Home
USER MANUAL - Cellular Materials International
Contents
1. 6 g 240 gr 436410 m s 1 73 in 44 mm i gt g i 278030 ft s 7 62 mm NATO j Ill 1 FMJ 9 6 g 148 gr 847210 m s 1 73 in 44 mm Iv 1 30 Caliber M2 AP 10 8 9 166 gr PASEN oes 1 73 in 44 mm Product Specifications Max depth 41 without awning Max width 36 5 Window bolts Grade 8 bolts Awning material Astralloy V2 plate 25 With a NIJ level IIl protection Standard Color Powder Coat Black Protection level NIJ IV Steel Astralloy V2 armor plate 0 5 thick Glass Hawkins Glass Laminated ballistic NIJ 4 Window area 2 at 2 sq ft each Weight 1100 lbs Max height 73 without awning V 10262015A Hoisting the Shield To hoist the shield place an appropriate hook or strap through the eyelet Moving the Shield To move the shield with a pallet jack or fork lift firmly lift and remove the fork accesses doors on both sides Replace the fork access doors once the shield is in position Attaching the Awning optional Align the through holes in the awning with the through holes in the shield roof plate Insert 2x the provided 13 bolt with seated washer though the aligned holes and fasten with a washer and nut V 10262015A Interior Cleaning Instructions for Ballistic Glass 1 Rinse with clean water or glass cleaner to remove abrasive dust and dirt 2 Wash with soap or mild detergent using a soft clo
2. OSE USING MOBILE SHIELDS AGREE TO ASSUME ALL RISKS AND LIABILITIES WHEN USING MOBILE SHIELD SYSTEMS INCLUDING WITHOUT LIMITATION RISKS AND LIABILITIES ARISING FROM INJURY OR DEATH OF ANY PERSON AND RISKS AND LIABILITIES ARISING FROM DAMAGE TO OR DESTRUCTION OF ANY PROPERTY PURCHASERS AND USERS AGREE BY USE OF MOBILE SHIELDS TO INDEMNIFY AND HOLD HARMLESS CMI FROM CLAIMS DEMANDS CAUSES OF ACTION LOSSES DAMAGES PENALTIES LIABILITIES AND EXPENSES ARISING FROM OR RELATING IN ANY WAY TO THE USE TRANSPORTING AND HANDLING OF MOBILE SHIELDS CMI MAKES NO CLAIM OF A LEVEL OF PROTECTION OUTSIDE NIJ STANDARDS AND ONLY WHEN SUBJECTED TO NU TESTING METHODS CMI NEITHER ASSUMES NOR AUTHORIZES ANYONE TO ACCEPT ANY TYPE OF LIABILITY ON BEHALF OF CMI MOBILE SHIELDS ARE DESIGNED TO PROVIDE A LIMITED LEVEL OF PROTECTION IN VERY DANGEROUS SITUATIONS PURCHASERS AND USERS AGREE BY THEIR USE OF MOBILE SHIELDS TO BEAR ALL RESPONSIBILITY FOR THEIR OWN SAFETY CMI MAKES NO WARRANTY WHATSOEVER WITH RESPECT TO MOBILE SHIELDS INCLUDING ANY A WARRANTY OF MERCHANTABILITY OR B WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE WHETHER EXPRESS OR IMPLIED BY LAW COURSE OF DEALING COURSE OF PERFORMANCE USAGE OF TRADE OR OTHERWISE IN NO EVENT SHALL CMI BE LIABLE TO ANY PARTY FOR ANY CONSEQUENTIAL INCIDENTAL INDIRECT EXEMPLARY SPECIAL OR PUNITIVE DAMAGES INCLUDING ANY DAMAGES FOR BUSINESS INTERRUPTION LOSS OF USE REVENUE OR PROFIT WHETHER ARISING OUT OF BREACH OF CON
3. TRACT TORT OR OTHERWISE REGARDLESS OF WHETHER SUCH DAMAGES WERE FORESEEABLE AND WHETHER OR NOT ANY PURCHASER OR USER OF MOBILE SHIELDS WAS ADVISED OF THE POSSIBILITY OF SUCH DAMAGES IN NO EVENT SHALL CMI S AGGREGATE LIABILITY ARISING OUT OF OR RELATED TO PURCHASE AND USE OF ANY PARTICULAR MOBILE SHIELD WHETHER ARISING OUT OF OR RELATED TO BREACH OF CONTRACT TORT OR OTHERWISE EXCEED THE TOTAL AMOUNT PAID TO CMI AS PAYMENT FOR THAT PARTICULAR MOBILE SHIELD THE FOREGOING LIMITATIONS SHALL APPLY EVEN IF THE REMEDIES UNDER THIS DISCLAIMER AND PRODUCT USE AGREEMENT FAIL OF THEIR ESSENTIAL PURPOSE
4. USER MANUAL SS 4 Stationary Shield Patent Pending Manufactured by Cellular Materials International Inc 1201 Five Springs Rd Charlottesville VA 22902 info cellularmaterials com Distributor Nationwide Structures Inc P O Box 55461 Virginia Beach VA 23471 Ph 888 430 0301 Fax 757 464 2787 gail nationwidestructures com V 10262015A Capability Chart National Institute of Ballistic Test Chart National Institute of Justice NIJ Standard 0101 04 ustice NIJ INIJ Certified US NIJ Standard 0101 04 is a standard for Ballistic Resistance of Standard Police Body Armor developed by the law enforcement standards laboratory of the 0101 04 National Institute of Justice NIJ US Department of Justice Washington DC Ballistic est Chart J 1080430 ft s m 1 22 Caliber LR LRN 2 6 g 40 or 329410 m s 1 73 in 44 mm I T 1055 30 ft s i 2 380 ACP FMJ RN 6 2 9 95 gr 322410 m s 1 73 in 44 mm j zoas l 1 9 mm FMJ RN 8 0 9 124 gr 3aie10 m s 1730 44 mm HA E i T 105530 ft s 2 40 S amp W FMJ 11 7 g 180 gr 322410 m s 1 73 in 44 mm 1205230 ft s 1 S mm FM RN 8 0 9 124 gr 367410 m s 1 73 in 44 mm 8 1430230 ft s 2 357 Mag JSP 10 2 9 158 or 436410 m s 1 73 in 44 mm 7 1430430 ft s 1 9 mm FM RN 8 2 9 124 gr inf 1 73 in 44 mm ILA _____ i Sie aa a ain 5 1430230 ft s 2 44 Mag SJHP 15
5. th DO NOT SCRUB Rinse and dry with a soft cloth 3 To remove labels stickers or grease rub gently with a cloth wet thoroughly in VM amp P naphtha kerosene or isopropyl alcohol Wash and rinse Do NOT allow interior surface to come in contact with other solvents razor blades scrapers or squeegees 4 For repair or replacement contact Hawkins Glass Email angele hawkinsglass com Phone 703 339 2194 Product Warranty CMI will guarantee all workmanship to be free of defects for one year from date of shipment This warranty covers welding assemblies and moving parts such as wheels and castors from manufacturing defects This does not cover damage from normal wear and tear or misuse abuse or damage caused by a hostile battle environment Any unauthorized changes made to the SS 4 will void this warranty Paint is not covered by this warranty Items such as the glass will not be covered by CMI but may be covered by the glass manufacturer s own warranty DISCLAIMER AND PRODUCT USE AGREEMENT THE PURPOSE OF MOBILE SHIELDS IS TO PROVIDE PROTECTION FROM SPECIFIC THREATS AND IT IS IMPOSSIBLE FOR CELLULAR MATERIALS INTERNATIONAL INC CMI TO PROVIDE PROTECTION AGAINST ALL SUCH THREATS OR UNKNOWN CONTINGENCIES THESE SHIELDS ARE BUILT USING MATERIALS DESIGNED MANUFACTURED AND TESTED BY SUPPLIERS TO MEET A SPECIFIC THREAT BASED UPON DATA THAT IS PROVIDED BY THE NATIONAL INSTITUTE OF JUSTICE NIJ PERFORMANCE STANDARDS THE PURCHASER AND TH
Download Pdf Manuals
Related Search
Related Contents
LEDD-16311(V)-LD9 Worldwide Homefurnishings 403-775 Installation Guide User manual 738373 Panas。nーc 取扱説明書 RGB 190F RGB 192 RGB 198 Copyright © All rights reserved.
Failed to retrieve file