Home

DLM 2000 - Yokogawa

image

Contents

1. Analysis no time from trigger position Time ms Data Bin Hex display ASCII display and Information Data search Analysis list data can be saved to CSV format files CAN Bus Signal Analysis Functions F4 Option Applicable bus Bit rate CAN bus Trigger modes Auto setup function Analyzable no of frames Analysis results displays CAN version 2 0A B Hi Speed CAN 1SO11898 Low Speed CAN I1SO11519 2 1 Mbps 500 kbps 250 kbps 125 kbps 83 3 kbps 33 3 kbps User defined an arbitrary bit rate from 10 0 kbps to 1 000 Mbps with resolution of 100 bps SOF ID DATA ID OR Error enabled when loading physical values symbol definitions Auto setting of bit rate threshold value time axis scale voltage axis scale and display of analysis results 100 000 frames max Analysis no time from trigger position Time ms Frame type ID DLC Data CRC presence absence of Ack information Connector USB type A connector x 2 front panel x 1 rear panel x 1 USB 2 0 compliant Low Speed Full Speed High Speed USB Printer Class Ver 1 0 compliant EPSON HP PCL ink jet printers USB Mass Storage Class Ver 1 1 compliant mass storage devices Please contact your local Yokogawa sales office for model names of verified devices Electromechanical specifications Supported transfer standards Supported devices USB PC Connection Terminal Connector USB type B connector x 1 Electromechanical specifications USB 2 0 c
2. 3 Lineup includes 200 MHz 350 MHz Bo sandwidth models Lightweight and compact Large 8 4 inch LCD display Long memory Up to 125M points with M2 option High speed sampling Up to 2 5 GS s 1 25 GS s with 4 ch DLM 2000 For more information goto 8 Bs Warranty oon Test amp Measurement Instrume ts Bulletin 7101 00E 7 wi Op ad ae i r E J T E a I YO KM 3 AN J A pala Me v4 a wk gt 4 OMH fre rit 3 TEIT M Easy to Use amp Easyto Ssee p a pe ey a A T aay eee eae Tey I a il in re i e be mipi k ee Be Fol Pe pa i m EA S Easy to use Portrait body large screen makes display easy to see We elevated the large 8 4 inch LCD screen up into the line of sight Also the portrait format saves space on the desk or test bench A compact personal 011011 01 1010 01s S1110 A110 M01 Mss EAV viewing and ease of use Measured values can be accurately read on the 0 1 div sub grid display i 2 a ee nime h TT ie Fey at beers ohye rw Fs nije p aha REER AA yur H wTth jm 5 AX TRS j URTEN Feil Ul a FLAAAA mrT A A A OmMmpacl Hoa Tw hE a Ve he Ww oi _ Horizontal Postion and Scale Knob m Soo fi A e screen inac Footprint is approximately 2 3 the size of an 81 2 x 11 sheet of paper depth of approximately 8 Dedicated Zoom Keys Button Select key moves the cursor up down left right Jog Shut
3. 05 div rms typical value 8bit 25LSB div Max 12 bit in High Resolution mode FULL 200 MHz 100MHz 20 MHz 10 MHz 5 MHz 2 MHz 1 MHz 500 kHz 250 kHz 125 kHz 62 5 kHz 32 kHz 16 kHz 8 kHz can be set for each channel 1 25 GS s 2 5 GS s 125 GS s Repeat Single Single Interleave 1 25 M 6 25 M 12 5 MPoints Repeat Single Single Interleave 6 25 M 25 M 62 5 MPoints Repeat Single Single Interleave 1 25 M 6 25 M 12 5 MPoints Repeat Single Single Interleave 6 25 M 25 M 62 5 MPoints Repeat Single Single Interleave 12 5 M 62 5 M 125 MPoints 100 ns 1 ns div to 500 s div steps of 1 2 5 0 002 Approx 20 000 waveform sec ch Accumulation mode Approx 2 2 us approx 450 000 waveforms sec ch 8 bit excl 4 ch input and logic input Model 701988 100 MHz Model 701989 250 MHz 701988 701989 8 bit input 701980 701981 are available 701988 500 mVp p 701989 300 mVp p Model 701988 40 V Model 701989 threshold 6V 40 V DC ACpeak or 28 Vrms when using 701989 Model 701988 40 V setting resolution of 0 05 V Model 701989 6 V setting resolution of 0 05 V 701988 Approx 1 MQ approx 10 pF 701989 Approx 100 kQ approx 3 pF 1 25 GS s Repeat 1 25 MPoints Single 6 25 MPoints Repeat 6 25 MPoints Single 25 MPoints Repeat 12 5 MPoints Single 62 5 MPoints Triggers Trigger modes Trigger type trigger source A triggers AB triggers Trigger level setting range CH1 to
4. Select OFF Intensity waveform frequency by brightness or Color waveform frequency by color 100 ms to 100 s Infinite Enabled at 100 ms div to 500 s div depending on the record length setting Two zooming windows can be set independently Zoom1 Zoom2 x2 to 2 5 points 1Odiv in zoom area Auto Scroll Edge Edge Qualified State Pulse Width State Width I C option SPI option UART option CAN option LIN option 2 500 record length 1 25 kPoints with standard 10 000 record length 1 25 kPoints with M1 or M1S option 20 000 record length 1 25 kPoints with M2 option Select Rect WAVE Polygon or Parameter mode Automatically displays the history waveforms sequentially Specified or average waveforms AT AV AT amp AV Marker Degree Currently displayed waveform can be retained on screen Parameter measurement Statistical computation of parameters Statistics modes Trend Histogram display of wave parameters Computations MATH Computable no of traces Max computable memory length Reference function Modes Actions Analysis XY FFT Action ON trigger Histogram User defined math G2 Options MAX MIN P P HIGH LOW Rms Mean Sdev IntegTY IntegTY OVER OVER Pulse Count Edge Count V1 V2 AT Freq Period Avg Freq Avg Period Burst Rise Fall Width Width Duty Delay Min Max Ave Cnt Sdev Continuous Cycle History Up to 2 trend or histgram display of sp
5. div 100 mV to 500 mV div 1V to 10 V div 5V 100 mV div to 500 mV div 1 5 of 8 div offset voltage accuracy 1 of setting 0 2 mV 1 of setting 2 mV 1 1 of setting 20 mV Frequency characteristics 3 dB attenuation when inputting a sinewave of amplitude 3div 1 MQ when using passive probe 50 Q 100 mV to 100 V div 20 mV to 50 mV div 10 mV to 10 V div 2 mV to 5 mV div Isolation between channels Residual noise level A D resolution Bandwidth limit Maximum sample rate Real time sampling mode Repetitive sampling mode Maximum record length Ch to Ch deskew Time axis setting range Time base accuracy Max acquisition rate Interleave OFF Interleave ON 2 ch model Standard 2 ch model M1S 4 ch model Standard 4 ch model M1 4 ch model M2 Dead time in N Single mode Logic Signal Input 4 ch model only Number of inputs Maximum toggle frequency Compatible probes Min input voltage Input range Max nondestructive input voltage Threshold level setting ran Input impedance Maximum sampling rate Maximum record length ge Standard M1 M1S option M2 option DLM202x DLM203x DLM205x DC to 200 MHz DC to 350 MHz DC to 500 MHz DC to 150 MHz DC to 300 MHz DC to 400 MHz DC to 200 MHz DC to 350 MHz DC to 500 MHz DC to 150 MHz DC to 300 MHz DC to 400 MHz 34 dB analog bandwidth typical value The larger of 0 4 mV rms or 0
6. B Peripheral Connection Terminal SPI Bus Signal Analysis Functions F2 amp F3 Options Trigger types Byte order Auto setup function Analyzable no of data Decode bit length Analysis results displays Auxiliary analysis functions Analysis result save function 3 wire 4 wire After assertion of CS compares data after arbitrary byte count and triggers MSB LSB Auto setting of bit rate threshold value time axis scale voltage axis scale and display of analysis results 300 000 bytes max Specify data interval 1 to 32 bits decode start point and data length Analysis no time from trigger position Time ms Data 1 Data 2 Data search function Analysis list data can be saved to CSV format files UART Bus Signal Analysis Functions F1 amp F3 Options Bit rate Data format UART Trigger modes Analyzable signals Auto setup function Analyzable no of frames Analysis results displays Auxiliary analysis functions Analysis result save function 1200 bps 2400 bps 4800 bps 9600 bps 19200 bps user defined an arbitrary bit rate from 1 k to 1 Mbps with resolution of 100 bps Select a data format from the following 8 bit Non Parity 7 bit Data Parity 8 bit Parity Every Data Data Error Framing Parity Select CH1 to CH4 logic input or M1 to M2 Auto setting of bit rate threshold value time axis scale voltage axis scale and display of analysis results 300 000 frames max
7. CH4 Trigger level setting resolution CH1 to CH4 Trigger level accuracy CH1 to CH4 Window Comparator Auto Auto Level Normal Single N Single Edge CH1 to CH4 Logic EXT LINE Edge OR CH1 to CH4 Edge Qualified CH1 to CH4 Logic EXT State CH1 to CH4 Logic Pulse width CH1 to CH4 Logic EXT State width CH1 to CH4 Logic TV CH1 to CH4 Serial Bus C optional CH1 to CH4 Logic SPI optional CH1 to CH4 Logic UART optional CH1 to CH4 Logic CAN optional CH1 to CH4 LIN optional CH1 to CH4 User defined CH1 to CH4 A Delay B 10 ns to 10 s Edge Edge Qualified State Serial Bus A to B N 1 to 10 Edge Edge Qualified State Serial Bus Dual Bus Serial bus only 4 div from center of screen 0 01 div TV trigger 0 1 div 0 2 div 10 of trigger level Center Width can be set on individual Channels from CH1 to CH4 Display Display 8 4 inch TFT color liquid crystal display 1024 x 768 XGA Functions Waveform acquisition modes High Resolution mode Sampling modes Accumulation Accumulation time Roll mode Zoom function Zoom factor Scroll Search functions History memory Max data History search Replay function Display Cursor Types Snapshot Computation amp Analysis Functions Normal Envelope Average Max 12 bit the resolution of the A D converter can be improved equivalently by placing a bandwidth limit on the input signal Real time interpolation repetitive sampling
8. JIS C 1901 1987 Protocol Conforms to IEEE std 488 2 1987 IC Bus Signal Analysis Functions F2 amp F3 Options Applicable bus C bus SM bus C Trigger modes Analyzable signals Analysis results displays Auto setup function Analyzable no of data Search function Analysis results save function Bus transfer rate 3 4 Mbit s max Address mode 7 bit 10 bit Complies with System Management Bus Every Start Address amp Data Non Ack General Call Start Byte HS Mode Assignable to CH1 to CH4 Logic input or M1 to M2 Analysis no time from trigger position Time ms 1st byte address 2nd byte address R W Data Presence absence of ACK information Auto setting of bit rate threshold value time axis scale voltage axis scale and display of analysis results 300 000 bytes max Searches data that matches specified address pattern data pattern and acknowledge bit condition Analysis list data can be saved to CSV format files Auxiliary Input Rear panel I O signal External trigger inout DLM20x2 front panel external trigger output GO NOGO output video output 4 terminals DLM20x4 2 terminals P2 option 4 terminals P4 option Probe interface terminal front panel Probe power terminal rear panel Internal Storage Standerd model C8 Option Capacity Standard model 100 MB C8 option 1 8 GB Built in Printer B5 Option Built in printer 112 mm wide monochrome thermal US
9. N AtoB n LIN CAN Dual bus i D combination trigger of 2 serial busses 05 06 The DLM2000 series has two types of filters one processed at the input circuit and one based on MATH functions These filters are effective for rejecting unwanted signals allowing observation of only the desired bandwidths Each channel has 14 low pass filters available from 8 kHz to 200 The input waveform can be filtered using an IIR filter which is a MHz Waveforms of limited bandwidths are stored in internal memory MATH function Filtered waveforms can be displayed at the same time as the input waveform for comparison You can select low pass Cutoff frequencies 200 MHz 100 MHz 20 MHz 10 MHz 5 MHz or high pass filters 2 MHz 1 MHz 500 kHz 250 kHz 125 kHz 62 5 kHz 32 kHz 16 kHz and 8 kHz Cutoff frequency setting range 0 01 Hz to 500 MHz me SS o Input signal Computed waveform Processing with built in filters Dedicated Zoom keys Because the DLM2000 series lets you set zoom factors iii independently you can display two zoomed waveforms with different time axis scales at the same time Also using the Auto ra Scroll function you can automatically scroll waveforms captured in long memory and change the zoomed location With Auto Scroll you can choose forward backward fast forward scroll speed and other control options Se Two types of waveform searching No
10. afe operating area analysis harmonic analysis of power supply current based on EN61000 3 2 and other operations Harmonic analysis of power supply current based on Switching loss analysis EN61000 3 2 Voltage and current waveforms can be input to the 62 5 MW max long Harmonics determined by the IEC standard that are memory M2 models for computation of switching loss V t X i t generated by the target device can be judged for each A wide variety of switching loss analyses are supported including turn applicable class classes A D Bar graphs and lists can on off loss calculation loss including continuity loss and loss over long be displayed for comparing harmonic current limit values cycles 50 Hz 60 Hz with values calculated from actually measured signals e z a i i i ae Harmonic current graph displa Related Accessories Accessories a a 4 P A ba 3 pema 1 n i g 701928 701929 Current probe Baa 700924 Differential probe DC to 100 MHz 701928 701935 DC to 100 MHz DC to 50 MHz 701929 Deskew correction 1000 Vrms 1400 V 30 Arms signal source ww _ DLM 2000 Series Probe power terminal optional Power supply output terminal for current probes 701930 and 701931 and differential probes 701920 701921 701922 700924 700925 and 701926 GP IB connection terminal optional Enables control from a PC External trigger input Lets you input a trigger
11. ameters can be measured repeatedly and the statistical values displayed mean maximum minimum standard deviation etc Cursors can be placed on the displayed waveform from signal data and various measurement values at the intersection of the cursor and waveform can be displayed There are six types of cursor AT AV AT amp AV Marker Degree Cursor Simultaneous level and time difference measurement with the AT amp AV cursor By pressing the SNAPSHOT key to the lower right of the screen you can freeze a white trace of the currently displayed waveform on the screen You can press the key repeatedly and conveniently leave traces for comparing multiple waveforms Also snapshot data recorded on screen can be saved or loaded as files and can be recalled for use as reference waveforms when making comparisons GO NO GO can be determined using trigger 1 e conditions zone waveforms measurement parameters and other criteria For NO GO actions can be carried out at the same time such as sounding a buzzer saving the current waveform or SNAP SHOT key Using snapshots white waveforms An Abnormal waveform detected Action specified for NO GO sending notification to a designated e mail address Buzzer Output Waveforms in which an abnormality occurred can be saved for confirmation and analysis of the phenomena at a later time to printer Save waveform E mail data file transmiss
12. ecied wave parameters X Filter Delay Moving Avg IIR Lowpass IIR Highpass Integ Count user defined math optional 2 Math1 Math2 1 trace for 2ch model Standard model 6 25 MPoints M1 M2 memory expansion option 25 MPoints M2 expansion option 62 5 MPoints Up to 2 traces REF1 REF2 of saved waveform data can be displayed and analyzed All Condition Zone Param Rect Polygon Buzzer Print Save Mail GO NOGO out Displays XY1 XY2 and T Y simultaneously Number of points 1 25k 12 5k 125k 250k Window functions Rectangular Hanning Flat Top FFT Types PS LS RS PSD CS TF CH are available with G2 option Displays a histogram of acquired waveforms The following operators can be arbitrarily combined in equations X SIN COS TAN ASIN ACOS ATAN INTEG DIFF ABS SQRT LOG EXP LN BIN DELAY P2 power of 2 PH DA MEAN HLBT PWHH PWLL PWHL PWLH PWXX FV DUTYH DUTYL 10 eee DLM 2000 Series Power supply analysis function G4 option The maximum record length that can be computed is as well as standard math functions Propagation time difference correction deskew The difference in propagation time of voltage and current probe signals can be automatically or manually corrected Correction range is 100 ns 0 01 ns resolution Automated measurement of power supply analysis parameters Power supply analysis parameters can be measured automatically and simultaneously wit
13. er and safe operation Check here for oscilloscope accessories Yokogawa s Approach to Preserving the Global Environment e Yokogawa s electrical products are developed and produced in facilities that have received IS014001 approval e In order to protect the global environment Yokogawa s electrical products are designed in accordance with Yokogawa s Environmentally Friendy Product Design Guidelines and Product Design Assessment Criteria YOKOGAWA YOKOGAWA CORPORATION OF AMERICA ws enn r o nnn 2 Dart Road Newnan Georgia 30265 1094 U S A Phone 1 770 253 7000 Fax 1 770 251 6427 YOKOGAWA EUROPE B V Euroweg 2 3825 HD Amersfoort THE NETHERLANDS Phone 31 88 4641000 Fax 31 88 4641111 YOKOGAWA ENGINEERING ASIA PTE LTD 5 Bedok South Road Singapore 469270 Phone 65 62419933 Fax 65 62412606 YOKOGAWA MEASURING INSTRUMENTS KOREA CORP i Represented by Phone 82 2 551 0660 Fax 82 2 551 0665 YOKOGAWA SHANGHAI TRADING CO LTD Phone 86 21 5405 0303 Fax 86 21 6880 9254 YOKOGAWA ELECTRIC CORPORATION Communication amp Measurement Business Headquarters 2 9 32 Nakacho Musashino shi Tokyo 180 8750 Japan Phone 81 422 52 6768 Fax 81 422 52 6624 E mail tm cs jp yokogawa com a i Subject to change without notice Ed 02 b Printed in Japan 901 KP All Rights Reserved Copyright 2008 Yokogawa Electric Corporation
14. g to consult the user s manual Solutions of the DLM2000 Analysis Applications DLM 2000 Series Serial analysis function options F1 F2 F3 F4 7 UA R T CA N L IN F C S PI Inputs supported for serial bus analysis Triggers for UART CAN LIN IC and SPI bus signals are supported along eel with decode display analysis serial bus analysis option only on 4 ch models Anag input Logic input can also be used for serial buses excluding CAN and LIN Simultaneous analyses of different busses Two busses can be analyzed simultaneously Waveforms and analysis results from busses with different speeds can be displayed in individual Zoom screens with different scales A wealth of trigger functions A wide variety of trigger conditions can be set such as ID Data trigger combinations and combinations of serial bus triggers with normal edge triggers ee Se ee rt a ee al me me Simultaneous analyses of IC and SPI Simultaneous analyses of CAN and LIN Accessories l PBDH1000 differential probe Differential probe model 701920 model 701924 DC to 500 MHz bandwidth 1 0 GHz bandwidth d 100 KQ approximately 2 5 pF d 1 MQ approximately 1 1 pF d Maximum differential input voltage Maximum differential input d range 12V voltage range 25 V aa Power supply analysis option vey Dedicated power supply analysis options are available 4 ch models only for switching loss joule integral i2t SOA s
15. h standard measurement items Automated measurement of two areas is also possible Waveform computation of power supply analysis parameters Wp Wp Wp Abs Wp P P P Abs P Z Impedance Display of the Area of Voltage Current Operation Allows for checking whether it is within the ASO area of safe operation Harmonic analysis Harmonic current emission standard IEC 61000 3 2 edition 2 2 EN61000 3 2 2000 Trend display Data search and field jump functions Analysis list data can be saved to CSV format files Auxiliary analysis functions Analysis result save function LIN Bus Signal Analysis Functions F4 Option Applicable bus LIN Rev 1 3 2 0 Bit rate 19 2 kbps 9 6 kbps 4 8 kbps 2 4 kbps 1 2 kbps User defined an arbitrary bit rate from 1000 bps to 200 kbps with resolution of 100 bps Break Synch ID DATA ID OR and ERROR trigger Auto setting of bit rate threshold value time axis scale voltage axis scale and display of analysis results 100 000 frames max Analysis no time from trigger position Time ms ID ID Field Data CheckSum information Data search and field jump functions Analysis list data can be saved to CSV format files LIN bus Trigger modes Auto setup function Analyzable no of frames Analysis results displays Auxiliary analysis functions Analysis result save function GP IB C1 amp C11 Options Electromechanical specifications Conforms to IEEE std 488 1978
16. inary waveform data using waveforms data from a DL using an external program The API is captured by the DLM2000 series By adding the MATH option you can offered in the form of a DLL that can be called from a enter user expressions for performing waveform computations FFT of up program controlled by the user to 2 Mwords can be performed 09 Main Specification Models Model name Frequency bandwidth Input terminal Max sample rate DLM2022 710105 200MHz DLM2032 710115 350MHz 2 analog channels 1 25GS s DLM2052 710125 500MHz interleave mode off DLM2024 710110 200MHz 4 analog channels eee DLM2034 710120 350MHz 3 analog channels tinterleave mode ony DLM2054 710130 500MHz eelegie Basic Specifications Analog Signal input Input channels Analog input DLM20x2 CH1 CH2 DLM20x4 CH1 to CH4 CH1 to CH3 when using logic input Input coupling setting AC DC DC50 Q9 GND Input impedance Analog input 1 MQ 1 0 approximately 20 pF 50 Q 1 0 VSWR 1 4 or less DC to 500MHz Voltage axis sensitivity 1MQ 2 mV div to 10 V div steps of 1 2 5 setting range 50 Q 2 mV div to 500 mV div steps of 1 2 5 Max input voltage 1 MQ 150 Vrms CAT I 50 Q Must not exceed 5 Vrms or 10 Vpeak Max DC offset 1 MQ 1V 2 mV div to 50 mV div setting range 10V 100 mV div to 500 mV div 100V 1 V div to 10 V div 50 Q 1V 2 mV div to 50 mV div DC accuracy Offset voltage accuracy 2 mV to 50mV
17. ion Waveform parameters such as period pulse width and amplitude can be measured repeatedly and displayed in graphs In a single screen you can observe period by period fluctuations compute amplitudes every screen using multiple waveforms and display amplitudes as trends You can also display histograms referencing the voltage or time axis using values from repeated automated measurement of waveform parameters Trend display of waveform parameters Histogram display using the time axis Up to 2 FFT analyses can be performed simultaneously FFT can be performed on computed waveforms in addition to the actual waveforms on CH1 to CH4 Analysis can be performaed of the frequency components of waveforms filtered for limited bandwidth of frequency for changes in period of rotary objects and other phenomena FFT analysis Thumbnails of waveform data waveform image data and Wave Zone files can be displayed The image and file names are shown so that you can view screen image contents while copying or deleting files In addition to normal sized screens you Can even save wide images that have been zoomed along the time axis Thumbnails of saved files Zoomed 2x long image file You can view detailed graphical explanations of the oscilloscope s functions by pressing the key in the lower left of the screen This lets you get help on functions and operations on screen without havin
18. n printer Differential probe 701921 DC to 100 MHz bandwidth max 700 V Memory expansion option 4 ch model only Differential probe 701922 DC to 200 MHz bandwidth max 20 V During continuous measurement 6 25 Mpoints Single mode Differential probe PBDH1000 701924 DC to 1 GHz bandwidth 1MQ max 25 V 25 Mpoints when interleave mode ON 62 5 Mpoints Differential probe 700924 DC to 100 MHz bandwidth max 1400 V Memory expansion option 4 ch model only Differential probe 700925 DC to 15 MHz bandwidth max 500 V During continuous measurement 12 5 Mpoints Single mode Differential probe 701920 DC to 500 MHz bandwidth max 12 V 62 5 Mpoints when interleave mode ON 125 Mpoints Current probe PBC050 701929 DC to 50 MHz bandwidth 30 Arms Memory expansion option 2 ch model only During continuous measurement 6 25 Mpoints Single mode Current probe 701930 DC to 10 MHz bandwidth 150 Arms 25 Mpoints when interleave mode ON 62 5 Mpoints Current probe 701931 DC to 2 MHz bandwidth 500 Arms Probe power for 2 ch models Mini clip converter 700971 For models 701938 and 701939 Probe power for 4 ch models BNC adapter 700972 For models 701938 and 701939 GP IB Interface PCB adapter 366945 For models 701938 and 701939 10 per set Ethernet Interface For models 701938 and 701939 1 adapter Solder in adapter 366946 i GP IB Ethernet Interface P red black cables 3 ea Internal storage 1 8 GB Printer roll paper B9988AE Lot size is 10 roll
19. odel and Suffix Codes Standard Main Unit Accessories Model Suffix code Description Part Name Quantity 710105 Digital Oscilloscope DLM2022 2ch 200MHz Power cord with 3 prong to 2 prong adapter 1 710110 Mixed Signal Oscilloscope DLM2024 4ch 200MHz Passive probe model 701938 200 MHz 1 5 m 710115 Digital Oscilloscope DLM2032 2ch 350MHz For models 710105 710110 710120 Mixed Signal Oscilloscope DLM2034 4ch 350MHz Per number of channels Passive probe model 701939 500 MHz 1 3 m For models 710115 710120 710125 710130 710125 Digital Oscilloscope DLM2052 2ch 500MHz Protective iront cover I 710130 Mixed Signal Oscilloscope DLM2054 4ch 500MHz Soft carrying case for probes Peer REDI ULC A cianda Printer roll paper for B5 option VDE standard BS standard AS standard Accessory Models Per number of channels GB standard Specification Help language English Help Menu and Panel Logic probe PBL100 701988 1 MQ input resistance toggle frequency of 100 MHz Chinese Help Menu and Panel Logic probe PBL250 701989 100 kQ input resistance toggle frequency of 250 MHz Korean Help Menu and Panel Passive probe 701938 10 MQ 10 1 200 MHz 1 5m German Help Menu and Panel Passive probe 701939 10 MQ 10 1 500 MHz 1 3m FET Pprobe 700939 DC to 900 MHz bandwidth 2 5MQ 1 8pF Spanish Help Menu and Panel No switchable logic input 4 ch model only Built i
20. ompliant Supported transfer standards High Speed Full Speed Supported class USBTMC USB488 USB Test and Measurement Class Ver 1 0 Ethernet C10 amp C11 Options Connector RJ 45 connector x 1 Transmission methods Ethernet 1000BASE T 100BASE TX 10BASE T Supported services Server FTP VXI 11 Client SMTP SNTP LPR DHCP DNS General Specifications Rated supply voltage 100 to 240 VAC Rated supply frequency 50 Hz 60 Hz Maximum power consumption 170 VA 226 W x 293 H x 193 D mm when printer cover is closed excluding protrusions Weight Approx 4 2kg With no options Operating temperature range 5 to 40 C External dimensions 1 Measured under standard operating conditions after a 30 minute warm up followed by calibration Standard operating conditions Ambient temperature 23 C 5 C Ambient humidity 55 10 RH Error in supply voltage and frequency Within 1 of rating 2 Value in the case of repetitive phenomenon The frequency bandwidth of a single shot phenomenon is the smaller of the two values DC to sampling frequency 2 5 or the frequency bandwidth of the repetitive phenomenon 3 When the input section is shorted the acquisition mode is set to Normal accumulation is OFF and the probe attenuation is set to 1 1 4 Acquisition rate does not vary with an increase or decrease in channels External Dimensions Unit mm eee eee T 2 E E E E m A DLM 2000 Series M
21. rmally searching for data takes time and costs money and long memory is useless without functions for extracting desired data from a large capacity memory That s why the DLM2000 series does not simply offer long memory it also provides powerful waveform search functions earching for data in a single screen the Zoom Search function Searching for history waveforms the History Search function This function searches captured waveforms in the long memory and Criteria can be specified for extracting desired waveforms from up displays waveforms that meet the search criteria in the zoom area to 20 000 previously captured waveforms The locations of the found waveforms are marked on screen w shows the current location e Waveform search criteria Edge edge with conditions state pattern pulse width state Zone created from measured waveforms width serial bus only on analysis option marked Place square zone and search m Waveform search using edge criterion Searching for waveforms in zones created Search for waveforms that pass through do by moving measured waveforms not pass through a rectangular zone placed up down left right on screen Twenty eight waveform parameters are included such as maximum minimum peak to peak pulse width period frequency rise fall time and duty ratio Automated measurement can be performed using up to 20 of these waveform parameters Also waveform par
22. s 10 meters each 701992 SP01 For DL WE series standard version Power supply analysis function includes G2 4 ch model only neil 701992 GP01 For DL WE series with MATH functions UART trigger and analysis 4 ch model only Probe stand 701919 Round base 1 arm IC SPI trigger and analysis 4 ch model only Carrying case 701964 Also for DL1600 DL1700E series UART I C SPI trigger and analysis 4 ch model only CAN LIN trigger and analysis 4 ch model only 1 Logic probes sold separately Please order the model 701988 701989 accessory logic probes separately 2 Only one of these may be selected at a time 3 Specify this option when using current probes or other differential probes such as models 701920 or 701922 z E p 4 Only one of these may be selected at a time Mixed Signal Oscilloscope 5 Only one of these may be selected at a time Special Site Product demonstration Flash now available i 4 JP Check here for updated firmware information G G ka Le Manual download service DLM is a pending trademark or registered trademark of Yokogawa Electric Corporation Any company s names and product names appearing in this document are the registered trademarks or trademarks of their respective companies NOTE A Before operating the product read the users manual thoroughly for prop
23. signal separately from the input signal Ethernet optional Supports 1000BASE T 100BASE TX 10BASE T GO NO GO I O terminal Using the GO NO GO function you can input a timing signal for judging a waveform and output the result as a TTL level signal RGB video signal output terminal You can output an image signal and check Trigger output the waveform on an external monitor Outputs a CMOS 3 3V level trigger signal USB PC connection terminal Enables control from a PC USB peripheral connection terminal Supports USB storage USB keyboards USB printers 1000BASE T 100BASE TX 10BASE T ELLI compliant adapters EALLI Sends waveform screen and settings data eh hh hubs and routers Remote control Mail transmission GO NO GO action l Sends waveform screen and settings data atte a Remote control Ethernet l C10 C11 options E fo l aM Irs a TiS CELEC S USB memory USB printer USB keyboard For details on accessory software visit https y link yokogawa com YL000 po Also you can download free software and trial versions of retail software from this site i i di E M IT x gee See de st TTL AULI F Ltt Xviewer 701992 sold separately DL series library freeware Xviewer is software for use on a PC It can be used for display analysis This is an API that enables you to control a DL or send and conversion to ASCII of b
24. tle and mis 7 Rotary Knob i Tee Logic input connector eys and Level Knob tical Postion and Stale 02 Four Direction Selector PRINT UTILITY CLEAR TRACE SNAF SHOT ER ad B Ji N j T W J d L j j gt E a f N y pet d a ia i gp a se 1 7 semma ed 4 Lj B Four channels is not sufficient to view the functioning of digital control circuits The DLM2000 series converts 4 ch of analog input to 8 bit logic and functions as a 3 ch analog 8 bit logic MSO mixed signal oscilloscope 3 ch analog 8 bit logic a a OE el P E ea E E EON N ine perrormance of u 11 inputs nverting to JI Using logic input up to 11 input signals can be Fast data processing witt observed simultaneously as 3 ch of analog and Scope ORE With our proprietary ScopeCORE fast data processing IC real time display is possible even when simultaneously measuring multichannel signals of 11 inputs 8 bit logic It is not only possible to use logic input for observation of data and control signals or as a trigger source but also for logic input analysis of I C and SPI serial busses Logic probe for the DLM2000 T e DLM2054 710130 4 Bm a ee 2 5 GS s interleave ON 200 MHz 350 MHz 500 MHz 200 MHz 350 MHz 500 MHz 62 5 Mpoints Single measurement memory length M1S interleave ON 125 Mpoints Single measurement memor
25. y function You can search the up to 20 000 previously captured waveforms for history waveforms that meet certain conditions You can perform cursor measurement and other analyses on the found waveforms Waveforms can be displayed in order one at a time by using the rotary knob With the Replay function history waveforms can be automatically played back paused fast forwarded and rewound W __ Trigger function examples A to B n trigger Example Trigger on the 7th edge of signal on B This is effective for measurements with shifted timing such as non standard video signal vertical horizontal periods or motor reference position pulses and drive pulses Input signal A OW 0 Input signal B M Trigger Serial pattern trigger user defined Example Trigger on an arbitrarily set pattern of up to 128 bits This is effective for detecting ID Data and other Pulse width portions of proprietary communication formats State width HHHH LHLH LLLL a eT E STs Te T Dvn Has Arbitrary pattern r eee Ie Trigger Serial optional CAN LIN UART I2C SPI standard user defined TV NTSC PAL SDTV Dual pulse trigger Example Trigger on a combination of CAN and LIN bus triggers I2C SPI bus triggers and other combinations are possible HDTV user defined Trigger when either LIN or CAN bus signal conditions become true Input signal A CAN Mirigas A Delay B Input signal B LI
26. y length M2 interleave ON Or 3 channels when using logic input 03 04 Sophisticated waveform acquisition engine With long memory and the History function you ll never miss an historical waveform A variety of trigger functions reliably capture the waveforms you want gt Large capacity 125 Mpoint memory enables ong duration measurements For taking 2 ch measurements in Single mode you can add the M2 memory expansion option giving you up to 125 Mpoints of large memory capacity 10 000 Hz signals can be recorded for up to 5 000 seconds Even at a sampling rate of 1 25 GS s waveforms down to 0 1 seconds can be captured o ee Measurement r eSt Meast 6 25 Mpoints 12 5 Mpoints Note The M1 M2 memory expansion options are only available on 4ch models The M1S option is only available on 2ch models You can replay waveforms later on so you ll never miss an abnormal waveform STORY _ History Function NEN Soa em 7 wi With the DLM2000 series up to 20 000 previously captured waveforms can be saved in the acquisition memory With the History function you can display just one or all of the previously captured waveforms history waveforms on screen You can also perform cursor measurement computation and other operations on history waveforms Using the History function you can analyze rarely occurring abnormal signals Waveform history Abnormat signal History search function Repla