1. 4 OPTIONS 41 Connecting a remote control A remote control can be connected to the Atlas remote control panel converters for switching on and off The remote control can also be used for remotely SISRISSISISISISIS connecting the six indicator LEDs 10987654321 The leads of the remote control must be connected to the remote control connector see Fig 6 3 3228222 PEHE e 209 53 7 3 ERS P mera m Fig 6 42 Adjusting the output voltage A dangerous voltage is present on some of the metal parts of the components in the converter WARNING The output voltage may only be adjusted by a qualified electrician The converter housing must be opened to adjust the output voltage see Fig 7 The output voltage is set in the factory to 230Vac It can be changed by means of potentiometer Pl see Fig 8 after removing the front panel Always measure the output voltage with a true R M S multimeter 16 victron energie Atlas 24 3500 24 4500 user manual m A victron energie Oo INVERTER gt A 24 2 e e Fig 7 Atlas 24 3500 24 4500 user manual Fig 8 victron energie y PA 17 5 TROUBLESHOOTING If a fault occurs a number of points can be checked If the fault cannot be rectified consult your Victron Energie dealer Problem Possible cause Solution The converter does not The input voltage is too h
2. accukabel rood op de positieve accu aansluiting aan Sluit de negatieve accukabel zwart op de negatieve accu aansluiting aan Controleer of de groene led right brandt Wanneer de rode led wrong brandt zijn de accukabels verwisseld Draai dan de accukabels om en controleer of de groene led right brandt Draai de accu aansluitingen stevig aan Plaats de zekering en zie onderstaande tabel 24 3500 8 x 40A 24 4500 10 x 40A 32 My victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing V 119 e aard accu Ac aansluiting aansluiting uitgang Afbeelding 4 Aansluiten van de 230Vac kabel De AC aansluiting bevindt zich op de printplaat zie afbeelding 4 De 230Vac kabel moet als volgt aangesloten worden e _ Controleer of de omvormer uitgeschakeld is e Sluit de 230Vac apparatuur aan op de AC connector via een drie aderige kabel met een soepele kern en een kerndoorsnede van 6mm De aansluitpunten zijn duidelijk gecodeerd Van links naar rechts L fase N nul en PE aarde Voor de veiligheid moet de aangesloten apparatuur op de AC uitgang voldoen aan de daarvoor geldende veiligheidseisen De omvormer wordt ernstig beschadigd wanneer op de 230 Vac uitgang een andere wisselspanning wordt gezet bijvoorbeeld van een generator Deze WARNING beschadiging valt niet onder de fabrieksgarantie Atlas 24 3500 24 4500 gebruiksa
3. afbeelding 6 8 a FB Afbeelding 6 4 2 Afregelen van de uitgangsspanning Er staat een gevaarlijke spanning op sommige WARNING metalen delen van de componenten in de omvormer De uitgangsspanning mag alleen afgeregeld worden door een bevoegd elektrotechnicus Voor het afregelen van de uitgangsspanning moet de behuizing van de omvormer geopend worden zie afbeelding 7 De uitgangsspanning is standaard afgeregeld op 230Vac Met behulp van potentiometer P1 zie afbeelding 8 na verwijdering van het front kan de uitgangsspanning worden gewijzigd De uitgangsspanning kan alleen worden afgelezen met een True R M S multimeter 36 f victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing Afbeelding 7 Atlas 24 3500 24 4500 gebruiksaanwijzing y Afbeelding 8 victron energie 37 P1 5 STORINGEN In geval van storing kunnen enkele punten gecontroleerd worden Indien de storing niet verholpen kan worden raadpleeg dan uw Victron Energie dealer Mogelijke oorzaak Oplossing De omvormer start De ingangsspanning is te Zorg ervoor dat de niet op hoog of te laag ingangsspanning binnen de goede waarden komt te liggen zie hoofdstuk 6 voor deze waarden De plus en de min van Schakel de de accu s en de omvormer omvormer uit en komen niet met elkaar overeen sluit de accu en de wrong led brandt correct aan Controleer de ingangszekeringen en vervang dez
4. de accukabel aan A controleer or de groene led brandt plaats de zekeringen 1098 7654321 p 9 __ accukabelaansluiting a 3 a one pal a 4 die po uo yoyIMs one yaums mo pel I ubiu pal kd a pA amp A x 4 doc AT981501 CDR victron energie b v Victron Energie Atlas 24 3500 amp Atlas 24 4500 aansluit diagram artikel AANSSCORON 42 f victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing Atlas 24 3500 24 4500 gebruiksaanwijzing My victron energie 43
5. omvormer is tegen kortsluiting beveiligd De kortsluitstroom is afhankelijk van het type zie hiervoor hoofdstuk 6 Nadat de kortsluiting wordt opgeheven werkt de omvormer weer volgens de geldende specificaties Het is daarom niet noodzakelijk een zekering op te nemen in het uitgangscircuit van de omvormer 28 f victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing Vermogensbeveiliging De omvormer kan tijdelijk een hoger vermogen afgeven dan het continu vermogen Wordt er voor langere tijd meer vermogen gevraagd dan zal de omvormer afschakelen op zijn temperatuurbegrenzing Wordt er meer vermogen gevraagd dan de omvormer kan leveren dan zal de omvormer begrenzen op zijn maximaal vermogen Temperatuurbeveiliging De interne temperatuur van de omvormer wordt continu gemeten Als de interne temperatuur te hoog is opgelopen bijvoorbeeld door een extreem hoge omgevingstemperatuur schakelt de omvormer automatisch uit en gaat de temp led branden Zodra de temperatuur voldoende is gedaald start de omvormer weer op Ingangsspanningsbeveiliging Zodra de ingangsspanning een te lage waarde bereikt wordt de omvormer automatisch uitgeschakeld en de low batt led gaat branden De omvormer start automatisch op wanneer de ingangsspanning voldoende is gestegen Zodra de ingangsspanning een te hoge waarde bereikt wordt de omvormer automatisch uitgeschakeld en de high batt led gaat branden De omvormer start automatisch op wan
6. 6 4 Afmetingen 41 6 5 Aansluitschema 42 Atlas 24 3500 24 4500 gebruiksaanwijzing MO victron energie 25 1 INLEIDING 1 1 Victron Energie Victron Energie is internationaal bekend door het ontwerpen en het fabriceren van elektrische energievoorzieningssystemen Dit is te danken aan de voortdurende aandacht die de ontwikkelingsafdeling besteedt aan productonderzoek en het toepassen van nieuwe technologie n in haar producten Victron Energie systemen zorgen voor een kwalitatief hoogwaardige energie voorziening op plaatsen waar geen permanente aansluiting op het elektriciteitsnet aanwezig is Een stand alone automatisch werkend energievoorzieningssysteem kan bestaan uit Een Victron Energie omvormer een Victron Energie acculader eventueel een Victron Energie Mains Manager en accu s met voldoende capaciteit 1 2 De Atlas 24 3500 amp 24 4500 omvormer Deze handleiding beschrijft de installatie de werking en de praktische toepassing van de Atlas omvormer Bovendien wordt in deze handleiding ingegaan op de beveiligingsvoorzieningen en de technische specificaties van de omvormer 1 3 Waarschuwingen Er staat een gevaarlijke spanning op sommige metalen WARNING delen van de componenten in de omvormer De omvormer is NIET beveiligd tegen ompoling van de aangesloten accu aangesloten op en aangesloten op Volg de aansluitprocedure De fabrieksgarantie vervalt wanneer er door ompoling een WARNING defect aan d
7. Volg de aansluitprocedure De WARNING fabrieksgarantie vervalt wanneer er door ompoling een defect aan de omvormer is ontstaan De aansluitingen tussen de accu en de omvormer zijn uitermate belangrijk voor de goede werking van de omvormer Draai daarom de kabelverbindingen goed aan en let op dat er geen trekkracht op de kabels en de aansluitklemmen staat Gebruik zo kort en zo dik mogelijke kabels om het spanningsverlies tussen de omvormer en de accu tot een minimum te beperken Hoe korter en dikker de kabels zijn des te geringer is hun weerstand Kabels langer dan 6 meter worden afgeraden Onderstaande tabel geeft het aanbevolen minimum doorsneden voor de koperkern van de accukabels Atlas 24 3500 24 4500 gebruiksaanwijzing MO victron energie 31 Atlas 24 3500 Atlas 244800 korter dan 1 5 meter 50 mm 70 mm Het is verplicht om bij de accu aansluiting een zekering op te nemen die groter is dan 600A 80V traag De accu aansluitingen bevinden zich op de printplaat in de omvormer zie afbeelding 4 De accu moet als volgt op de accu aansluitingen aangesloten worden Controleer of de accukabels nog niet aangesloten zijn op de accu Controleer of de omvormer uitgeschakeld is Controleer of de zekering en niet op de printplaat aanwezig zijn Sluit de positieve accukabel rood op de positieve omvormeraansluiting aan Sluit de negatieve accukabel zwart op de negatieve omvormeraansluiting aan Sluit de positieve
8. aai de vier schroeven aan de voorzijde van de behuizing los zie afbeelding 1 e Schuif het front van de behuizing voorzichtig weg e De aansluitpunten bevinden zich op de printplaat in de omvormer zie afbeelding 2 gt victron energie e INVERTER e ATLAS 245 ce EJ Afbeelding 1 e Afbeelding 2 aard afstandsbediening accu aansluiting aansluiting AC uitgang 30 f victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing Aansluiten van de aardverbinding ZN In verband met veiligheid moet de behuizing van de omvormer geaard zijn WARNING De behuizing van de omvormer is aan de onderzijde voorzien van een aardschroef zie afbeelding 3 De aansluiting is als volgt e Monteer het meegeleverde kabelschoentje aan een kabel met Aardschroef een aderdoorsnede van 2 5 mm e Schroef de kabel met het kabelschoentje aan de aardschroef e een boot verbind het andere eind van de kabel met de aardplaat of de scheepshuid e Aan land verbind het andere eind van de kabel met de aarde van het elektriciteitsnet e Bij mobiele toepassingen auto caravan etc verbind het andere Afbeelding 3 eind van de kabel met het chassis van het voertuig Aansluiten van de accu De omvormer is NIET beveiligd tegen ompoling van de aangesloten accu aangesloten op en aangesloten op
9. anwijzing victron energie 33 3 2 Bediening Op het front van de Atlas omvormer bevinden zich een schakelaar en zes led s zie afbeelding 5 O auto De on off auto schakelaar O overload Met de on off auto schakelaar kan de omvormer high batt worden aangeschakeld on led of in de O ow bett automode worden geschakeld auto led en temp worden uitgeschakeld on Wanneer de schakelaar op auto staat en er is z off geen belasting aanwezig zal de led auto aan auto gaan De omvormer zal inschakelen zodra er op de uitgang een belasting van minimaal 10 Watt wordt Afbeelding 5 ingeschakeld De overload led Wanneer de omvormer overbelast wordt of als de ingangsrimpelspanning te hoog wordt gaat de led overload knipperen Na een aantal seconden afhankelijk van de mate van overbelasting zal de omvormer uitschakelen Na 35 seconden schakelt de omvormer weer aan Is de foutsituatie dan niet opgeheven dan wordt bovenstaande herhaald De low batt led De led low batt licht op wanneer de ingangsspanning te laag is De omvormer zal dan meteen afschakelen en zal weer opstarten zodra de ingangsspanning voldoende is gestegen Een te lage ingangsspanning wordt veroorzaakt door e HRenlege accu e Een relatief lage accucapaciteit in vergelijking tot de hoge accubelasting als gevolg waarvan de klemspanning aanmerkelijk daalt e Onvoldoende accucapaciteit in vergelijk
10. e indien nodig De omvormer staat niet aan Zet de schakelaar op on Er is te veel belasting op de Verwijder een deel uitgang van de omvormer van de belasting aangesloten De omvormer is te warmen Laat de omvormer de temperatuur led brandt afkoelen en kijk of de ventilators draaien De uitgangsspanning De potentiometer P1 is Stel potentiometer van de omvormer is te verkeerd afgesteld P1 op de juiste hoog of te laag waarde in zie hoofdstuk 4 2 Overload led Accu s zijn te klein of de Grotere accu s of knippert bij een te kabels zijn te lang of te dun kortere dikkere laag vermogen accukabels victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing O 6 TECHNISCHE SPECIFICATIES 6 1 Algemeen Ventilatietechniek Interne geforceerde convectie Temperatuurbeveiliging De interne temperatuur wordt continu gemeten De omvormer schakelt uit zodra de maximale temperatuur wordt overschreden Wanneer de temperatuur is gedaald schakelt de omvormer aan Emission EN 55014 1993 Immunity EN 55104 1995 Safet EN 60950 4 1991 Atlas 4500 26 80 kg Afstandsbediening Aansluitingen op printplaat met afneembare connector M4 aansluiting op bodemkast 6 2 Ingang 24 3500 24 4500 24 Vdc 24 Vde Ingangsspanning bereik 20 4 30 9 Vde 20 4 30 9 Vdc Inschakelspanning laag Inschakelspanning hoog 30 9 Vdc 30 9 Vdc Uitschakelspanning laag Uitschakelspanning hoog 32 2 Vdc 32 2 Vdc Nul
11. e foam and a rigid cardboard box The converter has a robust aluminium housing to class IP21 which is suitable for floor and wall mounting The connections are accessible from the housing s front panel The converter s type designation is made up of the following elements in the example of Atlas 24 3500 24 stands for a battery voltage of 24 volts and 3500 stands for a continuous power output of 3500 watts The converter is suitable for a battery voltage of 24 Vdc and supplies a square wave output voltage of 230Vac 50Hz 2 2 Protection devices The converter contains a number of safety features which protect the converter itself and any equipment connected to it against incorrect use Short circuit protection e The converter s output is protected against short circuits The fault current depends on the type see section 6 Once the short circuit has been removed the converter resumes operation as specified For this reason incorporation of a fuse in the converter s output circuit is unnecessary Overload protection e The converter can temporarily deliver a higher output than the continuous output If more power is demanded for an extended period the converter will shut down at its temperature threshold If more power is demanded than the converter can supply the converter will be restricted to its maximum output 8 victron energie Atlas 24 3500 24 4500 user manual y Thermal protection The internal t
12. e omvormer is ontstaan De omvormer wordt ernstig beschadigd wanneer op de 230Vac uitgang een andere wisselspanning wordt gezet bijvoorbeeld van een generator Deze WARNING _ beschadiging valt niet onder de fabrieksgarantie victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing O In verband met veiligheid moet de behuizing van de omvormer geaard zijn WARNING Atlas 24 3500 24 4500 gebruiksaanwijzing MO victron energie 27 2 BESCHRIJVING 2 1 Werking Alle Atlas omvormers worden uitgebreid getest voordat ze de fabriek verlaten Dit garandeert een correcte werking Voor het transport worden de omvormers verpakt in schokdempend polystyreenschuim en in een stevige kartonnen doos De omvormer heeft een solide aluminium behuizing beschermklasse IP21 die geschikt is voor vloer en wandmontage De aansluitingen zijn bereikbaar via de voorzijde van de behuizing De type aanduiding van de omvormer is opgebouwd uit de volgende elementen voorbeeld Atlas 24 3500 24 staat voor een accuspanning van 24 Volt en 3500 staat voor een continu uitgangsvermogen van 3500 Watt De omvormer is geschikt voor een accuspanning van 24 Vdc en levert een kanteelvormige uitgangsspanning van 230 Vac 50Hz 2 2 Beveiligingen In de omvormer zijn een aantal beveiligingsvoorzieningen ingebouwd die de omvormer zelf en de aangesloten apparatuur beschermen tegen verkeerd gebruik Kortsluitbeveiliging e De uitgang van de
13. emperature of the converter is measured continuously If the internal temperature rises too high for example because of an extremely high ambient temperature the converter automatically shuts down and the temp LED lights up The converter starts up again as soon as the temperature has fallen sufficiently Input voltage protection If the input voltage is too low the converter automatically shuts down and the low batt LED lights up The converter automatically starts up again once the input voltage has risen sufficiently If the input voltage is too high the converter automatically shuts down and the high batt LED lights up The converter automatically starts up again once the input voltage has fallen sufficiently Please refer to section 6 for the precise values If the input voltage continues to rise the converter will shut down completely to protect itself and all the LEDs will then be extinguished Ripple voltage protection In the event of excessively long battery cables or too small a battery there is a ripple voltage on the input voltage If the ripple voltage rises too high the converter will react as though the load were too high The overload LED will flash for approx 35 seconds and the converter will then shut down Atlas 24 3500 24 4500 user manual My victron energie 9 3 INSTRUCTIONS FOR USE 3 1 Installation The Atlas converter should be installed in a dry well ventilated area Ens
14. he 230Vac cable must be connected as follows e Check whether the converter is switched off e Connect the 230Vac unit to the AC connector via a three core cable with a flexible core and a core diameter of 6mm The connecting points are clearly coded From left to right live N neutral and PE earth For safety reasons the unit connected to the AC output must comply with the relevant safety requirements The converter will be seriously damaged if a different alternating current for example from a generator is connected to the 230 Vac output This damage is not WARNING covered by the factory guarantee 3 2 Operation The front panel of the Atlas converter er contains a switch and six LEDs see O ER Fig 5 overload high batt On off auto switch O low batt The on off auto switch enables the O temp converter to be switched on on o LED switched to auto mode auto z A LED and be switched off ato If the switch is turned to auto and no load is present the auto LED will light up The converter will switch on as soon as a load of at least Fig 5 10 watts is switched on at the output Overload LED If the converter is overloaded or if the input ripple voltage is too high the overload LED will flash The converter will switch off after a few seconds depending on the degree of overload After 35 seconds the converter swi
15. igh Make sure that the work when switched on jor too low input voltage is brought within the correct values see section 6 for these values The plus and the minus Switch the converter of the batteries and the off and connect the converter do not correspond battery correctly and the wrong LED is lit up Check the input fuses and replace them if necessar The converter is not on Set the switch to on Too high a load has been Remove part of the connected to the converters load output The converter is too hot and Allow the converter to the temperature LED is lit up cool down and check running The output voltage of the Potentiometer P1 is wrongly Set potentiometer P1 converter is too high or adjusted to the correct value too low see section 4 2 Overload LED flashes Batteries are too small or the Larger batteries or at too low a power cables are too long or too thin shorter thicker battery cables 18 victron energie Atlas 24 3500 24 4500 user manual Oy 6 TECHNICAL SPECIFICATIONS 6 1 General Ventilation system Internal forced convection Thermal protection The internal temperature is measured continuously The converter switches off as soon as the maximum temperature is exceeded When the temperature falls the converter switches on again 0 95 Emission AND 55014 1993 Immunity AND 55104 1995 Safet AND 60950 4 1991 Atlas 4500 26 80 kg bolts remo
16. ing tot het hoge afgegeven vermogen van de omvormer e Slechte conditie van de accu s De high batt led De led high batt licht op wanneer de ingangsspanning te hoog is De omvormer zal dan meteen afschakelen en zal opstarten zodra de ingangsspanning voldoende is gedaald Wordt de ingangsspanning nog hoger dan schakelt de omvormer helemaal uit en gaan alle led s uit 34 f victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing De temp led De temp led licht op wanneer de interne temperatuur van de omvormer te hoog is Wanneer deze situatie zich voordoet wordt de omvormer uitgeschakeld De omvormer start op zodra de temperatuur voldoende is gedaald 3 3 Onderhoud De Atlas omvormers vereisen geen specifiek onderhoud Het volstaat de elektrische verbindingen eenmaal per jaar te controleren Voorkom dat de Atlas vochtig wordt en houd de Atlas zo schoon mogelijk Atlas 24 3500 24 4500 gebruiksaanwijzing My victron energie 35 4 OPTIES 4 1 Aansluiten afstandsbediening De Atlas omvormers kunnen met behulp afstandsbediening aansluiting van de afstandsbediening worden in en uitgeschakeld De afstandsbediening kan SISSISISISSISISIS tevens worden gebruikt voor het op 10987654321 afstand aansluiten van de zes indicatie led s De draden van de afstandsbediening 555555 2 3582200248 moeten op de 662 Ege RR 27538257 afstandsbedieningsconnector worden S2 PZT aangesloten zie
17. las 24 050 A fuse which is larger than 600A 80V slow blowing must be incorporated in the battery connection The battery connections are located on the printed circuit board in the converter see Fig 4 The battery must be connected to the battery connections as follows e Check whether the battery cables are already connected to the battery e Check whether the converter is switched off e Check that the fuse s are not present on the printed circuit board e Connect the positive battery cable red to the positive converter connection e Connect the negative battery cable black to the negative converter connection e Connect the positive battery cable red to the positive battery connection e Connect the negative battery cable black to the negative battery connection e Check whether the green right LED is lit up e If the red wrong LED is lit up the battery cables are wrongly connected Change the battery cables over and check whether the green right LED is lit up e Tighten the battery connections thoroughly e Fitthe fuse s see table below 24 3500 8 x 40A 24 4500 10 x 40A 12 victron energie Atlas 24 3500 24 4500 user manual y right o wrong TERR earth battery AC Connection connection output Fig 4 Connecting the 230Vac cable The AC connection is located on the printed circuit board see Fig 4 T
18. last auto mode Ingangszekeringen 8x40 A 10x40 A Atlas 24 3500 24 4500 gebruiksaanwijzing My victron energie 39 6 3 Uitgang 50 Hz 0 5 kristalgestuurd Vermogensfactor cos phi Nominaal vermogen Atlas 3500 3500 W bij 25 C en bij nominale Atlas 4500 4500 W accuspanning Tijdelijk max vermogen Atlas 3500 4000 W gedurende 30 min bij 25 C en bij nominale Atlas 3500 4800 W gedurende 10 min accuspanning Atlas 4500 5000 W gedurende 30 min Atlas 4500 6000 W gedurende 10 min Inschakelgedrag De omvormer kan bij nominale belasting worden ingeschakeld 88 886 De Atlas omvormer is beveiligd tegen overbelasting Kortsluitstroom Atlas 24 3500 8 A De uitgang is kortsluitvast Atlas 24 4500 10 victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing O 6 4 Afmetingen an T e 7 BE LL poe Fr k 4 8 6 5mm _ 6 0 mm y y NL mm c L 270 tekeningnr ATO1003E victron energie b v Victron Atlas afmetingen datum 250398 revisienr 0002 Atlas 24 3500 24 4500 gebruiksaanwijzing MO victron energie Al 6 5 Aansluitschema lt TC afstandsbediening groene led 4 rode led US AC uitgang afstandsbediening aansluitvolgorde 1 zorg dat de zekeringen niet geplaats zijn 2 sluit
19. mote panel green led red led eee oog eee L PE S AC output remote panel connections 1098 76 4 2 _ a oo pub uo pal YIMS one UMS ome le dws pa peq mo pal L 1 pal 2 Aa ubiu pal connection sequence 1 make sure that the fuses are removed 2 connect the battery cables 3 check if the green led illuminates 4 place the fuses battery cable connections X M E 2 doc ATO81501 CI victron energie b v Victron Energie Atlas 24 3500 amp Atlas 24 4500 connection diagram article AANS3000014 22 victron energie y Atlas 24 3500 24 4500 user manual victron energie Oy GEBRUIKSAANWIJZING ATLAS 24 3500 ATLAS 24 4500 we Ce victron energie Atlas 24 3500 24 4500 gebruiksaanwijzing TQ GEBRUIKSAANWIJZING ATLAS 24 3500 24 4500 INHOUD Pagina 1 INLEIDING 26 1 1 Victron Energie 26 1 2 De Atlas 24 3500 amp 24 4500 omvormer 26 1 3 Waarschuwingen 26 2 BESCHRIJVING 28 2 1 Werking 28 2 2 Beveiligingen 28 3 GEBRUIKSRICHTLIJNEN 30 3 1 Installatie 30 3 2 Bediening 34 3 3 Onderhoud 35 4 OPTIES 36 4 1 Aansluiten afstandsbediening 36 4 2 Afregelen van de uitgangsspanning 36 5 STORINGEN 38 6 TECHNISCHE SPECIFICATIES 39 6 1 Algemeen 39 6 2 Ingang 39 6 3 Uitgang 40
20. nd alone automatic power supply system can consist of a Victron Energie converter a Victron Energie battery charger possibly a Victron Energie Mains Manager and batteries with sufficient capacity 1 2 Atlas 24 3500 amp 24 4500 converter This manual describes the installation functions and practical operation of the Atlas converter Furthermore the manual covers the converter s safety provisions and technical specifications 1 3 Warnings A dangerous voltage is present on some of the metal parts of the components in the converter WARNING The converter is NOT protected against polarity reversal of the connected battery connected to and connected to Follow the recommended connection WARNING procedure The factory guarantee is void if a fault is caused to the converter due to polarity reversal The converter will be seriously damaged if a different alternating current for example from a generator is connected to the 230Vac output This damage is not WARNING covered by the factory guarantee 6 victron energie Atlas 24 3500 24 4500 user manual y For safety reasons the converter housing must be earthed WARNING Atlas 24 3500 24 4500 user manual Mp Victron energie 7 2 DESCRIPTION 2 1 Function All Atlas converters are extensively tested before they leave the factory to guarantee correct operation For transport the converters are packaged in shock absorbing polystyren
21. neer de ingangsspanning voldoende is gedaald Zie voor de exacte waarden hoofdstuk 6 Wordt de ingangsspanning nog hoger dan zal de omvormer helemaal uitschakelen om zichzelf te beschermen alle led s zijn nu uit Rimpelspanningsbeveiliging In geval van te lange accukabels of een te kleine accu ontstaat er een rimpelspanning op de ingangsspanning Wordt de rimpelspanning te hoog dan zal de omvormer reageren alsof de belasting te hoog is De overload led gaat 35 seconden knipperen en daarna schakelt de omvormer uit Atlas 24 3500 24 4500 gebruiksaanwijzing MO victron energie 29 3 GEBRUIKSRICHTLIJNEN 3 1 Installatie Installeer de Atlas omvormer in een droge en goed geventileerde ruimte Let op voldoende ventilatie met het oog op de warmte die geproduceerd wordt door de omvormer Bij een hoge omgevingstemperatuur zal het maximaal te leveren vermogen afnemen zal het rendement lager worden en zal de levensduur korter zijn De omvormer kan alleen verticaal of liggend gemonteerd worden Het verdient echter aanbeveling het apparaat verticaal te monteren In deze positie is de koeling optimaal De omvormer is geschikt voor montage aan de wand of op de vloer De afmetingen van de omvormer en de plaats van de bevestigingsgaten staan in hoofdstuk 6 De afstand tussen de omvormer en de accu moet zo klein mogelijk zijn en mag maximaal 6 meter bedragen Om de aansluitpunten van de omvormer te bereiken moet het volgende gebeuren e Dr
22. ore diameter of 2 5 2 mm Earth screw e Screw the cable with the cable lug to the earth screw e Ona boat connect the other end of the cable to the earth plate or the hull e On land connect the other end of the cable to the earth of the electricity mains e With mobile applications car caravan etc connect the other end of the Fig 3 cable to the vehicle chassis Connecting the battery The converter is NOT protected against polarity reversal of the connected battery connected to and connected to Follow the recommended WARNING connection procedure The factory guarantee is void if a fault is caused to the converter due to polarity reversal The connections between the battery and the converter are extremely important for the correct working of the converter For this reason tighten the cable connections properly and ensure that the cables and connection terminals are not subject to tensile loads Use cables which are as short and thick as possible to minimise the voltage drop between the converter and the battery The shorter and thicker the cables the lower their resistance Cables longer than 6 metres are not advisable The table below gives the minimum recommended cross sections for the copper core of the battery cables Atlas 24 3500 24 4500 user manual My victron energie 11 Shorter than 1 5 metres 1 5 6 metres Atlas 24 3500 50 mm 70 mm A
23. tches back on If the fault has still not been rectified the above is repeated Low batt LED The low batt LED lights up if the input voltage is too low The converter will then immediately switch off and will start up again as soon as the input voltage has risen sufficiently Too low an input voltage is caused by e aflat battery e arelatively low battery capacity compared to the high battery load as a consequence of which the terminal voltage falls substantially e insufficient battery capacity compared with the converter s high output power e batteries in poor condition High batt LED The high batt LED lights up if the input voltage is too high The converter will then immediately switch off and will start up again as soon as the input voltage has fallen sufficiently If the input voltage rises even higher the converter will shut down completely and all the LEDs will go out 14 victron energie Atlas 24 3500 24 4500 user manual y Temp LED The temp LED lights up if the internal temperature of the converter is too high If this situation occurs the converter switches off It starts up again as soon as the temperature has fallen sufficiently 3 3 Maintenance These Atlas converters require no specific maintenance An annual check of the electrical connections is all that is needed Keep the Atlas dry and as clean as possible Atlas 24 3500 24 4500 user manual My victron energie 15
24. ure adequate ventilation in view of the heat produced by the converter When the ambient temperature is high the maximum power that can be supplied will decrease efficiency will be reduced and the service life shorter The converter can only be mounted vertically or horizontally It is recommended however that the unit be mounted vertically This position provides optimum cooling The converter is suitable for wall or floor mounting The converter dimensions and the positions of the attachment holes are given in section 6 The distance between the converter and the battery must be as small as possible and should not exceed 6 metres Proceed as follows to gain access to the converter connection points e Unscrew the four screws on the gt Ba front panel of the housing see on s Fig 1 e Carefully remove the front panel of the housing e connection points Arias aa ce located on the printed circuit rura board in the converter see Fig 2 we E s Il ee 119 0 lt z earth connection output attery connection Fig 2 10 victron energie Atlas 24 3500 24 4500 user manual Earth connection For safety reasons the converter housing must be earthed WARNING The converter housing has an earth screw on the underside see Fig 3 The connection is as follows e Mount the supplied cable lug on a cable with a c
25. vable connector M4 connection on base 6 2 Input 24 3500 24 4500 Input voltage nominal 24 24 Vdc Input voltage range 20 4 30 9 Vdc 20 4 30 9 Vdc Switch on voltage low Switch on voltage high 30 9 Vdc 30 9 Vdc Switch off voltage low Switch off voltage high 32 2 Vdc 32 2 Vdc No load auto mode mw 8x40 A 10x 40 A Atlas 24 3500 24 4500 user manual Mp Victron energie 19 6 3 Output 50 Hz 0 5 crystal controlled Nominal power Atlas 3500 3500 W at 25 C and at nominal Atlas 4500 4500 W battery voltage Temporary max power Atlas 3500 4000 W for 30 min at 25 C and at nominal Atlas 3500 4800 W for 10 min battery voltage Atlas 4500 5000 W for 30 min Atlas 4500 6000 W for 10 min Switch on properties The converter can be switched on at nominal load Overload protection The Atlas converter is protected against overload Short circuit current Atlas 24 3500 8A The output is short circuit Atlas 24 4500 10A proof 20 victron energie Atlas 24 3500 24 4500 user manual Oy 6 4 Dimensions 300 250 235 HP A gt 7 8 8 5 mm 8 0 mm my y victron energie b v Victron Atlas dimensions drawing no ATO1003E date 250398 revision no 0002 Atlas 24 3500 24 4500 user manual KO victron energie 21 6 5 Connection diagram A re
26. victron energie Oy USER MANUAL GEBRUIKSAANWIJZING ATLAS 24 3500 ATLAS 24 4500 gt SECTIONS ENGLISH Page 6 NEDERLANDS Pagina 26 Article no MANU0105000 Doc no 080000 Version KME 0000 05 June 1998 Subject to change without notice Wijzigingen onder voorbehoud Atlas 24 3500 24 4500 user manual My Victron energie 4 victron energie Atlas 24 3500 24 4500 user manual y ATLAS 24 3500 24 4500 USER MANUAL CONTENTS Page 1 INTRODUCTION 6 1 1 Victron Energie 6 1 2 Atlas 24 3500 amp 24 4500 converter 6 1 3 Warnings 6 2 DESCRIPTION 8 2 1 Function 8 2 2 Protection devices 8 3 INSTRUCTIONS FOR USE 10 3 1 Installation 10 3 2 Operation 14 3 3 Maintenance 15 4 OPTIONS 16 4 1 Connecting a remote control 16 4 2 Adjusting the output voltage 16 5 TROUBLESHOOTING 18 6 TECHNICAL SPECIFICATIONS 19 6 1 General 19 6 2 Input 19 6 3 Output 20 6 4 Dimensions 21 6 5 Connection diagram 22 Atlas 24 3500 24 4500 user manual Mp Victron energie 5 1 INTRODUCTION 1 1 Victron Energie Victron Energie is internationally renowned for the design and manufacture of electrical power supply systems This is due to the ongoing attention devoted by the R amp D Department to product research and the use of new technologies in its products Victron Energie systems provide high quality power supplies in locations where there is no permanent connection to the electricity mains A sta