Home
User`s Manual
Contents
1. Unit mm inch No Name Description CF card access LED 1 LED lamp lit when the CF card is accessed CF card Switch for disabling the access to the CF card 2 access ewitch ON Access to the CF card enabled OFF Access to the CF card disabled 3 Eject button Button for removing the CF card Cover opening closing at CF card installation 4 CF card cover removal CF card 5 connector Connector for installing the CF card 6 Rating plate CF card unit fixing screw Mounting screw fixed with a front extension 7 unit or the GOT an example For how to install the CF card unit on GT16 refer to GT16 User s Manual 4 1 CF Card Unit Installation 1 Power off the GOT 2 Remove one of the extension unit covers of the GOT and fit the CF card unit along the gloove of the GOT case 3 Fix the CF card unit by tightening its fixing screws 2 places with a tightening torque of 0 36 to 0 48Nem 4 2 Installation and Removal Precautions 1 Any extension units cannot be installed on the CF card unit When installing other extension units install the CF card unit at the last 2 When installing the CF card unit on extension interface 1 left side do not install more units on extension interface 2 right side than on extension interface 1 left side If doing so the CF card cannot be installed or removed 3 When removing the CF card unit de
2. Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd Singapore Thailand Indonesia 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Australia Electronic Sadan NO III Unit No15 M 1 D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 A MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Ministry lof Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan
3. MITSUBISHI GT15 CF card unit User s Manual GT15 CFCD Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed Installation precautions lt amp DANGER Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause the unit to fail or malfunction Be sure to shut off all phases of the external power supply of the GOT main unit before connecting the cable to this unit Not doing so can cause the unit to fail or malfunction A CAUTION Use this unit under the environment specified in GT16 User s Manual or GT15 User s Manual Otherwise it may cause electric shocks fires malfunctions product deterioration or damage When installing this unit fit it to the connection interface of the GOT and tighten the mounting screws If the screw is too loose it may cause a drop of the unit a failure or malfunctions Tightening the screw excessively may damage the screw and or the unit resulting in a drop of the unit a failure or malfunctions When installing a CF card into this unit insert it into the card slot of this unit until the CF card eject button pops out Failure to do so may cause a malfunction due to poor contact Before inserting or removing a CF card into from this unit turn A CAUTION Do not disassemble or modify this unit and CF card Doing so can c
4. ause failure malfunctions personal injuries and or a fire Do not touch the conductive and electronic parts of this unit directly Doing so can cause a unit malfunction or failure Do not drop or apply strong impact to this unit or the CF card Doing so may damage the unit or CF card Before handling this unit touch a grounded metal object to discharge the static electricity from the human body Failure to do so may cause failure or malfunctions of the unit Disposal precautions A CAUTION When disposing of the product treat it as an industrial waste Transportation precautions A CAUTION Make sure to transport this unit in the manner it will not be exposed to the impact exceeding the impact resistance described in the general specifications of GT16 User s Manual or GT15 User s Manual as it is a precision device Failure to do so may cause the unit to fail 1 OVERVIEW This User s Manual describes the GT15 CF card unit hereinafter abbreviated as CF card unit For the GOTs to which the units can be installed and usable CF cards refer to GT16 User s Manual or GT15 User s Manual When using an additional drive the CF card unit can be used as the B drive of the GOT The extension units used as the B drive of the GOT are a CF card unit and a CF card extension unit The CF card unit and the CF card extension unit cannot be used at once To use the CF card unit make the Communication Settings For s
5. esult in an electric shock product damage A CAUTION Carefully prevent foreign matter such as dust or wire chips from entering this unit Failure to do so may cause a fire failure or malfunctions Startup and maintenance precautions MANUALS The following shows manuals relevant to this product Detailed Manual Manual number Manual name Model code GT16 User s Manual SH 080778ENG Relevant Manuals For relevant manuals refer to the PDF manuals stored in the GT Designer2 CD ROM a ndicates that incorrect handling may cause af O DANGER 2000 MITSUBISHI ELEC RIG CORPORATION i O DANGER hazardous conditions resulting in death or severe injury l Be sure to shut off all phases of the external power supply of the Compliance with the EMC and Low Voltage p l GOT main unit before starting cleaning Directives ndicates that incorrect handling may cause Not doing o can calise the unit to Tall ormabunction When incorporating the Mitsubishi GOT into other machinery or i A CAUTION hazardous conditions resulting in medium or i equipment and keeping compliance with the EMC and low voltage enn Slight personal injury or physical damage _ directives refer to EMC Directives and Low Voltage Directives of GT15 User s Manual The CE logo is printed on the rating plate of the GOT indicating compliance with the EMC and low voltage directives Under some circumstance
6. etting details refer to GT16 User s Manual or GT15 User s Manual 2 SPECIFICATIONS The performance specifications of the CF card unit are shown below Item Specifications manual thoroughly to fully understand the product Internal current consumption 5VDC 0 07A Check if the unit operates correctly after transportation the CF card access switch off Failure to do so may corrupt data on the CF card When removing a CF card from the GOT support it by hand as Protective structure IP2X MODEL GT15 CFCD U Weight 0 15kg 0 33lb Before using this prod MODEL CODE 1D7M62 IB NA 0800365 D 0811 MEE GRAPHIC OPERATION TERMINAL GOTio900 or malfunctions Sold separately 1D7M88 SAFETY PRECAUTIONS GT15 User s Manual SH 080528 Sold separately 1D7M23 Be sure to read these instructions before use and handle the product correctly with full attention to safety Note that these precautions apply only to this product In this manual SAFETY PRECAUTIONS are classified into 2 levels DANGER and CAUTION uct read this and relevant manuals carefully it may pop out Failure to do so may cause the CF card to drop from the unit resulting in a damage or failure Wiring precautions lt amp DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may r
7. n Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Germany Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch South Africa Hong Kong 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel 852 2887 8870 China Mitsubishi Electric Automation Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd
8. s failure to observe the N CAUTION level instructions may also lead to serious accidents Be sure to observe the instructions of both levels to ensure the safety Please keep this manual in a safe place for future reference and also Model name Product name Quantit pass this manual on to the end user y CF card unit 1 GT15 CFCD Screw set 2 screws 1 Packing List The following items are included For the general specifications of the CF card unit refer to GT16 User s Manual or GT15 User s Manual 3 PART NAMES AND EXTERNAL 4 INSTALLATION PROCEDURE 5 CF CARD INSTALLATION REMOVAL WARRANTY Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary DIMENSIONS PROCEDURE The following shows how to install the CF card unit on GT15 as 0 07 63 __ 30 1 3 0 05 7 X 85 i 0 33 W 11 5 0 45 1 3 i 105 4 13 63 2 48 2 43 1 69 5 1 8 2 48 1 18 0 31 Unit mm inch Dimensions of X when installing the unit on the GOT 15 18 5 0 73 12 1 17 0 67 20 0 79 17 0 67 20 0 79 22 0 87 10 4 8 4 5 7
9. tach it from the specified direction amp drtrianglePULL so as not to break the connector 5 1 Installation Open the CF card cover and turn off the CF card access switch of the unit 2 Insert the CF card into the CF card connector with the face out af 3 Turn on the CF card access switch 5 2 Removal 1 Open the CF card cover Turn off the CF card access switch and check that the CF card access LED turns off When the CF card access LED turns off the CF card can be removed even while the GOT power is on 2 Press the CF card eject button to pop out the CF card and remove it damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties Z FOR SAFE USE This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under strict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel U S A Mitsubishi Electric Automatio