1. 310 0280X Read the complete manual before attempting installation and activating the system 1 DESCRIPTION This flush mounting push button dimmer with reverse phase control has a maximum load of 100W and is suitable for dimming Philipse LED fixtures see 3 4 and dimmable economy lamps Remote control via N O contacts Maximum of 30 non illuminated push buttons in parallel 2 INSTALLATION AND CONNECTIONS To connect the load and the necessary power supply voltage see the wiring diagrams below gt To regulate the minimum level in cases of incorrect light output see For installation see gt 3 OPERATION AND USE 3 1 Normal operation Remote control unit via N O contacts not illuminated Press briefly to switch on and off Hold down to dim up and down When holding down the dimming direction is switched after each interruption dimming up gt stop gt dimming down gt stop gt dimming up gt etc Once the maximum intensity has been reached the dim ming level remains unchanged The last dimming level reached before the dimmer is switched off is saved in a memory 3 3 Up to 30 N O contacts 170 00000 can be connected in parallel max distance 100 m The push buttons are not galvanically isolated 3 2 The dimmer works according to the reverse phase control principle 3 3 Memory function The dimmer can be used with or without memory The standard setting of the dimmer is without memory function To change this
2. Electronic transformers Halogen 230 V See table below Fig 1 4 TROUBLESHOOTING Possible causes of dimmer malfunction the dimmer is switched off the load is not dimmable in reverse phase control the mains voltage is not connected the load is not connected or is too high the lamp or the cable used is defective the connected load is not suitable e g a ferromagnetic transformer the thermal protection has been activated acombination of the above causes Fig 1 Philipse LED fixture type 30W Philipse LED fixture type 7 5W Lamp Ei we ms ous mm ww Lalin am CC nv Niko sa niko The dimmer is equipped with thermal protection If the temperature climbs too high as a result of overloading the dimmer switches off If this happens check whether the load is too high check whether mixed loads are being used check whether the minimum dimming level is set too low for operation with memory check the ambient temperature and positioning conditions Depending on these factors the maximum connection output must be reduced as follows 10 per 5 C in excess of the ambient temperature of 35 C 25 for flush mounting in an insulated wall gypsum wood or when 2 dimmers are positioned next to one another 5 USAGE WARNINGS Control signals that are sent via the mains can interfere with the operation of the dimmer This is not a defect This dimmer produces a limited amount of heat und
3. K Niveau de variation minimum OK Mindestdimmniveau ist OK Vly Minimum dimming level OK A p S De Minimum dimniveau te hoog j di Niveau de variation minimum trop lev Mindestdimmniveau ist zu hoch Minimum dimming level too high Min level ER lo nt 310 0280X Minimum dimniveau te laag X Niveau de variation minimum trop bas Mindestdimmniveau ist zu niedrig Minimum dimming level too low MIN lt lt MAX gt MONTAGE MOUNTING 310 02800 l 310 02801 C nv Niko sa Industriepark West 40 BE 9100 Sint Niklaas Belgium tel 32 3 778 90 00 fax 32 3 777 71 20 e mail support Niko be www niko be PM310 0280XR10263
4. as to be handed over to the user It has to be included in the electrical installation file and has to be passed on to any new owners Additional copies are available on the Niko website or via the support service During installation the following has to be taken into account not limited to list below The statutory laws standards and regulations The state of the art technique at the moment of installation This user manual which must be read within the scope of each specific installation only states general regulations The rules of proper workmanship In case of questions you can consult Niko s support service or contact a registered control organisation Support Belgium Support UK 32 3 778 90 80 44 1525877707 website http www niko be htto www nikouk com e mail support niko be sales nikouk com In case of a defect you can return your product to a registered Niko wholesaler together with a clear descrip tion of your complaint Conditions of use stated defect 8 GUARANTEE PROVISIONS Period of guarantee 2 years from date of delivery The delivery date is the invoice date of purchase of the product by the consumer If there is no invoice the date of production applies The consumer is obliged to inform Niko in writing about the defect within two months after stating the defect In case of a failure to conform the consumer has the right to a repair or replacement decided by Niko free of char
5. er normal operating conditions Allow for sufficient heat dissipation do not cover the dimmer with insulating material Reaction of the device after a power failure return to the previous setting with memory without memory The dimmer is never electrically separated from the mains due to the operation of the control In other words all parts remain connected to the power even if the load e g the light is off This appliance is not suitable for controlling motors and ferromagnetic mains transformers 6 TECHNICAL DATA Power supply voltage 230V 10 frequency 50Hz Mounting This dimmer fits in a standard flush mounting box with a min depth of 40mm Weight 75g Ambient temperature Ta 35 C Designed for use in an environment with non condensing humidity No load power consumption 0 6W unloaded Maximum wire diameter per connection terminal 2 5 mm Power supply and load 2 x 1 5 mm or 1 x 2 5 mm Push button input 2 x 1 5 mm or 1 x 2 5 mm Minimum load 2W Maximum load 100W No voltage drop over the dimmer Protections thermal overload protection short circuit protection Push button controls 230 V 5 mA not galvanically isolated Max distance to the last push button 100m Complies with the EN60669 2 1 standards 7 LEGAL WARNINGS The installation has to be carried out by a qualified person and in compliance with the statutory regula tions This user manual h
6. ge Niko cannot be held liable for a defect or damage as a result of an incorrect installation improper or careless use or wrong usage or transformation of the goods The compulsory regulations of the national legislation concerning the sales of consumer goods and the protection of the consumers in the countries where Niko sells directly or via sister or daughter companies chain stores distributors agents or permanent sales representatives take priority over the rules and regulations mentioned above Key to symbols Metal filament lamps a Electronic transformers Industriepark West 40 BE 9100 Sint Niklaas Belgium tel 32 3 778 90 00 fax 32 3 777 71 20 e mail support Niko be www niko be PM310 0280XR10263 310 0280X niko gt DIMMER AANSLUITEN RACCORDEMENT VARIATEUR DIMMER ANSCHLIESSEN CONNECT DIMMER 1 bedieningspunt Meerdere bedieningspunten 1 point de commande Plusieurs points de commande 1 Bedienungspunkt Mehrere Bedienungspunkte 1 control point several control points 2 100W 230V 50Hz 2 100W 230V 50Hz CE 2 100W 230V 50Hz 100W 230V 50Hz CEBEC C CJ 170 0000X 170 0000X LLL max 30 7777 max 30 x 170 00000 x 170 00000 gt MINIMUMNIVEAU INSTELLEN R GLAGE DU NIVEAU MINIMUM MINDESTDIMMNIVEAU EINSTELLEN SETTING THE MINIMUM LEVEL ACTION CHECK CONCLUSION ACTION CHECK Dim to MINIMUM Minimum dimniveau O
7. setting dim up to the maximum light level and then hold the control button in for 10 sec After 10 sec the light dims from 100 to a lower light level to indicate that this function has been switched on After this change in light intensity immediately release the push button Repeat the procedure to deactivate the memory function This function and the last set light level is stored in a non volatile memory i e they will not be lost in the event of a power failure With the memory function the dimmer switches on for the first time at a light level chosen by the manufacturer Thereafter the dimmer switches on at the last set value TIP When using dimmable economy lamps we recommend switching off the memory function With memory Press briefly on at previous level off Hold down when off the dimmer dims up from the minimum light level When dimming up the dimmer stops at the maximum When dimming down the dimmer stops for 2 sec at the minimum and then dims back up Arenewed long press reverses the dimming direction Without memory Press briefly on at maximum off Apart from that the control is analogous to the control with memory Push button control holding down gt 400 ms brief press lt 400 ms on off dimming up dimming down 3 4 Lamps Philipse LED fixtures Ledino Roomstylers Arcitone Smartspot Lirio by Philips Topselection of Massive Dimmable economy lamps CFLi

Download Pdf Manuals

image

Related Search

310 0280X 310 280 mcc mnc

Related Contents

Manual do Usuário Nokia X Dual SIM  Release Notes  View Fancyworks Flower Tutorial (5 meg )  HYDRAGEL 3 CSF ISOFOCUSING HYDRAGEL    iLoader User`s Manual - ALTIBASE Customer Support  Cradlepoint MBR95 Network Router User Manual  User manual - EUROtronic Technology GmbH  Liquide de rinçage concentré pour le cirage des voitures  

Copyright © All rights reserved.
Failed to retrieve file