Home

ZigBee MicroControl Operation Manual

image

Contents

1. 3 To change the state of the load press the Change button O The Change button will cycle the load through the available state options 4 To enable disable or change the program schedule of a load press the Options button O00 5 To enable or disable the program schedule from the Options screen highlight Program Enable Disable and then press the Ok button 000 The status of the program schedule is displayed B gt a Press the Change button OGO to change the status of the program schedule The Change button will cycle the Program Status between Enabled and Disabled 12 a all oy b Press the Ok button to save the highlighted Program Status Note While on this screen if no buttons are pressed for 5 seconds the display will return to the previous screen 6 To change the program schedule of the load from the Options screen highlight Program Setup and then press the Ok button C There are 4 time schedules that affect all loads If you change a Time and or Status in a schedule it will change the Time and or Status for all devices that use that schedule a To select the Schedule to be modified press the Next button J The Next button will cycle between Schedule 1 Schedule 2 Schedule 3 and Schedule 4 b To modify the selected schedule with the desired Schedule listed at the top of the screen press t
2. N HAL since 1985 www homeauto com ZigBee MicroControl Operation Manual Document Num ber 81R00 2ZB le ie ay gies 2011 Copyr O Home Aut 1 HAI ZigBee MicroControl The ZigBee MicroControl is a tabletop or wall mount unit used to display status for and control ZigBee devices It features a timed Energy Saving Mode that allows you to put connected ZigBee devices into energy savings at the touch of a button The display on the MicroControl allows you to easily set up install and control the wireless ZigBee system The environmentally friendly internal backup battery in the MicroControl provides approximately 4 hours of active use power and up to 24 hours of power in sleep mode Getting Started 1 Unpack the MicroControl Includes MicroControl USB cable and power adapter and this manual 2 Adjust the foot stand by holding the MicroControl in one hand and pushing in gently on the side buttons A Pull the foot from the back of the unit and adjust for a comfortable view Installation The MicroControl can sit on a table or can be mounted on a wall a The MicroControl may be mounted to a wall using the mounting holes B on the foot stand of the MicroControl b Adjust the unit so that the display is facing you by pushing in gently on the side buttons A and swing the unit to an upright position c Insert one end of the supplied USB cable into the US
3. B connector C on the side of the MicroControl Insert the other end of the USB cable into Ce A A the supplied USB Power Adapter Vee d Plug the USB Power Adapter intoan lt J o o electrical outlet A A LA For best results gt The ZIM should be at least 5 feet from electronic devices gt Avoid areas where receiver will be exposed to moisture gt Avoid areas with excessive metal or electrical wiring 2 Sleep Mode When AC power is lost or if the MicroControl is unplugged the MicroControl will remain operational using the internal backup battery However while operating on battery power the MicroControl will enter sleep mode 30 minutes after the last button is pressed To use the display on the MicroControl while it is in sleep mode you must first wake it up by using the Wakeup Button located on the top edge of the MicroControl To wake up the MicroControl press and hold the Wakeup Button for three seconds Home Screen The Home screen shows the current time and allows you to access menus for controlling loads controlling temperature devices configuring the display and configuring the ZigBee network After loads and temperature devices have been configured the Home screen can also display the status of up to three ZigBee loads and or temperature devices 12 01pm 12 01pm Loads Menu Temps Loads Menu Temps Energy Saving Mode The MicroControl has an Energy Savings M
4. d to configure the backlight ZigBee network display options time and date temperature settings and to reset the MicroControl to its factory default settings Main Menu To view or configure the items in the main menu from the Home screen press the Menu button e MAIN MENU Backlight ZigBee Setup Display Options f Back Ok Next The items in the Main Menu are a Backlight b ZigBee Setup c Display Options d Set Time Date e Temperature Settings f Factory Defaults Backlight The Backlight screen is used to set the parameters of the backlight From the Main Menu with the Backlight menu item highlighted press the OK button 0080 Color Displays the value for the current color of the backlight 1 100 Brightness Brightness of the backlight 1 10 Status Sets the backlight options a Always on b Always off c Auto backlight turns on when a button is pressed and automatically turns off Ok Confirm change Change Change selected item Next Select next item in the table Configuring the ZigBee Network The MicroControl is equipped with configuration and diagnostic tools for configuring and monitoring the devices on ZigBee network ZigBee Setup The ZigBee Setup menu is used to view status messages enroll devices disband devices view status of network devices change the device type and assign and edit names of devices on the network ZigBee Status Messages To view
5. evice will be displayed on the Home screen 4 To remove a device from the Home screen highlight the device and remove the X mark from the box by pressing the Toggle button O The status of the selected ZigBee device will no longer be displayed on the Home screen Set Time Date and Daylight Savings Time The Set Time Date menu option allows you to set the current time and date in the MicroControl It also allows you to enter the starting and ending day of Daylight Savings Time 1 1 1 ia C3 W 1 From the Main Menu highlight the Set Time Date menu item using the Next button S eo A i 2 With the Set Time Date menu item highlighted press the OK button gt Back Go back to the previous screen Ok Increment the highlighted value Next Move to the next value Temperature Settings The Temperature Settings menu is used to configure the temperature format Fahrenheit or Celsius that is displayed on the MicroControl 1 From the Main Menu highlight the Temperature Settings menu item using the Next button VO 2 With the Temperature Display menu item highlighted press the Change button to select between i ao the Fahrenheit or Celsius temperature format 3 When the desired temperature format is displayed press the OK button OO 10 Factory Defaults The Factory Defaults menu is used to configu
6. he Change button 000 e c Read the Warning message and then press the OK button OC d There are four periods Morning Day Evening and Night for each schedule To change the time for a period highlight the time and press the Change button gt The time is increased in 15 minute increments gt To disable a period set it and the next period to the same time e To change the status for a period highlight the status by pressing the Next button O00 f To change the status for the selected time press the Change button 000 The Change button will cycle the load through the available state options g When the schedule is complete press the Ok button 00 Controlling Thermostats The Temps button is used to view the status of and control the supported features of enrolled thermostats on the ZigBee network View and Control Thermostats To view and control the available thermostats on the ZigBee network 1 From the Home screen press the Temps button O 0 A list of available thermostats is displayed 2 To highlight a thermostat in the list press the Next button gt O 14 3 To select a thermostat highlight it in the list and press the Ok button 0 O Hall Thermostat Name of the selected thermostat Current Temperature Current temperature reported on the thermostat Cool Setpoint Cool setpoint on the therm
7. ode that can be used to put all connected ZigBee devices into an energy savings state for a specified time period To activate the Energy Savings Mode from the Home Screen press the Wakeup Button momentarily Task Buttons Press to select the task that is displayed above the respective button Caos Press the Task Button on the left Cem Press the Task Button in the middle oe Press the Task Button on the right When the Energy Savings Mode is activated a The display backlight turns green b The remaining number of days and time for Energy Savings Mode is displayed default 4 hours c The Heat and Cool setpoints for all connected Omnistat2 thermostats are offset by 4 degrees d All connected Load Control Modules are turned off 3 Change Time To change the number of days and or time for Energy Savings Mode press the Change Time button 2 Ok Save the current settings Change Increment the highlighted value Next Move to the next value The Energy Savings Mode can be canceled at any time by pressing the Wakeup Button momentarily When Energy Savings Mode ends or is canceled a The display backlight turns back to the configured color b The Heat and Cool setpoints for all connected Omnistat2 thermostats return to their previous settings c All connected Load Control Modules return to their previous settings or current scheduled settings Menu Button The Menu button is use
8. ostat Heat Setpoint Heat setpoint on the thermostat Back Go back to the Home screen Change Change the cool setpoint heat setpoint hold status fan status or mode of the thermostat 4 To change the cool setpoint heat setpoint hold status fan status or mode of the thermostat press the Change button V n kl a Press the UP button to increment or change the setting of the highlighted item b Press the DOWN button to decrement or change the setting of the highlighted item c Press the NEXT button gt to advance to the next item Note While on this screen if no buttons are pressed for 5 seconds the display will return to the previous screen 15 Designed and Manufactured in the USA using components sourced worldwide FCC Statement This device includes 65A26 1 radio module FCC ID HHC 65A261 IC 1516A 65A261 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation In the unlikely event that the device is suspected of causing interference with a radio TV or other receiver try relocating the device the receiver or adjusting the antenna on the receiver This product employs certain elements from one or more of the following U S Paten
9. re all settings in the MicroControl to the original factory default settings This will also delete all configured devices from the MicroControl 1 From the Main Menu highlight the Factory Defaults menu item using the Next button gt 2 With the Factory Defaults menu item highlighted press the OK button gt O 3 Read the displayed warning message 4 To reset the MicroControl to its factory default settings press the Yes button 000 5 To cancel the factory reset and return to the Main Menu press the Cancel button 0080 Controlling Loads The Loads button is used to view the status of view the demand of if applicable control and schedule enrolled load control devices on the ZigBee network View Control and Schedule Loads To view control and schedule available loads on the ZigBee network 1 From the Home screen press the Loads button A list of available loads is displayed 1 To highlight a load in the list press the Next button O0 11 2 To select a load highlight it in the list and press the Ok button er Io Water Heater Name of the selected load Current Status Current status of the individual load Demand Current energy demand of individual load if available Back Go back to the Home screen Change Change the current state of the load Options Enable disable or change the program schedule of the load
10. s screen press the Network button C 2 Highlight the device to be removed from the network and press the Ok button 080 3 To disband the selected device from the ZigBee network from the Device Details screen press the fo oy 7 Disband button V Disband All ZigBee Devices To disband remove all devices from the ZigBee network 1 From the ZigBee Messages screen press the Network button 2 Highlight Disband All and then press the Ok button Cr TO Warning This will remove all enrolled ZigBee devices from the ZigBee network If you Disband All devices you will have to re enroll each device Display Options The Display Options menu option allows you to choose which if any ZigBee loads and or temperatures show up on the Home screen of the MicroControl You can select up to three devices to be displayed 1 From the Main Menu highlight the Display Options menu item using the Next button O00 2 With the Display Options menu item highlighted press the OK button CI TD Back Go back to the previous screen Toggle Place or remove an X mark from the box next to the selected device Next Select the next device in the list 3 To display a device on the Home screen highlight the desired device and put an X mark in the box by pressing the Toggle button gt The status of the selected ZigBee d
11. the ZigBee status messages on the network 1 From the Main Menu highlight the ZigBee Setup menu item using the Next button O00 2 With the ZigBee Setup menu item highlighted press the OK button O Messages that are received by the MicroControl from ZigBee devices the HAI controller and or over the USB port on the MicroControl are displayed on the ZigBee Messages screen Enroll ZigBee Device To enroll a device into the ZigBee network start the enrollment process on the ZigBee device to be enrolled and then 1 From the ZigBee Messages screen press the Enroll button gt O hf I 2 From the ZigBee Enroll menu press the Find Device button C The MicroControl will attempt to find the device that has been put into enroll mode Once the device has been enrolled the screen will display Device Found along with the device address type of device and signal strength Address Displays the address of the ZigBee Device Type Displays the device type Tstat Display or Load Signal Displays the signal strength of the ZigBee device Cancel Cancel the enrollment process for the device found the device will not be saved as part of the ZigBee network Confirm Saves the device found as part of the ZigBee network Type Changes the device type of the device found 3 To change the device type press the Type button O00 The type will s
12. ts IP CO LLC 7 089 125 7 054 271 6 249 516 6 044 062 SIPCO LLC 7 103 511 6 914 893 6 891 838 5 714 931 6 233 327 7 397 907 6 618 578 7 079 810 7 295 128 7 263 073 7 480 501 6 437 692 7 468 661 7 053 767 7 650 425 7 739 378 16
13. witch between Tstat thermostat Display e g HAI MicroControl and Load 4 To save the current device as part of the ZigBee network press the Confirm button O80 Once the device has been saved the device can be given a custom name Name Device Each device on the ZigBee network can have a custom name up to 15 characters By default the device is given a name To save the device with the default name with DONE highlighted press the Select button gt To name the device use the down arrow and right arrow buttons to highlight the character or function and press the Select button When complete highlight DONE and press the Select button Edit Named Device To change the name of a previously named device 1 From the ZigBee Messages screen press the Network button CI 10 2 Highlight the device to be renamed from the list of network devices and press the Ok button 080 3 From the Device Details screen press the Change Name button 0080 4 Highlight the left arrow function press the Select button to delete previously entered characters Rename the device using the down arrow and right arrow buttons to highlight the character or function and press the Select button When complete highlight DONE and press the Select button 7 Disband ZigBee Device To disband remove a device from the ZigBee network 1 From the ZigBee Message

Download Pdf Manuals

image

Related Search

Related Contents

Electrolux ZUS3970P vacuum cleaner  JVC TH-A25 User's Manual    Samsung Diva S5150 Manuel de l'utilisateur(XEF Only)  Peavey PA 200 User's Manual  User Guide for the Polycom® SoundStation® IP 7000 Phone for 8x8  Epson EB-S02  Manual de SERVICIO TÉCNICO. CUENTA PIEZAS  Manual de instrucciones ATEX  Manuale d`Uso  