Home

Detail for SSWC-06-1224 Hybrid controller

image

Contents

1. Page 13 User manual for friend hybrid controller 10 About time delay illumination DC output lighting after Power on 60 seconds approximately Dusk to light lamp NTTV for output 60 seconds approximately Over charge protection on charge 10 seconds approximately Over charge recovery on charge 15 minutes approximately Dawn to turn off lamp DTTV for output 60 seconds approximately Over discharge cut off output 10 seconds approximately Over discharge recovery for output 2 minutes approximately Wind turbine brake 1 hours approximately 11 Model Description UL Battery vol 12V 24V auto Wind turbine power 600W controller Controller wind Wind Energy solar Solar Energy Company code If be monitor type the mode would be SSWC 06 1224 C 12 Maintenance The following inspections and maintenance tasks are recommended at least two times per year for best controller performance Check that the controller is securely mounted in a clean and dry environment Check that the air flow and ventilation around the controller is not blocked Clear all dirt or fragments on the heat sink Check all the naked wires to make sure insulation is not damaged for serious polarization frictional wear dryness insects or rats etc Maintain or replace the wires 1f necessary Tighten all the terminals Inspect for loose broken or burnt wire connections Confirm that all the system components are ground connected tightly and
2. 5 User manual for friend hybrid controller 7 2 Mounting i NOTE When mounting the controller ensure free air through the controller heat sink fins There should be at least 150mm of clearance above and below the controller to allow for cooling If mounted in an enclosure ventilation is highly recommended A WARNING Risk of explosion Never install the controller in a sealed enclose with flooded batteries Do not install in a confined area where battery gas can accumulate Step 1 Choose Mounting Location Locate the controller on a vertical surface protected from direct sun high temperature and water Step 2 Check for Clearance Place the controller in the location where it will be mounted Verify that there is sufficient room to run wires and that there is sufficient room above and below the controller for air flow Step 3 Mark Holes Use a pencil or pen to mark the four 4 mounting hole locations on the mounting surface Step 4 Drill Holes Remove the controller and drill four sizeable holes in the marked locations Step 5 Secure Controller Place the controller on the surface and align the mounting holes with the drilled holes in step 4 Secure the controller in place using the mounting screws 7 3 System connection with controller A recommended connection sequence has been provided for maximum safety during installation g ta e DC OUTPUT BATTERY WIND INPUT SOLAR INPUT Step 1 Battery Wiri
3. 9 8 Controller output DC power illumination eeee ee 10 z Performance Paramcters 3 2 5iceeucc tassel ee eee 12 10 About time delay illumination 0 cece cece eee eee eee eee 13 lis Model Desoripton si cccweiatn cess oes ec sae EEA 13 lee Whaintenane iSev ci neti nauccaiah sealants a T 13 13 Troubleshooting Guid sa03 ensacesdesereass tenaa AR ADER 14 14 Warranty and after Sales Service ccc ccc eee eee ees 14 tas JD OCIARS gae rE N OEN 15 l6 Dimensions seoser a E a aa aS 15 ds ACoessories A OPUONT sieri eee EOIR NS 16 Page 2 User manual for friend hybrid controller 1 Important Safety Operation Information This manual contains important safety installation and operating instructions for controller ZN WARNING Reverse connection of positive and negative is prohibited Short circuit of positive and negative is prohibited DC supply switching power supply or motor driven generator to simulate the wind generator to charge testing is prohibited A CAUTION ___ If your battery voltage lower than 9V connect to controller is prohibited Controller was damaged much possibly caused by this occurrence Solar panel and loading rated power do not higher than controller rating accordingly 2 General Safety Information Please don t use low quality battery to avoid leakage rust or burn Please don t use thin or low quality cable to
4. avoid leakage or fire Do not open cover and maintain personally Keep it away from water moist rain severe dust shaking corrosion and e Intensive or under intense electromagnetic interference e This machine prohibited around the place with any flammable explosive and dangerous goods e Keep any symbols on the controller complete To avoid accidents keep it away from this children 3 General Description The friendly wind solar hybrid controller is specially designed for high end small scale wind solar hybrid system and especially suitable for wind solar hybrid street light system and wind solar hybrid monitoring system gt T L dE i a u Topology Diagram Page 3 User manual for friend hybrid controller Product features MPPT technology to optimize using the wind energy Optional Boost circuit designed Optional 12V 24V System Automatic Recognition function Optional Be able to use for 200W 600W wind turbine with high compatibility Digital design module structure stable and reliable Dual line output light sensor and timer functions morning lighting constantly output 24hours e User can adjust setting of system parameters as timer 5 Protection Functions Solar cells reverse charging solar cells anti reverse connection Battery over charging over discharge battery anti reverse connection Over load load anti reverse connection and load short circuit protection Wind tur
5. check the following 1 Please confirm if the battery positive and negative have connections corre ctly solidly 2 Please use a multi meter to measure if the battery voltage is of 9V or mor e 3 After the controller connected to battery there is minutes delay output DC power supply 4 When the battery is in discharge the controller will cut off the DC power supply output 5 Street lighting system if on day time no DC power output is a normal phenomenon 8 Controller output DC power illumination This device be able to do following 8terms output ways please requested which type are your expectation before you buy NOW YOUR ARE USING TYPE IS ITEM A output Ith line and 2nd line all are constant output DC power for monitor device E gt B 1th line output be lighter on off 2nd output be lighter on timer off rrr Timer a i 0 w Dusk light on Daam light off if you set timer is 15 or above 2 output will same with 1th output It is meaning lamp on off be controlled by light sensor Page 11 User manual for friend hybrid controller C 1th and 2nd output are lighter on timer off if you set timer is 15 or above timer will be invalid It is meaning lamp on off be controlled by light sensor only D 1th line output be full power lighter on off 2nd line output be full power timer off half power CELLET aA T1 full power A T2 half power 7 g W Dusk light
6. correctly Confirm that all the terminals have no corrosion insulation damaged high temperature or burnt discolored sign tighten terminal screws to the suggested torque Check and confirm that lighting arrester is in good condition Replace a new one in time to avoid damaging of the controller and even other equipments Page 14 User manual for friend hybrid controller 13 Troubleshooting Guide Connected to the aa sions Charger to charge the 1 battery the controller y 8 battery or replace the lo does not work a battery Normal wait for the The battery voltage is a system to charge to below the release point the recovery point 2 Somer AO ae Access photovoltaic Remove the battery the controller panels switch on PV photovoltaic panels does not output l Controller is 1 minute output delay battery Normal voltage is normal The voltage of Wind Observe When Wind turbine and photovoltaic or PV is strong The controller is not panels too low enough charging The battery voltage is too high has been in the Normal overvoltage condition Still no output when Batteries rose to a The controller has two observe and test after recovery point from minutes delayed output 1 minute over discharge point 3 LED are blinking Wind turbine braking Normal simultaneously protection The wind speed is too Observe When wind W speed is high lo The battery is not connected the controller Secure
7. on Daam light off You could request 1th and 2 output will be same but need note us before order We will set it before out of factory E 1th line output full power lighter on off 2 line output be full power timer off half power turn off COLLET Ee T1 full power Q T2 half power Q T3 turn off Dusk light on Dawn light off You could request 1th and 2 output will be same but need note us before order We will set it before out of factory F 1th line output be full power lighter on off 2 line output be full power timer off half power turn off morning lighting rye T1 full power a T3 turn off w Q T2 half power Q T4 morning lighting Dusk light on Dawn light off You could request 1th and 2 output will be same but need note us before order We will set it before out of factory Page 12 User manual for friend hybrid controller 9 Performance Parameters 9 1 Wind generator control set up definition Rated Wind Turbine Power 200W 600W Wind Turbine brake voltage 12V 24V 15VAC 25VAC Wind Turbine brake current 12V 24V 10A 20A 9 2 PV panel set up definition Max PV power 12v 24v 150W 300W system max open circuit voltage 12V 24V 24 0V 48 0V Solar panel max charge current 12 5A 9 3 Battery management definition Over charge Recovery Voltage 12V 24V 9 4 Output Set up function 9 5 Product Conventional parameter
8. User manual for friend hybrid controller Z00W 600 W series User Manual wind solar hybrid Controller Model No SSWC 06 1224 Version 5 0 Thank you very much for selecting our product This manual offers important information and suggestions with respect to installation use and troubleshooting etc Please read this manual carefully before using the product and pay attention to the safety recommendations in it User manual for friend hybrid controller Contents 1 Important Safety Operation Information 0 ccccee eee eens 2 2 General Safety Information 2icheiccassuissieeeceas a na 2 3e General Description sireroret niesme aT 2 A Product TCALULCS sabeimior oeei er T A E 3 Ss Protection Functions iti gc Doak alhctedstelacdveciwanevoendtin des 3 6 Panel of controller illumination 0 c cece cece cece eee eens 3 Te Installation INStrucuOns sisena a EA cence 4 7 1 General Installation Notes ccc cece cece eee e cece cece eees 4 7 2 NIQUBEINS rerna an age Ale Aas unre i ouueekn al a 5 7 3 System connection with controller Step Battery WinInet cen EE EA 5 Step 2 Loadins Wie os iGreen eater En Oe 6 Step 3 Solar Module Wiring 00 0 ccccese eee eee e eee enns T Step 4 Wind turbine PMG Wiring cece ccc eee e eee 8 Step 5 Confirmation for Wiring cece cece eee eens 9 Step 6 POWer Up SEQUENCE fecatnkselrnra ico seine EEEE
9. bine current and voltage limited rotation limited and brake 6 Panel of controller illumination MPPT CHARGE 12V amp 24V Auto 1 Charge indication LED green Blinking in charging situation 2 battery LED red over discharge will lighting Blinking mean over charge of battery 8 O P indication LED green This LED lighting mean DC power output normally Blinking mean DC loading power watts exceed rated or load short circuit 4 digitron value hours if be 5 meaning DC output duration is 5hours Then it going next half power process or cut off output supply according to type you are using Button For setting value of digitron Use method as below setting press 5secs The digitron will be blinking meaning enter in Page 4 User manual for friend hybrid controller setting condition press one time the value will be plus 1 if right down point is lighting this value will plus 10 save stop press key then 10sec later the digitron will stop blinking to be lighting this meaning saving successfully Then the digitron will be turn off about 15sec later Digitron will be lighting once connection completed And turn off after 20sec if you want to look value of setting please short press the key Setting value range 0 17 hours IF YOU BUY CONSTANT OUTPUT FOR YOUR MONITOR SYSTEM PLEASE IGNORE ABOVE ITEM SETTING CAUTION When you have comp
10. e The product has applied for patent protection counterfeiting will be subject to legal Si A eS sanctions Our Company reserves the right to change products and without notice when products update 16 Dimensions mm Weight 1 0KG 100 4 6 0 L 152 Page 16 User manual for friend hybrid controller 17 Accessories Option If your buy unit isn t this type mode please ignore following guide 1 Install the data communication wire if required 2 Refer to the instructions provided for detailed installation procedures of software guide Page 17
11. ist voltage connect carefully to avoid short circuit An in line fuse holder should be wired in series in the load positive or negative wire as shown Do not insert a fuse at this time Confirm the connection are correct If wiring the load connection to a load distribution panel each load circuit should be fused separately The total load draw current should not exceed the 10A load rating Step 3 Solar Module Wiring N WARNING Risk of electric shock Exercise caution when handling solar wiring The solar module s high voltage output can cause severe shock or injury Cover the solar module s from the sun before installing solar wiring A CAUTION 1 If you can not confirm the scientific and rational PV module connection by series or parallel way please contact the manufacturer of controller 2 The controller can be applied to the single crystal silicon polycrystalline silicon thin film photo voltaic group Page 8 User manual for friend hybrid controller 3 PV groups open circuit voltage Voc do not higher than rated battery bank voltage 1 8times 4 PV groups operation voltage Vmp do not lower than rated battery bank voltage 1 2times a v gpm H MPPT CHARGE 12V amp 24V Auto E Step 4 Wind turbine PMG Wiring cE _ ay eed Cd MPPT CHARGE 12V amp 24V Auto Please connect wind turbine to controller related terminals Page 9 User manual for friend h
12. leted setting please to disconnection battery aim to turn off controller then after 1Oseconds re start connection of battery to turn on controller This process is intent to make sure the program running in modified setting condition 7 Installation Instructions 7 1 General Installation Notes Read through the entire installation section first before beginning installation Be very careful when working with batteries Wear eye protection Have fresh water available to wash and clean any contact with battery acid e Uses insulated tools and avoid placing metal objects near the batteries Explosive battery gasses may be present during charging Be certain there is sufficient ventilation to release the gasses Avoid direct sunlight and do not install in locations where water can enter the controller Loose power connections and or corroded wires may result in resistive connections that melt wire insulation burn surrounding materials or even cause fire Ensure tight connections and use cable clamps to secure cables and prevent them from swaying in mobile applications e Use with Gel Sealed or Flooded batteries only Battery connection may be wired to one battery or a bank of batteries The following instructions refer to a singular battery but it is implied that the battery connection can be made to either one battery or a group of batteries in a battery bank Select the system cables according to 3A mm current density Page
13. ly connected starts the open circuit again protection function The battery voltage is too high has been in the brake condition The speed of the wind turbine is very low Observe after the Battery discharge 14 Warranty and after Sales Service The charge controller is warranted to be free from defects for a period of ONE 1 years from the date of shipment to the original end user We will at its option repair or replace any such defective products e Claim procedure Page 15 User manual for friend hybrid controller Before requesting warranty service check the Operation Manual to be certain that there is a problem with the controller Return the defective product to us with shipping charges prepaid if problem cannot be solved Provide proof of date and place of purchase To obtain rapid service under this warranty the returned products must include the model serial number and detailed reason for the failure the module type and size type of batteries and system loads This information is critical to a rapid disposition of your warranty claim e This warranty does not apply under the following conditions 1 Damage by accident negligence abuse or improper use PV or load current exceeding the rating of product Unauthorized product modification attempted repair Damage occurring during shipment Damage results from acts of nature such as lightning weather extremes Irreclaimable mechanical damage 15 Declar
14. ng WARNING Risk of explosion or fire Never short circuit battery positive and negative or cables _ If your battery voltage lower than 9V connect to controller is prohibited Controller was damaged much possibly caused by this occurrence Page 6 User manual for friend hybrid controller MPPT CHARGE 12V amp 24V Auto BATTERY CAUTION Before connecting the battery please measure the battery voltage For 24V system batteries voltage must be greater than 18V For 12V system battery voltage must be greater than 9V Y Ne gt The controller will identify system by detection of this parameter If the battery voltage is between 16V 17V the controller is in discriminant blind spot the controller will not work normally please be noted Wire an in line fuse holder no more than 150mm from the battery positive terminal Confirm the connection are correct Step 2 Loading Wiring _ The controller load output can connect DC electronic devices of which rated voltage is same as battery s Device will provide battery voltage to the loads DC loading could be LED lamp or monitor devices etc Page 7 User manual for friend hybrid controller MPPT CHARGE 12V amp 24V Auto Connect load positive and negative to the controller related terminals and connect load2 positive and negative to the controller related terminals accordingly The load terminals may ex
15. ybrid controller The wind turbine rated voltage rated wind speed level should be equal to voltage of battery bank If your wind turbine output is DC power polarity wire can connect to 2 of whereby 3 terminals be optional Step 5 Confirmation for Wiring Double check the wiring in step1 through 5 Confirm correct polarity at each connection Verify that all 10 power terminals are tightened MPPT CHARGE 12V amp 24V Auto Step 6 Power up sequence after confirmation of connection 1 Turn on battery 2 Turn on solar panel 3 Turn on wind turbine 4 Turn on DC loading 5 Turn on switch power for city electric if be this mode AN CAUTION if you would take down system as need must be comply with following sequence Remove wind turbine wiring firstly Remove solar panel wiring Remove DC load wiring Remove batteries wiring lastly oe eee ae Page 10 User manual for friend hybrid controller 1 When the battery power up the controller starts three LED will be blinkin gsimultaneously3 times The controller are in the initialization and detectio n device status of each system 2 Delay of about one minute later the controller output indicator LED to ligh t At the moment indicates have the DCpower output when not connected to the solar panels or solar panel voltage below 6V case If the controller does not start properly or don t have the output DC power su pply after the normal start Please