1. TRACEABLE TRIPLE PURPOSE TIMER INSTRUCTIONS SPECIFICATIONS Display high 5 digit LCD Timing capacity 9 hr 59 min 59 sec Resolution 1 sec Accuracy 0 01 Alarm 1 min audible visible Size Weight 3 x 2 x 1 inch 2 oz Features Count up stopwatch timing countdown alarm timing time of day clock 12 24 hour formats CLEARING THE DISPLAY TO ZERO Press CLEAR button to reset display to zero In Timing mode CLEAR operates only if the timer is stopped If the unit is timing press START STOP button to stop the timer before clearing display CLOCK SETTING 1 Press and hold CLOCK button for 3 seconds Bottom left cursor blinks 2 Press AM PM button to select the proper setting 3 Enter correct time all six digits using 0 9 buttons Example If time is 4 46 18 press 0 4 4 6 1 8 Clock is set once the last digit is entered If an incorrect time is entered press CLEAR button to clear the display 4 Choose AM PM or military time by pressing 12HR 24HR button located on back of unit COUNT UP TIMING 1 Press COUNT UP button COUNT UP appears on display 2 Press START STOP button to begin count up 3 Press START STOP button again to stop count up see Time Out section 4 With count up stopped press CLEAR button to return the display to 0 00 00 COUNTDOWN TIMING 1 Press TIMER button TIMER appears on display If necessary CLEAR the display Enter desired countdown time using buttons 0 9 Pres
2. s START STOP button to begin countdown Press START STOP button again to stop timing see Time Out section When timer reaches 0 00 00 it alarms the display flashes and begins counting up to track elapsed time since alarming 7 When the alarm sounds pressing the START STOP button silences the alarm stops the count up and returns the display to the previously programmed time Must be in Timer mode to halt count up and to return display to the preset time NOTE Alarm sounds for 1 minute then stops automatically unless turned off manually The count up continues until turned off oom Fr Ww PY TIME OUT If a pause in the countdown or count up timing operation is required press the start stop button to freeze the display at the current reading time out To resume timing at the point it was stopped press the start stop button again An unlimited number of time outs may be performed ALL OPERATIONAL DIFFICULTIES If this timer does not function properly for any reason please replace the battery with a new high quality battery see Battery Replacement section Low battery power can occasionally cause any number of apparent operational difficulties Replacing the battery with a new fresh battery will solve most difficulties BATTERY REPLACEMENT A faint display incorrect display erratic display or no display are all indicators that the battery must be replaced On back of unit slide open the battery cover Remove
3. the exhausted battery and replace with a new AAA alkaline battery For proper placement see drawing located inside battery compartment Replace battery cover Equivalent replacement battery Control No 1105 WARRANTY SERVICE OR RECALIBRATION For warranty service or recalibration contact CONTROL COMPANY 4455 Rex Road Friendswood Texas 7 546 USA Ph 281 482 1714 Fax 281 482 9448 E mail sales control3 com www control3 com Control Company is ISO 9001 Quality Certified by DNV and ISO 17025 accredited as a Calibration Laboratory by A2LA Control Company Cat No 5027 Traceable is a registered trademark of Control Company 2005 Control Company Rev 1 102904

Download Pdf Manuals

image

Related Search

Related Contents

手すりの取り付け(手すりがある場合のみ) 取り付け完了後の  Manuel d`utilisation    NOTICE D`INSTRUCTIONS NITRO 4  User`s manual  Samsung AR12JSFSBURN Manual de Usuario  TOSTAPANE  加温加湿器の使い方 - フィリップス・レスピロニクス合同会社  micon, 3 MB  CHRONOMETRE 100 LAP Manuel d`utilisation  

Copyright © All rights reserved.
Failed to retrieve file