1. DataLynx User Manual 4 0 Modem Connectivity To ensure successful communication at least two modems are required One modem is needed for the PLC and one modem is needed for the PC Each PLC brand typically has a different set of requirements and procedures Generally an ideal modem would support parity and a baud rate of at least 56K to ensure fast and reliable connections Please refer to the PLC s documentation on configuring modem connectivity with the PLC Modbus Serial must be supported on the PLC When configuring DataLynx on what addresses to read please take care in converting the modbus address into the PLC s native memory addressing scheme 4 1 Testing Modem Configuration 12 To aid in configuring and troubleshooting the modem connections use Hyperterminal and manually connect to the PLC s modem from the PC s modem The PLC does NOT need to be connected to the modem This test confirms that the modems can communicate with each other To run the test complete the following steps 1 Start Hyperterminal by going to Start gt Program Files gt Accessories gt Communications gt Hyperterminal 2 In Hyperterminal the user will be prompted for a session name enter the desired session name e g Test Modem 3 Next the user will be prompted for the connection settings select the PC modem s COM Port and configure the necessary settings 4 Click OK 5 To confirm that the modem is working
2. enter AT An OK message should appear from Hyperterminal DataLynx User Manual 6 If the OK appears test the dialing by entering ATDTYYYY where YYYY is the phone number a Ex ATDT2555678 to dial 255 5678 7 Depending on the modem connection and the phone line it may take a few minutes before receiving feedback a If successful Connected XXXXX bps where XXXXX is the baud rate should appear b If not successful an error like one of the following will be received BUSY NO DIALTONE NO CARRIER etc 4 2 Example Setup for AutomationDirect PLCs The information below illustrates the configuration used for testing DataLynx PLC DLO5 Modem for PLC MDM TEL Modem See the MDM TEL setup wizard for configuration information Modem for PC Toshiba Software Modem DL05 PLC configured with the following 1 Port 2 Setup a Modbus Serial b Parity 0 zero 2 Modem Connected to Port 2 13

Download Pdf Manuals

image

Related Search

Related Contents

www.acaia.fr-mode d`emploi V4.3  Symantec™ Client Management Suite 7.5 powered by Altiris  Telestart T100 HTM  IBM PC300GL Celeron 6275, 6285 (61H1061) Motherboard  必ず読んでね! かんたんスタートガイド  D6000 - Codonics Disinfection Technology Systems Reference Guide  

Copyright © All rights reserved.
Failed to retrieve file