Home

User Manual

image

Contents

1. button is pushed Control Panel failure code shows E6 Control Panel failure code shows E5 Control Panel failure code shows Hl Chapter 4 Troub POSSIBLE CAUSE Power supply voltage is not within the specified range Power cord disconnected Water tank full indication lamp blinking Tank is full or in a wrong position Temperature of room above 95 F or below 40 F Air filter clogged Intake duct obstructed Discharge duct is obstructed Fan not operating Unit tilted or unsteady Air filter clogged Fan is loose or obstructed No electricity is supplied The main board is defective Temperature sensor is broken Humidity sensor is broken The main board is broken leshooting SOLUTION Check power supply voltage Ensure it is between AC110 120V 60Hz Plug power cord into outlet Empty water in drainage tank Protection device is activated Try again when room space temperature is between 40 F 95 F Clean air filter as instructed under Cleaning the dehumidifier Remove obstruction from intake duct Remove obstruction from discharge duct Replace fan assembly Move unit to a stable sturdy location Clean air filter as instructed under cleaning the dehumidifier Secure fan wheel or remove obstruction A Verify power to the outlet B Verify unit is plugged in Replace the main board Replace with new temperature sensor Replace a new humidity
2. sensor Replace with a new main circuit board IDEALair PROBLEM Control Panel makes a beeping sound Fan indicator light does not illuminate Compressor does not run Otherwise unit has power Compressor stops and starts repeatedly Unit does not dehumidify POSSIBLE CAUSE The control board is broken The room temperature is below the low limit 40 F or above the high limit 95 F Fan is broken Possible refrigerant leak Bad compressor The compressor start capacitor has failed Main board has failed SOLUTION Replace with a new control board Unit will work again when the room temperature is above the low limit temperature 40 F and below the high limit 95 F Replace fan assembly Check unit for signs of a leak Look for an oily residue in the unit Contact qualified technician for repair Replace compressor Contact qualified technician for repair Replace run capacitor Replace main board IDEALAIF 180pints 86 F 80 RH Moisture removal pints day 108pints 80 F 60 RH Rated Voltage 115V 1 phase 60HZ Power consumption 1350W Current 12 5A Applied Temperature 45 F 105 F Add Input Capacity IDEALair aM Chapter6 Warranty All Ideal Air Products come with a limited 1 year warranty At our option we will either repair or replace any Ideal Air Dehumidifier that fails in the first 12 months from a manufacture defect For a complete Lim
3. COMMERCIAL GRADE 180 Pint Commercial Dehumidifier User Manual IDEALair DEHUMIDIFIER User Manual Thank you for choosing our dehumidifiers This owners manual will provide you with valuable information necessary for the proper care and maintenance of your new dehumidifier Please take a few minutes to read the instructions thoroughly and familiarize yourself with all the operational aspects of this dehumidifier LLI Chapter 1 Precautions For your safety and service life of dehumidifier please observe all of the precautions listed below da e Do not use if there is damage fa e Do not crimp clamp or to the power cord Do not plug stress the power cord into wall e Do not set dehumidifier directly in front of the windows to avoid getting wet bv rain e Do not set dehumidifier on uneven ground e Do not set the dehumidifier near a heat source or allow direct heat onto the unit e Do not use chemical or corrosive object on dehumidifier je EF e Do not wash or soak e Do not spill liquid on the the dehumidifier dehumidifier e Do not put hands or fingers into the air outlet frame or heat exhaust holes e Plug directly into a grounded outlet do not use multi outlet adapters e Do not disassemble the unit or component parts unless directed to do so by a qualified f Tech
4. ited Warranty Description go to www Ideal Air com IMPORTANT Product Defect Not working properly DO NOT return this product to the store where you purchased it Contact Ideal Air Support directly at support ideal air com or 8 7 943 3251 For answers to the most common questions and a complete technical support library please visit at www ideal air com
5. nician e Keep children away IDEALair 1 1 Prior to Operation Warning Before usage the dehumidifier should be set upright for at least 2 hours e The dehumidifier is powered by AC 110V 60Hz To avoid damage on to the dehumidifier only plug into a 110 volt outlet e Do not disassemble the case and other covers of the dehumidifier incl air outlet front plate etc If service is needed it should be performed by a qualified service technician e Always plug into a grounded outlet e Keep children away from the dehumidifier 1 2 Proper Care and Daily Maintenance e Clean surfaces with a soft cloth do not use solvents gasoline or a strong detergent Hand wipe only Do not immerse in water e f water enters the dehumidifier unplug the unit and allow it to dry thoroughly Contact a qualified service professional to evaluate before operation e Check and clean the filter prior to every use At minimum clean monthly e Do not use the dehumidifier around flammable liquids Function key 1 ON OFF Press once to turn the dehumidifier on or off 2 SET A To set humidity e Press SET once to enter into a humidity setting mode e Press each time to add 1 humidity press each time to reduce 1 humidity B To set auto turn on or off Turn unit on e Press SET twice to enter into a time setting mode time on Will flash for 5 seconds e Press SET once to set auto turn on or
6. twice to set auto turn off timing off will flash on the screen for 5 seconds e Press each time to add 1hour or press each time to add 1 minute 3 CONT For continuous operation press the CONT button CONT will show on the display panel Push again to turn off continuous operation IDEALair 4 Automatic Defrost Mode When running the dehumidifier below 59 F frost will form on the evaporator coil The unit will automatically go into defrost mode and melt any ice build up LED display 1 LED shows the present humidity level 2 E6 Code Temperature sensor fault 3 E5 Code Humidity sensor fault Unit Diagram Control Panel Back Handle Air Outlet Side Handle Air Inlet Filter Wheel Drain Line IDEALAN Continuous drainage Proper drain line installation Correct way direct downwards Wrong being twisted Maintenance amp Storage WARNING Before performing any maintenance unplug the unit 1 Normal Maintenance Clean the unit with soft cloth Do not use liquids or harsh detergent 2 Maintenance of the Filter The filter should be cleaned prior to each use and at least monthly To clean put filter in clean water and then dry it 3 Storage Store in a dry and cool place STEP IDEAIA LI PROBLEM Burning smell and or no display Unit doesn t operate No airflow Operation is noisy Unit does not respond when ON