1. Water cooler must be filled with distilled water only The water level of the sonication bath should always reach the red line sticker on the wall of the tank replacement stickers can be obtained from Diagenode e To obtain the best sonication performance the water in the sonication bath and the Water cooler have to be changed at least once per week Please use the provided plastic pump as shown in the images below to release the water from the Water cooler and sonication bath Water temperature e The water in the sonication bath must be kept at 4 C Ultrasonic waves produced by the Bioruptor gene rate heat A drop off in sonication efficiency will occur above 8 C To ensure preservation of the samples and to prevent damage to the instrument it is necessary to start the sonication process with cold water and to keep it at 4 C during the sonication process Never set the temperature below 4 C for the Water cooler since this will damage the machine severely Diagenode Inc North America Phone 1 862 209 4680 Fax 1 862 209 4681 Mail orders na diagenode com PAGE 10 DIAGENODE CONTINUOUS VALVE FOR BIORUPTOR WATER COOLER USER MANUAL Technical Assistance amp Ordering Information Diagenode s a BELGIUM EUROPE Diagenode Inc USA NORTH AMERICA Avenue de Uhopital 1 400 Morris Avenue Suite 101 Tour GIGA 3rd Floor Denville NJ 07834 USA 4000 Liege Belgium Tel 1 862 209 4680 Tel 32 4 364 20 50 Fax 1 862 20
2. blue tubes by inserting them in the appropriate connectors Optional Cut the length you need for the output and input flow Make sure there is enough slack The red and blue tubes must go through the soundproof box holes before being connected to the motorized lid see picture Main Switch 5 Plug the power cord of the Water Cooler 6 Press main switch on the front side of the Water Cooler 7 Fill the tank of the chiller with 3 5 liter and the sonication bath of the Bioruptor up to the red line of the sticker 700 or 730 ml depending on the model with distilled water only do not use deionized water Display LED display status E T Heating l Cooling I L Pump Tr O Arrow keys SET key Start stop key 8 Temperature can be set to 4 C by pushing the SET key and the arrow key of the control panel at the same time 9 Unscrew the tap to allow the circulation of a moderate flow of water 10 Press Start Stop key to control the temperature IMPORTANT NOTE The correct flow is 0 5 liter per minute that has to be determined manually Europe Diagenode sa CHU Tour GIGA B34 3 tage Avenue de l H pital 1 4000 Li ge Sart Tilman Belgium Phone 32 4 364 20 50 Mail info diagenode com DIAGENODE CONTINUOUS VALVE FOR BIORUPTOR WATER COOLER USER MANUAL PAGE 9 Instruction for use Sonication bath and Water cooler Water level and quality e The sonication bath and the
3. 9 4681 Fax 32 4 364 20 51 techsupport na diagenode com techsupport diagenode com orders na diagenode com orders diagenode com For a complete listing of Diagenode s international distributors visit http www diagenode com pages distributors html For the rest of the world please contact Diagenode s a Europe Diagenode sa CHU Tour GIGA B34 3 tage Avenue de l H pital 1 4000 Li ge Sart Tilman Belgium Phone 32 4 364 20 50 Mail info diagenode com EL GO 80 SA AO VNW Ordering information Description Cooling System Water Cooler Bioruptor Bioruptor Standard diagengte Innovating Epigenetic Solutions Cat No BioAcc cool UCD 200 TM 1 5 ml UCD 200 TO 1 5 ml amp 15 ml Diagenode s a BELGIUM EUROPE UCD 200 TS 0 5 0 65 ml Avenue de l h pital 1 Tour GIGA 3rd Floor 4000 Liege Belgium Tel 32 4 364 20 50 aco oo ordersediagenode com Infoediagenode com Diagenode Inc USA NORTH AMERICA 400 Morris Avenue Suite 101 Denville NJ 07834 USA Tel 1 862 209 4680 38 eo 207 465 orders na diagenode com Info naediagenode com For a complete listing of Diagenode s international distributors visit http www diagenode com pages distributors html For rest of the world please contact Diagenode s a 2010 Diagenode Inc All rights reserved The content of this document cannot be reproduced without prior permission of the authors Bioruptor and IP St
4. OOLER USER MANUAL Global scheme i _ Bioruptor _ Water Cooler Environmental Conditions Devices are designed to be safe under the following conditions e Indoor use e Altitude up to 2 000 m e Operating external temperature 0 C to 40 C e Fluid temperature 4 C to 50 C e Maximum relative humidity 80 for temperatures up to 31 C decreasing linearly to 50 relative humidity at 40 C without condensation e MAINS supply voltage from 100V AC to 230V AC with fluctuations up to 10 of the nominal voltage e Transient overvoltages typically present on the MAINS supply e Degree of protection IP20 e POLLUTION DEGREE 2 Normally only non conductive POLLUTION occurs Occasionally however a temporary conductivity caused by condensation is expected Warning Never use In atmosphere with flammable gas N Never use In any location where there Is a possibility of extreme dust Environment exempt from sunlight 15 required Europe Diagenode sa CHU Tour GIGA B34 3 tage Avenue de l H pital 1 4000 Li ge Sart Tilman Belgium Phone 32 4 364 20 50 Mail info diagenode com DIAGENODE CONTINUOUS VALVE FOR BIORUPTOR WATER COOLER USER MANUAL PAGE 7 Equipment installation Before starting the Installation turn the main switch off and make sure that the unit is not plugged into an electrical outlet Location Requirements The Water Cooler must be located below the Bioruptor minimum eleva
5. ad iqgendte i Innovating Epigenetic Solutions Continuous Valve for Installation Guide Version 6 08 05 13 PAGE 3 Contents Introduction 4 Warnings Guarantee Intended use of the equipment Equipment Components Global Scheme Environmental Conditions O O O1 amp Equipment installation 7 Technical assistance 10 Diagenode Inc North America Phone 1 862 209 4680 Fax 1 862 209 4681 Mail orders na diagenode com PAGE 4 DIAGENODE CONTINUOUS VALVE FOR BIORUPTOR WATER COOLER USER MANUAL Introduction Warnings These instructions cannot claim to cover all details of possible equipment variations nor In particular can they provide for every possible example of installation or operation Trouble free and safe operation of the unit is dependent on proper transport and installation by qualified personnel Guarantee Limited one year global warranty Diagenode guarantees its products against possible manufacturing defects in material and workmanship Diagenode products are rigorously tested to ensure that the products you trust meet stringent standards Consequently if a problem occurs with a Diagenode product and the problem is caused by manufacturing defects in material and workmanship Diagenode will in its discretion either fix or replace the product in accordance with the warranty terms and conditions stated herein The warranty applies only to the first purchaser of
6. ar are registered trademarks of Diagenode Inc
7. the product for a period of one year starting from the date this product was delivered In case of repair or replacement on a product under warranty expenses will be at Diagenode s charge including any costs required to return the repaired or replacement product to you This warranty covers only manufacturing defects and does not cover any damage caused by misuse non respect of recommendations described in this manual neglect accidents abrasion exposure to extreme temperatures solvents acids Intended use of the equipment The Continuous Valve for Bioruptor as well as all components from this parcel including plastic tubings and strips must be used as a junction between the Water Cooler and a Bioruptor This equipment is designed to be used in the above described application only Any medical application 15 out of scope Europe Diagenode sa CHU Tour GIGA B34 3 tage Avenue de l H pital 1 4000 Li ge Sart Tilman Belgium Phone 32 4 364 20 50 Mail info diagenode com DIAGENODE CONTINUOUS VALVE FOR BIORUPTOR WATER COOLER USER MANUAL PAGE 5 Equipment Components Component Quantity 1 Plastic Connector for motor lid 2 2 Tap Valve 1 3 Tie Wraps 10 4 Tubing blue and red 2 X 2 m 5 Cutting Device 1 Diagenode Inc North America Phone 1 862 209 4680 Fax 1 862 209 4681 Mail orders na diagenode com PAGE 6 DIAGENODE CONTINUOUS VALVE FOR BIORUPTOR WATER C
8. tion Location Requirements AN difference 400 mm or 17 74 inch Tap valve caggaaeseateattne es Prt Lila T L 2j aapi 1 Unpack the Water Cooler 2 Place the tap valve on the outlet blue connector as shown above Note Red connector and red tubing will ensure the waterflow from the sonication bath to the Water Cooler Blue connector and blue tubing will ensure the waterflow from the Water Cooler to the sonication bath 3 Place the two black plastic connectors on the motorized lid The connectors can be placed into one or the other hole of the motorized ld Screw the plastic nut over the motorized lid The short white pieces of tubing have to be inserted in the plastic connectors IMPORTANT NOTE Please make sure that the Bioruptor is always placed on a level surface and that the water cooler is always placed below the Bioruptor If you need to cut a part of the tubing always use the provided Cutting Device Never use scissors because pieces of tubing with bad cuts generate leaks at junctions Only properly cut tubes can be inserted in the connectors Diagenode Inc North America Phone 1 862 209 4680 Fax 1 862 209 4681 Mail orders na diagenode com PAGE 8 DIAGENODE CONTINUOUS VALVE FOR BIORUPTOR WATER COOLER USER MANUAL 4 Position the sonication bath in front of the soundproof box upon the final site Connect the Bioruptor sonication bath to the Water Cooler with the red and