time So the image quantity number should be in the range of 1 8 When the image size is set as 640x480 the device can send up to 2 images and the image quantity number should be 1 or 2 6 Alarm setting If the built in PIR detector is triggered the camera will alarm by sending SMS notify MMS image and making a call If you set sending SMS MMS and calling as the default alarm way at the same time once alarm triggered the camera will send SMS MMS and then calling Each alarm way will be carried once each time For calling alarm way the device will dial the master number and family number If there is no answer it will quit the dialing mode after repeated calling three times 7 Listen in live voice Master or family numbers call the device It will answer the call automatically Then you can tisten in live voice of monitoring area 2 8 Check status If the user wants to know the present setting and work status of the device just needs to send one of following SMS to camera and the camera will reply a MMS image including all
10. ce 128 value Refer to Chapter 3 Quick start 3 Timing arm the camera 129 work day period 1 arm time period 1 disarm time period 2 arm time period 2 disarm time period 3 arm time period 3 disarm time Set time period of auto send MMS image Lock camera and SIM card 4 Q24 MMMS centert 125 gateway IP wap port http port APN APN user name APN password Note Don t omit the symbol even when the APN user and APN password are blank Set APN parameter Master family Set timing arm the device schedule Please find instruction of work day arm time and disarm time in Set time period of auto send MMS 143 value M famil Close Open indicator Sa aii The value can be 0 or 1 0 means close the indicator 1 means open the indicator default setting is 1 astray Dist SMS rotation when te power hanes 1440 Master family want 148 value Value 1 means MMS sent by Http way Value 0 means MMS sent by WAP way 150 value Value is number from 0 10 seconds 152 number Number is the device SIM number This command is used to regulate device time Close open the speaker 164 value Value 0 means close value 1 means open 166 vaiue Value 0 means off value 1 means on default is 0 190 switch name value value 0 means always off value 1 means on Sending control code of _ intelligent switch timing 191 switch name value _ value 0 means OFF
11. h the battery Note If the problem can t be solved with above guidelines contact to your local distributor or the factory Appendix SMS command list Only guest user needs add password 1234 in the SMS command after changing the password please change the command accordingly P User Fumction O SMS Command Start the device OO Refer to Chapter 3 Quick start 1 Start the camera i Arm the device 01 Refer to Chapter 3 Quick start 3 Switch the camera defense status Master and family Disarm the device 02 Refer to Chapter 3 Quick start 3 Switch the camera defense status Mater family guest Capture MMS Image 03 password image quantity Refer to Chapter 3 Quick start 5 Capture images Change the password 04 old password new password Add family number 06 family number You are allowed to add up to 10 different family numbers Master family guest Check the statues 07 07 password Refer to Chapter 3 Quick start 8 Check statues Resume to default setting O8 password The password is 4 digits Master family guest Get Usual command list O09 password 09 password 1 Refer to Chapter 3 Quick start 12 Getting help Disable SMS notification when alarm 11 0 Master family TEEDE Send SMS notification when alarm default 11 1 A Disable MMS image when alarm 12 0 Master family Send MMS image notification when alarm default 12 1 Disable calling when alarm Default 13 0 Master family a
12. lligent switch flash one time it means learning successfully 4 The host can save 3 Intelligent switch name only 10 2 Learning of intelligent switch always OFF Do t eee es oe ee ee 3 1 The following instruction of how to let the intelligent switch ALWAYS OFF the learning status For example the HLD 002 intelligent switch when channel 1 working indicator ON and channel 2 3 working indicator OFF Press and hold channel 1 manual switch and light of the channel 1 is OFF till the coding indicator red light flash one time then release the channel 1 switch button and the intelligent switch is in ALWAYS OFF learning status 2 Use master s mobile phone send SMS to the host set ALWAYS OFF control code on the intelligent switch 190 switch name 0 Switch name refers to the intelligent switch named by master cab be letters case sensitive or numbers such as 190 TV 0 3 After received control code the coding indicator of intelligent switch flash one time it means learning successfully 4 The switch name must be same on the ALWAYS ON and ALWAYS OFF command SMS 10 3 Real time control of Intelligent Switch 1 After ALWAYS ON OFF learning finished shut down the channel 1 2 and 3 manual switch on intelligent switch then Channel 1 2 and 3 working indicator light OFF 2 Use master s mobile phone send SMS to the host let host send control code to intelligent switch in this way user can contro the power of i
13. n of the device The connected PIR detector will not work The device will not automatically alarm There are three methods to switch the defense status Method 1 Edit and send following text message to arm the camera O1 The device will reply you that arm the camera successfully with SMS content Armed successfully the device indicator flash still green Edit and send following text message to disarm the camera 02 Device will reply you that disarm the camera successfully with SMS content Disarmed successfully and the camera indicator flash slow green Method 2 Call the device through master number or family number Hang up in 5 20 to arm disarm the device Note If you reset the defense state repeatly the device will reply to notify you that the device is armed or disarmed already 4 Timing arm the camera Timing arm the camera The camera can set on defense automatically according to the preset time schedule To set timing arm the camera you can do as following Set on timing arm the camera 128 1 You will get reply SMS Arming scheduler activated Set off timing arm the camera 128 0 You will get reply SMS Arming scheduler deactivated 5 Capture image Method 1 Master number or family number call the device and hand up within 5 seconds after hearing the ringing tone The device will reply SMS Your request has been received The device is sending image s now And the caller can receive the MMS image l
14. ne 10 Power switch 11 Battery cover 12 Power Interface Mini USB 13 Base board conneting slot 14 Base board installing hole Tip Keep the camera lens clean to insure best imaging quality Indicator Status Instruction Indicator Status Instruction as follower acolar eee Aton Searching the network Infrared body detect alarm Not installed SIM card or the remote camera damaged Defense status Activating the auto alarm function Flash slowly Cancel defense status Canceling the auto alarm function Flash quickly Processing data Successfully resume to factory setting Note Swith on the camera after the indicator light flash red press the RESET button until the indicator light turns to green and then release the RESET button The device is resumed to default setting Light two seconds Note 1 Slow flash is defined as indicator flash 1 time per second quick flash is defined as 2 times per second 2 Under normal condition press the RESET button of camera for more than 10 seconds to close or open the host indicator This can also be done by sms command from mobile About the SMS Command 1 All the SMS commands are composed with symbol and Arabic numerals 2 Master amp family SMS command format code content 3 Guest SMS command format code password tcontent 4 Password is a four digit number The default is 1234 5 The maximum digit of the phone number is 16 6 When camera receives the S
15. ntelligent switch ON 190 Switch Name 1 After received control code all channel working indicators of intelligent switch ON at the same time the socket outlets ON 3 Use master s mobile phone send SMS to the host let host send control code to intelligent switch in this way user can control the power of intelligent switch OFF 190 switch name 0 After received control code all channel working indicators of intelligent switch OFF at the same time the socket outlets OFF 10 4 Intelligent switch ON OFF timing 1 Use master s mobile phone send SMS to the host Active the Timing function of host to send Timing control code to ON the intelligent switch 191 switch name 1 2 Use master s mobile phone send SMS to the host Active the Timing function of host to send Timing control code to OFF the intelligent switch 191 switch name 0 10 5 Intelligent switch timer parameter settings 1 Use master s mobile phone send SMS to the host set host s time of send ON OFF control code of intelligent switch 192 Switch Name working days ALWAYS ON ALWAYS OFF Note The setting must be a working day ALWAYS ON time should be after the ALWAYS OFF time and timing should be at the same day The value of working day ALWAYS ON OFF time as following Working days on digit from O to 8 0 for daily 8 for Mon Fri 1 for Monday 2 for Tuesday 3 for Wednesday 4 for Thursday 5 for Friday 6 for Saturday 7 for Sun
16. ss the ton for 10 d 1 Indicator light does not work The indicator light is closed RESET but on aF 10iseconds aMSEnaNEX METSAGA to open the indicator light Can t start device Indicator 2 Already binded master user for the camera Recover to factory default setting works normally 3 All functions disable Indicator Caller ID presentation or MMS functions of the SIM Contact network provider to active SIM card function Pay for works normally card are not actived insufficient fee of the SIM card the card s REENEN s SIM card was not installed properly Power off the camera and 4 Indicator light is still green Can t find or identify the SIM card g prepely check it again The device doesn t respond to A 5 Device work abnormally Switch off the power check SIM card or reset factory setting any operation Place the camera at other place with strong signal and try again Close the PIN code Network signal is weak or network is busy After starting the device indicator 6 flashs in red color and can not turn to green SIM card PIN code is actived SIM card invalid ee ee Contact with local network operator to check of it Bind a master user to the device Connect the camera to external AC power and charge for at least one hour then restart device Do not bind a master user to the device Battery runs out of power 7 Can t start the device after long time supply wit
17. tings then release button 3 At the same time switch the host arm disarm alarm status there are no any actions of the audible visual alarm it means the disbinding of audible visual alarm to host is success S nE ee 3 SS Ra Channel 2 3 Working Indicator 10 Intelligent switch Channel 1 Working Indicator Coding Indicator Channel 1 Manual Switch Channel 2 Manual Switch Channel 3 Manual Switch Channel 1 Socket 2200w Channel 2 Socket Channel 3 Socket This GSM remote camera supports control up to 3 general 315M Wireless Intelligent switch sockets etc Now we have intelligent switch HLD 002 show above for instructions 10 1 Learning of intelligent switch always ON 1 The following instruction of how to let the intelligent switch always ON the learning status For example the HLD 002 intelligent switch when channel 1 working indicator OFF and channel 2 3 working indicator ON Press and hold channel 1 manual switch and red light of the channel 1 is on till the coding indicator red light flash twice then release the channel 1 switch button and the intelligent switch is on the learning status 2 Use master s mobile phone send SMS to the host set ALWAYS ON control code on the intelligent switch 190 Switch Name 1 switch name refers to the intelligent switch named by master cab be letters case sensitive or numbers such as 190 TV 1 3 After received control code the coding indicator of inte

Download Pdf Manuals

image

Related Search

Related Contents

Descargar Ficha Técnica    Sony Model VPL-CX61 User's Manual  Un Dernier Pour La Route  

Copyright © All rights reserved.
Failed to retrieve file