Home
PDF manual
Contents
1. ELECTRONIC MICRO ALARM myema eu Gy USER MANUAL VERSION 120412 Before putting the EMA alarm into operation please read the Enclosure 1 carefully technical and service information DEAR CUSTOMER Thank you for your purchasing EMA a revolutionary GSM security system for cars which has been developed by the Czech company FLAJZAR EMA is a miniature GSM alarm intended for any car type you do not need to assemble anything and you can move it simply from car to car The simplest GSM alarm ever EMA s aim is not to substitute expensive built in GSM alarms and satellite systems It is however an option to increase the security of your car when parking anywhere on workdays in front of shopping malls in the town streets when angling or spending a weekend in the nature A brief summary of the most significant properties and functions gt gt EMA is a unique GSM security device gt gt no assembly necessary suitable for any car type gt sensors integrated inside the alarm device gt connection of other external sensors possible gt incase of an alarm it sends SMS messages and calls up to 6 phone numbers gt easy to control by your mobile phone gt possible to monitor the position of your car b gt a stand by Li lon battery integrated in the miniature body gt easy configuration by PC ora SMS precondition a common 12V dashboard socket so called cigarette lighter connector with the ins
2. EMA gives you a short ring to confirm the activation Since this moment EMA protects your car lt lt lt j lt lt lt After your return to the car and the shock detection EMA will detect you and will start count down of the arrival time Until this point in time you must switch on the ignition After the ignition is switched on EMA is deactivated awaiting next activation l gt gt gt lt lt lt The leave and arrival times can be set up by the program EMA config see the second page of the Instructions Control option B Automatic activation and manual deactivation of the alarm Similarly to Option A EMA automatically counts down the set up time until the activation leave time after you have switched off the ignition and left the car After the countdown and activation EMA gives you a short ring to confirm the activation Since this moment EMA protects your car lt lt lt j lt lt lt Before you enter your car deactivate EMA by giving a free of charge ring from your mobile phone your mobile phone number must be saved on the EMA s phone book Control Option C Manual activation and deactivation of the alarm In this mode the activation and deactivation is controlled by the user by giving a free of charge ring or a SMS message therefore it is not as comfortable as the options A or B are The mode is suitable to secure e g the vans if it is not possible to set up a fixed tim
3. shock sensor and accelerometer cannot 100 exclude false alarms especially in rush streets of big cities or on crowded parking lots at shopping malls we offer the possibility to connect an external sensor motion detector PIR which replies only to the motion of persons Itis activated only if a person enters the car This detector can be connected to the EMA alarm device by a USB connector being permitted in the set up 9 external sensors or in the combined detection set up 11 conditioned upon shocks a person entering the car The EMA PIR sensor is a miniature device with the dimensions 25x20x20mm It can be fastened anywhere in the car we recommend to place it in the front part of the car e g between the front seats under the dashboard etc malfunction of mobile operators network a failure caused by bad installation of the product The details concerning complaints are mentioned in the purchaser s complaint rules In case of damage please lodge a complaint about the device with your purchaser or dispatch the product to the producer s address mentioned in the User Manual The up to date list of service shops please find under www myema eu When lodging a complaint please enclose the description of the defect the purchase document and the warranty card If your device does not work properly please visit the website www myema eu first on which you can find the up to date list of the most frequent troubles and their shooti
4. the internal battery effective time is extended significantly All permitted sensors except for the detection of GSM cell change are active in this mode Upon an alarm EMA switches back to the operational mode calling a set up phone number or sending a SMS message Save to device it stores all adjustments into the EMA micro alarm Operator s symbol it displays the name of the applied SIM card s operator in the alarm device Signal intensity indicator it indicates the actual GSM signal intensity Battery condition indicator it indicates the actual condition of the alarm internal battery EMA alarm versions number of the EMA alarm hardware version and number of the EMA alarm firmware version Device condition it indicates the information on EMA connection disconnection to PC EMA config v File Aboutprogram Languages Installation wizard Command to activate the device ARM F Tum OFF LED in ARM DISARM E infomation SMS Command to activate the device it allows changing the SMS text for the device remote activation CAUTION no gaps Command to deactivate the device it allows changing the SMS text for the device deactivation CAUTION no gaps Text SMS at alarm this text will be displayed in alarm SMS messages e g ALARM IN THE CAR Brightness of LED it allows changing the LEDs brightness Let us recommend you to apply the AUTO mode Turn OFF LED i
5. unauthorized changes of the data in the Warranty Card unprofessional handling with the device including the change modification of its software unprofessional repair of the device security seal damage Enclosure 1 EMA1 technical and service information Master device GSM frequency Quad band 850 900 1800 1900MHz GSM transmitting capacity Class 1 1W Class 4 2W RERNE Charging 7 16V on board network 12V max 150mA only during recharging working position Power Supply internal Li lon 3 7V capacity 320mAh Operational temperature 20 C to 70 C Operational relative humidity 35 to 85 Storage temperature 20 C to 80 C USB IN connection to PC 5V USB OUT external sensors power supply 3 5 4V max 5mA Dimensions 38x42x69mm Most common accessories for the EMA alarm device Motion sensor EMA PIR Extension cable 12V Detection range 2 meters Operational voltage 12V Detection angle 90 Cable length 2m Power supply 3 5 4V Current consumption ImA Dimension 25x20x20mm Cable length 2 meters The EMA PIR sensor and the extension cable 12V are intended to be connected and used solely alongside the EMA alarm If connected to another device the sensor or device can be damaged Neither the sensor nor the extension cable 12 V are a part of the delivery they can be purchased separately Option extension by the EMA PIR external sensor Because the nature of the integrated
6. 456789 DELETE NUMBER1 NEW PASSWORD SHOCK ON SHOCK OFF SHOCK VH SHOCK H SHOCK M SHOCK L SHOCK VL TILT ON TILT OFF TILT 2 5 TILT 5 TILT 7 5 TILT 10 TILT 12 5 TILT 15 MICROPHONE ON MICROPHONE OFF MICROPHONE VH MICROPHONE H MICROPHONE M MICROPHONE L MICROPHONE VL EXT ON EXT OFF LOCATION ON LOCATION OFF START ON START OFF START 0 5 START 1 0 START 1 5 START 2 0 START 2 5 START 3 0 START 3 5 START 4 0 DELETE ALL NUMBERS DEFAULT SETTING 012345678912345 ARM DISARM Question about the device condition condition operator signal battery car battery voltage BTS number of events Question about the actual position BTS It writes the list of alarms since the last activation It switches on the function of position monitoring BTS Information about the route list of the latest BTS s after the command WATCH It deletes the route list of the latest BTS It activates the function Reduction in consumption with disconnected power supply It deactivates the function Reduction in consumption with disconnected power supply LEDs are on in the active mode LEDs are offin the active mode It saves the phone number to Position 1 It deletes the phone number on Position 1 It changes the access password It switches on the shock sensor It switches off the shock sensor Shock sensor sensitivity Very high Shock sensor sensitivity High Shock sensor sensitivity Medium Shock sensor sensitiv
7. e for automatic activation because of frequent loading and unloading After you enter the car the sensors are activated immediately EMA is sending the alarm SMS messages and calling Therefore it is necessary to deactivate EMA by giving it a ring from your mobile phone before you enter your car your mobile phone number must be saved on the EMA s phone book Installation of the program EMA config and configuration of the device Download the configuration program EMA config on the website www myema eu Start the program installation and follow the instructions of the installation program The installation requires EMA to be connected to your PC by an USB cable included in package After the successful installation an icon appears EMA config on the desktop area by which you can start the configuration program File Aboutprogram Languages Installation wizard 5 EMA REPORT 13 A Phone numbers setting 2 phone 3 phone num 14 4 phone num 15 5 phone num 16 a i 17 Sensors setting w 18 7 Shock sens d 19 8 Voltage drop starting motor ic activati OM 9 Tit 10 E Extemal sensors 21 11 Position change GSM cell 12 E Combination detection 22 T MOBILECZ iil E File it allows storing and opening the complete set up from the file For example you can create different profiles for different cars which you can store on the disc and load them to the program EMA config Furthermore it allo
8. gs It is woken up from the stand by mode by a raised alarm 12V connection ignition switching on or connection to PC EMAswitches over to the low power consumption mode sleep mode even in case the function for the power consumption reduction is not switched on with switched off power supply This happens with the lower battery condition 25 With switching over to the low power consumption mode the battery power is extended significantly as compared with the normal mode Warranty conditions Guarantee according relevant EU regulations in the last valid wor ding furthermore completed in following text The Warranty Card must include production number of the product The guarantee cannot be acknowledged in case of a damage caused by the application which is in contradiction to the operation instruction mechanical damage of the product after direct penetration of liquids and foreign agents into the device present acids or solvents negligent handling unsuitable storage operation in rash environment use of other accessories than those allowed by the producer connection to an electrical circuit with improper parameters voltage penetration of foreign objects into the device damage by natural elements Security seal When damaged the guarantee expires type of the product sale confirmation date of the sale seal signature and address of the seller The guarantee expires in case of
9. ide diameter between 20 5 to 21 5 mm First putting into operation Insert a SIM card of your mobile phone operator with a switched off PIN code As soon as you insert it in the EMA s slot all the LEDs go on the device has been started After a while the LEDs go out and the blue LED begins to flash GSM EMA has been netted and it is ready for use Give EMA a ring from your mobile phone The device automatically saves the phone number by which you are authorized to control EMA and to which EMA will call you or send SMS messages in case of an alarm This process will be confirmed by a SMS message sent to your mobile phone BCS Since this moment EMA starts working in the basic mode set up by the producer with possible manual activation and deactivation see the control option C However if you wish to use the EMA s integrated functions in full to change the parameters to add other phone numbers or to use the comfortable automatic mode of activation and deactivation just install a simple configuration program EMA config into your PC How to download and install it see on the other side of the sheet PERC Control option A Automatic activation and deactivation of the alarm This option is the most comfortable one and recommended for common use After you switch off the ignition and you leave your car EMA automatically counts down the time until the activation leave time After the countdown and activation
10. ion when EMA informs you about an unauthorized start up of your car Tilt this function assesses the tilting of your car e g in case of a towage or wheels theft External sensors it activates the function of external sensors which can be connected to the alarm device by an USB connector optionally Position change GSM cell EMA allows to detect the change in its position for which it uses the GSM cells in its environs In case it registers a transition to another cell it sends a warning SMS Combination detection if an alarm shall be raised by the combined detection both shocks must be detected and the motion sensor must be activated within a set up time interval The time interval can be set up as an extended adjustment In this way high resistance to false alarms can be achieved Password setting here you can assign a password to give the SMS instructions and open the EMA config program Initial password 1234 To save the new password save the configuration on the device Call at alarm if you permit this option EMA will call the set up phone numbers in case of a registered alarm This function can be combined with the next option 15 Send SMS at alarm if you permit this option EMA will send you a SMS in case of a registered alarm This function can be combined with the previous option 14 Abort call after picking up in case of an alarm call if the function is permitted and some of the set up pho
11. ity Low Shock sensor sensitivity Very low It switches on the inclination sensor It switches off the inclination sensor It sets up the inclination sensor sensitivity to 2 5 It sets up the inclination sensor sensitivity to 5 It sets up the inclination sensor sensitivity to 7 5 It sets up the inclination sensor sensitivity to 10 It sets up the inclination sensor sensitivity to 12 5 It sets up the inclination sensor sensitivity to 15 It permits the tapping function It forbids the tapping function Tapping volume Very high Tapping volume High Tapping volume Medium Tapping volume Low Tapping volume Very low It permits the external sensors It forbids the external sensors It switches on the motion monitoring BTS change It switches offthe motion monitoring BTS change It switches on the start up detection except for the automatic activation mode It switches off the start up detection It sets up the start up sensitivity voltage drop It sets up the start up sensitivity voltage drop It sets up the start up sensitivity voltage drop It sets up the start up sensitivity voltage drop to 0 5V to 1V to 1 5V to 2V to 2 5V to 3V to 3 5V to 4V It sets up the start up sensitivity voltage drop It sets up the start up sensitivity voltage drop It sets up the start up sensitivity voltage drop It sets up the start up sensitivity voltage drop It deletes all set up phone numbers I
12. n ARM masking function if this function is permitted all LEDs will be switched off upon activation the alarm will be lessnoticeable Information SMS Ifthe function is permitted EMA sends an informative SMS to number 1 Master Position in case of low battery and switchover to the low power consumption mode Tilt adjustment adjustment of tilt sensor sensitivity Voltage drop adjustment adjustment of start up detection sensitivity Microphone volume adjustment of tapping volume Time of blocking min adjustment of the time during which another alarm will be blocked Time of ringing sec adjustment of the time during which EMA shall ring when informing about an alarm Time of short ringing sec the time during which EMA shall call in case it is confirming the activation by giving a ring or by automatic activation Timer of combi detection sec the time between detection by both sensors If e g shocks are detected for a set up period the detection of person s motion by a connected external sensor is expected The detection by these two sensors within a set up interval will raise the alarm Before configuration of the alarm by the EMA config program EMA must be switched on You switch on the device by inserting the SIM card Description of signalling LEDs After you switch on or reset the device all the LEDs are on If the masking function To switch off LED in case of ARM i
13. ne numbers will reply to the phone call EMA will not continue calling the other phone numbers on the list Microphone on if the function is permitted and the EMA phone number calls an authorized phone number the call will be replied after the approx third ringing and it will be possible to tap the protected space Automatic activation this function is interesting if there is a power supply connector in your car which is supplied only upon ignition switching on If you leave your car and EMA detects that the power supply does not function it starts counting down the pre set time automatically and after it elapses EMA changes over to the protection mode automatically Automatic deactivation it serves for alarm deactivation in case the 12 V voltage appears on the power supply connector If you come to your car and switch on the ignition within the set up time EMA automatically switches over from the active to the inactive condition If the voltage does not appear on the connector within the set up time interval the alarm will be raised Automatic activation confirmed by ringing the number 1 if this option and the automatic activation are permitted a ring will be given to the first number on the list Master Position as the confirmation Reducing power consumption if this function is permitted and there is no voltage on the power supply connector EMA changes automatically over to the decrease in consumption mode whereby
14. ng VERSION 120412 Stand by time When using the mode Reduction in consumption with disconnected power supply see EMA config the battery charge can keep alive even some days in the protection mode Without using the mode Reduction in consumption with disconnected power supply it keeps alive up to two days after the last full charging whereas it remains in the full mode for the first approx 12 hours then it changes over to the stand by mode switching off the GSM module The above period is not fixed it results from the charging condition battery condition and signal intensity on site The operation time depends on the battery condition its age and especially actual operational temperature In summer the battery keeps alive for longer time while in winter with low temperatures below zero its effective time can be limited for some hours only Let us recommend using the option Reduction in consumption with disconnected power supply in case of long parking and in winter see EMA config After you start up your car 12 V connection EMA wakes up from the stand by mode The set up sensors remain active for the entire period even in the stand by mode After sensor activation EMA wakes up switching the GSM module on and sending a SMS message or giving an alarm ring Because of the battery effective time we recommend to save one max two phone numbers on the list The option to use up to six phone numbers is recommended s
15. olely for exceptional cases if the permanent charging by 12 V voltage is available Declaration of Conformity CE 0980 amp es The FLAJZAR s r o company declares herewith that the EMA GSM alarm device complies with the requirements of the following standards and regulations for the corresponding type of equipment CSN EN 55022 class B CSN EN 55024 CSN EN 50130 4 CSN EN 61000 4 2 criterion A CSN EN 61000 4 3 criterion A EN 301 489 1 1 8 1 EN 301 489 7 V1 3 1 EN 301 511 V9 0 2 CSN EN 60950 1 Council Rec 99 519 EC CSN EN 50131 2 2 CSN EN 50130 5 CSN EN 50136 1 1 the latest version of the EMA alarm firmware Please keep monitoring the website www myema eu where you can find the updated version of i Information induded in these Instructions can differ in dependence on the Instructions and the descriptions of updates done Service and technical support Service for the equipment is provided either by the manufacturer or by the authorized service shops Please ask for information at your seller or WWW myema eu If you do not know how to set up the device or in case of another technical problem do not hesitate to contact us under ema flajzar cz Our technicians will try to help you as soon as possible
16. r do not expose it to the sun If you use the extension cable do not place the alarm e g under the rear window or the windscreen To avoid finding the alarm device by a thief place EMA into a socket at the rear of the car if available Ifyou remove the SIM card the device switches off In case of longer storing or non using remove the SIM card The effective time of the internal Li lon battery depends on the way of its use and the range of ambient temperature Its effective time and number of cycles are limited In case you want to replace the battery or do any other repairs please contact the authorized service or the producer Ifyou have connected the external sensor EMA PIR see on the other side of the sheet do not place it in the sun or near transmitting devices GSM phones radio stations It could cause false alarms Recommended locations between the front seats under the dashboard EMA does not require any changes in the car therefore do not interfere in electrical installation Lead the cable of external sensor so that you do not disturb traffic security getting on and off and motion of persons in the car load handling Be sure that moving seats or persons cannot damage the sensor cables or pull out the EMA connector Do not dismantle or modify the EMA alarm device and its accessories When in stand by mode the GSM module is off and EMA cannot receive any SMS messages or reply to giving rin
17. s permitted the LEDs in protective mode do not emit light and the device does not point out its presence BATT green yellow LED GREEN occurrence of 12 V power supply and charged battery for more than 85 YELLOW occurrence of 12 V power supply and charged battery between 25 84 FLASHES EVERY 1 SEC discharged battery below 25 FLASHES EVERY 4 SEC stand by mode GSM part off GSM blue LED PERMANENT LIGHT netting process or GSM signal drop out no signal in place FLASHES EVERY 4 SEC good signal FLASHES EVERY 1 SEC bad signal ALARM red LED OFF EMA is not protecting DISARM FLASHES EVERY 2 SEC EMA is protecting ARM PERMANENT LIGHT alarm call or SMS sending TRIPLE SHORT FLASHES EVERY 1 SEC EMA is protecting but the time of blocking is counted down upon alarm see EMA config gt Extended adjustment gt paragraph 10 WARRANTY CARD Production number Type of device EMA alarm First name surname company name registration number business address permanent address of the seller Date of sale SMS commands Record on the 1st warranty repair Record on the 2nd warranty repair Record on the 3rd warranty repair If you wish to change the alarm set up and the EMA config program is not available for you you can do the basic configuration using the following SMS commands STATUS LOCATION HISTORY WATCH ROUTE DELETE ROUTE SLEEP ON SLEEP OFF LED ON LED OFF NUMBER1 420123
18. t renews the production set up incl phone numbers and password Device IMEI code to renew the default password 1234 within 20s upon sending this SMS it is necessary to restart by removing the SIM card IMEI command must be without password It activates the device the command can be changed by PC and SW It deactivates the device the command can be changed by PC and SW Se LS Ss Ss SS a a a Attention Before you insert your SIM card and start using the alarm device read the enclosed documentation carefully The security PIN code of the SIM card must be off Ifall LEDs do not go on after inserting the SIM card the battery is probably discharged Please charge the battery using the on board power supply connector To configure by PC USB port please insert the SIM card and charge the internal Li lon battery Letus recommend you not to have any other phone numbers stored on the SIM card except for those stored by the operator This measure allows you to accelerate the device start up and to shorten the time for sending an alarm message after the device wakes up from the stand by mode After inserting the SIM card the LEDs should go out within max 30 seconds and the device should be registered in the GSM network blue GSM LED flashing If it is not the case make sure whether the SIM card is inserted correctly and the corresponding GSM Signal is available on site When placing the EMA alarm in the ca
19. ws switching over the program to the extended set up Here you can find some set ups recommended by the producer About program gt Help it displays the operation instruction for the EMA alarm device About program gt Version it displays the actual version of the program and the links to technical support About program gt Program settings permits or forbids automatic searching for new versions of the EMA config programme About program gt Firmware update opens a window for the EMA alarm firmware update About program gt Update software opens a window for the EMA alarm software update Languages language selection for EMA config interface Installation wizard this guide will help you adjust the EMA alarm device Device name it serves for naming the alarm This name will be displayed at the beginning of each SMS which EMA will send to you e g EMA IS REPORTING UNAUTHORIZED STARTING UP The naming is suitable to distinguish the devices if you use more alarms Q Phone numbers setting EMA allows the communication and control with up to six mobile phones whose phone numbers you can enter into the corresponding fields let us recommend you to use max 2 numbers in practise The first phone number is the so called Master Position Shocks alarm activation in case some shocks are registered the sensitivity to shocks can be adjusted in five stages Voltage drop starting motor activation of the funct