Installation instructions
Contents
1. e Above figure is only a simple presentation of the unit it may not match the external appearance of the unit you purchased e Installation must be performed in accordance with the national wiring standards by authorized personnel only Installation instructions Select the installation location Location for Installing Indoor Unit e Where there is no obstacle near the air outlet and air can be easily blown to every corner e Where piping and wall hole can be easily arranged e Keep the required space from the unit to the ceiling and wall according to the installation diagram on previous page e Where the air filter can be easily removed e Keep the unit and remote controller 1m or more apart from television radio etc e To prevent the effects of a fluorescent lamps keep as far as possible e Do not put anything near the air inlet to obstruct it from air absorption e Where there is strong enough to bear the weight and is not tend to increase operation noise and vibration Location for Installing Outdoor Unit e Where it is convenient to install and well ventilated e Avoid installing it where flammable gas could leak e Keep the required dista
2. Access door Terminal inside Outdoor unit The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected Caution 1 Never fail to have an individual power circuit specifically for the air conditioner As for the method of wiring refer to the circuit diagram posted on the inside of the access door 2 Comfirm that the cable thickness is as specified in the power source specification 3 Check the wires and make sure that they are all tightly fastened after cable connection 4 Be sure to install an earth leakage circuit breaker in wet or moist area Cable Specifications Capacity Power cord Power connecting cord Power connecting cord1 ni l Btu h Klonniaioress Normal cross Normal cross supply pe sectional area Type sectional area Type sectional area HO7RN F 1 5mm X3 0 75mm X2 ii L aa 2 2 5K 12K HOSVV F 1 0 1 5mm X3 HOSRN E 1 Omm x3 HOSRN F Heat pump To indoor 14K 15K 18K 22K 2
3. The figures in this manual are based on the external view of a standard model Consequently the shape may differ from that of the air conditioner you have selected 4 Front Panel Air Intake Display Panel Emergency Panel Air Outlet Vertical Adjustment Louver Horizontal Adjustment Louver Air Filter Remote Controller Air Intake Pipes and Power Connection Cord Drain Hose Note Condensate water drains at COOLING or DRY operation Air Outlet Display introduction Temperature indicator pee eee EEA ee ead den BE ee ee ee a ee a Ay fit Display set temperature LI L1 It shows FC after 200 hours of usage as reminder to clean the filter After filter cleaning press the filter reset button located on the indoor unit behind the front panel in order to reset the display optional Running indicator o ae Run It lights up when the AC is running It flashes during defrosting o lt gt Timer indicator _ 6 Timer It lights up during set time gt Q m Sleep indicator ETE 0 It lights up in sleep mode Compressor indicator 5 Comp It lights up when the compressor is on Super indicator 0 It lights up in super mode GS Mode indicator e o Heating displays orange others display white DDO Fan speed MAICON orraa eneen 8 Signal Receptor A EE VG VL series 0 0 O
4. The symbols may be different from these models but the functions are similar 5 Display introduction VT series SF DG Right side series DOEA Display introduction UL series 8 0 O Run 2 Sleep o o UQ series 0 OO UP series O0 2 0 o o G oo gt ED Timer Comp Run Sleep The symbols may be different from these models but the functions are similar 5h Display introduction 0 NS DE series Oa NT series VQ TE TF DA DG Middle DH series 0 2 0 The symbols may be different from these models but the functions are similar 5h Display introduction VM series NM DF series NK series 4 gt co B D a Q QOO 2 TA TC series o OO O s The symbols may be different from these models but the functions are similar 5 Display introduction VC series rime SA TD TG DB DC series SC series O ggg D D amp BDD i TEED ap gt oO OS e Emergency button 0 ON OFF To let the AC run or stop by pressing the button The symbols may be different from these models but the functions are similar
5. aK 30K HOSVV F 1 5 2 5mm X3 HO7RN F 1 5 2 5mm X3 HOSRN F Pigat pump To indoor 18K 24K 30K_ HO5VV F 1 5 2 5mm X3 HO7RN F 1 5 2 5mm X4 To indoor HO5RN F 1 0mm X3 0 75mm X3 18K 22K 24K 30K HO7RN F 2 5mm X3 HO7RN E 1 0mm X4Cooling only HOSRN F Heat pump 10 outdoor 28K 30K 36K HO7RN F 2 5 4 0mm X3 HO7RN F 1 0mm X4 To outdoor The cord may be different from the list above It may be used as the next list And it can be larger 0 7A use 0 75mm or 18AWG 0 10A use 1mm or 16AWG 0 16A use 1 5mm or 14AWG 0 20A use 2 5mm or 14AWG 0 25A use 2 5mm or 12AWG 0 32A use 4mm or 12AWG Installation instructions Wiring Diagram Make sure that the color of wires of the outdoor unit and the terminal No are the same as those of the indoor unit e 5K K 8K 9K 10K 12K 14K 15K 18K 22K 24K 30K Model Indoor unit Outdoor unit Indoor unit Outdoor unit Terminal Terminal Terminal Terminal Brown Brown Brown Brown 1L IL Power connecting cord Brown Brown 4L N Blue Plue N j oo on Ni m ower conn eting cor ee ee eee oS D 3 Yellow Green 2 Yellow Green Yellow Green __ Electric Box Menon Neel Electric Box For above models the power supply are connected from indoor unit For some models the ground wire may be connected to the electric box directly For some models the indicators 1L 2L 3L may be 4 5 6 or others
6. And the wires may be different color e 18K 22K 24K 30K Model For these models the power supply are connected from outdoor unit with a circuit breaker Indoor unit Outdoor unit Terminal Indoor unit Outdoor unit Terminal Terminal Terminal Terminal Terminal Power supply Power supply Installation instructions 18K 24K 30K Model Indoor unit Outdoor unit Terminal Terminal Black Yellow Green Yellow Green For these models the power supply are connected from indoor unit 28K 30K 36K Model Indoor unit Outdoor unit Terminal Terminal 1L Terminal L N Power supply For these models the power supply are connected from outdoor unit with a circuit breaker e Defrost Cable for heat pump air conditioner only and it s an optional part Ey Defrost wire indoor a eA m o Sensor outdoor v After connection the defrost wire should be well wrapped with a wrapping tape and the connector should be put inside the unit e Overheat Protection or high pressure protection cable it s an optional part N Wire indoor SS 5 a Sensor outdoor ey After connection the wire should be well wrapped with a wrapping tape and the connector should be put inside the unit e lonizer The i
7. Insulation SISK Wrap the piping joints with thermal 5 insulation materials and then wrap with a vinyl tape SSS wrapped with vinyl type Thermal insulation e Piping Thermal Insulation a Place the drain hose under the piping Thermal insulation b Insulation material uses polythene foam over 6mm in thickness Note Drain hose is prepared by user e Drain pipe should point downward for easy drain flow Small Do not arrange the drain pipe twisted sticking out or wave Sawer cord 1 pipe around do not immerse the end of it in water for heat pump If an extension drain hose is connected to the drain pipe make sure to thermal insulated when passing along the indoor unit Drain hose Defrost cable for heat pump prepared by user e When the piping is directed to the right piping power Cord and drain pipe should be thermal insulated and fixed onto the back of the unit with a piping fixer l gt fixer A Insert the pipe fixer to the slot B Press to hook the pipe fixer onto the base Piping Connection a Connect indoor unit pipes with two wrenches Pay special attention DJ GG to the allowed torque as shown below to prevent the pipes connectors and flare nuts from being deformed and damaged b Pre tighten them with fingers at first then use the wrenches Piping fixer Hook here Model Pipe size Torque Nut width Min thickness 5 7 8 9 10 12 14 15 18 24K Liquid Si
8. of the air conditioner e According to the character of refrigerant R410A the value of GWP is 1975 the pressure of the tube is very high so be careful when you install and repair the appliance e f the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard e The air conditioner must be installed by a professional engineer e The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube Before using the air conditioner be sure to check and preset as the following e Remote Controller presetting Each time after the remote control is replaced with new batteries or is energized remote control auto presetting heat pump lf the air conditioner you purchased is a Cooling Only one heat pump remote controller can also be used e Back light function optional Hold down any button of the remote controller for about 2 seconds the back light will be turned on It will be turned off automatically after about 10 seconds Note Back light is an optional function e Auto Restart Presetting The air conditioner has Auto Restart function You can set or cancel this function when the air conditioner is running e Hold down the emergency button ON OFF for a few seconds this function will be set if you hear beep twice If you just hear beep once this function will be canceled Safeguard
9. or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision The batteries in remote controller must be recycled or disposed of properly Disposal of Scrap Batteries Please discard the batteries as sorted municipal waste at the accessible collection point If the appliance is fixed wiring the appliance must be fitted with means for disconnection from the supply mains having a contact separation in all poles that provide full disconnection under over voltage category III conditions and these means must be incorporated in the fixed wiring in accordance with the wiring rules If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard The appliance shall be installed in accordance with national wiring regulations The air conditioner must be installed by professional or qualified persons The appliance shall not be installed in the laundry Preparation before use Note e When charging refrigerant into the system make sure to charge in liquid state if the refrigerant of the appliance is R407C or R410A Otherwise chemical composition of refrigerant R407C or R410A inside the system may change and thus affect the performance
10. 30V 10 The stabilizer should be of any reputed manufacturer tested and recommended by the Company 11 The purchaser should preserve the original invoice for necessary verification and produce as and when required 12 Warranty null and void if The Air Conditioners is not purchased from the authorized dealers of the company ii The Service Centre copy of warranty card is not received within 7 days of date of purchase at the nearest Authorised Service Centre iii Any damage is caused by accident mishandling tampering with installation or negligence in following instructions of the user manual issued by Company iv Any damage is caused by improper electrical circuit outside the unit or by any defective electrical supply v At any time during the warranty period if any part of the unit is tampered with altered repaired or serviced by any unauthorized person not being the authorized representative of the company or its authorized dealers vi The serial number of the unit or any part thereof is damaged defaced altered obliterated or tampered with or removal for any reason whatsoever viii The unit is unauthorisedly moved from its original place of installation or re installation 13 None of the employees and or Authorized Dealers of the Company have any authority whatsoever to vary the terms and conditions of this warranty 14 This warranty shall be deemed to have been issued at Delhi and courts at Delhi
11. 5 Maintenance Cut off the power supply Turn off the appliance first before disconnecting from power supply a N Grasp position a and Y pull outward to remove the front panel Wipe with a soft and dry cloth y Use a dry and soft cloth to clean it Use soft moisture cloth rts to clean if the front panel is very dirty Never use volatile substance such as gasoline or polishing powder to clean the appliance Never sprinkle water onto the indoor unit Electric shock Reinstall and shut the front panel Reinstall and shut the front panel by pressing position b downward DN L aomas It is necessary to clean the air filter after using it for about 100 hours Clean it as follows Stop the appliance and remove the air filter 1 Open the front panel 2 Press the handle of the filter gently from the front 3 Grasp the handle and slide out the filter Clean and reinstall the air filter If the dirt is conspicuous wash it with a solution of detergent in lukewarm water After cleaning dry well in shade Close the front panel again Clean the air filter every two weeks if the air conditioner operates in an extremely dusty environment The protective device maybe trip and stop i Install the air conditioner at a place that the appliance in the cases listed below can bear its weight in order to operate more quietly O
12. USER S MANUAL LIVE THE FUTURE SPLIT TYPE AIR CONDITIONER LLOYD ELECTRIC amp ENGINEERING LTD To avail 03 Free preventive maintenance services within 1 year of Warranty Please call us at our Toll Free No Gujarat Madhya Pradesh 1800 2582 583 Punjab Haryana Himachal Pradesh J amp K 1800 1377 781 Maharashtra Chattisgarh Goa 1800 1024 212 South India 1800 1200 666 Rest of India 1800 1020 666 Dear Customer Congratulations on being the proud owner of Lloyd Air Conditioner Your Air Conditioner comes with Lloyd Guarantee of Quality Lloyd takes great pride in providing its customers with perfect products that adheres to international quality standards Lloyd is committed to international quality standards Lloyd is committed to provide the ultimate customer satisfaction as nothing brings us greater joy than having satisfied customers of Lloyd At Lloyd feedback and suggestions based on your product usage experience are greatly appreciated Please feel free to contact us at perfectservice lloydmail com NIPUN SINGHAL DIRECTOR Contents Safety introduction lt lt a 1 Preparation before USe teeta eae 2 Safety Precautions rrr 3 Identification of parts CO 4 CO _ 4 Display introduction nn 5 A aan a ere ne er ne eer 6 Protection 7 Troubleshooting 8 Installation instructions Installation diagram 9 Select the installation eos 10 indoor unit Salon 11 UTGOOE un
13. by the company 3 This warranty shall stand automatically terminated in the event of the said unit being serviced repaired installed de installed re installed or otherwise attended to by any person or organization or agency or by the said purchaser himself other than the authorized representative of the company 4 Parts of the unit replaced or repaired under the terms of this warranty are warranted only for the remaining period of the original warranty period 5 For attending any service call under this warranty beyond the municipal limits of the locality in which the authorized representative dealer is situated outstation locations all to and fro travelling and other incidental expenses as prevailing from time to time incurred in connection with the visit of the service personnel technicians etc shall be borne by the said purchaser and shall be payable in advance Additionally all expenses incurred by the authorized representative dealer in collecting the said unit or any part thereof from such outstation locations and its return to the original location shall be borne by the said purchaser 6 Any loss of refrigerant caused due to sabotage improper handling or treatment carelessness accident fire flood earthquake or any natural calamity any corrosive action on the original refrigerant pipes fittings valves etc for whatever reasons shall not be covered under this warranty 7 Inthe event of any change in the location of th
14. d speed this may cause an injury A 4 Se Never insert a stick or similar obstacle It is harmful to your health if the cool air to the unit Since the fan rotates at high reaches you for a long time It is advisable to let the air flow be deflected to all the room ax Turn off the appliance by remote control Do not repair the appliance by yourself Prevent the air flow from reaching the gas firstly before cutting off power supply if If this is done incorrectly it may cause an burners and stove malfunction occurs electric shock etc It is the user s responsibility to make the appliance be grounded according to Do not touch the operation buttons Do not put any objects on the outdoor local codes or ordinances by a licenced when your hands are wet unit technician Identification of parts Indoor unit Outdoor unit IL IL IL EE IL IL IL T T IL ZE T FT IL IL IL I SZ 0 Of
15. de p 6mm or 1 4 inch 15 20N m 17mm 0 5mm 18K 22 24K 28 30 36K Liquid Side 9 53mm or 3 8 inch 30 35N m 22mm 0 6mm 5 7 8 9 10K Gas Side 69 53mm or 3 8 inch 30 35N m 22mm 0 6mm 12 14 15 18K Gas Side 612mm or 1 2 inch 50 55N m 24mm 0 6mm 18K 22 24 28 30 36K Gas Side 16mm or 5 8 inch 60 65N m 27mm 0 6mm 36K Gas Side 19mm or 3 4 inch 70 75N m 32mm 1 0mm The unit of 18K 24K 36K is bigger than the unit of 18K 24K 36K Installation instructions 4 Connecting of the Cable Front panel Terminal inside e Indoor Unit Connect the power connecting cord to the indoor unit by connecting the wires to the terminals on the control board individually in accordance with the outdoor unit connection Note For some models it is necessary to remove the cabinet to connect to indoor unit terminal e Outdoor Unit 1 Remove the access door from the unit by loosening the screw Connect the wires to the terminals on the control board individually as the following 2 Secure the power connecting cord onto the control board with cable clamp 3 Reinstall the access door to the original position with the screw 4 Use a recognized circuit breaker for 24K model or above between the power source and the unit A disconnecting device to adequately disconnected all supply lines must be fitted
16. e unit during the warranty period this warranty shall become null and void unless the fact of the proposed change is communicated in writing to the authorized dealer at least seven 7 days prior to the said change On receipt of such information the authorized dealer or any of its counterparts shall arrange for de installation of the said unit on chargeable basis However in the event of any damage occuring to the unit or to any of its parts during the course of its transit by the said purchaser repair or replacement the said unit or any part thereof damaged shall not be covered by this warranty 8 It shall be the absolute discretion of the company to a effect the repairs or replacement of parts whether at the site of installation or at any service centre and b have the job attended to either by the Company s service personnel or its authorised dealer 9 This warranty is in the nature of and for the purpose of set forth herein above and in particular the Company shall not in any event be liable for direct indirect incidental or consequential loss or damages to either the said purchaser and or his property or any other third party 10 The Air Conditioners is designed to operate at a range 230V 10 Any failure due to operation of the machine beyond these limits will not be covered by the above warranty Customer shall ensure that a stabilizer is installed in those areas where voltage is not available within the warranty range 2
17. ing the environment This marking indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of material resources To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for environmental safe recycling Safety precautions Symbols in this Use and Care Manual are interpreted as shown below Q Be sure not to do Grounding is essential AN Warning Incorrect handling could cause a serious hazard such as death serious injury etc Pay attention to such a situation A ON A A S Use correct power supply in OFF accordance with the rating plate requirement Otherwise serious faults or hazard may occur or a fire maybe break out Keep the power supply circuit breaker or plug from dirt Connect the power Do not use the power supply circuit supply cord to it firmly and correctly breaker or pull off the plug to turn it off lest an electric shock or a fire break out during operation This may cause a fire due to insufficient contact due to spark etc gt C x Do not knit pull or press the power supply cord lest the power supply cord be broken An electric shock or fire is probably caused by a broken power supply cor
18. k Malan eee 16 Air purging 16 Remote controller operating instructions See remote controller instructions Safety instructions To guarantee the unit work normally please read the manual carefully before installation and try to install strictly according to this manual Do not let air enter the refrigeration system or discharge refrigerant when moving the air conditioner Earth the air conditioner properly Check the connecting cables and pipes carefully make sure they are correct and firm before connecting the power of the air conditioner There must be an air break switch After installing the consumer must operate the air conditioner correctly according to this manual keep a suitable storage for maintenance and moving of the air conditioner in the future Type of fuse used on indoor unit controller is 5X20 with rating T 3 15A 250V A residual current device RCD with the rating of above 10mA shall be incorporated in the fixed wiring according to the national rule Warning Risk of electric shock can cause injury or death Disconnect all remote electric power supplies before servicing The maximum length of the connecting pipe between the indoor unit and outdoor unit should be less than 5 meters It will affect the efficiency of the air conditioner if the distance longer than that length This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities
19. nce apart from the wall e The distance between Indoor and outdoor unit should be 5 meters and can go up to maximum 15 meters with additional refrigerant charge e Keep the outdoor unit away from a place of greasy dirt vulcanization gas exit e Avoid installing it at the roadside where there is a risk of muddy water e A fixed base where is not subject to increasing operation noise e Where there is not any blockage for air outlet Indoor unit Pipe length is 15 meters Max 2 amp Oc Outdoor unit OO os p p Lo L Q L Outdoor unit Pipe length is 15 meters Max D 5 LO Oc cC os D 2 L Q Indoor unit Model Max Allowable Tubing Limit of Tubing Limit of Elevation Required amount of Length at Shipment m Length m Difference H m additional refrigerant g m 5K 18K 5 15 5 20 22K 24K 5 15 5 30 28K 30K 36K 5 15 5 40 If the height or pipe length is out of the scope of the table please consult the merchant Installation instructions Indoor unit installation 1 Installing the Mounting Plate Decide an installing location for the mounting plate according to the indoor unit location and piping direction Keep the mounting plate horizontally with a horizontal ruler or dropping line Drill holes of 32mm in depth on the wall for fixing the plate Insert the plastic plugs to the hole fix the mounting
20. ncy This procedure usually lasts 2 10 minutes During defrosting fans stop operation After defrosting completes it returns to HEATING mode automatically Note Heating is NOT available for cooling only air conditioner models Troubleshooting The following cases may not always be a malfunction please check it before asking for service e If the protector trip or fuse is blown e Please wait for 3 minutes and start again Does not run amp protector device may be preventing unit to work If batteries in the remote controller exhausted If the plug is not properly plugged No cooling or e Is the air filter dirty ad heating air Are the intakes and outlets of the air conditioner blocked Is the temperature set properly e f strong interference from excessive static electricity discharge power supply voltage abnormality presents operation will be abnormal At this time disconnect from the power supply and connect back 2 3 seconds later Ineffective control Does not operate immediately e Changing mode during operation 3 minutes con will delay e This odor may come from another source such as furniture cigarette etc which is sucked in the unit and blows out with the air Peculiar odor e Caused by the flow of refrigerant in the air conditioner not a trouble e Defrosting sound in heating mode A sound of flowing water e The sound may be generated by the e
21. nds Check tightness of all joints using liquid soap or an electronic leak detector 7 Turn 2 and 3 way valves stem to fully the valves Disconnect vacuum pump flexible hose 8 Replace and tighten all valve caps LIVE THE FUTURE WARRANTY TERMS AND CONDITIONS M S LLOYD ELECTRIC amp ENGINEERING LTD WARRANTS THIS LLOYD AIR CONDITIONERS except front grill knobs remote unit amp add on plastic parts TO THE ORIGINAL PURCHASER TO BE FREE FROM DEFECTS IN MATERIALS AND WORKMANSHIP WITHIN ONE YEAR FROM THE DATE OF PURCHASE AS PROVIDED IN THE WARRANTY REGISTERATION CARD LLOYD ELECTRIC amp ENGINEERING LTD HEREAFTER WARRANTS TO THE PURCHASER OF THIS LLOYD AIR CONDITIONERS THAT FOR A PERIOD OF SIXTY MONTHS FROM THE DATE OF INVOICE WE WILL REPAIR REPLACE THE COMPRESSOR WHICH PROVES UPON INSPECTION BY US OR ANY OF OUR AUTHORISED SALES DEALERS TO HAVE BEEN DEFECTIVE DUE TO MANUFACTURING DEFECT This warranty is subject to terms and conditions as mentioned below 1 This warranty shall be valid only for the said period of 12 months as specified above irrespective of whether the said unit has been in use or not for any reason whatsoever or the unit is moved from one location to another Warranty does not cover accessories external to the equipment 2 The warranty period specified above shall include time taken for repairs replacements break downs transit time etc No notice of expiry period of warranty will be given
22. obile No Email Model No Serial No Please Refer Sticker On Back Cover Of Your Product Purchase Date Day Month Year Signatu r Bill No Accept The Terms And Conditions of The Warranty Customer Signature Thank you for selecting a World Class product and we assure you that it will perform as per your expectations We thank you for taking your time to complete this form All Information Provided by You will be Kept Confidential Please Fill In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase We welcome your Valuable Suggestions if any to Improve our Products and Services FOR OFFICE USE ONLY Customer Code Branch Note Company Will Not Be Responsible For The Loss Of This Form During Transit LLOYD ELECTRIC amp EN G N E ERI NG LTD LIVE THE FUTURE LLOYD ELECTRIC amp ENGINEERING LIMITED 159 Okhla Industrial Estate Phase lll New Delhi 110020 Correspondence Address Plot 2 Industrial Area Kalkaji New Delhi 110019 Email perfectservice lloydmail com Customer Care Toll Free No Gujarat Madhya Pradesh 1800 2582 583 Punjab Haryana Himachal Pradesh J amp K 1800 1377 781 Maharashtra Chattisgarh Goa 1800 1024 212 South India 1800 1200 666 Rest of India 1800 1020 666
23. onizer is an optional part A lonizer wire indoor _ ES N After connection the ionizer will work automatically Installation instructions Outdoor unit installation 1 Install Drain Port and Drain Hose for heat pump model only Bi eee The condensate drains from the outdoor unit when the unit operates E in heating mode In order not to disturb your neighbor and protect the environment install a drain port and a drain hose to direct the condensate water Just install the drain port and rubber washer to ik a DS Washer the chassis of the outdoor unit then connect a drain hose to the a in port as the right figure shown Drain port Drain hose prepared by user 2 Install and Fix Outdoor Unit Fix with bolts and nuts tightly on a flat and strong floor If installed on the wall or roof make sure to fix the supporter well to prevent it from shaking due to serious vibration or strong wind 3 Outdoor Unit Piping Connection e Remove the valve caps from the 2 way and 3 way valve e Connect the pipes to the 2 way and 3 way valves separately according to the required torque 4 Outdoor Unit Cable Connection see previous page Air purging The air which contains moisture remaining in the refrigeration cycle may cause a malfunction on the compressor After connecting the indoor and outdoor units evacuate air and moisture from refrigerant cycle using a vacuum pump as
24. plate with tapping screws Inspect if the mounting plate is well fixed Then drill a hole for piping Mounting plate Note The shape of your mounting plate may be different from the one above but installation method is similar 2 Drilla Hole for Piping a S Wall hole sleeve Decide the position of hole for piping according to the D hard polythene tube location of mounting plate i a prepared by user Drill a hole on the wall The hole should tilt a little downward toward outside Install a sleeve through the wall hole to keep the wall o 9mm tidy and clean tilt downward 3 Indoor Unit Piping Installation e Put the piping liquid and gas pipe and cables through the wall hole from outside or put them through from inside after indoor piping and cables connection complete so as to connect to outdoor unit e Decide whether saw the unloading piece off in accordance with the piping direction as shown below Piping direction trough Unloading piece Note When installing the pipe at the directions 1 2 or 4 saw the corresponding unloading piece off the indoor unit base Saw the unloading piece off along the trough e After connecting piping as required install the drain hose Then connect the power cords After connecting wrap the piping cords and drain hose together with thermal insulation materials Installation instructions e Piping Joints Thermal
25. shall have exclusive jurisdiction on matters covered by or following from this warranty and the original purchaser alone shall have cause of action arising out of the transaction LLOYD ELECTRIC amp ENGINEERING LTD en Warranty Registration Card Customer Copy Title Mr Ms Mrs M s Name Residence Address Dist Pin State Occupation Tel Res Fax Code Code Mobile No Email Model No Serial No Please Refer Sticker On Back Cover Of Your Product Purchase Date Signature Day Month Year Bill No Accept The Terms And Conditions of The Warranty Customer Signature Thank you for selecting a World Class product and we assure you that it will perform as per your expectations We thank you for taking your time to complete this form All Information Provided by You will be Kept Confidential Please Fill In Tear off Fold and Mail this form to Reach us within 10 days of the Product Purchase We welcome your Valuable Suggestions if any to Improve our Products and Services FOR OFFICE USE ONLY Customer Code Branch Note Company Will Not Be Responsible For The Loss Of This Form During Transit LLOYD E LECTRIC amp E NG N E E RI NG LTD LLOYD ELECTRIC amp ENGINEERING LTD Serial io Warranty Registration Card Service Centre Copy Title Mr Ms Mrs M s Name Residence Address Dist Pin State Occupation Tel Res Fax Code Code M
26. shown below Note To protect the environment be sure not to discharge the refrigerant to the air directly See next page for air purging steps Refrigerant flow direction 3 way valve diagram 3 way valve connect to indoor unit 6 Open 1 4 turn N 7 Turn to fully open the valve N valve cap open position amp 7 Turn to fully open the Service valve 7 1 Turn spindle ort i LD 8 Tighten 1 Turn o 2 Turn C x needle 8 Tighten Valve cap C rc 8 Tighten Connect to outdoor unit N Valve core service port cap Installation instructions How to Purge Air Tubes 1 Unscrew and remove caps from 2 and 3 way valves 2 Unscrew and remove cap from service valve 3 Connect vacuum pump flexible hose to the service valve 4 Start vacuum pump for 10 15 minutes until reaching a vacuum of 10 mm Hg absolutes 5 With vacuum pump still running close the low pressure knob on vacuum pump manifold Then stop vacuum pump 6 Open 2 way valve 1 4 turn then close it after 10 seco
27. utdoor air temperature is over 24 C HEATING Outdoor air temperature is below 7 C Install the outdoor unit at a place where the air discharged and the operation noise would not annoy your neighbors Room temperature is over 27 C Outdoor air temperature is over 43 C Room temperature is below 21 C Do not place any obstacles in front of the DRY Room temperature is below 18 C air outlet of the outdoor unit lest it increases the noise level COOLING For Tropical T3 Climate condition models the temperature point is 55C instead of 43 C The temperature of some products is allowed beyond the range In specific situation please consult the merchant If the air conditioner runs in COOLING or DRY mode with door or window opened for a long time when relative humidity is above 80 dew may drip down from the outlet ED The protective device will work at following cases e Restarting the unit at once after operation stops or changing mode during operation you need to wait 3 minutes e Connect to power supply and turn on the unit at once it may start 20 seconds later O If all operation has stopped press ON OFFbutton again to restart Timer should be set again if it has been canceled Preheat At the beginning of HEATING operation the airflow from indoor unit is discharged 2 5 minutes later Defrost In HEATING operation the appliance will defrost de ice automatically to raise efficie
28. xpansion Cracking sound is or contraction of the front panel due to change heard of temperature Eh e Mist appears when the room air becomes very cold because of cool air discharged from indoor unit during COOLING or DRY operation mode Spray mist from the outlet The compressor indicator red lights on constantly The unit is shifting from heating mode to defrost and indoor fan stops The indicator will lights off within ten minutes and returns to heating mode 8 Installation instructions Installation diagram i Distance from ceiling should be over 200 mm Distance from wall should be over 50mm g X Distance from the wall should be over 50mm CD Distance from floor should be over 2500mm Air intake distance from the wall should be over 250mm
Download Pdf Manuals
Related Search
Related Contents
le chemin desÉtoiles 照明器具取扱説明書 型番:YPL-344・YPL 取扱説明書 - KaVo U920t User`s Manual FastStream VT 5300 Installation and Operation Manual Point of View VGA-560-A2-2048 NVIDIA GeForce GTX 560 Ti 2GB graphics card Spécifications applicables aux viandes hachées P`tit Genius Panda F-SERIES MECH SEAL 1/04 Copyright © All rights reserved.