Home
(For Inverter Models) User Manual
Contents
1. AUTO when the operating mode is either AUTO or DRY Note All indicators shown in the figure are for the purpose of clear presentation But during the actual operation only the relative functional signs are shown on the display window How to use the buttons Auto operation Ensure the unit is plugged in and power is available The OPERATION indicator on the display panel of the indoor unit starts flashing 1 Press the MODE button to select Auto 2 Press the UP DOWN button to set the desired temperature The temperature can be set within a range of 62 F 86 F in 1 F increments 3 Press the ON OFFbutton to start the air conditioner NOTE 1 In the Auto mode the air conditioner can logically choose the mode of Cooling Fan and Heating by sensing the difference between the actual ambient room temperature and the setting temperature on the remote controller 2 In the Auto mode you can not switch the fan speed It has already been automatically controlled 3 lf the Auto mode is not comfortable for you the desired mode can be selected manually Cooling Heating Fan operation Ensure the unitis plugged in and power is available 1 Press the MODE button to select COOL HEAT cooling amp heating models only or FAN mode 2 Press the UP DOWN buttons to set the desired temperature The temperature can be set within a range of 62 F 86 F in 1 F increments 3 Press the FAN button to select th
2. be cancelled if MODE FAN SPEED or ON OFF button is pressed GO TURBO Button Active Disable Turbo function Turbo function enables the unit to reach the preset temperature in the shortest time When press this button on cooling mode the unit will blow strong cooling air with super high fan speed When press this button on heating mode applicable to the unit adopts PTC only the PTC will be energized and bring fast heating operation LED Button Disable Active indoor screen Display When pushing the button the indoor screen display is cleared press it again to light the display 3 Q O UP Button A Push this button to increase the indoor temperature setting in 1 F increments to 86 F DOWN Button gt Push this button to decrease the indoor temperature setting in 1 F increments to 62 F NOTE Press and hold lt and gt buttons together for 3 seconds will alternate the temperature display between the C amp F scale SHORTCUT Button Used to restore the current settings or resume previous settings e On the first time connecting to the power if push the SHORTCUT button the unit will operate on AUTO mode 80 F and fan speed is Auto e Push this button when remote controller is on the system will automatically revert back to the previous settings including operating mode setting temperature fan speed level and sleep feature if activated And
3. described are accomplished by the indoor unit If the indoor unit has no this feature there is no corresponding operation happened when press the relative button on the remote controller Indicators on LCD Mode display Displays the current operation mode Including auto cool K dry heats Not applicable to cooling only models fan S and back to auto D Transmission Indicator This transmission indicator lights when remote controller transmits signals to the indoor unit CooL B Cir l DRY HEAT 34 Gmi Gm H FAN 3 ON OFF display Displayed by pressing the ON OFF button 2 ll er a Press the ON OFF button again to remove D on orr TIMER ON display AUTO SET TEMP Lo i Displayed when TIMER ON time is set TIMER OFF display I Displayed when TIMER OFF time is set Pi Laen Display Displayed under sleeping operation Press the SLEEP button again to remove FOLLOW ME Display on some models Displayed when FOLLOW ME function is activated Temp Timer display Displays the temperature setting 62 F 86 F When you set the operating mode to FAN no temperature setting is displayed And if in the TIMER mode shows the ON and OFF settings of the TIMER Fan speed display Displays the selected fan speed AUTO no display and three fan speed levels 38E LOW 38 MED 3 HIGH can be indicated The fan speed is
4. The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details CR082 RGS2BGEU 202055091443 20130510 AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION FOR WYE and WYB Series Mini Split Systems WB CB UB FB and WE Series Indoor Units LCD Screen Infrared Wireless Remote Controller Thank you very much for purchasing our air conditioner Please read this owner s manual carefully before using your air conditioner CONTENTS Handling the remote controller Location of the remote controller Handling the remote Controller ccsccecceseeseeeseeeeeeeeeteeeeeeeeeees 2 e Use the remote controller within a distance of 8 meters from the appliance pointing it towards the Remote controller Specifications ccccccccccceeecsesesessesssssseseseseees 3 receiver Reception is confirmed by a beep e Keep the remote controller where its signals can FUNCTION DUTCONS siriat cdasicd ic tacdesdeastbevebeacs dasisiivcaddxsdeesevixieeds 5 reach the receiver of the unit Indicators ON LOD ssccwsnisiasnnnanonsnosnssionnoieniss 7 How to use the Buttons 0 ceeeeeseseeeeeeseeeeeeeneneeeeeeenseeeneesenneeneeees 8 Auto OPO rath Mies siinsed annaia haasi cenvevena sseded oie ceteveeiseessd 8 Cooling Heating Fan operation cccccceseeeneseseereeeeeeseeeseesseeenees 8 Dehumidifying Operation cccccccsseee
5. e fan speed in four steps Auto Low Med or High 4 Press the ON OFF button to start the air conditioner NOTE In the FAN mode the setting temperature is not displayed in the remote controller and you are not able to control the room temperature either In this case only step 1 3 and 4 may be performed Q Dehumidifying operation Ensure the unitis plugged in and power is available The OPERATION indicator on the display panel of the indoor unit starts flashing 1 Press the MODE button to select DRY mode 2 Press the UP DOWN buttons to set the desired temperature The temperature can be set within a range of 62 F 86 F in 1 F increments 3 Press the ON OFF button to start the air conditioner NOTE In the Dehumidifying mode you can not switch the fan speed It has already been automatically controlled Adjusting air flow direction Use the SWING and DIRECT button to adjust the desired airflow direction 1 When push the DIRECT button the horizontal louver changes 6 degree in angle for each push 2 When push the SWING button the louver will swing up and down automatically NOTE When the louver swing or move to a position which would affect the cooling or heating effect of the air conditioner it would automatically change the swing moving direction Timer operation Press the TIMER ON button can set the auto on time of the unit Press the TIMER OFF button can set the auto of
6. eeeeeeeeeeeeeeeeeeeeeeeeeeceeeeenenees 9 e The air conditioner will not operate if curtains doors or other materials block the signals from the remote controller to the indoor unit Adjusting air flow Aire Ction cccecscccesseeeeseeeeseeeeeeeeeesseeeeeeeeeeeeas 9 Prevent any liquid from falling into the remote controller Do not expose i i the remote controller to direct sunlight or heat Timer operation nnnnannanannonnnnnnnnnannnnnnnnnnnnnnnannnnannnnnnnnannnnnnnnnnnnnnnnnnnnnnnnn 10 If the infrared signal receiver on the indoor unit is exposed to direct sunlight the air conditioner may not function properly Use curtains to SLEEP HU MCUuO Ms sen tacicevceeiexsaseesansassyanececcsuscavanesssantuainackeasiunaxtanstuseen 13 e prevent the sunlight from falling on the receiver If other electrical appliances react to the remote controller either move these appliances or consult your local dealer Replacing batteries The remote controller is powed by two dry batteries RO3 LRO3X2 housed in the rear part and protected by a cover 1 Remove the cover by pressing and sliding off 2 Remove the old batteries and insert the new batteries placing the and ends correctly 3 Reattach the cover by sliding it back into position NOTE When the batteries are removed the remote controller erases all progra mming After inserting new batteries the remote controller must be reprogrammed A CAUTIONS e Do not mix old and new ba
7. f time of the unit To set the Auto on time 1 Press the TIMER ON button The remote controller shows TIMER ON the last Auto on setting time and the signal H will be shown on the LCD display area Now it is ready to reset the Auto on time to START the operation 2 Push the TIMER ON button again to set desired Auto on time Each time you press the button the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours 3 After setting the TIMER ON there will be a one second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal h will disappear and the set temperature will re appear on the LCD display window To set the Auto off time 1 Press the TIMER OFF button The remote controller shows TIMER OFF the last Auto off setting time and the signal H will be shown on the LCD display area Now it is ready to reset the Auto off time to stop the operation 2 Push the TIMER OFF button again to set desired Auto off time Each time you press the button the time increases by half an hour between 0 and 10 hours and by one hour between 10 and 24 hours 3 After setting the TIMER OFF there will be a one second delay before the remote controller transmits the signal to the air conditioner Then after approximately another 2 seconds the signal H will disappear and the set temperature will re appear on the LCD di
8. g E 2A 1 Press the TIMER ON button Set gt hours later 5 hours later 2 Press the TIMER ON button again to display e reg WEIN 2 0H on the TIMER ON display 3 Press the TIMER OFF button 4 Press the TIMER OFF button again to display 5 0H on the TIMER OFF display 5 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON OFF indicator remains on and this function is activated NOTE The timer setting TIMER ON or TIMER OFF that in sequence occurs directly after the set time will be activated first SLEEP function l The sleep function enables the unit to automa tically increase cooling or decrease heating 2 F per hour for the first two hours then hold steady for the next 5 hours after that the unit will stop operation It can maintain the most comfortable temperature and save energy NOTE The SLEEP function is only available under Cooling Heating and AUTO operations
9. splay window 21 22 23 and 24 e The effective operation time set by the remote controller for the timer function is limited to the following settings 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 5 5 6 0 6 5 7 0 7 5 8 0 8 5 9 0 9 5 10 11 12 13 14 15 16 17 18 19 20 Example of timer setting Start Set 6 hours later TIMER ON Auto on Operation The TIMER ON feature is useful when you want the unit to turn on automatically before you return home The air conditioner will automatically start operating at the set time Example To start the air conditioner in 6 hours 1 Press the TIMER ON button the last setting of starting operation time and the signal H will show on the display area 2 Press the TIMER ON button to display 6 0H on the TIMER ON display of the remote controller 3 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON indicator remains on and this function is activated Set 10 hours later Start Set 2 hours later 10 hours later after setting after setting TIMER OFF Auto off Operation The TIMER OFF feature is useful when you want the unit to turn off automatically after you go to bed The air conditioner will stop automatically at the set time Example To stop the air conditioner in 10 hours 1 Press the TIMER OFF button the last setting of s
10. topping operation time and the signal H will show on the display area 2 Press the TIMER OFF button to display 10H on the TIMER OFF display of the remote controller 3 Wait for 3 seconds and the digital display area will show the temperature again The TIMER OFF indicator remains on and this function is activated COMBINED TIMER Setting both ON and OFF timers simultaneously TIMER OFF TIMER ON On Stop Start operation This feature is useful when you want to stop the air conditioner after you go to bed and start it again in the morning when you wake up or when you return home Example To stop the air conditioner 2 hours after setting and start it again 10 hours after setting 1 Press the TIMER OFF button 2 Press the TIMER OFF button again to display 2 0H on the TIMER OFF display Press the TIMER ON button 4 Press the TIMER ON button again to display 10H on the TIMER ON display 5 Wait for 3 seconds and the digital display area will show the temperature again The TIMER ON OFF indicator remains on and this function is activated oO e TIMER ON gt TIMER OFF O on Qorr Off gt Start s Stop operation lt T This feature is useful when you want to start b gt 4 Li the air conditioner before you wake up and al M rm stop it after you leave the house Stn Example y To start the air conditioner 2 hours after setting off J Stop and stop it 5 hours after settin
11. transmit the signals to the unit e If push this button when remote controller is off the system will only resume the previous settings and will not transmit the signals to the unit And the sleep feature is disable If pushing more than 2 seconds the system will automatically restore the current operation settings including operating mode setting temperature fan speed level and sleep feature if activated TIMER ON Button Press this button to initiate the auto on time sequence Each press will increase the auto timed setting in 30 minutes increments When the setting time displays 10 each press will increase the auto timed setting 60 minutes increments To cancel the auto timed program simply adjust the auto on time to 0 0 Q TIMER OFF Button Press this button to initiate the auto off time sequence Each press will increase the auto timed setting in 30 minutes increments When the setting time displays 10 each press will increase the auto timed setting 60 minutes increments To cancel the auto timed program simply adjust the auto off time to 0 0 DIRECT Button Used to change the louver movement and set the desired up down air flow direction The louver changes 6 in angle for each press SWING Button Used to stop or start horizontal louver auto swing feature NOTE e Buttons design might be slightly different from the actual one you purchased depending on individual models e Allthe functions
12. tteries or batteries of different types e Do not leave the batteries in the remote controller if they are not going to be used for 2 or 3 months e Do not dispose batteries as unsorted municipal waste Collection of such waste separately for special treatment is necessary Q Function buttons Remote Controller Specifications ON OFF Button Operation starts when this button is pressed and stops when this button is pressed again Model RG52B BGEU MODE Button Rated Voltage 3 0V Dry batteries RO3 LR03 x 2 Each time the button is pressed the operation Signal Receiving 8 mode is selected in a sequence of following Range m Taia gt COOL gt DRY HEAT FAN Environment 23 F 140 F NOTE Please do not select HEAT mode if the machine you purchased is cooling only type Heat mode is not supported by the cooling only appliance Performance Feature 1 Operating Mode AUTO COOL DRY HEAT and FAN 2 Timer Setting Function in 24 hours 3 Indoor Setting Temperature Range 62 F 86 F 4 Full function of LCD Liquid Crystal Display FAN Button Used to select the fan speed in four steps t AUTO LOW MED HIGH 7 SLEEP Button Active Disable sleep function It can maintain the most comfortable temperature and save energy This function is available on COOL HEAT or AUTO mode only NOTE While the unit is running under SLEEP mode it would
Download Pdf Manuals
Related Search
Related Contents
PACKB.FL WLAN 230 AP 802-11 RESSOURCES FLASH MANUAL DE USUARIO COOPERATIVAS SRI 1. Ingrese a la página DP-2100 MANUEL D`UTILISATION 6220 User`s Manual USB対応 放射線検知器 CPI-UR001 ユーザーズマニュアル Estime de soi & matu.. - ACP Pratique et recherche BFP-A6079-0095-A Copyright © All rights reserved.
Failed to retrieve file