1. VI Fig 31 VibraLie window for comparative zones test of PDD Examiner or operator marks control questions CQ and relevant questions RQ pressing on corresponding buttons on the Tools panel of VibraLie window After test finishing operator or examiner person asking questions press button on the same Tools panel VibraLie program immediately shows test result on the vertical column The true test shows green column with NDI Non Deception Indication the lie test shows red column with DI Deception Indication if it is impossible to do precise calculation of lie detection program shows yellow column with INC INConclusive result 3 7 5 Psychophysiological detection of deception in LD manual mode Lie detection in manual mode used when question answer audio quality live or recorded is poor for correct mark of questions start and it is impossible to divide questions answers from background audio In this case is necessary to switch program into LD manual mode as it is shown on the Fig 32 40 Preset Video Audio Language wo v v White background Skype mood VIDevice v LD audio About Vibraimage Help Fl Exit Fig 32 Choice of LD manual mode In LD manual mode also is possible lie detection based on comparison test zone and in this case operator or examiner mark the start of control question zone and finish of control question zo
2. 14 To reboot a computer Note if it is necessary to install some updatings of VibralmageLite program after start of a installation file in the opened window of a modifications choice see Fig 2 it is necessary not only to specify the new chosen the program updatings but also corresponding ticks to confirm work with all old already installed the program modifications 2 1 VibraLite software activation Attention 1 Procedure of activation is made once at the first start of the program 2 The received serial key for activation can be used only once 3 Activation procedure demands access to the Internet for acknowledgement key from server 4 Each key of activation is intended for work with its version of the program Key type Software version VI7 xxxxxxxxx C Compatibility VI software is intended for check of compatibility of two people VI7 xxxxxxxxx DC Compatibility VI software is intended for check of compatibility of two people with Skype support VI7 xxxxxxxxx Aggression VI software is intended for check anger level of person VI7 xxxxxxxxx DA Aggression VI software is intended for check anger level of person with Skype support V 7 xxxxxxxxx Z Aura VI software is intended for check aura and vibraimage of person VI7 xxxxxxxxx DZ Aura VI software is intended for check aura and vibraimage of person with Skype support 10 VI7_Xxxxxxxxx_K
3. 3 7 2 Tools panel of VibraLie program Tools panel of VibraLie program shown on Fig 29 HW VIAVARID R 096 2 Fig 29 Tools panel of VibraLie program AVI Xy Tools panel of VibraLie program includes functions corresponding to buttons on the Tools panel from left to right main menu choice avi files download for PDD analysis live video camera connection pause on image and program operations choice of internal vibraimage mode choice of aura vibraimage mode choice of aura to real image mode choice of standard television mode reset parameters and graphs to 0 restart avi file from the beginning graphs reset mark of relevant questions on graphs and LD calculation results mark of control questions on graphs and LD calculation results mark of general questions on graphs indication of PDD results as DI NDI INC start stop of psychophysiological response analyzing time period in manual mode 36 3 7 3 Psychophysiological detection of deception in LD audio mode In LD audio mode user needs firstly to adjust Audio Threshold so that background audio level must be lower than Audio Threshold and audio level of questions and answers must be higher than Audio Threshold In this case every question answer response divided by time period not less than 10 seconds from the next question answer response is characterized by level of changes for every measured psychophysiological para
4. Load file http www elsys ru downloads Vibraimage7Lite zip Run file Vibraimage7Lite exe from archive file Select language for installation procedure Press button Next in the appeared window of the beginning installation Accept the license agreement and to press button Next in the appeared window In the appeared window specify a way to the catalogue where files of the program will be written down then to press button Next Press button Next in the appeared window allows installation of software files on your computer In the appeared window select versions of the program which you want to install on the computer Fig 2 Select Additional Tasks Which additional tasks should be performed Select the additional tasks you would like Setup to perform while installing Vibraimage Lite then click Next C Charming C Compatibility Me C Energy VI C Energy VI C Stress VI C Stress C Suspect VI Suspect Fig 2 VibraLite modification 10 Press button Install at the start of installation 11 If you want to have the VibraLite program in the other modification in the appeared window it is necessary to choose item of installation of virtual camera drivers and press Next 12 Press button Finish at the end of installation 13 VibraLite program pictograms appears after the end of installation in system menu and on desktop of your computer
5. 4 A Fig 26 Saving results 32 3 6 Brain Voice software The program is intended for sound display of the person microvibrations thus the color scale of aura vibrations frequency is replaced on sound signal frequency accessible to person hearing 1 standard micromovements with frequency of 0 1 10 Hz will proportionally be transformed to a standard sound signal with frequency from 100 up to 20000 Hz and the amplitude of vibrations reflects capacity of a sound for each frequency The given mode allows to watch for behaviour of object for example when the visual control over the monitor is impossible or unprofitable over any reason Also this program allows people with loss of sight to receive the full information about emotional condition of the interlocutor at all not seeing him In many cases additional audio signal about a condition ideas and emotions of the person can be more informative and is accessible than visual supervision which too can take place Visually working window of the Brain Voice program little than differs from other programs of lite version vibraimage but the constant going broadband sound signal characterizes the smallest changes of movement and even idea of supervision object 33 3 7 VibraLie program for psychophysiological detection of deception VibraLie program intents for psychophysiological detection of deception of verbal and non verbal lie in auto auto manual an
6. Biotester VI software is intended for check aura and vibraimage of person its frequency histograms V 7 xxxxxxxxx DK Biotester VI software is intended for check aura and vibraimage of person its frequency histograms and with Skype support V 7 xxxxxxxxx V Brain Voice VI software is intended for check sound aura of person V 7 xxxxxxxxx DV Brain Voice VI software is intended for check sound aura of person with Skype support V I7 xxxxxxxxx D Suspect VI software is intended for check suspect level of person V 7 xxxxxxxxx DD Suspect VI software is intended for check suspect level of person with Skype support VI7 xxxxxxxxx S Stress VI software is intended for check stress level of person VI7 xxxxxxxxx DS Stress VI software is intended for check stress level of person with Skype support V 7 xxxxxxxxx T Tension VI software is intended for check tension level of person V 7 xxxxxxxxx DT Tension VI software is intended for check tension level of person with Skype support V 7 xxxxxxxxx Balance VI software is intended for check balance level of person V 7 xxxxxxxxx DB Balance VI software is intended for check balance level of person with Skype support V 7 xxxxxxxxx Charming VI software is intended for check charm level of person V 7 xxxxxxxxx DH Charming VI software is intended for check charm level of person with Skype support V 7 xxxxxx
7. of person in normal condition in tension condition Obvious distinctions between images on Fig 37 and Fig 38 illustrate advantages of the visual analysis of the person condition on external aura in comparison with the visual analysis initial vibraimage The vibraimage method gives significant freedom of a choice of registration of a condition and visual supervision of aura allows to estimate quickly and evidently practically all emotion parameters of the person Brief interpretation of the form and color of aura is resulted below This brief information does not limit and sets to the user of system the basic directions of the analysis of person condition Getting experience and taking into account the specificity of application each user of system can diversify and deepen essentially results of the analysis of aura open secret secrets of soul and a body of the person 47 Red activity and aggression color Yellow trouble and tension color Green normal activity and top condition color Blue rest and calm color Fig 39 Brief aura color interpretation Brief aura form analysis e Any aura asymmetry form color characterized deviation from mental or physiological norms e Any breaks in aura uniformity characterized deviation from mental or physiological norms e Ideal aura has mono color symmetrical and uniform Any real aura differs from ideal and the question of interpretation is to characterized real aura deviati
8. reflex than limited number of contact sensors from traditional polygraphs 42 1 It is necessary to take in account that correct PDD results are base on right vibraimage conditions described in this manual Less illumination noisy camera and slowly computer could give a lot of errors to the result 2 VibraLie system used only for private using VibraLie program results are not accepted by the court and could not be used as juridical evidence The results captured by Vibralmage PRO system could be accepted to the court 3 Remember that lie is natural function of evolution process everybody are lying in some conditions VibraLie system gives you more possibilities for lie detection please use this possibilities according to common sense and based on the laws of your country 4 Please note that suggested PDD examination method shows VibraLie system possibilities but not limited it Users could apply VibraLie system according to their aims and methods 43 3 8 E Monster Program shows facial image of person changed by emotions You could detect monsters by this program even if person is hidden emotions under the mask of normal face This program allows to see monsters around you Webcam looks on the person and transforms the facial images depends on emotional state like it is shown on the Fig 33 Fig 33 Facial dimensions transformed by E Monster program images based on emotional analysis Any changes from no
9. Did you work in office this night 5 Let s go to cinema this weekend 6 Did you ever tell lie to me or my family 7 Really you were in office this night 8 Did you take your purse from home at this morning 9 Did you steal something before 10 Is it true that you were working this night General Blue questions GQ have diverted meaning and have not influence to calculation result but they are necessary for reducing concentration attention of examinee on the relevant questions Response to the control question CQ is very important to the test calculation control question usually asked about past criminals which are happened in everybody life The verbal answer on control question is not so important Yes or No more important is psychophysiological response corresponding to this reply If quantitative average response to control questions is more than analogical quantitative average response to the relevant questions RQ that means person tells true If quantitative average response to relevant questions RQ is more than analogical quantitative average response to the control questions CQ that means person tells lie This results are based on experience of several dozen years of psychophysiological detection of deception Sample of psychophysiological responses for comparative zones test to control and relevant questions captured by VibraLie system is shown on Fig 31 Fs Vibraimage Lie lt 2008 06 03 16_40_23 avi gt
10. ELSYS Emotion Recognition and Lie Detection System VibraLite Version 7 3 User Manual ELSYS Corp WWW ELSYS RU WWW PSYMAKER COM Saint Petersburg 2013 CONTENT 1 Introduction 3 1 1 Basic applications 3 1 2 Specifications 6 1 2 1 VibraLite system data 6 1 2 2 Digital web camera requirements 6 1 2 3 System requirements for local module computer 6 1 3 Package contents 7 2 VibraLite software installation 8 2 1 VibraLite software activation 9 2 2 Reinstall VibralmageLite software 12 3 VibraLite User manual 14 3 1 Main window 14 3 2 Main menu 16 3 3 Image area control 19 3 4 Information accumulation mode 23 3 5 BioTester software 26 3 6 Brain Voice software 32 3 7 VibraLie program for psychophysiological detection of deception 33 3 7 1 Main menu 34 3 7 2 Tools panel of VibraLie program 35 3 7 3 Psychophysiological detection of deception in LD audio mode 36 3 7 4 Psychophysiological detection of deception in manual auto mode 37 3 7 5 Psychophysiological detection of deception in LD manual mode 39 3 7 6 Contactless lie detection application based on VibraLie system and vibraimage method41 3 8 E Monster 43 4 Definition of emotions 44 4 1 VibraImage parameters 44 4 2 Aura Vibralmage 46 4 3 Samples of human aura visualization 48 5 Warranty 52 5 1 Disclaimer of Warranties 52 5 2 Limitat
11. Item Presets menu designed to choice one basic mode in image area mode Vibralmage mode displays vibraimage of person Color for every image pixel depends on its amplitude or frequency of vibrations Fig 15 In VibralmageLite version color for every image pixel depends on its vibrations frequency In AV mode Vibraimage mode external vibraimage aura allocated around the internal vibraimage or simple vibraimage Aura line size depends on medium line vibration amplitude Aura line color depends on maximum line vibration frequency inside vibraimage contour Fig 13 AR mode Aura on the Real image the aura of the person is shown around his real image Fig 14 In LD mode Lie Detector mode image area shows real object image Note at a displayed of the image in VI and AV modes it is possible to change color of a background of the image having chosen main menu item White background i Vibraimage Tension 2008 04 22 16_33_00 avi gt 1N F 100 00 33 Fig 13 AV mode on black background Fig 14 AR mode 20 Vibraimage Aura VI 2008 04 22 15_18_ 28 avi gt VI N F 100 00 41 Fig 15 VI mode on white background 21 22 Note in the left top corner of image window the image processing mode Fig 16 and time from the beginning of viewing AVI file are showed t Vibraimage Tension lt 2 av
12. a from both sides of the researched pair 2 Symmetric painting aura from both sides of the researched pair 52 5 Warranty 5 1 Disclaimer of Warranties You expressly acknowledge and agree that to the extent permitted by applicable law use of the Vibraimage software and services is at your sole risk and that the entire risk as to satisfactory quality performance accuracy and effort is with you To the maximum extent permitted by applicable law the Vibraimage software and services performed by the Vibraimage software are provided as is and as available with all faults and without warranty of any kind and Elsys and Elsys licensors collectively referred to as Elsys for the purposes of sections 7 and 8 hereby disclaim all warranties and conditions with respect to the Vibraimage software and services either express implied or statutory including but not limited to the implied warranties and or conditions of merchantability satisfactory quality fitness for a particular purpose accuracy quiet enjoyment and non infringement of third party rights Elsys does not warrant against interference with your enjoyment of the Vibraimage software and services that the functions contained in or services performed by the Vibraimage software will meet your requirements that the operation of the Vibraimage software and services will be uninterrupted or error free that any service will continue to be made available that defects in the Vi
13. ameters during the examination and indication of questions type and examination result 34 3 7 1 Main menu VibraLie program main menu includes the following functions and options see Fig 28 Preset Video Audio Language Yv v White background Skype mood VIDevice v LD audio About Vibraimage Help F1 Exit Fig 26 Main menu of VibraLie Preset choice of visualization mode from LD real video image AR aura external vibraimage around real video image AV aura around internal vibraimage VI internal vibraimage Video choice of video source as recorded video files avi or live camera video Audio choice of audio threshold of start LD detection and finish LD detection in LD audio mode Language choice of menu language from English Russian Korean White background choice of background color in VI mode Skype mood stand mark for the operation in Skype VI device stand mark for the transfer video to any standard video program like AMCAP from Microsoft LD audio choice of audio mode for lie detection where audio signal more than stand threshold used for start lie detection analyzing time period 35 LD manual choice of manual mode for detection where time period for detection selected by pressing LD button on the Tools panel About Vibraimage user code information Help help information about Vibraimage program Exit program exit
14. braimage software or services will be corrected or that the Vibraimage software will be compatible or work with any third party software applications or third party services Installation of this software may affect the usability of third party software applications or third party services You further acknowlege that the Vibraimage software and services are not intended or suitable for use in situations or environments where the failure or time delays of or errors or inaccuracies in the content data or information provided by the Vibraimage software or services could lead to death personal injury 1 or severe physical or environmental damage including without limitation the operation of nuclear facilities aircraft navigation or communication systems air traffic control life support or weapons systems No oral or written information or advice given by Elsys or an Elsys authorized representative shall create a warranty Should the Vibraimage software or services prove defective you assume the entire cost of all necessary servicing repair or correction Some jurisdictions do not allow the exclusion of implied watranties or limitations on applicable statutory rights of a consumer so the above exclusion and limitations may not apply to you 5 2 Limitation of Liability To the extent not prohibited by applicable law in no event shall Elsys be liable for personal injury or any incidental special indirect or consequential damages whatsoever inc
15. checked up through the Internet and in case of successful end of activation procedure the acknowledgement code Fig 4 will be sent Code C61D 3469 2147 071B 59D4 91B2 4411 E246 Request VI7 GELOLS Answer FD31 A481 FA86 8D51 76CD 117F 6358 5 Fig 4 Successful activation 5 To press button OK Program Vibralmage7Lite will be automatically started in selected version You will see your image with aura like Fig 6 if web camera was connected to your PC You will see the white screen if there are no working video devices connected to PC For start you need to put mouse point on the screen and press right mouse button You will see short system menu like on Fig 5 12 Vibraimage Balance 0 0 Fig 5 Start menu 6 Start operation with system 2 2 Reinstallation of VibraLite software Note the ability to reinstall chosen VibraLite modification on a new computer is given to user This operation is also recommended before any upgrade SW or HW on PC For this purpose it is necessary to execute the following actions 1 To connect to the Internet a computer on which one of VibraLite programs has been installed 2 Start VibraLite program for reinstallation on a new computer 3 In a program window having pressed the mouse right button to cause the menu and to choose item About Vibraimage 13 Preset Video Language White background Skype mood v VIDevice About Vibra
16. d manual modes Program fixes and compares psychophysiological characteristics of person captured in different time period for standard examination methods Every nowadays existing technical means of lie detection registers changes in different psychophysiological parameters of humans Current opinion that significant changes in psychophysiological parameters happens when person is nervous worry and lie When person is still and calm his psychophysiological parameters are more stable in time so if we compare known still time period with examinees question period we determine is it lie or true Different examination methods Comparative Questions test CQT Guilty Knowledge Test GKT Concealed Information Test CIT are constantly developed and improving it is possible to read a lot of literature about it for example http en wikipedia org wiki Polygraph The modern technical lie detection is mostly based on Integrated Zone Comparison Technique IZCT was firstly suggested by Cleve Backster http en wikipedia org wiki Cleve_Backster The comparison test principals are easy for everybody understanding and requests only comparing of responses to control and relevant questions controlled by psychophysiological detector like VibraLie system The main window of VibraLie program indicated on Fig 27 Fig 27 The main window of VibraLie program with time dependence of psychophysiological par
17. e compatibility on the basis of their vibraimage analysis see Fig 44 For reception of a correct estimation of compatibility it is necessary to carry out the rules necessary for reception qualitative vibraimage e Two persons sit down beside as it is possible closely more to each other e Web camera is stand opposite and adjusted so that on the computer screen the image of two persons completely entered in the screen of a computer was visible e The distance from each person up to lateral screen side should be identical and make approximately 10 96 from width of the monitor screen e Light exposure of pair should be sufficient and uniform e Persons should be inverted to the camera and not concern each other Anyother physical contact of pair embraces pressings and other only is welcomed and are raised measurement accuracy e The background should be uniform and it is desirable contrast concerning pair 51 Fig 44 Correct position of people pair Fig 45 Wrong position of people at check of their compatibility People are on different distance from the camera and far apart Compatibility Estimation Ideal compatibility of pair is characterized completely by symmetric aura Any asymmetry of aura characterizes the certain problems in compatibility the more asymmetry the it is more than problems in compatibility To the maximal compatibility there correspond the following aura parameters 1 The symmetric form of aur
18. e energy of the person is displayed Start At repeated pressing of the 152 button a choice of corresponding menu item will be made new accumulation of the information and in graph area the following result of frequency distribution will be displayed Fig 23 Vibraimage BioTester lt 2 gt icai Amin Fig 24 Old and new human state 29 30 The user also has opportunity of viewing previously saved results of the frequency analysis For this purpose it is necessary to pass in a mode of viewing of the frequency histogram in the area of image and then having pressed button Load to load earlier saved data and to compare them with just received To remove the received graph of the frequency analysis it is necessary to bring the mouse pointer to the chosen diagram to press the right mouse button and to choose item Delete To save the received graph it is necessary to bring the mouse pointer to the chosen diagram to press the right mouse button and to choose item Save as Fig 25 fi Vibraimage BioTester v2 avi m e Save as Fig 25 Save and delete results 31 1 Vibraimage BioTester lt v2 avi gt P
19. eater value of parameter corresponds to the greater calculated value 1 2 Specifications 1 2 1 VibraLite system data e Resolution TVL more than 400 e Noise level of Vibralmage bit less than 0 1 e Frame speed frame sec 15 30 e Frequency range Hz more than 0 1 4 15 1 2 2 Digital web camera requirements e Sensor CCD or CMOS Sensor e Resolution pixel From 640 x 480 till 1280 x 1024 e USB compatible USB 1 0 USB 2 0 e Frame speed f s more than 15 25 30 for VibraLie e Microphone external e Exposition control auto and manual e Color mode color and B W switch e Flicker mode Flicker 50Hz and 60Hz 1 2 3 System requirements for local module computer Operation System Windows XP Prof Vista with DirectX 9 0 or later Processor PC with Pentium Core 2 Duo 2500 MHz or better RAM 1024MB or better HDD 100GB or more free space DVD ROM DVDRW USB port 1free USB ports version USB 2 0 PCI slot 1 free slot option Video capture WDM compatible video device 1 3 Package contents Qo dE cw go 05 Vibralmage Lite software Internet key User manual Digital USB camera options Microphone options Personal computer options 2 VibraLite software installation It is necessary to execute the following actions for installation of VibralmageLite program on your computer gt Go to Web page http www elsys ru downloads_e php Vibraimage7Lite zip
20. esulted color scale see Fig 36 scaling in Hz i e violet color frequency vibraimage displays a range of vibrations 0 1 Hz dark blue displays a range of vibrations 1 4 Hz green the range of vibrations displays 4 8 Hz red displays a range of vibrations 8 10 Hz On the basis of the given two primary images the technique assumes definition more than 40 integrated vibraimage parameters reflecting various types of movement and vibration and the parameters divided into 4 basic groups A amplitude parameters F frequency parameters e 5 symmetry parameters e spatial and timing parameters of mathematic calculation 46 4 2 Aura Vibralmage External around of head interline display of the maximal frequency and average amplitude vibraimage looks as aura and more informatively displays a condition of the person than internal vibraimage Color of aura is coded by the same color scale as vibraimage Fig 37 and displays the maximal frequency in each line The size of aura is defined by average amplitude for the given line Any non uniformity in color and the size of aura characterizes movements of object and its emotion condition The normal condition of the person is characterized more uniform external vibraimage aura and for an intense condition of the person are characteristic the big space and color non uniformity of aura Fig 37 External vibraimage aura of person Fig 38 External vibraimage aura
21. external video file Preset video Capture Fiter Language Video Capture Format White background AVI File F3 Skype mood AVI File no sound Ctrl F3 v VIDevice v Look 1320 V2 About Vibraimage IP Camera 1 Help F1 Save image as F2 Print Ctrl P Exit Fig 11 Submenu Video Video Capture Filter by pressing the window of video device setting contrast exposition brightness opens Each device has the especial window of settings Video Capture Format change video capture format Vibralmage System allows to processing as the alive video signal acting from a videocamera and the videodata before written down and saved as a AVI file On default the system works with a signal from a videocamera Subitems AVI File F3 and AVI File no sound Ctrl F3 are intended for a choice for the analysis of an external videofile Mode File no sound use for load AVI files without audio support This mode designed for work with VibraSound mode 19 3 3 Image area control Vibraimages images and external vibraimages auras are displayed in the image area The VibralmageLite basic window can be configured for surveillance in several operating modes s Video by AV Language AR LD White background Skype mood VIDevice About Vibraimage Help F1 Save image as F2 Print Ctrl P Exit Fig 12 Work mode select
22. from connected video device Detail description of vibraimage adjusting rules you could read from Vibralmage PRO professional Manual from the link http www elsys ru downloads VI7 3ManualEng pdf 3 1 Main window Main window Fig 8 consists of the following parts e image area on right side e information window on left side In an information column at the left side on the screen it is displayed calculated by the program values of person emotion level parameters Note the type of the displayed parameter depends on the running program Running program Parameter Compatibility VI Information column indicates the compatibility level of two persons in frame Aggression VI Information column indicates the person aggression activity level Aura VI Information column is not used BioTester VI In an information column is displayed the basic button for switch on off basic work mode Fig 9 15 Brain Voice Information column is not used Suspect VI Information column indicates person suspect level Stress VI Information column indicates person stress level Tension VI Information column indicates person tension level Balance VI Information column indicates person balance level Charming VI Information column indicates person charm level Energy VI Information column indicates person energy level VibraLie Information column indicates person level of psychophysiological
23. gression level is the same pathology as high aggression level User could control his own aggression level or aggression of friends partners and any controlled person 2 Aura VI indication of the personal aura external vibraimage visualized by vibraimage technology 3 Balance VI detection and quantitative measurement of personal mental balance balance scale in from 0 100 the best mental balance state corresponds to 100 4 Brain Voice VI audio indication of person aura visualized by vibraimage technology 5 Biotester VI quantitative measurement of psychological energy changes in personal state calculation of person energy in kkal min psychological state in from 0 100 the best psychological state corresponds to 10096 6 Charming VI quantitative measurement of personal charming level charming scale in from 0 100 the best charming state corresponds to 100 7 Compatibility VI quantitative measurement and testing of couple compatibility for lovers friends familiar partners etc Compatibility scale in from 0 100 the best compatibility corresponds to 10096 8 Energy VI quantitative measurement of personal energy level energy scale in from 0 100 the maximum energy corresponds to 100 9 Stress VI Some of scientists don t correspond stress with emotions however nowadays stress is the most popular term characterizing human mental state Vibralmage allows fairly analyze own or others
24. i gt VI N F 100 00 29 Fig 16 Image example Use VI mode with point frequency analysis F and average on N 100 frames 23 3 4 Information accumulation mode By default at the left in an information column Fig 17 is displayed the current value of the chosen emotional parameter By pressing Start button accumulating information on the chosen parameter will start for 1 minute Vibraimage Tension 2008 04 22 15_31_38 avi gt VI N F 100 00 37 Fig 17 In information columns displayed current parameter value After pressing Start button in an information column sand glass with down counter will appear Fig 18 If thus to press Live button the system will return to a base operating mode with display of the current parameter value 24 Vibraimage Tension 2008 04 22 15_31_38 avi gt VI N F 100 01 54 Fig 18 In information columns displayed timer value On the end of the information accumulating an information column the average value of parameter will be displayed Fig 19 By pressing Restart button the new 1 minute interval of the information accumulation about parameter will start Vibraimage 2008 04 22 15_31_38 avi gt VI N F 100 00 27 Restart Fig 19 In information columns displayed average parameter value 25 26 3 5 BioTester software The given program is intended for carrying out of testing of the pe
25. image Help F1 Save image as F2 Print Ctrl P Exit Fig 6 Program menu 4 In the opened window to press the button Unregister key About Vibraimage Vibraimage 7 Lite License Lite Owner AA11 341F F6E7 3469 DB22 8296 5013 Serial MOLEBGMO DA Unregister key Fig 7 About of program 5 Close the program 6 Connect a new computer to Internet 7 On a new computer to execute the chosen program modification installation and to make registration of a old modification activation key through the Internet according to recommendations of section 2 1 8 After successful program registration the given activation key will be fixed to the given computer 14 3 VibraLite User manual Welcome to the Vibralmage World Thank you for your purchase of VibraLite system This manual is written to help you enjoy vibraimaging and open new features in well known objects Vibralmage technology registers micromovement vibration of person by standard digital web or television cameras and image processing Human head microvibration is linked with the vestibular emotional reflex VER http en wikipedia org wiki Vestibulo emotional reflex of a person and reflects emotions levels Vibralmage system detects human emotions by the control of three dimension 3D head neck movements and fluctuations accumulated in several frames After start of VibraLite program in the basic window there is an image
26. image view the information about software version license type and registered user name Help call the help system about full version Vibralmage software Save image as save current picture to external graphics file Print print current picture Preset Video Language White background Skype mood VIDevice About Vibraimage Help Et Save image as F2 Print Ctrl P Exit Fig 9 Main menu 17 In BioTester mode the appeared main menu will consist of the following additionally items Fig 10 Start H 10s gathering of information is made for 10 seconds and the window of frequency information viewing is showed automatically after 10 seconds Frequency analysis results switching in a mode of frequency analysis graph display BioTester Results to open a window with results of psycho energy condition of the person testing Vibraimage BioTester lt 2 avi gt Preset Video Language White background Skype mood Start 105 Frequency analysis s results BioTester results About Vibraimage Help Fi Save image as F2 Print Ctrl P Exit Fig 10 Main menu in BioTester mode 18 Submenu Video contains options of video modes Its can differ depending on connected devices For example this menu contains the following items Fig 11 You can choose as video source one from many installing in PC video devices or load
27. ion of Liability 52 1 Introduction 11 Basic applications VibraLite software solves the following aims Emotions recognition and quantitative measurement of emotions Vibraimage real time surveillance research and control Aura external vibraimage real time surveillance research analysis and interpretation Control over changes in psychophysiological state of person Personal compatibility Psychophysiological detection of deception lie detection Medical psychophysiological personal diagnostics based on corresponding statistic norms Monsters detection VibraLite program has several modification The choice of modifications is carried out at a stage of software installation Note each of 12 modification requests a separate key for authorization Every VibraLite modification is program independent from the other modifications Setup Vibraimage7 Lite Select Additional Tasks Which additional tasks should be performed Select the additional tasks you would like Setup to perform while installing Vibraimage Lite then click Next Additional icons C Aggression C Aura VI O Aura Vie Balance VI C Balance Brain Voice Fig 1 VibraLite modification choice 1 Aggression VI detection and quantitative measurement of aggression activity personal level as one of the base human emotions Every person has some aggression or activity level and low ag
28. luding without limitation damages for loss of profits corruption or loss of data failure to transmit or receive any data business interruption or any other commercial damages or losses arising out of or related to your use of or inability to use the Vibraimage software and services or any third party software or applications in conjunction with the Vibraimage software however caused regardless of the theory of liability contract tort or otherwise and even if Elsys has been advised of the possibility of such damages Some jurisdictions do not allow the limitation of liability for personal injury or of incidental or consequential damages so this limitation may not apply to you In no event shall Elsys total liability to you for all damages other than as may be required by applicable law in cases 53 involving personal injury exceed the amount of twenty five dollars U S 25 00 The foregoing limitations will apply even if the above stated remedy fails of its essential purpose Elsys Corp 2010 All rights reserved www psymaker com www elsys ru
29. ly after 10 seconds Fig 21 The user can be switched between windows with results of testing emotional conditions and windows with results of the frequency analysis The mode of viewing of frequency analysis graph is maz switched on off by the button or a choice of menu item Frequency analysis results And a mode of viewing of testing of the person condition results Fig 22 is switched on off by the button N or a choice of menu item BioTester results Vibraimage BioTester 2010 03 03 12 37 12 avi 2010 03 04 16 13 18 M 1 352810 f n Fig 21 Frequency analysis results Each histogram is characterized by the following parameters e M the center of weights of frequency distribution average value of microvibrations frequency e S root mean square deviation of frequency distribution D adispersion of frequency distribution 28 P Vibraimage BioTester lt 2 1 gt OK kcalimir Fig 22 BioTester results view mode The point on the graph displays the current psycho energy condition of the person On axis Y the mental condition of the person is displayed in if it is more than the condition is better On axis X in a Kcal minut
30. meter The total changes psychophysiological parameters are characterized by two general indicators P5 integral parameter indicated on the down graph and P20 differential parameter indicated on the vertical column More quantity of P20 parameter after response indicates more high level of psychophysiological response and gives more lie probability for two response comparison Sample of program window for PDD 15 shown on Fig 30 viz VI AVARID 70 2 Fig 30 Program VibraLie window of PDD sample in Audio mode It is necessary to note that calculations of integral response P5 and differential response P20 are doing based on the more quantity of psychophysiological parameters than is indicated on the Fig 30 In the base of LD calculation algorithm are using the same equations as in professional Vibraimage version including calculation of time dependence changes about 30 37 psychophysiological vibraimage parameters The results of comparative testing between traditional contact polygraph and vibraimage PDD shows 95 matching For psychophysiological changes visualization in VibraLie are using the indication of the following vibraimage parameters A value of base processing frame difference amplitude indicated fast head movement of person F3 average value of pixel quantity change for time period of 100 frames processing shows general level
31. ne so as for relevant question zones pressing button LD on the Tools panel of VibraLie window 41 3 7 6 Contactless lie detection application based VibraLie system vibraimage method In spite of complicated processing algorithms VibraLie system is very simple and friendly for users and could do lie detection so mass technology like personal computer application Though psychophysiological lie detector appears before personal computer lie detectors did not receive so mass application firstly because using of contact sensors which are not friendly for privacy First computers also were not using for personal application it were great boxes used only in big companies and term personal computer was joke and nonsense for a long time Traditional polygraph with contact sensors comparative to vibraimage looks like old computer vs modern computers Technical progress is constant and it is difficult to accept the conclusion of several polygraph specialists that the only method for psychophysiological detection of deception is contact and you need to measure only skin galvanic response pulse respiration and blood pressure Really for screening psychophysiological state of person needs to capture uncorrelated psychophysiological data however high quality digital television signal gives greatly more independent psychophysiological information about person based on vestibulo emotional reflex VER http en wikipedia org wiki Vestibulo emotional
32. nts superposition of exponential and uniform distributions 49 Fig 41 Aura photos samples for stress condition of person Aggressive and or tension state Aggressive state is not every time coordinates with tension and tension state is not always coordinates with aggression But often these two emotions accompany each other Aggressive state obligatory characterized by high frequency vibrations and red colors in aura Aura size is more than normal and gaps could absent but color and form non uniformity must present Fig 42 Stress level could be low less than 0 3 Anger level more than 0 7 and tension level more than 0 4 Frequency histogram distribution has maximum in right part of the range and distribution has amount dispersion High speed signals spectrum envelope looks like uniform distribution Fig 42 Aura photos samples for aggression condition of persons 50 Meditation Vibralmage system application allows to register distinction not only between the aggressive abnormally excited and normal condition of the client but also and to register a degree of condition change of the person when the person calms down see Fig 43 or meditates A Fig 43 Samples of self correction person emotional states A 10 seconds after the beginning of supervision B 100 seconds after the person have asked to calm down and count up to 100 People compatibility Vibralmage system application allows to register peopl
33. of head movements and emotional energy for current 20 seconds period F8 peak value of F6 parameter in seconds shows current period of F1 parameter changes indicated minimal time of person response S2 average difference between left and right accumulated movement response of object for 10 second show movement and minds asymmetry P2 dispersion of vibraimage frequency distribution for 100 processing frames indicated dispersion of head movement in time and space 5 integral indicator of psychophysiological response calculated with equal rates for every fixed vibraimage parameters P20 quantitative indicator of psychophysiological response calculated with different rates for the fixed vibraimage parameters because for vibration process some part of psychophysiological parameters are accelerated and other part are inhibited during the one psychophysiological response In auto mode examiner need to control left vertical column because maximal level in this column P20 shows maximum psychophysiological response and could be interpretive as lie 3 7 4 Psychophysiological detection of deception in manual auto mode Principals of comparative testing and averaging for responses of question answer zones coined in the 60 years of XX century by Cleve Backster http www backster net images accuracy pdf gave requested high accuracy psychophysiological detection of deception and have done lie detector the reliable instr
34. ons Note This brief aura interpretation correspond default vibraimage system settings and based on main rules for right vibraimage scanning uniform and stable object illumination high quality and low nose camera application frontal plane object before camera maximum facial image size on monitor mechanical stabilization of camera 48 4 3 Samples of human aura visualization Normal and top emotional state Normal condition characterized by aura color and form uniformity around the head relevant monochrome color in the middle of suggested color scale Activity level is about 0 3 0 6 Stress level is about 0 2 0 5 Tension level is not more than 0 4 Every emotion level measured in the range from 0 till 1 0 and minimal value coordinates with minimal emotion intensity Frequency distribution histogram is near normal Gauss distribution and spectrum of high speed vibraimage signals is near exponential distribution Fig 40 Aura photos samples for normal condition of persons Stress state Stress state characterized by amount gaps in aura form and greatly aura colors non uniformity Aura includes every scale colors and sharp color transfer like red color could transfer to blue Fig 41 Stress level more than 0 7 Aggression or activity level is low not more than 0 5 and tension level is high and usually more than 0 4 Frequency distribution histogram has several modes and high speed vibraimage signals spectrum prese
35. response and lie detection result DI NDI INC E Monster Information column is not used Facial image dimensions depend on personal emotions In heading of the basic window the following information is indicated e of video source Video camera or AVI file e model of video source Video camera model or AVI file name e Name of running Vibralmage module t Vibraimage Aggression lt v2 gt Fig 8 VibralmageLite main window of Aggression modification Note double click by the left button of a mouse in the image field of makes RESET of all saved up information and statistics about frames and start new cycle collection of information 16 3 2 Main menu For a call of the program menu it is necessary to click in a working window the mouse right button The appeared main menu will consist of the following items Fig 9 Preset choice of the basic modes of display of the information VI vibraimage AV aura on vibraimage AR aura on real image LD lie detect mode Video adjustment of a videocamera parameters or loading of an external videofile Language Choice of language of the interface and help system White background white background using Skype mood At teamwork of Skype and Vibraimage programs you can observe current psycho emotion parameters of the interlocutor in Skype program window VIDevice support virtual camera drivers About Vibra
36. rmal status of aggression stress anxiety threat balance charming energy and self regulation could transform human to monster More changes of emotions give more changes from human to monster When person emotions are normal the program image is identical to standard video image It is very funny to look how person image is changed by emotions in such magic mirror 44 4 Definition of emotions Head movements in space classically associated with vestibular system are studied and discussed in relation to the status of vestibular reflexes 1 the vestibulo ocular vestibulo collic and cervico ocular reflexes But it is possible to look on head movements according to the vibraimage system and technology We supposed that head balance for person without consciously movements could be considered as isolated thermodynamic system and any emission of internal energy would change the balance of this isolated system and realized by movements or vibrations Every emotional state characterized by specific energy conversation and work done by the system transfers to micro vibrations if the person forced to stand or seet still The head vibtration parameters frequency in range 0 1 10 Hz and amplitude are stable in time for stable emotional state of person Parameters of vibrations changed only after emotional state alteration Vibralmage technolgy allows to contactless register of person vibration parameters and calculates emotions according to accomula
37. rson and animals condition before after and during any external influences The BioTester differs high sensitivity and instantly displays change of mental concentration and physical energy exchange of alive objects The BioTester shows change of a psycho energy condition of the patient at the weakest influences for example from radiation of mobile phone influence of jewelry amulets biocorrector physical and mental loading on the person The BioTester information field fixes a condition of energy allocated by the person on a horizontal scale in dimension kcal minute and on a vertical scale in a condition of psychological concentration of the person The given values physical parameters are calculated on statistical parameters of the person vibration frequency histograms which help the expert to characterize a condition of the person Note the frequency analysis modes are accessible only to BioTester VI modification of VibralmageLite software Fig 20 Vibraimage BioTester lt 2 avi gt Preset Video Language White background Skype mood v VIDevice Start H 10s Frequency analysis s results BioTester results About Vibraimage Help F1 Save image as 2 Print Ctrl P Exit Fig 20 BioTester mode 27 Start At a choice of item Start 10s or pressing of the button 8 will be made information accumulation for 10 seconds and the window with results of testing is showed automatical
38. stress level that is important for regular mental health control also as precautions rehabilitation and cure for depression states Stress scale in from 0 100 the maximum stress corresponds to 100 10 Suspect VI quantitative measurement of personal suspect level potential danger of person by calculation of aggression stress and anxiety levels Suspect scale in from 0 100 the maximum suspect corresponds to 100 11 Tension VI Anxiety fear tension presents physical emotion realization produced by any alarm independently from conscious or unconscious of this state by person Vibralmage program intends for anxiety level analyzing allows to indicate unconscious alarm and fear so assists in it medical treatment Anxiety scale in from 0 100 the maximum anxiety corresponds to 10096 12 VibraLie psychophysiological detection of deception based on vibraimage technology Contactless high sensitive detection of psychophysiological response during examination and auto lie calculation based on suggested MCQT method 13 E Monster Program shows facial image of person changed by emotions You could detect monsters by this program even if person is hidden emotions under the mask of normal face If in the name of the program there is a sign for example Energy its means that this updating of the program additionally supports work with program Skype All parameters are calculated in a range from 0 up to 100 the gr
39. ted statistics of comparitive testing with EEG skin galvanic reaction and psychological testing Vibralmage technics parameters and research results are below 4 1 Vibralmage parameters Values of amplitude and frequency of vibrations of a person head differ in each point of space and are displayed as pseudo color image Integrated processing of parameters values of vibration in each point can give the general information on parameters of the person movement Vibraimage the person heads displaying amplitude see Fig 34 and frequency see Fig 35 the distributions of vibrations modulated by a color scale see Fig 36 are resulted below Fig 34 Amplitude vibraimage Fig 35 Frequency vibraimage Fig 36 Pseudo color scale of frequency distributions 45 Each point pixel amplitude vibraimage Fig 34 reflects the relative moving of element of the image saved up for determined time as it is known that at insignificant movings the frames difference is proportional to the movement of object For transformation of this relative moving in absolute it is necessary to have the exact information on distance up to object and a working corner of an objective of the chamber then a color scale see Fig 36 can be scaled in millimeters or microns As against amplitude analyses each point frequency vibraimage has physical dimension frequencies Hz as really displays frequency of signal change in each element of the image Therefore the r
40. ument in expert hands The comparative zones are based on the fixed structure of question answer testing including general comparative and relevant questions in one test So fixed test structure allows combine analyzing of response to several similar questions so it is possible to calculate average response to several control questions and separately calculates average response to several relevant questions This testing structure gives more accuracy for any measurement so it is acceptable also for lie detection too Standard lie detection test structure includes 9 14 questions one of this questions relevant most important is presented by several times during one test because was proved that during one test is correct to present the only one relevant question Several relevant questions in one test give more errors because examinee could concentrate only on one question during the test Let s consider the test structure on the simple actual test sample You are interesting where your partner was at night when he tells that was working in office In this case the question Really were you in the office last night is relevant question and the main important question of this test 38 test must includes several questions for replying one meaning answers as Yes or No like the suggested sample 1 Did you have breakfast yesterday as usual 2 Was the cold weather on the morning street 3 Did you tell lie to your friends 4
41. xxx E Energy VI software is intended for check energy level of person V 7 xxxxxxxxx DE Energy VI software is intended for check energy level of person with Skype support V 7 xxxxxxxxx L VibraLie program for psychophysiological detection of deception Lie detector V I7 xxxxxxxxx LD VibraLie program for contactless psychophysiological detection of deception Lie detector with Skype support V 7 xxxxxxxxx M E Monster program shows facial image of person changed by emotions You could detect monsters by this program even if person is hidden emotions under the mask of normal face V 7 xxxxxxxxx MD E Monster program shows facial image of person changed by emotions You could detect monsters by this program even if person is hidden emotions under the mask of normal face Available in Skype 11 Activation procedure 1 For the activation beginning it is necessary to start the program 2 At the first start of the program the activation window Fig 3 will be displayed Code 4411 3469 91B2 071B 59D4 2147 C61D E246 0F 1E CB70 Request Answer Get Answer code using HTTP Fig 3 Activation window 3 In field Request it is necessary to enter the serial number of a key received by e mail or specified by the seller After input of a key to press the button Get Answer code using HTTP Please be careful and paste code without additional gaps 4 The activation key will be