Home

SM100DMX “Flurry DMX” User Manual

image

Contents

1. MBTLighting com SM100DMX Flurry DMX User Manual mbTryNe LIGHTING Ne SM100DMX Flurry DMX User Manual INTRODUCTION Congratulations on the purchase of your MBT Lighting SM100DMX snow machine Please read this manual carefully and thoroughly before using it in order to operate it properly SAFETY INFORMATION Pay attention to all warning labels and instructions printed on the exterior of your MBT Lighting Flurry DMX Snow Machine 1 For indoor use only Do not use outdoors Keep this machine dry It must be used in a dry moisture proof place in order to work effectively This machine is not water or splash proof If moisture water or snow liquid gets inside the housing immediately unplug the unit and contact a service technician or your MBT Lighting dealer before using it again 2 Keep the snow machine in a well ventilated area Never cover the unit s vents In order to guarantee adequate ventilation allow a free air space of at least 20 cm around the sides and top of the unit 3 The Snow Machine can be used on the ground flat or mounted overhead at no less than a 15 angle Always keep it upright 4 Do not use the Snow Machine without the proper liquid Contact your MBT Lighting dealer to order Use snow fluid liquid ONLY otherwise any other liquid used will cause damage rendering the snow machine unusable and your warranty invalid Never add flammable liquids of any kind oil gas perfume to
2. N Capability 5 Liters Dimension L515 W257 H220MM Weight 12 5KG Save these instructions For more info please visit mbtlighting com or call us at 1 800 845 1922 or email at info mbtlighting com 3 3
3. ition For the 110V models use 3 prong grounded electrical outlet only Before using make sure that the unit is installed at the rated voltage Power cord should be grounded Press the switch on the rear of panel to 1 and LED indicator will be on 2 Controller box control MASTER mode A Set dipswitch10 is off and connect Z 6 with snow machine The Red LED indicator ON means controller box has connected with power Blue LED is off B Press the Green knob MANUAL button to spray snow manually C Press the Red knob or CONT button to spray snow consecutively and rotate VOLUME knob to adjust snow volume D Press the Yellow knob or TIMER button to spray snow at 10 seconds 20 minutes intervals Rotate the INTERVAL knob to adjust interval time Rotate the VOLUME knob to adjust snow volume in interval mode Fixed time of spraying snow or blowing wind is 30 minutes 3 DMX control Set dipswitch10 to ON and connect DMX signal cord with snow machine When there has DMX signal the blue LED will flash Set up initial DMX channel via DIP switch and then snow machine can be controlled by DMX channels The first channel controls snow volume and the second channel controls wind volume ES 1 2 4 8 16 32 64 128 256 ON 0 0 0 0 O 0 0 0 0 OFF AddR Add1 Add2 Add3 Add9 For example1 3 7 9NON 2 4 5 6 8NOFFIN AddR 1 0 4 0 0 0 64 0 256 325 2 3 MBTLighting com SM100DMX Flurry DMX User Manual 4 MASTER SLAVE mode
4. the snow liquid 5 When filling refilling always unplug your Snow Machine before filling its tank Do not drink the snow fluid Always secure snow liquid cap before using the machine and keep dust and other particles out of the snow fluid container 6 Always monitor tank fluid level during operation Running a snow machine with no snow fluid can permanently damage the unit 7 The snow machine produces a low minimum wind noise when working 8 No user serviceable parts inside Refer to your MBT Lighting dealer or other qualified service personnel 9 For adult use only Snow machine must be installed out of the reach of children Never leave the unit running unattended 10 Never aim the output nozzle directly at people 11 Turn off or unplug the power cord when not in use BRIEF INTRODUCTION OF FUNCTION 1 SM100DMxX has two working modes DMX 512 control e Z 6 controller box control 1 3 MBTLighting com SM100DMX Flurry DMX User Manual 2 In DMX mode machine receives consecutive DMX value from channel 1 and DMX address decides snow volume and controls wind pump Z 6 controller box has three functions e Manual mode max volume of spraying snow e Consecutive mode volume of spraying snow can be adjusted e Interval mode volume of spraying snow can be adjusted OPERATIONAL INSTRUCTION 1 Switch on and begin Plug power cord into a grounded electrical outlet Turn power switch on rear of unit to ON pos
5. with Z 6 controller box A Connect all fixtures with DMX signal cord and set the first machine in MASTER mode B Connect the first machine with Z 6 controller box and the others are slaves C Set DMX address of SLAVES 001 and the machine now can be controlled by MASTER SLAVE mode D The Blue LED on MASTER will be off and Blue LED on slave will be on MAINTENANCE Frequent maintenance will extend the Snow Machine 1 Do not allow the snow liquid to become contaminated Always replace the caps on the snow liquid container and the snow machine liquid tank immediately after filling Clear snow cloth and filtrated tip 2 Before storing flush out the system with clean water TROUBLESHOOTING If you experience low output mechanical noise or no output at all unplug immediately Check fluid level the external fuse remote connection and power from the wall If all of the above appears to be OK plug the unit in again If snow does not come out after holding the remote button down for 30 seconds check the hose attached to the tank to make sure there is fluid going through the hose If you are unable to determine the cause of the problem do not simply continue pushing the remote button as this may damage the unit Return the machine to your MBT Lighting dealer TECHNICAL SPECIFICATION Type SM100DMX Name Flurry DMX Snow Machine Voltage AC 230V 50Hz AC 120V 60Hz Power 1000W Fuse 250V 6 3A or 110V 10A Volume of Snow 1000MM MI

Download Pdf Manuals

image

Related Search

Related Contents

PTX-DDS - RVR Elettronica SpA Documentation Server  Quick Start Guide - BIBOX Store BIBOX Store  PowerPoint プレゼンテーション  DTR620  azores, bermuda, madeira, bali, capri, elba, tiziano, vulcano.  Driver WINDOWS XP_IT  

Copyright © All rights reserved.
Failed to retrieve file