1. high temperature environment Installed the camera away from stoves or other heat generating devices as the high temperature could cause deformation discoloration or other damages of the camera Install the camera at where the temperature range will stay between 40 C to 50 C 3 Never face the camera toward the sun Never aim the camera at the sun or other extremely bright objects whether it is 1n use or not 4 Cleaning Do not touch the surface of CCD sensor by hand directly Use a soft cloth to remove the dirt from the camera body Use lens tissue or a cotton tipped applicator and ethanol to clean the CCD sensor and the camera lens When the camera is not in use put the cover cap on the lens mount 5 Heater Heater elements could be very hot Heaters are located inside the camera housing and will active automatically while the environment temperature is below 10 C Do not touch the heater element while it s active Introduction The most technically advanced EHD series are the newest vandal resistant Color Rugged Dome Camera from EverFocus Electronics The Color Rugged Dome Camera can withstand a blow from a 10 pound sledgehammer and has a built in heater that allows for operation in low temperatures It is perfect for all high profile crime prone applications such as building entrances retail stores and shopping malls The extremely EHD series are unquestionably one of the world s toughest cameras and is your best
2. EHD Series La O O 1 3 Color Rugged Dome Camera User s Manual and Operation Instructions Notice This manual is presented to the users of EHD series by EverFocus Electronics Corp With years of engineering researches EverFocus has spared no effort to provide the high quality products to the worldwide users For the policy of continual product improvement EverFocus reserves the right to make changes to the product specifications and documentation without notice All the components of the products including accessories components and outlook are based on the agreements of each deals to satisfy all kinds of users Meanwhile please be advised that every step of operation must follow the instruction of this manual to keep EHD series working under the best condition Please notice that EverFocus will not be charged any claims or renewing cases resulted from inappropriate operation Table of Contents Safety Warning iia WA AN UWA SPA Installation Instructions Dip Switch Functions 0ce so Simple Instructions for the desiccant pack Safety Warning 1 Do not install the camera near electric or magnetic fields Installed the camera away from TV radio transmitter magnet electric motor transformer audio speakers because the magnetic fields generate from above devices will distort the video image 2 Do not install the camera in the
3. choice for vandal resistance Main Features amp 4 ixcellent high resolution 520TVL aevolutionary integrated 10 bit Digital Signal Processor DSP delivers excellent picture quality and performance g ow light sensitivity of O Slux F 1 2 is achieved by using the advanced 1 3 interline transfer color CCD ea he electronic shutter and AGC allow the camera to be used in environment with varying light levels AICI2V or AC24V switches automatically power supply Line Lock for AC24V gA IN Ratio reaches 48 dB or more 2 Mari focal lens available e ompact size 130 W mm x 98 9 H mm x 130 D mm 2 olycarbonate shell withstand the impact of 10 pounds sledgehammer smoke color or clear as option gA luminum die casting base smoke color or clear as option 2 ngue security screw locked e A perating temperature 40 50 C adeater triggered when temperature less than 10 C Specification U9 N Model OHQ ickup device 1 3 interline transfer color CCD NTSC 768 H x 494 V PAL 752 H x582 V Horizontal 520 TV lines 0 5lux F 1 2 gt 48dB AGC off ensitivity N ratio Ratings Up to 1 100 000 uto gt I N ON RIS Control Y on off switch on off switch on off switch for 24V AC on off switch gt 0 45 0VYp p 750hm 2VDC 10 24V AC 10 SW Max 15W when heater active thermostatically controlled Internal Sync Line lock Only AC24V 30 W mm x 98 9 H mm x 130 D m
4. e adjustment screw is located on the termination board The vertical phase may require adjustment to synchronize the vertical phase of the camera with other camera in the system when it 1s to be used in the line lock sync mode Make the adjustment when the vertical phase of the camera does not match with other cameras 6 View Angel Adjustment The camera can be rotated 360 horizontally 140 vertical and 60 3 rd axis view angles as shown in Figure 8 Adjust the proper camera view angel as needed If a vari focal lens is used you may adjust the focus and zoom of the lens to bring the object in focus Be sure to loosen the locking screws on the lens before you do the adjustments Lens fixing Screws Figure 8 Dip Switch Functions Vari Focal Lens LL Line Lock Off On To select the sync mode between Internal Sync LL off and Line Lock LL on Set the line lock off the camera will synchronize to the internal time base Set the line lock on the camera s vertical synchronization can be driven by the AC signal in the power lines Note Line Lock sync mode operation is possible only when used with an AC power source it s not possible with a DC power source The default setting is ON AGC Automatic Gain Control Off On AGC ON The sensitivity increases automatically when light is low AGC OFF A low noise picture is obtained under a low light condition The default setting is ON BLC Back Light Co
5. ep 2 Bend the horizontal rod and fix the desiccant Step 3 Install the outer cover and tighten the EverFocus Electronics Corp Head Office 12F No 79 Sec 1 Shin Tai Wu Road Hsi Chih Taipei Taiwan TEL 886 2 26982334 FAX 886 2 26982380 www everfocus com tw USA Office 2445 Huntington Drive San Marino CA 91108 U S A TEL 1 626 844 8888 FAX 1 626 844 8838 www everfocus com European Office Albert Einstein Strasse 1 D 46446 Emmerich Germany TEL 49 2822 9394 0 FAX 49 2822939495 www everfocus de China Office Room 609 Technology Trade Building Shandgdi Information Industry Base Haidian District Beijing China TEL 86 10 62971096 FAX 86 10 62971432 www everfocus com cn Japan Office 1809 WBG MARIBU East 18F 2 6 Nakase Mihama ku Chiba city 261 7118 Japan TEL 81 43 212 8188 FAX 481 43 297 0081 www everfocus com EverFocus P N MD35G0071A
6. m Line Lock lickerless Video output ower source Power Consumption ync mode UN J QT W gt T SLA U Se 2 Q 3 7 o o a eS gt gt g H amp 02 jo gt 5 i O 3 FIP EJB JSEJ S a e Slolale 8g m o IO IS 2 oD D S zE SIS E S jo 5 T T O O Dimension Heater auto 10 C Heater optional activated temperature Operating 40 C to 50 C 20 80 temperature Weight 1 7kg Installation Instructions 1 Loosen the 4 fix screws on the housing cover by using the attached wrench Figure 1 Carefully uncap the housing cover as the direction shown below Figure 2 please pay attention not to damage the lens To remove the housing cover push the hinges to the bottom of the bracket the hinges can be easily removed from the bracket Figure 1 Figure 2 2 Remove the camera Heater Locking Screws Figure 3 To remove the camera first unplug the wire connection on the back of the camera Then loosen the 2 locking screws on the camera base push the camera base to the right toward heater direction as shown in Figure 3 remove the camera from the mounting base Reinstall the camera and the cable while the base mounting is completed 3 Mounting the base Side conduit entry Back conduit entr Conduit plug setscrew Mounting Setscrew P Mounting Setscrew aua F q Mounting Setscrew aai i Figure 4 Attach the base
7. mpensation On Normal When BLC is turned on the AGC ES and IRIS operating point is determined by averaging over the center area instead of entire field of view so that a dimly lit foreground object at center area can be clearly distinguished from brightly lit backgrounds BLC should not be used unless it is needed to compensate for back lit The default setting is Normal FL Flickerless Function On OFF When picture flicker fiercely turn FL on then the camera will stabilize the speed of electronic shutter at 1 1LOO NTSC or 1 120 PAL automatically and reduce the flicker immediately The default setting is OFF IRIS Level Adjustment Brightness Level can be adjusted from the IRIS level VR 2s Turn counterclockwise to L to get darker picture 2s Turn clockwise to H to get brighter picture IRIS ALC Adjustment To select light metering method Turn the IRIS ALC Adjustment VR counterclockwise for Average Metering Turn the IRIS ALC Adjustment VR clockwise for Peak Metering 10 Simple Instructions for the desiccant pack Due to the camera lens blurred from the humidity inside the camera The desiccant pack absorb the humidity and easy instruction as following 1 Adjust all settings first and place the desiccant pack on the horizontal rod then bend the horizontal rod and fix it 2 Install the outer cover and tighten the screws Installation steps for the EHD series Step 1 Horizontal roc St
8. to the wall or ceiling fix the base by the 4 setscrews attached in the accessory pack The dome is weighted 1 7kg please make sure if the mounting is strengthened enough to support it 1f not please reinforce the mounting according to the environment Note The diameter of the screw hole isy 4 7mm Back conduit entry PF 1 2 The camera comes with a conduit plug pre installed in the PF 1 2 conduit entry on the side The screw can be removed and installed in the back conduit entry Loosen the conduit plug setscrew as shown in Figure 5 before removing the side conduit entry PF 1 2 conduit plug Figure 5 Caution To prevent moisture leaking into the housing apply an appropriate gasket or sealant around the conduit connection 4 Re assemble Camera 1 If mounting COLOR RUGGED DOME CAMERA on the wall please to aim the Wall in line with the triangle 1 marked on the lead frame factory default Figure 6 1 A GG 35 Wall 2 If mounting COLOR RUGGED DOME CAMERA on the ceiling please to aim the Ceiling in line with the triangle 1 marked on the lead frame Figure 6 2 ed Ceiling 5 Wire Connection Termination Board Power In Alarm COM Alarm N V Phase Adjustment VR a Power In Figure 7 Connect the power supply cable AC24V DC12V video output and alarm output to the proper connectors shown as Figure 7 The V Phas